HomeMy WebLinkAboutRES2006-00847r
R752113 10%ISP4
• :r
PREPARED
1/02/07,
11:57:05
INSPECTION TICKET
PAGE 2
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 1/02/07
-----------------------------------------------------------------------------------
ADDRESS
. : 2417 NEWARK CIR
SUBDIV: CASTLEGATE SEC
----
5 PH 1
CONTRACTOR
PHILIP
BLACKBURN
(MAVERICK) PHONE (979) 693-2364
OWNER
GREENS
PRAIRIE INVESTORS LTD PHONE
PARCEL
184200-1502-0170
APPL NUMBER: 06-00000847 RESIDENTIAL,
1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
4/07/06
OC
BLDG, FOUNDATION -SLAB TIME: 17:00
4/07/06
AP
T/S: 04/07/2006 08:25 AM GLSOUTH -----------------------
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
5/08/06
JGM
BLDG, FRAMING TIME: 17:00
5/08/06
AE
May 8, 2006 8:57:10 AM bkorthauer
05/08/2006 01:14 PM JGM PDA
needs anchor bolts and letin bracing per print, missing
anchor bolt nuts back wall, need anchors at
splices of
O
sole plate
3130 O1
5/10/06
JGM
BLDG, INSULATION TIME: 17:00
5/10/06
AP
T/S: 05/09/2006 03:17 PM GLSOUTH -----------------------
late morning
B125 1
1/02/07
B'�_
BLDG, FINAL TIME: 17:00
January 2, 2007 9:33:12 AM
ncochran.
-------------------------K=k----------
COMMENTS AND NOTES--------------------------------------
Kim Wolfe - Re: Calling for C.O. @ 2417 Newark Cir. ' _ _� �- "_ - " n , , " F ��,Page 1
From: Joe Garcia
To: Benjamin McCarty; Chris Haver; Gina Southerland; Kim Wolfe; Mitchell Carson;
Nicole Cochran; Paul Schoenfeld; Terry Boriskie
Date: 1/2/2007 3:03:15 PM
Subject: Re: Calling for C.O. @ 2417 Newark Cir.
THIS ONE IS OK. JMG
>>> Gina Southerland 01/02/07 12:28 PM >>>
BP# 06-847
Gina Southerland
Customer Service Rep.
City Of College Station
1101 Texas Ave.
979-764-3570
glsoutherland(cDcstx.gov
Date: 1 /2/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 847
Address: 2417 NEWARK CIR
Insp.
Inspection Type Code
Status s
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
13115
BLDG, FRAMING
IC
05/08/2006 01:14 PM JGM PDA
6115
BLDG, FRAMING
IC
needs anchor bolts and letin bracing per print, missing
B115
BLDG, FRAMING
IC
anchor bolt nuts back wall, need anchors at splices of
13115
BLDG, FRAMING
IC
sole plate
E110
ELEC, ROUGH IN
IC
05/08/2006 01:10 PM JGM PDA
E110
ELEC, ROUGH IN
IC
needs cold water bond
E150
ELEC, FINAL
IC
08/04/2006 11:57 AM JGM PDA
E150
ELEC, FINAL
IC
house locked
Page 1
WF0757277 / 001 City of College Station
PAGE 1
REQ. DATE:
04/03/06
04/03/06
13:37:03
LOCATION:
2417 NEWARK CIR
LOC ID:
201010
REQUESTOR:
PHILIP BLACKBURN (MAVERICK) ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
4" SWR
TAP 3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START: 04/03/06 SCHED COMPLETION:
04/03/06
********************************************************************************
JOB ORDER
RESULT COMIE TTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATI014-=i 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning
1/03/07
184200-1502-0170
2417 NEWARK CIR
COLLEGE STATION TX 77845
CASTLEGATE SEC 5 PH 1
CASTLEGATE SEC 5, PHS 1, BLOCK
2, LOT 17
PLANNED DEVL HOUSING
Owner . . . . . . . . . GREENS PRAIRIE INVESTORS LTD
Contractor . . . . . . PHILIP BLACKBURN (MAVERICK)
979 693-2364
Application number 06-00000847 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Approved
•
id. ��
Building Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
BUILDING PERMIT
CITY OF COLL)EGE STATION
1101S AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
06-00000847 Date 4/03/06
2417 NEWARK CIR
184200-1502-0170
R300552
RESIDENTIAL, 1 UNIT DETACHED NEW
CASTLEGATE SEC 5 PH 1
RESIDENTIAL
PLANNED DEVL HOUSING
206976
Owner- Contractor
------------------------ ------------------
GREENS PRAIRIE INVESTORS LTD -GWNFR �ht l�`p �j �� �1 C A&VCU
4490 CASTLEGATE DR
COLLEGE STATION TX 778453388
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
3136.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
441.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KW
Permit Fee . . . .
781.00 Plan Check Fee
.00
Issue Date . . . .
4/03/06 Valuation . . .
. 206976
Expiration Date . .
9/30/06
Qty Unit Charge
Per
Extension
BASE FEE
460.00
107.00 3.0000
THOU BLDG, VAL 100001-500000
321.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS
OPENING (MINIMUM RQUGH-FRAMED SIZE
22"
-----------------
BUILDING
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000847
Page 2
Date 4/03/06
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
BUILDING
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000847
Page 3
Date 4/03/06
Special Notes and Comments
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR�THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Make sure of proper smoke detector locations
Narrow wall bracing Fully Sheathed with Interior anchoring
at back porch
Other Fees
BUILDING
APPLICAN'.
SEWER TAP 4"
350.00
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number
. . . . .
06-00000847
Date 4/03/06
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid
----------
Credited
----------
Due
----------
Permit Fee Total
781.00
781.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1531.00
1531.00
.00
.00
-------------
BUILD
APPLI
-1 11
o07; a
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.CO LLEG E-STATI ON.TX. US
ADDRESS/LOCATION: YJ< 1 7 AZ
LOT ��OCK -A - SUBDIVISION
BUSINESS/OWNER NAME: `' 471
CONTRACTOR/HOMEOWNER:
f
CONTRACTOR ADDRESS: 6 (0_ _L_�alU/
ELECTRICIAN: I / ��/�! /2
HVAC:
Fw Office Use Only
DATE: Aaaru
APPLICATION #
TEMP POLE7-nf,-0(��
/ SEC/PH
;PHONE:
�ir�-K i i�10NE: JJ
PLUMBER:
GOOD CENTS (Resid tial only): (�
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL
Required) /
'ION OF WORK:
STRUCTURE USE:
HOMEOWNER ASSOCIATIO
OR QLrSIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPR.,
VALUATION: $ TOTAL AREA: ,2
(Cost of LaIdor and Materials)
PUBLIC SEWER 0m1j ( `(# . d ✓ NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM
SEWER TAP:
SIZE
WATER TAP:
IZE
OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE
SINGLE
ATTACHED
SIGNATURE OF APPLICANT:
9X. 3—
W S1j LacA44P*1r
L FV11g s44,J4 U(
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE
FOUNDATION TYPE
ROOF TYPE:
y
DOUBLE
DETACH-'�
Official Use Only
TRIPLE
HEATED AREA:313j�
♦♦♦♦♦♦♦♦♦♦♦♦♦
C ments:
YE or NO
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
, Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
CITY OF COLLEGE STATION
Planning ear' Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER# 0%� I DATE: 3 /a 31 of,,
BUILDING ADDRESS: a i �k C►ti,
I. Foundation Requirements
NA/
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
11. Framing: Floor, Wall, Ceiling and Roof Requirements
A
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
1 PLAN REVIEW
ONE and TWO FAMILY
CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS
Planning 6 Development Services
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
N
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
Ill. Stairway Requirements
tIMOK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six (6-6") inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
CITY OF COLLEGE STATION
Planning 6-Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
A/
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
riAJ40
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
NAM
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
K
Does not block any water course or divert any flow
Elevation certificate if required
CITY OF COLLEGE STATION
Planning cr Development Services
Comments:
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLANS EXAMINER DATE
/
U. M. C .' MAVERICK BUILDERS, INC.
2O8-D SOUTHWEST PKWY. E.
COLLEGE STATION, TX 71840
/
~