CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER# d G _ 3 3 DATE: Izz low.
BUILDING ADDRESS:
I. Foundation Requirements
NA/ lk
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier la out shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
A'
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
CITY OF COLLEGE STATION
Planning 6 Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NA/
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
AIA
111. Stairway Requirements
K
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway mast have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
NA/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace re uires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning d Development Services
V. Electrical Service Requirements
N K
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
NNOW
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NAJMO
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
NA/
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
NAWKJ
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
A/
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
OK
Does not block any water course or divert any flow
Elevation certificate if required
CITY OF COLLEGE STATION
Planning d Development Services
Comments:
PLANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
3 - Z z—OG
DATE
0 REScheck Software Version 3.7 Release 1
8/"" Compliance Certificate
Project Title: 17151-Vaulted
Report Date: 03/09/06
Energy Code:
Location:
Construction Type:
Glazing Area Percentage:
Heating Degree Days:
Construction Site:
905 Whitewing Lane
College Station, TX
2003 IECC
Brazos County, Texas
Single Family
11%
1999
Owner/Agent:
D.R. Horton Austin
12554 Riata Vista Circle
Austin, TX 78727
512-345-4663
Designer/Contractor:
Permit #
Permit Date
Compliancew�Passes M9ximuiii7OA-590�Your Home UA: 519 12.01%6"BetteitThan Code (U—A)'-
Maximum SHGC: .0 '
Ceiling 1: Flat Ceiling or Scissor Truss:
Ceiling 2: Flat Ceiling or Scissor Truss:
Wall 1: Wood Frame, 16" o.c.:
Window 1: Metal Frame:Double Pane with Low-E:
SHGC: 0.36
Door 1: Solid:
Floor 1: Slab -On -Grade: Unheated: , Insulation Depth: 0.0'
Furnace 1: Forced Hot Air: 80 AFUE
Air Conditioner 1: Electric Central Air: 13 SEER
1316 30.0
0.0 46
400 22.0
0.0 18
1543 13.0
0.0 108
171
0.700 120
56
199
0.350 20
0.0 207
Compliance Statement. Statement of Compliance: The proposed building design described here is consistent with the building
plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet
the 2003 IECC requirements in REScheck Version 3.7 Release 1 and to comply with the mandatory requirements listed in the
REScheck Inspection Checklist.
Builder/Designer Company Name
Project Notes:
Water Heater: Gas
Date
17151-Vaulted
Page 1 of 4
CREScheck Software Version 3.7 Release 1
�(j Inspection Checklist
Date: 03/09/06
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
❑ Ceiling 2: Flat Ceiling or Scissor Truss, R-22.0 cavity insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
❑ Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.700
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1: Solid, U-factor: 0.350
Comments:
Floors:
❑ Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
Solar Heat Gain Coefficient:
❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be
determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed.
❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation.
Skylights:
❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-13.
Materials Identification:
❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment must be identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided.
❑ Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or
specifications.
Duct Insulation:
❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-8.
❑ Return ducts in unconditioned attics or outside the building must be insulated to R-4.
❑ Supply ducts in unconditioned spaces must be insulated to R-6.
17151-Vaulted
Page 2 of 4
❑ Return ducts in unconditioned spaces (except basements) must be insulated to R-2.
❑ Where exterior walls are used as plenums, the wall must be insulated to R-8.
❑ Insulation is not required on return ducts in basements.
Duct Construction:
❑ Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened.
❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181 B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500
Pa).
❑ The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the
heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral
heat trap or is part of a circulating system.
❑ Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
❑ Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from
non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table
2.
17151-Vaulted Page 3 of 4
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non -Circulating Runouts
Circulating Mains and
Runouts
Heated Water
Temperature (°F)
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-169
0.5
0.5
1.0
1.5
100-139
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Piping System Types
Fluid Temp.
Rangeff)
Heating Systems
Low Pressure/Temperature
201-250
Low Temperature
106-200
Steam Condensate (for feed water)
Any
Cooling Systems
Chilled Water, Refrigerant and
40-55
Brine
Below 40
NOTES TO FIELD: (Building Department Use Only)
Insulation Thickness in Inches by Pipe Sizes
2" Runouts 1" and Less 1.25" to 2.0" 2.5' to 4"
1.0
1.5
1.5
2.0
0.5
1.0
1.0
1.5
1.0
1.0
1.5
2.0
0.5
0.5
0.75
1.0
1.0
1.0
1.5
1.5
17151-Vaulted
Page 4 of 4
.'le,
Apr.11. 2006 11:19AM Strong Surveying No.1623 P. 6
1722 Broadmoo , Suite 105
TRONG � Texas 77802
Phony (979) 7y6-9836
URVEYING FAV (979) 731-0096
emak curtisostrongsurv*yingoom /
FORM CHECK
North Orientation is based on rotating The TBM Elevation Shown hereon is
the NorthEast line to the Plot Calls in based on the Grading Plan Prepared by
Volume 6968, Page 35. Texcon. SCALE: 1" = 20'
1/2" Iron Rod W/cap found at all comers,
unless otherwise noted.
All bearings and distances are Call and Actual. LEGEND
P.U.E. — Public Utility Esmt.
Grahom Road (70' ROW) F.F. — finished Floor
10' CITY OF BRYAN R.O.W. ESMT. (1764/8,11)
_ 10' GTE SOUTHWEST ESMT. (4003/1221
15' P.U.E. (6968/35)
20' Setback Line
II 1.3'
37.9'
I I
Z
I I
N
�I ly
m
O
A
UI 6th
O
p
a+ FORM O1 s
P F.F. 2 311.73' o
m
x I (310.4') f
IV
r r
,
N
O
LOT 2 cD
a N
LOT 3 I
LOT 4
I I
11.2' 19.3'
L
25' Setback Line
•N
:m
5' P.U.E. (6965/35)
S 41.55'21" W 60.56'
n RR u A Title Commitment was not
A a, available at the time of this
905 Wh i t e w i n g Lane survey, therefore only easements
jrQ „ shown on the Record Subdivision
3uFt BUYER' Plat are indicated on this plot.
33
Lot Three (3), Block One (1) of Dove Cross— ing Sub -division, an addition to
the City of College Station, Brazos County, TEXAS according to the plat recorded
in Volume 6968, Page 35 of the Official Records of Brazos County, Texas.
I, H. Curtis Strong, Registered Professional Land Surveyor No. 4961, do hereby certify that.
the above plat is true and correct and represents the results of a survey performed on the
ground under my supervision on April 3, 2005.
1 further certify that no improvements on this property encroach on adjacent property nor do
any improvements on adjacent property encroach on this property, except as shown. This
property is not located within a 100 — year flood hazard area as depicted from FLOOD
INSURANCE RATE MAP NO.48041CO201 C , DATED: JULY 2, 1992.
This Plat is copyrighted in 2006, rind is for the sole purpose of the buyer os shown,
Any other use is strictly prohibited without the express written consent of Strong Surveying, 19
PREPARED 8/22/06, 12:05:49 INSPECTION TICKET PAGE 13
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/22/06
------------------------------------------------------------------------------------------------
ADDRESS . : 905 WHITEWING LN SUBDIV: DOVE CROSSING
CONTRACTOR D R HORTON HOMES PHONE (512) 748-4017
OWNER . . PHONE
PARCEL . . 005401-0101-0030
APPL NUMBER: 06-00000833 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/13/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00
4/13/06 AP April 12, 2006 1:01:10 PM kwolfe
B115 01 5/22/06 DS BLDG, FRAMING TIME: 17:00
5/22/06 AE May 19, 2006 9:45:22 AM kwolfe
05/22/2006 11:40 AM DS PDA
fir down blocking around laundry room anchor bolts at
splices
B130 01 5/24/06 OC BLDG, INSULATION TIME: 17:00
5/24/06 DP May 24, 2006 11:01:41 AM bkorthauer
05/24/2006 03:38 PM OC PDA
thermo-ply needs 12inch o.c. nailing pattern and joints
taped.insulation stuffed
B13 02 5/26/06 RH BLDG, INSULATION TIME: 17:00
- 5/26/06 AP May 26, 2006 10:11:08 AM glsouth
B125 01 8/22/06 BI,, BLDG, FINAL TIME: 17:00
101,13 0(0 /w ►may'( August 22, 2006 8: 2 0: 2 6 AM kwolfe
-------------------------------------- COMMENTS AND NOTES ------------------
Kim Wolfe Re: Calling for CO @ 905 Whitewing Ln Page 1
From: Joe Garcia
To: Benjamin McCarty; Chris Haver; Gina Southerland; Kim Wolfe; Mitchell Carson;
Nicole Cochran; Paul Schoenfeld; Terry Boriskie
Date: 10/16/2006 12:19:40 PM
Suhject: Re: Calling for CO @ 905 Whitewing Ln
THIS ONE IS OK. JMG
>>> Nicole Cochran 10/13/06 12:48 PM >>>
Are there any issues?
BP# 06-833
Thanks!!
Nicole Cochran
CSR - Planning & Development
City of College Station
979.764.3570
www.cstx.gov
Date: 8/23/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 833
Address: 905 WHITEWING LN
Type
inspection Type Code
Description
Inssr tus
Inspection Result Comments
B115
BLDG, FRAMING
IC
05/22/2006 11:40 AM DS PDA
B115
BLDG, FRAMING
IC
fir down blocking around laundry room anchor bolts at
B115
BLDG, FRAMING
IC
splices
B130
BLDG, INSULATION
IC
05/24/2006 03:38 PM OC PDA
B130
BLDG, INSULATION
IC
thermo-ply needs 12inch o.c. nailing pattern and joints
B130
BLDG, INSULATION
IC
taped. insulation stuffed
M110
MECH, FINAL
IC
08/02/2006 04:38 PM RH PDA
M110
MECH, FINAL
IC
Flue pipe needs to be supported where it will maintain
M110
MECH, FINAL
IC
min. 1 in. clearance from combustibles. Need RTA grille
M110
MECH, FINAL
IC
and sheetrock /seal inside of RTA intake area.
Page 1
WF0756506 / 001 City of College Station
PAGE 1
REQ. DATE: 03/30/06 03/30/06 11:40:59
LOCATION: 905 WHITEWING LN LOC ID: 202790
REQUESTOR: D R HORTON HOMES ORIGIN: CUSTOMER -WALK IN
REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/30/06 SCHED COMPLETION: 03/30/06
********************************************************************************
JOB ORDER RESULT COMP EIS TS
WF0754912 / 001 City of College Station PAGE 1
REQ. DATE: 03/23/06 03/23/06 8:21:24
LOCATION: 905 WHITEWING LN `' LOC ID: 202790
REQUESTOR: D R HORTON ORIGIN: CUSTOMER -WALK IN
REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT
4" SEWER TAP AND 3/4" WATER TAP
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/23/06 SCHED COMPLETION: 03/23/06
********************************************************************************
JOB ORDER RESULT COMMENTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . • • • .
Parcel Number
Property Address
Subdivision Name
Legal Description
Property Zoning . . -
10/16/06
005401-0101-0030
905 WHITEWING LN TX 77845
COLLEGE STATION
DOVE CROSSING
DOVE CROSSING SUBDIVISION
PHASE 1A
BLK 1 LT 3
SINGLE FAMILY RESIDENTIAL
wn
Contractor . . . . . . D R HORTON HOMES
512 748-4017
rpplication number 06-00000833 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . • • • .
Approved
' . . 4B;! !VngOfficial
VOID UNLESS SIGNED BY BUILDING OFFICIAL
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 T�XASAVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 06+00000833 Date 3/22/06
Property Address . .
. . . . 905 WHITEWING LN
Property ID . . . . .
. . . . 005401-0101-0030
R ##
R13907
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . DOVE CROSSING
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 113190
Owner
Contractor
------------------------
------------------------
D R HORTON HOMES
12554 RIATTA VISTA CIRCLE
SECOND FLOOR
AUSTIN TX 78727
(512) 748-4017
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1715.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 405.00
----------------------------------------------------------------------------
Permit
BUILDING PERMIT
Additional desc
GS
Permit Fee . . . .
502.00 Plan Check Fee .00
Issue Date . . . .
3/22/06 Valuation . . . . 113190
Expiration Date . .
9/18/06
Qty Unit Charge
Per Extension
BASE FEE 460.00
14.00 3.0000
THOU BLDG, VAL 100001-500000 42.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
------------------------------------------ --- -'------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 'TEXAS, AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 06-00000833 Date 3/22/06
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
------------------------------------------- A//--- <_4�------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS, AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number 06-00000833
Page 3
Date 3/22/06
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
BUILDING DEPT REPRESENTATIVA
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS, AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number
. . . . .
06-00000833
Date 3/22/06
----------------------------------------------------------------------------
Special Notes and
Comments
PRIVATE GARAGES
Engineered wind bracing
methods
used.
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
--------------------
Due
----------
-----------------
Permit Fee Total
502.00
502.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1252.00
1252.00
.00
.00
R
BUILDING DEPT REPRESENTATPZE
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS.AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
. . . . .
06-00000834 Date 3/22/06
Property Address
. . . . . .
905 WHITEWING LN
Property ID
005401-0101-0030
R #
R13907
Application type description
TEMP POLE
Subdivision Name .
. . . . .
DOVE CROSSING
Property Use . . .
. . . . .
RESIDENTIAL
Property Zoning . .
. . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
------------------------
D R HORTON HOMES
12554 RIATTA VISTA
CIRCLE
SECOND FLOOR
AUSTIN
TX 78727
(512) 748-4017
----------------------------------------------------------------------------
Permit
TEMP POLE
PERMIT
Additional desc
GS
Permit Fee . . . .
20.00
Issue Date
3/22/06
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . . .
. . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 - - - - - - - -
- - - - - - - - - - - - - - - -
BUILDING DEPT REPRESENTATIVE:- - \
APPLICANT:
iIAY-19-20PI 02:21 From:
a >_
To:512 21e 4299 P.3/4
APPLICATION FOR BUILDINd PERMIT DATE: .J ct�REG
CITY OF COLLEGE STATION APPLICATION b - DJ
1101 TEXAS AVENUE _ C
COLLEGE STATION, TX 77840 TEMP POLE # D 3�
Xam�
CITY d COLLECC STAI'u7N (979) 784-3570 (979) 764..a48B rAX
Plirrd dr' CJerxlopment SnwiYt
W W W.CSTX.GOV
ADDRESS/LOCATION: �05— Gt�'G(il/j%
LOT e.00/ BLOCK (/SUBDIVISION o �J o SEC/PH
BUSINESS/OWNER NAME: ) 15th PHONE:,51 *_L- 533 -1 `l 0_�-
CONTRACTOR/HOMEOWNER: _,11R. `T :n PHONE: -a;L- 5 3 3 - /ivy
CONTRACTOR ADDRESS: Ia `l-rC 1a-- ksL 7-ix 7�'
ELECTRICIAN:Z'� 6 �d3PLUMBER: 0' ch" io'e, % 731-
/l 3
HVAC: - GOOD CENTS (Residentlal only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION ` SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION' SWIMMING POOL
Required)
DESCRIPTION OF WORK:
STRUCTURE USE:
HOMEOWNER ASS OCIATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL'
TEXAS ACCESSIBILITY STANDARD (T ) PROJECT REGISTRATION# EABPRJ
VALUATION: $ I 1 3 I TOTAL AREA:2-3 3 3 HEATED AREA: I `7 1 5
(Cost of labor and Materials)
D PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
1!
WER TAP:
WATER TAP:
SqD
OTHER TAP;
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE;
TEMP POLE -- - -- ROOF TYPE. -
GARAGE TYPE: SINGLE a DOUBLE � TRIPLE
ATTACHED ff DETACHED F__j CARPORT a
SIGNATURE OF APPLICANT'
�- `If proposed work involves new comn la) construction or facade improvements/renovations to an existing
commercial property, building el4v'allons re required.
Of/icla/ Use Only
1 -2?'O6
jPI-ins Examiner
Zoning Official
C ents:
ES r-NO.
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating