HomeMy WebLinkAboutRES2006-00841, 06-843►
t�
OPendatlenr
arsse/to
R 7521/3 10% P4
.
PREPARED 8/23/06,
7:18:02
INSPECTION TICKET
PAGE 3
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 8/23/06
------------------------------------------------------------------------------------------------
ADDRESS
. : 1206 BEACON CT
SUBDIV:
CONTRACTOR RIKE HOMES
PHONE (979) 774-0165
OWNER
PHONE
PARCEL
- -
APPL NUMBER: 06-00000841 RESIDENTIAL, 1 UNIT DETACHED NEW
I
-----------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
-------------------------------------------------------
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
4/04/06
RH
BLDG, FOUNDATION -SLAB TIME: 17:00
4/04/06
AP
April 4, 2006 9:22:15 AM bkorthauer
04/04/2006 02:45 PM RH PDA
Strings up, slab ground installed.
B115 01
5/16/06
RH
BLDG, FRAMING TIME: 17:00
5/16/06
AP
May 16, 2006 12:31:53 PM kwolfe
B130 01
5/19/06
JGM
BLDG, INSULATION TIME: 17:00
5/19/06
AP
May 18, 2006 2:36:17 PM bkorthauer
B125 01
8/23/06
BI
BLDG, FINAL TIME: 17:00
-
August 22, 2006 4:23:36 PM glsouth
---------t----------------------------
j
COMMENTS AND NOTES --------------------------------------
1
�
Date: 8/23/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 841
Address: 1206 BEACON CT
Insp.
inspection Type Code Description
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
04/04/2006 02:45 PM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Strings up, slab ground installed.
E110
ELEC, ROUGH IN
IC
05/16/2006 03:04 PM RH PDA
E110
ELEC, ROUGH IN
IC
Noted to make sure smoke detectors have 3 ft. min.
E110
ELEC, ROUGH IN
IC
clearance from ceiling fan blades.
E150
ELEC, FINAL
IC
08/03/2006 04:43 PM RH PDA
E150
ELEC, FINAL
IC
Whirlpool tub outlet has hot/nuetral reversed. Smoke
E150
ELEC, FINAL
IC
detector needs min. 3ft. from ceiling fan blades.
E150
ELEC, FINAL
IC
Kitchen/dining wall outlets are not hot.
E150
ELEC, FINAL
IC
08/07/2006 04:34 PM RH PDA
E150
ELEC, FINAL
IC
Recheck gfi for tub on building final.
M110
MECH, FINAL
IC
August 4, 2006 9:40:51 AM kwolfe
M110
MECH, FINAL
IC
Chris canceled - not ready
Page 1
Y
CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER# OCo _ 841 DATE: 3 ba/oe.
BUILDING ADDRESS: �ao� �Q�oN CA.
I. Foundation Requirements
NA/
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing plan or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
11. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NAT
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
q
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
q/ K
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6") inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning e+Development Services
PW
V. Electrical Service Requirements
NA/
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
NAW
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 1.8" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
NA?AK,)
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N A ADR,
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
N WK,
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
K
Does not block any water course or divert any flow
Elevation certificate if required
4
CITY OF COLLEGE STATION
planning d Development Services
Comments:
PLANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
3 - za --
DATE
TF0759924 / 001 City of College Station PAGE 1
5
REQ. DATE: 04/12/06 04/12/06 16:57:07
LOCATION: 1206 BEACON CT LOC ID: 201510
REQUESTOR: RIKE HOMES ORIGIN: CUSTOMER -WALK IN
REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 04/12/06 SCHED COMPLETION: 04/12/06
********************************************************************************
JOB ORDER RESULT COM4ENTS �� J
WF0755106 / 001 City of College Station
PAGE 1
REQ. DATE:
03/23/06
',�
03/23/06
15:42:06
LOCATION:
1206 BEACON CT
LOC ID:
201510
REQUESTOR:
RIKE HOMES
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
BKORTHAUER AUTH. USER:
BKORTHAUER
WORK TYPE:
ROUT
4" SEWER
TAP AND 3/4" WATER TAP
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
03/23/06 SCHED
COMPLETION:
03/23/06
********************************************************************************
JOB ORDER RESULT COM VI TrS
BUILDING PERMIT
CITY OF COLLEGE STATION_`"�
1101 .TEX_ AS AVE
COLLEGE STATIPaN, TX 77840
PHONE: (979) 764-3 7,0',, FAX: (979) 764-3496
'
---------------------------------------------------------------------------
Application Number . . . . . 0'6-00000841 Date 3/23/06
Property Address . . . . . . 12'06 BEACON CT
Property ID: - -
R #: R*****
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 221900
Owner
Contractor
------------------------
------------------------
RIKE HOMES
2210 E BRIARGATE
BRYAN
TX 77802
(979) 774-0165
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2684.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.50
NUMBER OF BEDROOMS
5.00
SEWER TYPE
PUBLIC
TAZ
447.00
----------------------------------------------------------------------------
Permit
BUILDING PERMIT
Additional desc
BK
Permit Fee . . . .
826.00 Plan Check Fee
.00
Issue Date . . . .
3/23/06 Valuation . .
. . 221900
Expiration Date . .
9/19/06
Qty Unit Charge
Per
Extension
BASE FEE
460.00
122.00 3.0000
THOU BLDG, VAL 100001-500000
366.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS
OPENING (MINIMUM ROUGH -FRAMED SIZE
2211
--------------------------------------- -- --�-- -------------------------
BUILDING DEPT RE T NVE:
APPLICANT: �i�
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3'570 FAX: (979) 764-3496
Application Number . . . . . 06-00000841
Page 2
Date 3/23/06
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
--------------------------------= ---- -------------- ----------
BUILDING DEPT REP
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000841
Page 3
Date 3/23/06
Special Notes and Comments
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Narrow wall bracing Fully Sheathed
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
BUILDING DEPT REPRE
,EN�A�E
APPLI
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Page 4
Application Number
. . . . .
06-00000841
Date 3/23/06
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid
----------
Credited
----------
Due
----------
Permit Fee Total
826.00
826.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1576.00
1576.00
.00
.00
BUILDING DEPT REPRESELL TT-5E
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
R #:
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
06-00000843
1206 BEACON CT
R*****
TEMP POLE
Date 3/23/06
SINGLE FAMILY RESIDENTIAL
0
Owner
Contractor
------------------------
------------------------
RIKE HOMES
2210 E BRIARGATE
BRYAN
TX 77802
(979) 774-0165
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. BK
Permit Fee . . .
. 20.00
Issue Date . . .
. 3/23/06
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
------------------------------
Due
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
BUILDING DEPT REP9,N E:
APPLICANT: ��/ -
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W WW.CI.COLLEGE-STATION.TX. US
For OMae Use Only
DATE:
APPLICATION # - tQ5/'� I
TEMP POLE # C& - 0 `[�
ADDRESS/LOCATION: 1206 BEACON CT.
LOT 1 +/ULOCK 6 Sb1 DIVISION SOUTH HAMPTON J PHASE
BUSINESS/OWNER NAME: RIKE HOMES, LLC. PHONE: 774-0165
CONTRACTOR/HOMEOWNER: Tom Rike PHONE: 224-4616
CONTRACTOR ADDRESS: 2210 E. Briar -gate
ELECTRICIAN: Mathew's Electric PLUMBER: Bass Plumbing
control Te GOOD CENTS (Residential only): No
CLASS OF WORK
(4 f AE LOCATION RE -ROOF (Total/Partial)
A � ITI N MOVING SHELL ONLY
DEMOLITION estos Survey) X NEW CONSTRUCTION SLAB ONLY
Plans Req) REMODEURENOVATION SWIMMING POOL
Tt0SRK Conventional Framina
5 I IiLJGI`l1RE USE: Sinale Family Residence
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STA%ARD (TAS) PROJECT REGISTRATION# EABPRJ N/A
VALUATION: $221.900 / TOTAL AREA:_3368 HEATED AREA:2684
(Cost of Labor and Materials)
DX PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
Q X SEWER TAP: 4"
SIZE
QX WATER TAP: %11
SIZE
❑ OTHER TAP:
QX TEMP POLE
GARAGE TYPE:
SIZE
SINGLE a
ATTACHED FX
SIGNATURE OF APPLICANT:
-aa,aco
ticlp Plans Examiner
z lt
� �LAA4
NUMBER OF BEDROOMS: 5
NUMBER OF BATHROOMS: 3.5
INTERIOR WALL TYPE: Sheet Rock
EXTERIOR WALL TYPE: Siding/Masonry/Stone
FOUNDATION TYPE: Slab on Grade
ROOF TYPE: Composition
DOUBLE TRIPLE
DETACHED CARPORT
Official Use Only
Zoning Official
C ments:
or NO
Energy Code Compliance Information
% Glazing of exterior walls 3 %
Insulation R value of exterior walls R13
Insulation R value of ceiling 1 )
R30
(flat areas
Insulation R value of ceiling 2 (vaulted areas/no attic) R19e"""
Glazing SHGC .40
Glazing U-Factor .65 Z
R value of ductwork R6
A/C SEER rating 12 .,-'-'