HomeMy WebLinkAboutRES2006-00855, 06-856ub.,
PREPARED 4/13/07, 11:46:55 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/13/07
------------------------------------------------------------------------------------------------
ADDRESS . : 105 WALCOURT LOOP SUBDIV: EDELWEISS GARTENS PH 9
CONTRACTOR JKM CLASSIC HOMES PHONE (979) 823-1119
OWNER PHONE
PARCEL 244030-0928-0030
APPL NUMBER: 06-00000855 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/27/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00
4/27/06 AP T/S: 04/26/2006 11:14 AM GLSOUTH -----------------------
late afternoon
04/27/2006 09:53 AM RH PDA
Strings up, slab ground installed.
B115 01 6/21/06 RH BLDG, FRAMING TIME: 17:00
6/21/06 AE June 21, 2006 9:12:00 AM bkorthauer
06/21/2006 03:08 PM RH PDA
Need proper nailing pattern for APA at garage. Re check at
insulation inspection.
B130 01 6/27/06 JGM BLDG, INSULATION TIME: 17:00
6/27/06 AP June 27, 2006 10:59:05 AM glsouth
B125 01 4/13/07 / BLDG, FINAL TIME: 17:00
`1 � f '� April 13, 2007 10:55:24 AM kwolfe.
---f.-ITT ---------- t ------ CONTINUED ONTO NEXT PAGE -----------------------------------
v
(4/17/2007) Kim Wolfe Re „Calling for CO @ 105 Walcourt Loop _ Page 1 <§
From: Terry Boriskie
To: Benjamin McCarty; Chris Haver; Gina Southerland; Joe Garcia; Kim Wol...
Date: 4/17/2007 3:37 PM
Subject: Re: Calling for CO @ 105 Walcourt Loop
Contacted Jerry Ponzio at 219-0595 and notified of the needed repairs.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Paul Schoenfeld 4/13/2007 3:37 pm >>>
Water ok.
Sewer buried flagged.
Paul
>>> Kim Wolfe 4/13/2007 11:56 AM >>>
any issues?
BP # 06-855
Thanks
Kimberly Wolfe, CPS
City of College Station
Planning & Development Services
(979)764-3570
www.cstx.aov
Date: 4/13/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 855
Address: 105 WALCOURT LOOP
Insp.
inspection Type Code
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
04/27/2006 09:53 AM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Strings up, slab ground installed.
B115
BLDG, FRAMING
IC
06/21/2006 03:08 PM RH PDA
B115
BLDG, FRAMING
IC
Need proper nailing pattern for APA at garage. Re check at
B115
BLDG, FRAMING
IC
insulation inspection.
Page 1
WF0756493 / 001 City of College Station
PAGE 1
REQ. DATE: 03/30/06 v IJC,� 03/30/06 11:02:13
LOCATION: 105 WALCOURT LOOP LOC ID: 203582
REQUESTOR: JKM CLASSIC HOMES ORIGIN: CUSTOMER -WALK IN
REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/30/06 SCHED COMPLETION: 03/30/06
********************************************************************************
JOB ORDER RESULT COMVMN 'S
WF0756363 / 001 City of College Station
PAGE
REQ. DATE: 03/29/06 03/29/06 16:00:38
LOCATION: 105 WALCOURT LOOP LOC ID: 203582
REQUESTOR: JKM CLASSIC HOMES ORIGIN: CUSTOMER -WALK IN
REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT
4" SEWER TAP AND 3/4" WATER TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/29/06 SCHED COMPLETION: 03/29/06
********************************************************************************
JOB ORDER RESULT COMMENTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION-T-X- 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning
4/17/07
244030-0928-0030
105 WALCOURT LOOP
COLLEGE STATION TX 77845
EDELWEISS GARTENS PH 9
EDELWEISS GARTENS #9, BLOCK 28
LOT 3
SINGLE FAMILY RESIDENTIAL
Owner . . . . . . . . . PONZIO, JERRY A
Contractor . . . . . . JKM CLASSIC HOMES
979 823-1119
Application number 06-00000855 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Approved
Building Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
)e), PU15
ptNG L-1 4f-r - -.-
AMR-
K Lcc>-00? u-fwr L
r 4-
Ll WE
-17
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER# _ � DATE: 3
BUILDING ADDRESS: / o .� G✓a
I. Foundation Requirements
NA/fitRj
A.
Concrete minimum f'c of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier
1. 6 mil poly
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NAIW
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Narrow Wall Bracing Methods indicated on plans
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M.
N.
Span exceeding code tables must be engineered
Rafters sizes, spacing, grade, slope and purlins if required.
CITY OF COLLEGE STATION
Planning c ' Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NAIT
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
(�
Ill. Stairway Requirements
tiTVOK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
NA/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
.4
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning t+Development Services
V. Electrical Service Requirements
NA
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
NAMX
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
VIII. Energy Requirements
N
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
of
Street Ordinance Requirements
NA/
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
OK
Does not block any water course or divert any flow
Elevation certificate if required
CITY OF COLLEGE STATION
Planning cr Development Services
Comments:
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
-2, 06
S EXAMINER DATE
i
Energy Label
Street Address
This home includes the following energy features:
insulation R-Values
insulating
Shaathin -Va ue
12-7OCelling
Ceiling
1� Wall
Wall,
Floor
Basement Wall
Crawl Space Wall
Slab
IZ' . Duct
Mechanical System
Heating System
Cooling System
Water Heater
Glazing/Door 11-Factors
U-Fac—to r
Windows I-0w .45
______ Windows
Sliding Glass Doors
D oorsr�,4;(, - 1-0
0.40 SHGC Maximum
Type and Fuel
G S
Other Energy Features
Efficiency
" —_,-SEER.
EF
r1
- '
With most window brands, a Low E window is required to meet the code
(Sec. 502.1.5 IECC) for solar heat gait coefficient (SHGC). In our climate,
Zone, the maximum SHGC is 0.40.
h
Builder �Date
. a, s" .
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEG TION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00000855 Date 3/29/06
Property Address . . . . . 105 WALCOURT LOOP
Property ID: .•244030-0928-0030
R #.
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 173900
Owner
Contractor
------------------------
------------------------
JKM CLASSIC HOMES
JERRY PONZIO
2006 CARTER CREEK
BRYAN
TX 77802
(979) 823-1119
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1737.00
INTERIOR WALL TYPE
SHEET ROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
BK
Permit Fee . . . .
682.00 Plan Check Fee
.00
Issue Date
3/29/06 Valuation . .
. . 173900
Expiration Date
9/25/06
Qty Unit Charge
Per
Extension
BASE FEE
460.00
74.00 3.0000
THOU BLDG, VAL 100001-500000
222.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
INTERRUPTERS)
BE PROTECTED BY AN ARC -FAULT CIRCUIT
l"1
----------------
BUILDINC
APPLICAr
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGTI. STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000855
Page 2
Date 3/29/06
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
BUILDING
APPLI
A
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000855
Page 3
Date 3/29/06
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 8" ABOVE THE FLOOR IN
--------BUILDING DST REPRESENTATIVE:-----------------------------
APPLI
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGZ STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number
. . . . .
06-00000855
Date
3/29/06
----------------------------------------------------------------------------
Special Notes and
Comments
PRIVATE GARAGES
Narrow wall bracing
Fully Sheathed
with interior
anchors
and bracing.
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
682.00
682.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1432.00
1432.00
.00
.00
---------------
BUILDIn
APPLI CP
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
06-00000856
105 WALCOURT LOOP
244030-0928-0030
TEMP POLE
Date 3/29/06
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner
Contractor
------------------------
------------------------
JKM CLASSIC HOMES
JERRY PONZIO
2006 CARTER CREEK
BRYAN
TX 77802
(979) 823-1119
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. BK
Permit Fee . . .
. 20.00
Issue Date . . .
. 3/29/06
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
----------------------- - - ---------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
41
00
VFq'
CITY OF COLLEGE STATION
Planning d Development Semicet
ADDRESS/LOCATION
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GO
,,V
•• •• I
Wi4 (C OUV.—_r Loi
l� Fw Offi
c
�e Use Only
DATE: `� aEG
APPLICATION # Q
TEMP POLE # 011 56
LOT � BLOCK Z S��-�4
SUBDIVISION �a [.w1 its I s�S ✓t_7 � SEC/P
J9�
BUSINESS/OWNER NAME: KM 04,S r f c itc_+'je-5 PHONE: Z1 9 - 05"9r
CONTRACTOR/HOMEOWNER: tJC'1zI2Y H Zi J PHONE: 2/ Cr c j is
CONTRACTOR ADDRESS: .S,�c7 �,IV 4
ELECTRICIAN: Cip}1Ue6— PLUMBER: �1 _s
f
HVAC:—,Liy'l� / A-(!Z GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE
ADDITION
DEMOLITION (Asbestos Survey)
DUPLEX (Landscape Plans
Required)
ADESCRIPTION OF WORK:
%Nv
t"�%4j"IlkTRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) P JECT REGISTRATION# EABPRJ
VALUATION: $ I DO - TOTAL AREA: 23/ HEATED AREA: 1 tF3_j-
(Cost of La or and Materials) '
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
EWER TAP:
ATER TAP:
9 OTHER TAP:
/ "TEMP
GARAGE TYPE:
SIZE
SIZE
SIZE
SINGLE
ATTAC
SIGNATURE OF APPLIq
*If proposed work involve
commercial property, buildi
LOCATION RE -ROOF
'MOVING SHELL ONLY
NEW CONSTRUCTION # SLAB ONLY
REMODEL/RENOVATION* SWIMMING POOL
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
51^ov
ROOF TYPE: CU/Yj
I LE TRIPLE a
ACHED CARPORT
ial corrtruction orfAcade improvements/renovations to an existing
are required.
0171cial Use Only
z 3--o 6/P Plans Examiner
Zoning Official
ents:
YE or NO
Energy Code Compliance Information
% Glazing of exterior walls (i�3
Insulation R value of exterior walls �— 3
Insulation R value of ceiling 1 (flat areas) iZ - 319
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor �o
R value of ductwork 6
A/C SEER Rating y