Loading...
HomeMy WebLinkAboutRES2006-00839, 06-840Wgsq 1 r OPendafle)C /3 Esselto Ank R 7521/3 10% P4 PREPARED 10/26/06, 8:04:56 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/26/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 904 WHITEWING LN SUBDIV: DOVE CROSSING CONTRACTOR D R HORTON HOMES PHONE (512) 748-4017 OWNER . . PHONE PARCEL . . 005401-0104-0030 APPL NUMBER: 06-00000839 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/18/06 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 4/18/06 AP April 18, 2006 10:14:26 AM bkorthauer Form Survey Submitted Slab Ground Installed B115 01 6/12/06 JGM BLDG, FRAMING TIME: 17:00 6/12/06 AE June 8, 2006 1:37:28 PM bkorthauer 06/12/2006 10:35 AM JGM PDA need letin bracing on kitchen wall and hallway bathroom wall behind tub B130 01 6/15/06 JGM BLDG, INSULATION TIME: 17:00 6/15/06 AP June 15, 2006 10:58:51 AM glsouth B125 01 10/26/06 BI u BLDG, FINAL TIME: 17:00 CI` III October 25, 2006 2:12:22 PM glsouth ------- COMMENTS AND NOTES Date: 10/30/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 839 Address: 904 WHITEWING LN Type Inspection Type Code Description si tus Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC Form Survey Submitted B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B115 BLDG, FRAMING IC 06/12/2006 10:35 AM JGM PDA B115 BLDG, FRAMING IC need letin bracing on kitchen wall and hallway bathroom B115 BLDG, FRAMING IC wall behind tub M110 MECH, FINAL IC 08/03/2006 11:51 AM OC PDA M110 MECH, FINAL IC sheetrock return air. 1 inch clearance around flue. M110 MECH, FINAL IC combustion air 12inch top and bottom. M110 MECH, FINAL IC 10/13/2006 03:33 PM RH PDA M110 MECH, FINAL IC Flue pipe needs to be securely attached to unit. Flue pipe M110 MECH, FINAL IC needs min. 1" of clearance from combustibles [ceiling]. Page 1 WF0754908 / 001 City of College Station PAGE 1 B REQ. DATE: 03/23/06 a 03/23/06 8:19:26 LOCATION: 904 WHITEWING LN LOC ID: 202832 REQUESTOR: D R HORTON _' ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT 4" SEWER TAP AND 3/4" WATER'TAP TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/23/06 SCHED COMPLETION: 03/23/06 ******************************************************************************** JOB ORDER RESULT CONIlY=S City of College Station 1101 TEXAS AVENUE COLLEG.B_.,T.ATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . Contractor . . . . . . Application number Description of Work Construction type Occupancy type . Flood Zone . . . . Approved . . . . . . 11/21/06 005401-0104-0030 904 WHITEWING LN COLLEGE STATION TX 77845 DOVE CROSSING DOVE CROSSING SUBDIVISION PHASE lA BLK 4 LT 3 SINGLE FAMILY RESIDENTIAL D R HORTON HOMES 512 748-4017 06-00000839 000 000 RESIDENTIAL, 1 UNIT DETACHED NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX '"R;=cVrng -0f f icia1 VOID UNLESS SIGNED BY BUILDING OFFICIAL i CITY OF COLLEGE STATION Planning d' Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLAN REVIEW/PERMIT NUMBER# 0(,_ p37 1 DATE: 3 /a.2lo�, BUILDING ADDRESS: 904/ A/ti;4U„ A ri /--N , 0 I. Foundation Requirements NA/ A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated Il. Framing: Floor, Wall, Ceiling and Roof Requirements N O A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning & Development Services II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NA/ 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes III. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum of ten (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements (to be indicated onplans) NA/ A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal (*hr,4" CITY OF COLLEGE STATION Planning d' Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements NAIM A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VI1. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) VII1. Energy Requirements NA/ A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N K Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements N Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required CITY OF COLLEGE STATION Planning & Development Services Comments: J144� L... PLANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS — Z L--0 6 DATE Permit # Permit Date 0 REScheck Software Version 3.7 Release 1 8/"' Compliance Certificate Project Title: 2001 H-Vaulted Report Date: 03/09/06 Energy Code: 2003 IECC Location: Brazos County, Texas Construction Type: Single Family Glazing Area Percentage: 11 % Heating Degree Days: 1999 Construction Site: Owner/Agent: 904 Whitewing Lane D.R. Horton Austin College Station, TX 12554 Riata Vista Circle Austin, TX 78727 512-345-4663 Maximum SHGC: 0.40 Your SHGC: 0.36 Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Flat Ceiling or Scissor Truss: Wall 1: Wood Frame, 16" o.c.: Window 1: Metal Frame:Double Pane with Low-E: SHGC: 0.36 Door 1: Solid: Door 2: Glass: SHGC: 0.37 Floor 1: Slab-On-Grade:Unheated: , Insulation Depth: 0.0' Furnace 1: Forced Hot Air: 80 AFUE Air Conditioner 1: Electric Central Air: 13 SEER Designer/Contractor: 1530 30.0 0.0 54 471 22.0 0.0 21 1694 13.0 0.0 121 162 0.700 113 38 0.350 13 18 0.440 8 212 0.0 221 Compliance Statement. Statement of Compliance: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.7 Release 1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer Company Name Project Notes: Water Heater: Gas uate 2001 H-Vaulted Page 1 of 4 0 REScheck Software Version 3.7 Release 1 N/" Inspection Checklist Date: 03/09/06 Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: ❑ Ceiling 2: Flat Ceiling or Scissor Truss, R-22.0 cavity insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: ❑ Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.700 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1: Solid, U-factor: 0.350 Comments: ❑ Door 2: Glass, U-factor: 0.440 Comments: Floors: ❑ Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Solar Heat Gain Coefficient: ❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Skylights: ❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-13. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-8. 2001 H-Vaulted Page 2 of 4 ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-4. ❑ Supply ducts in unconditioned spaces must be insulated to R-6. ❑ Return ducts in unconditioned spaces (except basements) must be insulated to R-2. ❑ Where exterior walls are used as plenums, the wall must be insulated to R-8. ❑ Insulation is not required on return ducts in basements. Duct Construction: ❑ Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened. ❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181 B. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. 2001 H-Vaulted Page 3 of 4 r. . Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non -Circulating Runouts Circulating Mains and Runouts Heated Water Temperature ("F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp Piping System Types Rangeff) Heating Systems Low Pressure/Temperature 201-250 Low Temperature 106-200 Steam Condensate (for feed water) Any Cooling Systems Chilled Water, Refrigerant and 40-55 Brine Below 40 NOTES TO FIELD: (Building Department Use Only) Insulation Thickness in Inches by Pipe Sizes 2" Runouts 1" and Less 1.25" to 2.0" 2.5' to 4" 1.0 1.5 1.5 2.0 0.5 1.0 1.0 1.5 1.0 1.0 1.5 2.0 0.5 0.5 0.75 1.0 1.0 1.0 1.5 1.5 2001 H-Vaulted Page 4 of 4 WF0755062 / 001 City of College Station PAGE 1 REQ. DATE: 03/23/06 03/23/06 14:24:34 LOCATION: 904 WHITEWING LN LOC ID: 202832 REQUESTOR: D R HORTON ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/23/06 SCHED COMPLETION: 03/23/06 ******************************************************************************** JOB ORDER RESULT CONV=S Avr,11. 2006 11:18AM Strong Surveying.. No.1623 P. 2 .OMA 7 S 7RONG V22 Bmadmoor Su1Ce 105 s"ni, Texas 27802 "h°ax fW9) 6 URVEYING Fax (�) M-009-0096 erna& =W*stmngsurveyingC0M FORM CHECK North Orientation is based on rotating the NorthEast line to the Plat Calls in volume 6968. Page 35. 1/2" Iron Rod W/cap found at all comers, unless otherwise noted. All bearings and distances are Call and Actual. LOT 39(Phase IB) The TBM Elevation Shown hereon is based on the Grading Pion Prepared by Texcon. SCALE: 1 ° = 20' LEGEND P.U.E. — Public Utility Esmt. F.F. — finished Floor LOT 401Phose IB) I LOT 41(Phase IB) b o Ni :N all ( 20' Building Setback . il) N e' Lot 3 a 0 0 u u ui '6 _ o a a = Lot 4 w o N a I gd FORM m I c o w F.F. = 311,91' - C c o Lot 2 M "� Min. F.F. = 310.0' o m m Z 25.0' 0.60' 13.9' 25' Building Setback Oi f; 1 N: 5' P.U.E.16968/351 N 41.55'21- E 55.00' 904 Whitewing Lane Cu- b?--fl BUYER: A Title Commitment was not available at the time of this survey, therefore only easements shown on the Record Subdivision Plot are indicated an this plat. Lot Three(3), Block Four(4) of Dove Crossing Subdivision, an addition to the City of College Station, Brazos County, TEXAS according to the plat recorded in Volume 6968, Page 35 of the Official Records of Brazos County, Texas. I, H. Curtis Strong, Registered Professional Land Surveyor No. 4961, do hereby certify that the above plat is true and correct and represents the results of a survey performed on the ground under my supervision on April 10, 2006. 1 further certify that no improvements on this property encroach on adjacent property nor do any improvements on adjacent property encroach on this property, except as shown. This property is not located within a 100 — year flood hazard area as depicted from FLOOD INSURANCE RATE MAP NO.48041CO201 C , DATED: JULY 2, 1992. This Plat is copyrighted in 2006, and is for the sole purpose of the buyer as shown. Any other use is strictly prohibited without the express written consent of Strong Surveying. BUILDING PERMIT "- CITY OF COLLEGE STATION 11 0ii—TELMAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570t ,. FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000839 Date 3/22/06 Property Address . . . . . . 904 WHITEWING LN Property ID . . . . . . . . . 005401-0104-0030 R # R13907 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . DOVE CROSSING Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 132066 Owner Contractor ------------------------ ------------------------ D R HORTON HOMES 12554 RIATTA VISTA CIRCLE SECOND FLOOR AUSTIN TX 78727 (512) 74 8 -4017 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2001.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit Fee . . . . 559.00 Plan Check Fee .00 Issue Date . . . . 3/22/06 Valuation . . . . 132066 Expiration Date . . 9/18/06 Qty Unit Charge Per Extension BASE FEE 460.00 33.00 3.0000 THOU BLDG, VAL 100001-500000 99.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) BUILDING DEPT REPRESENTATIVE: r _ APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 110-1 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000839 Page 2 Date 3/22/06 Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE C_AA�� BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 11G1 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000839 Page 3 Date 3/22/06 Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN �. ------------------------------------ BUILDING DEPT REPRESENTATIVE: n APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00000839 Date 3/22/06 ---------------------------------------------------------------------------- Special Notes and Comments PRIVATE GARAGES Wind bracing methods used are Engineered Methods. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited -------------------- Due ---------- ----------------- Permit Fee Total ---------- 559.00 559.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1309.00 1309.00 .00 .00 BUILDING DEPT REPRESENTA T-KE APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000840 Date 3/22/06 Property Address . . . . . . 904 WHITEWING LN Property ID 005401-0104-0030 R ## R13907 Application type description TEMP POLE Subdivision Name . . . . . . DOVE CROSSING Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ D R HORTON HOMES 12554 RIATTA VISTA CIRCLE SECOND FLOOR AUSTIN TX 78727 (512) 748-4017 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc GS Permit Fee 20.00 Issue Date . . . . 3/22/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - APPLICANT: 11AY-18-2PO4 02:21 From: 4. To:512 21e 4299 P.3/4 cJ APPLICATION (�R2EOq //l--� " D TEMP POLE # Du APPLICATION FOR BUILDING PERMIT DATE: CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF CULLEC:E S K110tJ (979) 764-35TO (979) 764.3496 FAX Pl--41 dr Nwtgmew Snwi x1 — WWW.G$TX.GOV l ADDRESS/LOCATION: lS�` J�t�Q_(��� e LOT �_ BLOCK � � SUBDIVISION p � o SEC/PH_jA ' BUSINESS/OWNER NAME: v PH0NE:SIa' S33 -I `� U� CONTRACTOR/HOMEOWNER: -IR / `* p n PHONE: Jf(a5 - 33 - r 7v� CONTRACTOR ADDRESS: /�S�y A/!S VISTy `lrC Lam-- ��S�j1.� 7,C 7� �a W� ELECTRICIAN: r-V'' S� 6 �P O3 PLUMBER: Q S /�r► mil. co �p /� HVAC: f Q�t,1 ��S- �5� GOOD CENTS (Resldentlal only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION ` SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION' SWIMMING POOL Required) eA DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL - TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ I 1 D(Q (e / TOTAL AREA: J5� HEATED AREA: Z Op (Cost of Labor and Materials) 0 PUBLIC SEWER EPTIC/TREATMEN-e SYSTEM WER TAP: Lf 3 1 E i WATER TAP: Size OTHER TAP: — -------_-..SIZE- - - TEMP POLE GARAGE TYPE: SINGLE a NUMBER OF BEDROOMS; NUMBER OF BATHROOMS INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE, ROOF TYPE: DC;UBLE a TRIPLE ATTACHED U DETACHED = CARPORT Mi SIGNATURE OF APPLICANT' _ - ---`If ptaposdd work involves new comp Ial construction or facade improvements/renovations to an existing commercial property, building el4751ionsre required. 444♦♦♦11♦♦♦♦♦♦*4♦♦♦♦♦♦♦♦♦♦♦♦♦♦.... ♦+♦♦�♦♦♦♦♦�♦�♦♦♦t♦4♦*��♦ Off clal Use Only __ 3 -2Z — 0 pans Examiner Ohl •�IcnS� ge,��r� Zoning Official C ents. ES r NO 731- 8j a-3 Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls (3 Insulation R value of ceiling 1 (flat areas) .30 Insulation R value of ceiling 2 (vaulted areas/no attic) a 3. Glazing SHGC • 31 Glazing U-Factor • 7 0 R value of ductwork A/C SEER Rating / a.