HomeMy WebLinkAboutRES2006-00855, 06-856ub., PREPARED 4/13/07, 11:46:55 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/13/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 105 WALCOURT LOOP SUBDIV: EDELWEISS GARTENS PH 9 CONTRACTOR JKM CLASSIC HOMES PHONE (979) 823-1119 OWNER PHONE PARCEL 244030-0928-0030 APPL NUMBER: 06-00000855 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/27/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00 4/27/06 AP T/S: 04/26/2006 11:14 AM GLSOUTH ----------------------- late afternoon 04/27/2006 09:53 AM RH PDA Strings up, slab ground installed. B115 01 6/21/06 RH BLDG, FRAMING TIME: 17:00 6/21/06 AE June 21, 2006 9:12:00 AM bkorthauer 06/21/2006 03:08 PM RH PDA Need proper nailing pattern for APA at garage. Re check at insulation inspection. B130 01 6/27/06 JGM BLDG, INSULATION TIME: 17:00 6/27/06 AP June 27, 2006 10:59:05 AM glsouth B125 01 4/13/07 / BLDG, FINAL TIME: 17:00 `1 � f '� April 13, 2007 10:55:24 AM kwolfe. ---f.-ITT ---------- t ------ CONTINUED ONTO NEXT PAGE ----------------------------------- v (4/17/2007) Kim Wolfe Re „Calling for CO @ 105 Walcourt Loop _ Page 1 <§ From: Terry Boriskie To: Benjamin McCarty; Chris Haver; Gina Southerland; Joe Garcia; Kim Wol... Date: 4/17/2007 3:37 PM Subject: Re: Calling for CO @ 105 Walcourt Loop Contacted Jerry Ponzio at 219-0595 and notified of the needed repairs. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Paul Schoenfeld 4/13/2007 3:37 pm >>> Water ok. Sewer buried flagged. Paul >>> Kim Wolfe 4/13/2007 11:56 AM >>> any issues? BP # 06-855 Thanks Kimberly Wolfe, CPS City of College Station Planning & Development Services (979)764-3570 www.cstx.aov Date: 4/13/2007 Inspection Comments for Finals Permit Year: 6 Permit Number: 855 Address: 105 WALCOURT LOOP Insp. inspection Type Code status Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC 04/27/2006 09:53 AM RH PDA B100 BLDG, FOUNDATION -SLAB IC Strings up, slab ground installed. B115 BLDG, FRAMING IC 06/21/2006 03:08 PM RH PDA B115 BLDG, FRAMING IC Need proper nailing pattern for APA at garage. Re check at B115 BLDG, FRAMING IC insulation inspection. Page 1 WF0756493 / 001 City of College Station PAGE 1 REQ. DATE: 03/30/06 v IJC,� 03/30/06 11:02:13 LOCATION: 105 WALCOURT LOOP LOC ID: 203582 REQUESTOR: JKM CLASSIC HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/30/06 SCHED COMPLETION: 03/30/06 ******************************************************************************** JOB ORDER RESULT COMVMN 'S WF0756363 / 001 City of College Station PAGE REQ. DATE: 03/29/06 03/29/06 16:00:38 LOCATION: 105 WALCOURT LOOP LOC ID: 203582 REQUESTOR: JKM CLASSIC HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT 4" SEWER TAP AND 3/4" WATER TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/29/06 SCHED COMPLETION: 03/29/06 ******************************************************************************** JOB ORDER RESULT COMMENTS City of College Station 1101 TEXAS AVENUE COLLEGE STATION-T-X- 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning 4/17/07 244030-0928-0030 105 WALCOURT LOOP COLLEGE STATION TX 77845 EDELWEISS GARTENS PH 9 EDELWEISS GARTENS #9, BLOCK 28 LOT 3 SINGLE FAMILY RESIDENTIAL Owner . . . . . . . . . PONZIO, JERRY A Contractor . . . . . . JKM CLASSIC HOMES 979 823-1119 Application number 06-00000855 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . Approved Building Official VOID UNLESS SIGNED BY BUILDING OFFICIAL )e), PU15 ptNG L-1 4f-r - -.- AMR- K Lcc>-00? u-fwr L r 4- Ll WE -17 CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLAN REVIEW/PERMIT NUMBER# _ � DATE: 3 BUILDING ADDRESS: / o .� G✓a I. Foundation Requirements NA/fitRj A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements NAIW A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. N. Span exceeding code tables must be engineered Rafters sizes, spacing, grade, slope and purlins if required. CITY OF COLLEGE STATION Planning c ' Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NAIT 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes (� Ill. Stairway Requirements tiTVOK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) NA/ A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal .4 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning t+Development Services V. Electrical Service Requirements NA A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements NAMX A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) VIII. Energy Requirements N A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed of Street Ordinance Requirements NA/ Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required CITY OF COLLEGE STATION Planning cr Development Services Comments: PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS -2, 06 S EXAMINER DATE i Energy Label Street Address This home includes the following energy features: insulation R-Values insulating Shaathin -Va ue 12-7OCelling Ceiling 1� Wall Wall, Floor Basement Wall Crawl Space Wall Slab IZ' . Duct Mechanical System Heating System Cooling System Water Heater Glazing/Door 11-Factors U-Fac—to r Windows I-0w .45 ______ Windows Sliding Glass Doors D oorsr�,4;(, - 1-0 0.40 SHGC Maximum Type and Fuel G S Other Energy Features Efficiency " —_,-SEER. EF r1 - ' With most window brands, a Low E window is required to meet the code (Sec. 502.1.5 IECC) for solar heat gait coefficient (SHGC). In our climate, Zone, the maximum SHGC is 0.40. h Builder �Date . a, s" . BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEG TION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000855 Date 3/29/06 Property Address . . . . . 105 WALCOURT LOOP Property ID: .•244030-0928-0030 R #. Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 173900 Owner Contractor ------------------------ ------------------------ JKM CLASSIC HOMES JERRY PONZIO 2006 CARTER CREEK BRYAN TX 77802 (979) 823-1119 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1737.00 INTERIOR WALL TYPE SHEET ROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . BK Permit Fee . . . . 682.00 Plan Check Fee .00 Issue Date 3/29/06 Valuation . . . . 173900 Expiration Date 9/25/06 Qty Unit Charge Per Extension BASE FEE 460.00 74.00 3.0000 THOU BLDG, VAL 100001-500000 222.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL INTERRUPTERS) BE PROTECTED BY AN ARC -FAULT CIRCUIT l"1 ---------------- BUILDINC APPLICAr BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGTI. STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000855 Page 2 Date 3/29/06 Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE BUILDING APPLI A BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000855 Page 3 Date 3/29/06 Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 8" ABOVE THE FLOOR IN --------BUILDING DST REPRESENTATIVE:----------------------------- APPLI BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGZ STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00000855 Date 3/29/06 ---------------------------------------------------------------------------- Special Notes and Comments PRIVATE GARAGES Narrow wall bracing Fully Sheathed with interior anchors and bracing. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 682.00 682.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1432.00 1432.00 .00 .00 --------------- BUILDIn APPLI CP TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 06-00000856 105 WALCOURT LOOP 244030-0928-0030 TEMP POLE Date 3/29/06 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ JKM CLASSIC HOMES JERRY PONZIO 2006 CARTER CREEK BRYAN TX 77802 (979) 823-1119 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . BK Permit Fee . . . . 20.00 Issue Date . . . . 3/29/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ----------------------- - - --------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: 41 00 VFq' CITY OF COLLEGE STATION Planning d Development Semicet ADDRESS/LOCATION APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CSTX.GO ,,V •• •• I Wi4 (C OUV.—_r Loi l� Fw Offi c �e Use Only DATE: `� aEG APPLICATION # Q TEMP POLE # 011 56 LOT � BLOCK Z S��-�4 SUBDIVISION �a [.w1 its I s�S ✓t_7 � SEC/P J9� BUSINESS/OWNER NAME: KM 04,S r f c itc_+'je-5 PHONE: Z1 9 - 05"9r CONTRACTOR/HOMEOWNER: tJC'1zI2Y H Zi J PHONE: 2/ Cr c j is CONTRACTOR ADDRESS: .S,�c7 �,IV 4 ELECTRICIAN: Cip}1Ue6— PLUMBER: �1 _s f HVAC:—,Liy'l� / A-(!Z GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE ADDITION DEMOLITION (Asbestos Survey) DUPLEX (Landscape Plans Required) ADESCRIPTION OF WORK: %Nv t"�%4j"IlkTRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) P JECT REGISTRATION# EABPRJ VALUATION: $ I DO - TOTAL AREA: 23/ HEATED AREA: 1 tF3_j- (Cost of La or and Materials) ' PUBLIC SEWER SEPTIC/TREATMENT SYSTEM EWER TAP: ATER TAP: 9 OTHER TAP: / "TEMP GARAGE TYPE: SIZE SIZE SIZE SINGLE ATTAC SIGNATURE OF APPLIq *If proposed work involve commercial property, buildi LOCATION RE -ROOF 'MOVING SHELL ONLY NEW CONSTRUCTION # SLAB ONLY REMODEL/RENOVATION* SWIMMING POOL NUMBER OF BEDROOMS NUMBER OF BATHROOMS INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: 51^ov ROOF TYPE: CU/Yj I LE TRIPLE a ACHED CARPORT ial corrtruction orfAcade improvements/renovations to an existing are required. 0171cial Use Only z 3--o 6/P Plans Examiner Zoning Official ents: YE or NO Energy Code Compliance Information % Glazing of exterior walls (i�3 Insulation R value of exterior walls �— 3 Insulation R value of ceiling 1 (flat areas) iZ - 319 Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor �o R value of ductwork 6 A/C SEER Rating y