Loading...
HomeMy WebLinkAboutRES2006-00833, 06-834OPendaftenr /3Esselte R 7521/3 10% P4 e CITY OF COLLEGE STATION Planning & Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLAN REVIEW/PERMIT NUMBER# d G _ 3 3 DATE: Izz low. BUILDING ADDRESS: I. Foundation Requirements NA/ lk A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier la out shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated A' II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. CITY OF COLLEGE STATION Planning 6 Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NA/ 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes AIA 111. Stairway Requirements K A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway mast have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) NA/ A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace re uires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning d Development Services V. Electrical Service Requirements N K A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements NNOW A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NAJMO A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements NA/ A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 NAWKJ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements A/ Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required CITY OF COLLEGE STATION Planning d Development Services Comments: PLANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS 3 - Z z—OG DATE 0 REScheck Software Version 3.7 Release 1 8/"" Compliance Certificate Project Title: 17151-Vaulted Report Date: 03/09/06 Energy Code: Location: Construction Type: Glazing Area Percentage: Heating Degree Days: Construction Site: 905 Whitewing Lane College Station, TX 2003 IECC Brazos County, Texas Single Family 11% 1999 Owner/Agent: D.R. Horton Austin 12554 Riata Vista Circle Austin, TX 78727 512-345-4663 Designer/Contractor: Permit # Permit Date Compliancew�Passes M9ximuiii7OA-590�Your Home UA: 519 12.01%6"BetteitThan Code (U—A)'- Maximum SHGC: .0 ' Ceiling 1: Flat Ceiling or Scissor Truss: Ceiling 2: Flat Ceiling or Scissor Truss: Wall 1: Wood Frame, 16" o.c.: Window 1: Metal Frame:Double Pane with Low-E: SHGC: 0.36 Door 1: Solid: Floor 1: Slab -On -Grade: Unheated: , Insulation Depth: 0.0' Furnace 1: Forced Hot Air: 80 AFUE Air Conditioner 1: Electric Central Air: 13 SEER 1316 30.0 0.0 46 400 22.0 0.0 18 1543 13.0 0.0 108 171 0.700 120 56 199 0.350 20 0.0 207 Compliance Statement. Statement of Compliance: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 3.7 Release 1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer Company Name Project Notes: Water Heater: Gas Date 17151-Vaulted Page 1 of 4 CREScheck Software Version 3.7 Release 1 �(j Inspection Checklist Date: 03/09/06 Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: ❑ Ceiling 2: Flat Ceiling or Scissor Truss, R-22.0 cavity insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: ❑ Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.700 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1: Solid, U-factor: 0.350 Comments: Floors: ❑ Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Solar Heat Gain Coefficient: ❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Skylights: ❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-13. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-8. ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-4. ❑ Supply ducts in unconditioned spaces must be insulated to R-6. 17151-Vaulted Page 2 of 4 ❑ Return ducts in unconditioned spaces (except basements) must be insulated to R-2. ❑ Where exterior walls are used as plenums, the wall must be insulated to R-8. ❑ Insulation is not required on return ducts in basements. Duct Construction: ❑ Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened. ❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181 B. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. 17151-Vaulted Page 3 of 4 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non -Circulating Runouts Circulating Mains and Runouts Heated Water Temperature (°F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Piping System Types Fluid Temp. Rangeff) Heating Systems Low Pressure/Temperature 201-250 Low Temperature 106-200 Steam Condensate (for feed water) Any Cooling Systems Chilled Water, Refrigerant and 40-55 Brine Below 40 NOTES TO FIELD: (Building Department Use Only) Insulation Thickness in Inches by Pipe Sizes 2" Runouts 1" and Less 1.25" to 2.0" 2.5' to 4" 1.0 1.5 1.5 2.0 0.5 1.0 1.0 1.5 1.0 1.0 1.5 2.0 0.5 0.5 0.75 1.0 1.0 1.0 1.5 1.5 17151-Vaulted Page 4 of 4 .'le, Apr.11. 2006 11:19AM Strong Surveying No.1623 P. 6 1722 Broadmoo , Suite 105 TRONG � Texas 77802 Phony (979) 7y6-9836 URVEYING FAV (979) 731-0096 emak curtisostrongsurv*yingoom / FORM CHECK North Orientation is based on rotating The TBM Elevation Shown hereon is the NorthEast line to the Plot Calls in based on the Grading Plan Prepared by Volume 6968, Page 35. Texcon. SCALE: 1" = 20' 1/2" Iron Rod W/cap found at all comers, unless otherwise noted. All bearings and distances are Call and Actual. LEGEND P.U.E. — Public Utility Esmt. Grahom Road (70' ROW) F.F. — finished Floor 10' CITY OF BRYAN R.O.W. ESMT. (1764/8,11) _ 10' GTE SOUTHWEST ESMT. (4003/1221 15' P.U.E. (6968/35) 20' Setback Line II 1.3' 37.9' I I Z I I N �I ly m O A UI 6th O p a+ FORM O1 s P F.F. 2 311.73' o m x I (310.4') f IV r r , N O LOT 2 cD a N LOT 3 I LOT 4 I I 11.2' 19.3' L 25' Setback Line •N :m 5' P.U.E. (6965/35) S 41.55'21" W 60.56' n RR u A Title Commitment was not A a, available at the time of this 905 Wh i t e w i n g Lane survey, therefore only easements jrQ „ shown on the Record Subdivision 3uFt BUYER' Plat are indicated on this plot. 33 Lot Three (3), Block One (1) of Dove Cross— ing Sub -division, an addition to the City of College Station, Brazos County, TEXAS according to the plat recorded in Volume 6968, Page 35 of the Official Records of Brazos County, Texas. I, H. Curtis Strong, Registered Professional Land Surveyor No. 4961, do hereby certify that. the above plat is true and correct and represents the results of a survey performed on the ground under my supervision on April 3, 2005. 1 further certify that no improvements on this property encroach on adjacent property nor do any improvements on adjacent property encroach on this property, except as shown. This property is not located within a 100 — year flood hazard area as depicted from FLOOD INSURANCE RATE MAP NO.48041CO201 C , DATED: JULY 2, 1992. This Plat is copyrighted in 2006, rind is for the sole purpose of the buyer os shown, Any other use is strictly prohibited without the express written consent of Strong Surveying, 19 PREPARED 8/22/06, 12:05:49 INSPECTION TICKET PAGE 13 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/22/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 905 WHITEWING LN SUBDIV: DOVE CROSSING CONTRACTOR D R HORTON HOMES PHONE (512) 748-4017 OWNER . . PHONE PARCEL . . 005401-0101-0030 APPL NUMBER: 06-00000833 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/13/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00 4/13/06 AP April 12, 2006 1:01:10 PM kwolfe B115 01 5/22/06 DS BLDG, FRAMING TIME: 17:00 5/22/06 AE May 19, 2006 9:45:22 AM kwolfe 05/22/2006 11:40 AM DS PDA fir down blocking around laundry room anchor bolts at splices B130 01 5/24/06 OC BLDG, INSULATION TIME: 17:00 5/24/06 DP May 24, 2006 11:01:41 AM bkorthauer 05/24/2006 03:38 PM OC PDA thermo-ply needs 12inch o.c. nailing pattern and joints taped.insulation stuffed B13 02 5/26/06 RH BLDG, INSULATION TIME: 17:00 - 5/26/06 AP May 26, 2006 10:11:08 AM glsouth B125 01 8/22/06 BI,, BLDG, FINAL TIME: 17:00 101,13 0(0 /w ►may'( August 22, 2006 8: 2 0: 2 6 AM kwolfe -------------------------------------- COMMENTS AND NOTES ------------------ Kim Wolfe Re: Calling for CO @ 905 Whitewing Ln Page 1 From: Joe Garcia To: Benjamin McCarty; Chris Haver; Gina Southerland; Kim Wolfe; Mitchell Carson; Nicole Cochran; Paul Schoenfeld; Terry Boriskie Date: 10/16/2006 12:19:40 PM Suhject: Re: Calling for CO @ 905 Whitewing Ln THIS ONE IS OK. JMG >>> Nicole Cochran 10/13/06 12:48 PM >>> Are there any issues? BP# 06-833 Thanks!! Nicole Cochran CSR - Planning & Development City of College Station 979.764.3570 www.cstx.gov Date: 8/23/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 833 Address: 905 WHITEWING LN Type inspection Type Code Description Inssr tus Inspection Result Comments B115 BLDG, FRAMING IC 05/22/2006 11:40 AM DS PDA B115 BLDG, FRAMING IC fir down blocking around laundry room anchor bolts at B115 BLDG, FRAMING IC splices B130 BLDG, INSULATION IC 05/24/2006 03:38 PM OC PDA B130 BLDG, INSULATION IC thermo-ply needs 12inch o.c. nailing pattern and joints B130 BLDG, INSULATION IC taped. insulation stuffed M110 MECH, FINAL IC 08/02/2006 04:38 PM RH PDA M110 MECH, FINAL IC Flue pipe needs to be supported where it will maintain M110 MECH, FINAL IC min. 1 in. clearance from combustibles. Need RTA grille M110 MECH, FINAL IC and sheetrock /seal inside of RTA intake area. Page 1 WF0756506 / 001 City of College Station PAGE 1 REQ. DATE: 03/30/06 03/30/06 11:40:59 LOCATION: 905 WHITEWING LN LOC ID: 202790 REQUESTOR: D R HORTON HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/30/06 SCHED COMPLETION: 03/30/06 ******************************************************************************** JOB ORDER RESULT COMP EIS TS WF0754912 / 001 City of College Station PAGE 1 REQ. DATE: 03/23/06 03/23/06 8:21:24 LOCATION: 905 WHITEWING LN `' LOC ID: 202790 REQUESTOR: D R HORTON ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT 4" SEWER TAP AND 3/4" WATER TAP TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/23/06 SCHED COMPLETION: 03/23/06 ******************************************************************************** JOB ORDER RESULT COMMENTS City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . • • • . Parcel Number Property Address Subdivision Name Legal Description Property Zoning . . - 10/16/06 005401-0101-0030 905 WHITEWING LN TX 77845 COLLEGE STATION DOVE CROSSING DOVE CROSSING SUBDIVISION PHASE 1A BLK 1 LT 3 SINGLE FAMILY RESIDENTIAL wn Contractor . . . . . . D R HORTON HOMES 512 748-4017 rpplication number 06-00000833 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . • • • . Approved ' . . 4B;! !VngOfficial VOID UNLESS SIGNED BY BUILDING OFFICIAL BUILDING PERMIT CITY OF COLLEGE STATION 1101 T�XASAVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06+00000833 Date 3/22/06 Property Address . . . . . . 905 WHITEWING LN Property ID . . . . . . . . . 005401-0101-0030 R ## R13907 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . DOVE CROSSING Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 113190 Owner Contractor ------------------------ ------------------------ D R HORTON HOMES 12554 RIATTA VISTA CIRCLE SECOND FLOOR AUSTIN TX 78727 (512) 748-4017 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1715.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc GS Permit Fee . . . . 502.00 Plan Check Fee .00 Issue Date . . . . 3/22/06 Valuation . . . . 113190 Expiration Date . . 9/18/06 Qty Unit Charge Per Extension BASE FEE 460.00 14.00 3.0000 THOU BLDG, VAL 100001-500000 42.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) ------------------------------------------ --- -'------------------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 'TEXAS, AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 06-00000833 Date 3/22/06 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE ------------------------------------------- A//--- <_4�------------------------ BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS, AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number 06-00000833 Page 3 Date 3/22/06 Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN BUILDING DEPT REPRESENTATIVA APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS, AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00000833 Date 3/22/06 ---------------------------------------------------------------------------- Special Notes and Comments PRIVATE GARAGES Engineered wind bracing methods used. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited -------------------- Due ---------- ----------------- Permit Fee Total 502.00 502.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1252.00 1252.00 .00 .00 R BUILDING DEPT REPRESENTATPZE APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS.AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000834 Date 3/22/06 Property Address . . . . . . 905 WHITEWING LN Property ID 005401-0101-0030 R # R13907 Application type description TEMP POLE Subdivision Name . . . . . . DOVE CROSSING Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ D R HORTON HOMES 12554 RIATTA VISTA CIRCLE SECOND FLOOR AUSTIN TX 78727 (512) 748-4017 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc GS Permit Fee . . . . 20.00 Issue Date 3/22/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 - - - - - - - - - - - - - - - - - - - - - - - - BUILDING DEPT REPRESENTATIVE:- - \ APPLICANT: iIAY-19-20PI 02:21 From: a >_ To:512 21e 4299 P.3/4 APPLICATION FOR BUILDINd PERMIT DATE: .J ct�REG CITY OF COLLEGE STATION APPLICATION b - DJ 1101 TEXAS AVENUE _ C COLLEGE STATION, TX 77840 TEMP POLE # D 3� Xam� CITY d COLLECC STAI'u7N (979) 784-3570 (979) 764..a48B rAX Plirrd dr' CJerxlopment SnwiYt W W W.CSTX.GOV ADDRESS/LOCATION: �05— Gt�'G(il/j% LOT e.00/ BLOCK (/SUBDIVISION o �J o SEC/PH BUSINESS/OWNER NAME: ) 15th PHONE:,51 *_L- 533 -1 `l 0_�- CONTRACTOR/HOMEOWNER: _,11R. `T :n PHONE: -a;L- 5 3 3 - /ivy CONTRACTOR ADDRESS: Ia `l-rC 1a-- ksL 7-ix 7�' ELECTRICIAN:Z'� 6 �d3PLUMBER: 0' ch" io'e, % 731- /l 3 HVAC: - GOOD CENTS (Residentlal only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION ` SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION' SWIMMING POOL Required) DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASS OCIATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL' TEXAS ACCESSIBILITY STANDARD (T ) PROJECT REGISTRATION# EABPRJ VALUATION: $ I 1 3 I TOTAL AREA:2-3 3 3 HEATED AREA: I `7 1 5 (Cost of labor and Materials) D PUBLIC SEWER SEPTIC/TREATMENT SYSTEM 1! WER TAP: WATER TAP: SqD OTHER TAP; NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE; TEMP POLE -- - -- ROOF TYPE. - GARAGE TYPE: SINGLE a DOUBLE � TRIPLE ATTACHED ff DETACHED F__j CARPORT a SIGNATURE OF APPLICANT' �- `If proposed work involves new comn la) construction or facade improvements/renovations to an existing commercial property, building el4v'allons re required. Of/icla/ Use Only 1 -2?'O6 jPI-ins Examiner Zoning Official C ents: ES r-NO. Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating