Loading...
HomeMy WebLinkAboutRES2006-00887, 06-888Ole -V��,) ()G-,�z (7A OPendaflor /3Esselte R 7521/3 10% P4 1- A Gina Southerland - Re: Calling for CO @ 4228 Camber Ct _._,,r Page 1 From: Terry Boriskie To: Benjamin McCarty; Chris Haver; Gina Southerland; Joe Garcia; Kim Wolfe; Mitchell Carson; Nicole Cochran; Paul Schoenfeld; Terry Boriskie Date: 9/27/2006 9:15:50 AM Subject: Re: Calling for CO @ 4228 Camber Ct He has fixed the boxes he is responsible for. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Terry Boriskie 9/26/2006 10:13 am >>> Joe Mike, I have contacted the builder about the house boxes but have no contact information about the HOA and will not be notifying the builder about this HOA box. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Joe Garcia 9/25/2006 4:55 pm >>> THERE ARE 2 WATER METER BOXES ON THIS LOT. ONE METER GOES TO THE HOUSE. IT IS LOCATED ON THE FRONT RIGHT CORNER OF THE LOT. THE OTHER METER IS ON THE FRONT LEFT CORNER OF THE LOT, NEAR THE CORNER OF CAMBER & VICTORIA. IT GOES TO THE CASTLEGATE HOMEOWNERS IRRIGATION SYSTEM. BOTH METER BOXES ARE BROKEN, AND NEED TO BE REPLACED. THE SEWER BOX IS ABOUT 10" BELOW GRADE. I HAVE EXPOSED IT AND PUT A GREEN LOCATE FLAG BY THE HOLE. IT IS IN THE FRONT YARD,AND WILL NEED TO RAISED TO GRADE. JMG >>> Nicole Cochran 09/25/06 12:56 PM >>> Are there any issues? BP# 06-887 Thanks! Nicole Cochran CSR - Planning & Development City of College Station 979.764.3570 www.cstx.g-ov PREPARED 9/25/06, 11:41:22 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/25/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 4228 CAMBER CT SUBDIV: CASTLEGATE SEC 9 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER GREENS PRAIRIE INVESTORS LTD PHONE PARCEL 184200-0902-0010 APPL NUMBER: 06-00000887 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/27/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00 4/27/06 AP April 27, 2006 9:57:33 AM kwolfe B115 O1 6/21/06 OC BLDG, FRAMING TIME: 17:00 6/21/06 DP June 21, 2006 11:18:52 AM bkorthauer Need To Add Windbracing 06/21/2006 03:47 PM OC PDA master bed. Draft stop @ entertainment center. B 15 02 6/28/06 JGM BLDG, FRAMING TIME: 17:00 6/28/06 AP June 27, 2006 4:54:13 PM kwolfe okay to do both - per OC :-) B130 01 6/28/06 JGM BLDG, INSULATION TIME: 17:00 6/28/06 AP June 27, 2006 4:54:23 PM kwolfe okay to do both - per OC B125 01 9/25/ 6 BI BLDG, FINAL TIME: 17:00 September 25, 2006 10:32:59 AM kwolfe ------------------------------------- COMMENTS AND NOTES Date: 9/25/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 887 Address: 4228 CAMBER CT Type Inspection Type Code si tus Inspection Result Comments Description B115 BLDG, FRAMING IC Need To Add Windbracing B115 BLDG, FRAMING IC 06/21/2006 03:47 PM OC PDA B115 BLDG, FRAMING IC master bed. Draft stop @ entertainment center. Page 1 WF0755581 / 001 City of College Station PAGE 1 REQ. DATE: 03/27/06 ,, 03/27/06 10:30:07 LOCATION: 4228 CAMBER CT LOC ID: 195976 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT 4" SEWER TAP AND 3/4" WATER TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/27/06 SCHED COMPLETION: 03/27/06 ******************************************************************************** JOB ORDER RESULT COMVI=S ,rom:STYLECRAFT BUILDERS INC 979 690 0348 05/02/2006 12:19 #027 P.002/003 May 02 06 11:34a Civil Development., Ltd 979-764-7759 p.2 CIVIL DEvnopmENT, Ltd. CIVIL ENGINEERING a DESIGN -BUILD SERVICES P.O. Box 11929 • College Station, Texas 77W . Phone: 979-764-7743 - Fax 979-764-7759 May 1, 2006 RE: Minimum Finish Floor Elevations Castlegate Subdivision —Section 9 College Station, Texas ' To Whom It May Concern: The Final Plat for Section 9 of the Castlegate Subdivision requires a minimum finish floor elevation for each lot that is located adjacent to the 100-year floodplain. The limits of the floodplain (Special Flood Hazard areas inundated by the 100-year stone) and the Base Flood Elevation (BFE) lines shown on the plat are from the Flood Insurance Rate Map (FIRM), Map No. 48041CO205D, revised February 9, 2000. This information is based on the current effective model for the existing conditions. The minimum finish floor elevations shown on the Final Plat for Block 2, Lots I & 2, and Block 3, Lots 1 thru 5 are at least 3 feet above the BFE for the current effective model for structures adjacent to the South Fork of Spring Creek, as required by the City of College Station Drainage Policy and Design Standards. This 3 feet requirement is typically used for undeveloped areas where there has not been a detailed flood study performed for the developed condition. However, the development of this area and its affect on the floodplain has been evaluated by the Floodplain Analysis for the Castlegate Subdivision, which also detennined the floodplain and base flood elevations for this tributary of Spring Creek in the area of the Castle -ate Subdivision. The results of this study were similar to the current effective model. My recommendation is that the minimum finish floor elevations for Section 9 be reduced by 1 foot from the elevations shown on the Final Plat so that the minimum finish floor elevation for each lot is at least 2 feet above. the base flood elevation. The minimum . finish floor for Block 2, Lots l & 2 and Block 3, Lot 1 may be reduced to Elevation 313.0; Block 3, Lot 2 to Elevation 312.5; and Block 3, Lots 3 thru 5 to Elevation 312.0. If you have any questions, please give me a call at (979) 764-7743. Sincerely Yours, Jo ' Schultz. P.E_ Engineering Manager cc: wrallace Phillip.<.. Greens Prail-ic Im-05101-s. Ltd- From:STYLECRAFT BUILDERS INC 979 690 0348 05/02/2006 12:19 #027 P.003/003 A 4 FEDERAL EMERGENCY MANAGEMENT AGENCY O.M.B_ No. 3067-0077 NATIONAL FLOOD INSURANCE PROGRAM Expires December 31, 2005 ELEVATION CERTIFICATE Im ft* Readdw ' 1-7. SECTION A - PROPERTY OWNER INFORMATION rrorinsrance D ornperry Use BUILDING OWNER'S NAME PoiKy Number' StAecraft Builders 1UILDING STREET ADDRESS (Including Apt., Unit, Suite, and/or Bldg. No.) OR P.O. ROUTE AND BOX NO. l Cornpariy NAIL Number 4228 Camber Court CITY STATE ZIP CODE College Station Tx 77M PROPERTY DESCRIPTION (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc) Lot 1, Block 2, Castlegate, Section 9 BUILDING USE (e.g., Residential, NorHesiderdial, Addition, Accessory, etc Use a Convrwls area, if necessary.) residential LATITUDE/LONGITUDE (OPnONAL) HORIZONTAL DATUM: SOURCE: GPS (Type): ( #r - Iff - ##.W or ##_#####) ❑ NAD 1927 0 NAD 1983 ❑ USGS Quad Map ❑ Other. SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1.NFP COMMON TY NAME 8 CONMl1Nrry mAeER BZ COUNTY NAME 83. STATE Collage Shim Brazes Texas B4. MAP AID PANEL i 137. FRM PANEL 89. BASE FLOOD ELEVATIONS) NUMBER B5. SUFFDC B6. FRM INDEX DATE EFFECTNSREVISED DATE 138. FLOOD ZCNE(S) VbneAO, use depth of lood'rg) 48041CO205 D 7-2-1992 2$2000 AE 311 B10. Indicate the source of the Base Flood Elevation (BFE) data orb flood depth entered in B9. ❑ FiS Profile ® FIRM ® Corrrnuuity DeWnined ❑ OW (Describe): Min F F UMMM Set at 314Dft B11. Indicate the elevation datum used for the BFE in W. ❑ NGVD 1929 ❑ NAVD 1988 ❑ Otller (Describe): 812 Is the building located in a Coastal Barrier Resources System (CBRS) area or Ot. enMse Pnotecfed Area (0PA)? ❑ Yes ®No DesignationDate SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ construction Drau►W ®Raiding under Construction• ❑ Fmished A new Elevation Certificate will be required when cormtrtuction of the buiding is oanplete. C2 Building Diagram Number l (Select the building diagram most similar to the building for which this certificate is being completed -see pages 6 and 7. ff no dragrarn accurately represents the building, provide a *etch or photograph.) C3. Elevations —Zones Al-A30, AE, AH, A (with BFE), VE, V1 430, V (with BFE), AR, ARIA, AME, AR(A1 AX, ARIAH, ARIAO OxToete Items C3.-a4 below according to the building diagram specified in Item C2 State the datum used. 9 the datum is different from the datum used for the BFE in Section B, donee the datum to that used for the BFE. Show field measurements and datum conrersion calahation. Use the space provided or the Conmert area of Section D or Section G, as appropriate, to document the datum conversion. Datum _ { op of tiorrnl shots) Elevation reference mark used Does the elevation reference mark used appear on the FIRM? ❑ Yes 0 No o a) Top ct bdbm floor (including basement or enclosure) 313. 70 ft.(m) o b) Top dy next htgtxrfloor _ft(m) ti o c) Bottom of lowest hodmital structural member (V zones only) o d) Attached garage (top of slab) g o e) Lowest elevation of machinery and/or equipment servicing the building (Describe in a Comments area) _ o f) LAwest ad)aoent (finished) grade (LAG) 312.03 fL(m) Z' o g) Nghest Anent (finished) grade (HAG) 312 78 ft.(m) o h) No, otpelmanent openings {flood vents) within 1 ilk above adaoerrt grade o ) Total area of all permanent openings (flood vents) in C3.h so. in. (so. cm) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the infarmatfon in Sections A, Q and C on this cerdficatte represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 US. Code, Section 1001. CERTIFIERS NAME Pad WUams; UCENSE NUMBER Tx RPLS 5743 COMPANY NAME Paul Williams land Surveying ADDRESS CITY STATE ZIP CODE 5400 Ma%4tpne Bryan Tx 77897 4-27-06 979-775-0517 FEMA Form 8"1, January 2003 See reverse side for continuation. Replaces all previous editions r CITY OF COLLEGE STATION Planning cs Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLAN REVIEW/PERMIT NUMBER# 0& DATE: laylo6 BUILDING ADDRESS: 4aa8 CAx,,bee- Gt. I. Foundation Requirements NAjbKj A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum re uirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated /4' 11. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. CITY OF COLLEGE STATION Planning tr Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NA 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. T. Protected openings on walls < three feet from property line One hour tenant separation to roof deck between duplexes Ill. Stairway Requirements N A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6'-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal (*hrqq,4 CITY OF COLLEGE STATION Planning d' Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS V. Electrical Service Requirements N K A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N K A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements NlAfflo A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N O Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements 9AIM Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 JA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 Does not block any water course or divert any flow Elevation certificate if required k CITY OF COLLEGE STATION Planning & Development Services Comments: PLANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS DATE Iffi Permit # Permit Date REScheck Software Version 3.7 Release 1 b Compliance Certificate Project Title: Plan #2694 Report Date: 03/23/06 Energy Code: 2000 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 13% Heating Degree Days: 1788 Construction Site: Owner/Agent: 4228 Camber Court College Station, TX 77845 Permit Date: 00-00-2005 Maximum SHGC: 0.40 Your SHGC: 0.40 Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Cathedral Ceiling (no attic): Wall 1: Wood Frame, 16" o.c.: Window 1: Metal Frame, Double Pane with Low-E: SHGC: 0.40 Door 1: Solid: Door 2: Glass: SHGC: 0.40 Floor 1: Slab-On-Grade:Unheated: , Insulation Depth: 0.0' Floor 2: All -Wood Joist/Truss:Over Outside Air: Air Conditioner 2: Electric Central Air: 13 SEER Furnace 2: Forced Hot Air. 80 AFUE Designer/Contractor: 1882 30.0 0.0 66 62 19.0 0.0 3 2815 13.0 0.0 198 348 0.670 233 38 0.500 19 18 0.440 8 177 0.0 184 15 0.0 0.0 4 Compliance Statement: Statement of Compliance: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 3.7 Release 1 b and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. 3 �3-06 Builder/Designer Company Name Date Project Notes: Previously saved project information: Jennings 4228 Camber Court College Station, Texas Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 Plan #2694 Page 1 of 4 REScheck Software Version 3.7 Release 1 b Inspection Checklist C�(j Date: 03/23/06 Ceilings: ❑ Ceiling 1: Flat Ceiling or, Scissor Truss, R-30.0 cavity insulation Comments: ❑ Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: ❑ Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1: Solid, U-factor: 0.500 Comments: ❑ Door 2: Glass, U-factor: 0.440 Comments: Floors: ❑ Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) ❑ Floor 2: All -Wood JoistlTruss:Over Outside Air, R-0 (uninsulated) Comments: Heating and Cooling Equipment: ❑ Air Conditioner 2: Electric Central Air: 13 SEER or higher Make and Model Number: ❑ Furnace 2: Forced Hot Air: 80 AFUE or higher Make and Model Number: Solar Heat Gain Coefficient: ❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. Plan #2694 Page 2 of 4 ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Ducts in unconditioned spaces must be insulated -to R-5. Ducts.outside the building must be insulated to R-8.0. Duct Construction: ❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181 B. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. Plan #2694 Page 3 of 4 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non -Circulating Runouts Circulating Mains and Runouts Heated Water Temperature (°F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2. Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Piping System Types Range(°F) Heating Systems Low Pressure/Temperature 201-250 Low Temperature 120-200 Steam Condensate (for feed water) Any Cooling Systems Chilled Water, Refrigerant and 40-55 Brine Below 40 NOTES TO FIELD: (Building Department Use Only) Insulation Thickness in Inches by Pipe Sizes 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" 1.0 1.5 1.5 2.0 0.5 1.0 1.0 1.5 1.0 1.0 1.5 2.0 0.5 0.5 0.75 1.0 1.0 1.0 1.5 1.5 Plan #2694 Page 4 of 4 Area Calculator: IEM�� Assembly Type MMIMIM� �MMM Comments/ Description ©� :.� - .. Off■ . � ■ . �� .- �� © � . � � Window Area Total: 348.33 03/23/06 10:43:25 1 /1 Area Calculator: Description Opaque door solid ©l ... .. o�■�■ , „ , „ Door Area Total: 55.56 03/23/06 10:43:26 1 /1 Area Calculator: Assembly Comments/Description Ceiling Area Total: 1944.00 03/23/06 10:43:26 1 /1 Area Calculator: M Assembly Type Comments/Description MM ... FIRST. - ITI, 0=0 SECOND STORY Exterior Wall Area Total: 2815.00 03/23/06 10:43:26 1 /1 Area Calculator: Assembly Type Comments/Description All -Wood joist/Truss, Over Outside Air Floor Area Total: 15.00 03/23/06 10:43:27 1 /1 PAGE 1 WF0762615 / 001 City of College Station . I i ��_n REQ. DATE: 04/24/06 ((��� 04/24/06 14:52:44 LOCATION: 4228 CAMBER CT v LOC ID: 195976 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/24/06 SCHED COMPLETION: 04/24/06 ******************************************************************************** JOB ORDER RESULT CONV=S BUILDING -PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE ST TTION. TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000887 Date 3/27/06 Property Address . . . . . . 4228 CAMBER CT Property ID: 184200-0902-0010 R #: R113092 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE SEC 9 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 187308 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS ------------------------ LTD STYLECRAFT BUILDERS 4490 CASTLEGATE DR 4090 SH 6 S COLLEGE STATION TX 778453388 COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2838.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 1.00 ---------------------------------------------------------------------------.- Permit . . . . . . BUILDING PERMIT Additional desc . . BK Permit Fee . . . . 724.00 Plan Check Fee .00 Issue Date . . . . 3/27/06 Valuation . . . . 187308 Expiration Date . . 9/23/06 Qty Unit Charge Per Extension BASE FEE 460.00 88.00 3.0000 THOU BLDG, VAL 100001-500000 264.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" --------------------------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE ST.�TIONi TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 06-00000887 Date 3/27/06 ---------------------------------------------------------------------------- Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ---------------------------------------------------- •---------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000887 Special Notes and Comments ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED Page 3 Date 3/27/06 PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMP RED (2603 ----- J6;. ......... BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION,, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00000887 Date 3/27/06 ---------------------------------------------------------------------------- Special Notes and Comments IRC) RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES Minimum finished floor 314.00 elevation certificate required. ELEVATION CERTIFICATE REQUIRED - PROVIDE ELEVATION CERTIFICATE PRIOR TO SLAB INSPECTION AND A SECOND CERTIFICATE PRIOR TO FINAL INSPECTION/C.O. Narrow wall bracing Engineered Methods. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 724.00 724.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1474.00 1474.00 .00 .00 BUILDING DEPT REPRESENTATIVE: At4oM* APPLICANT TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 1FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000888 Date 3/27/06 Property Address . . . . . . 4228 CAMBER CT Property ID: 184200-0902-0010 R #: R113092 Application type description TEMP POLE Subdivision Name . . . . . . CASTLEGATE SEC 9 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS LTD ------------------------ STYLECRAFT BUILDERS 4490 CASTLEGATE DR 4090 SH 6 S COLLEGE STATION TX 778453388 COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . BK Permit Fee . . . . 20.00 Issue Date . . . . 3/27/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning &DnnlopwntSemwes wWW.CSTX.GOV I#- y DATE:REG APPLICTEMP P ADDRESS/LOCATION: lf+a'� 9 Cg,k Le( CQ%rr 1 r BLOCK cas-r l e �n�f"t SEC/PH LOT SUBDIVISION BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION " SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Sinale Familv Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: A4®aoN TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ 1 k7 30 S /- TOTAL AREA: 3 31 HEATED AREA: )i 38 (Cost of Labor and Materials) 11 X PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS XX SEWER TAP: 4" INTERIOR WALL TYPE: SIZE �X WATER TAP: 3/a" EXTERIOR WALL TYPE: SIZE ❑ OTHER TAP: FOUNDATION TYPE: SIZE X TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE F__] DOUBLE ® TRIPLE Sheet Rock Siding and/or Masonry Slab on Grade Composition E] ATTACHED FX DETACHED E:] CARPORT SIGNATURE OF APPLICANT: For Stvlecraft *If proposed work involves new commercial construction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only Z 3 L � � ents: / ' YES NO Plans Examiner Zoning Official r JP NI (A/ FL 31 I71c v,oi`a._ cdila d,; w ,e Energy Code Compliance Information % Glazing of exterior walls 3 % Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating .40 .65 R6 13