HomeMy WebLinkAboutRES2006-00831, 06-832r_,
f
OPendaflenr
OEss &
R 7521/3 10% P4
J
PREPARED 8/22/06, 12:05:49 INSPECTION TICKET PAGE 12
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/22/06
------------------------------------------------------------------------------------------------
ADDRESS . : 911 WHITEWING LN SUBDIV: DOVE CROSSING
CONTRACTOR D R HORTON HOMES PHONE (512) 748-4017
OWNER . . PHONE
PARCEL . . 005401-0101-0060
APPL NUMBER: 06-00000831 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/11/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00
4/11/06 AP T/S: 04/10/2006 10:39 AM GLSOUTH -----------------------
morning
04/11/2006 12:01 PM RH PDA
Slab ground installed. Slab survey on file.
B115 01 5/19/06 OC BLDG, FRAMING TIME: 17:00
5/19/06 AP May 19, 2006 9:43:38 AM kwolfe
B130 01 5/23/06 OC BLDG, INSULATION TIME: 17:00
5/23/06 AP May 22, 2006 2:59:25 PM glsouth
B125 01 8122J06 I BLDG, FINAL TIME: 17:00
OCR VT � OC August 22, 2006 8:21:12 AM kwolfe
-------------------------------------- COMMENTS AND NOTES--------------------------------------
TC, 2�.o r+ IS I ��
f �
U 11 U . 01AW
Date: 8/22/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 831
Address: 911 WHITEWING LN
Type
Inspection Type Code
Description
si ips
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
04/11/2006 12:01 PM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Slab ground installed. Slab survey on file.
E110
ELEC, ROUGH IN
IC
05/18/2006 10:30 AM RH PDA
E110
ELEC, ROUGH IN
IC
Need to connect slab ground, wires loose in garage at a/c
E110
ELEC, ROUGH IN
IC
return air closet.
M110
MECH, FINAL
IC
07/03/2006 11:43 AM RH PDA
M110
MECH, FINAL
IC
Before building final a min. 1 in of clearance is needed
M110
MECH, FINAL
IC
at furnace flue from combustibles. No foam sealant.
P100
PLBG, ROUGH IN
IC
March 31, 2006 3:35:44 PM bkorthauer
Page 1
Apr.11. 2006 11;20AM Strang Surveying
No.1623 P. 9
1722 Broadmoo, StAe 165 Ift
TRONG �979 986
URVEYING Fax (979) r".0096
7 emaFt curt!sosaonssurva*&C0m
FORM CHECK
North Orientation is based on rotating The TBM Elevation Shown hereon is
the North East line to the Plat Calls in based on the Grading Plan Prepared by
Volume 6968, Page 35. Texcon. SCALE: 1" -- 20'
1/2" Iron Rod W/cap found at all corners,
unless otherwise noted. LEGEND
All bearings and distances are Call and Actual.
P.U.E. — Public Utility Esmt.
Graham Road (70' ROW' F.F. — finished Floor
10' City of Bryan R.O.W. Esmt.11764/8,11)
10' GTE Southwest Estnt.14063/122)
_15' P.U.E.16968/35)
:M
20' Building Setback :N
ro Q
................
21.8' 6.r '
z
�
v,
Lot 6
N
a
Am
`"
m
m
Ci
Lot 5
a I
I�
Lot 7
e
o+ FORM m
m
F.F. = 311.63'
0
o
m
m
MIn. F.F. = 309.4'
O
a
F
—
I
9.6-
O
�
28.3' �
_
25' Building Setback
N
U:
5.0' P.U.E.16968/351
W 60.56'
911 Whitewing Lane
A Title Commitment was not
available at the time of this
survey, therefore only easements
'shown on the Record Subdivision
Plat are Indicated on this plot.
BUYER:
Lot Six(6), Block One(1) of Dove Crossing Subdivision, an addition to
the City of College Station, Brazos County, TEXAS according to the plat recorded
in Volume 6968, Page 35 of the Official Records of Brazos County,' Texas.
I, H. Curtis Strong, Registered Professional Land Surveyor No. 4961, do hereby certify that
the above plat is true and correct and represents the results of a survey performed on the
ground under my supervision on April 10, 2006.
1 further certify that no improvements on this property encroach on adjacent property nor do
any improvements on adjacent property encroach on this property, except as shown. This
property is not located within a 100 — year flood hazard area as depicted from FLOOD
INSURANCE RATE MAP NO.48041CO201 C , DATED: JULY 2, 1992.
This Plat is copyrighted in 2006, and is for the sole purpose of the buyer as shown.
Any other use is strictly prohibited without the express written consent of Strong Survey'1ng.
WF0754905 / 001 City of College Station
PAGE 1
REQ. DATE:
03/23/06
'' 03/23/06
8:18:41
LOCATION:
911 WHITEWING LN
LOC ID:
202796
REQUESTOR:
D R HORTON
ORIGIN: CUSTOMER -WALK IN
REQ. USER:
BKORTHAUER AUTH. USER:
BKORTHAUER WORK TYPE:
ROUT
4" SEWER
TAP AND 3/4" WATER TAP
TASK:
SET UP NEW UTILITY ACCT
SET-, READY
SCHED START:
03/23/06 SCHED
COMPLETION:
03/23/06
********************************************************************************
JOB ORDER RESULT COMIE TS
CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER#
_83�
DATE: 3 /ate/o6
BUILDING ADDRESS:
w,
J
I. Foundation Requirements
NA/
A. Concrete minimum f c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
n
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NA/
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
111. Stairway Requirements
NA/
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six (6-6") inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
NAJOV
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
planning d' Development Services
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
VIII. Energy Requirements
N
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
NA/
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
OK
Does not block any water course or divert any flow
Elevation certificate if required
CITY OF COLLEGE STATION
Planning cr Development Services
Comments:
J/� �-, 1. 1 —6-1
L NS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
3 - Z_Z - aA
DATE
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STAT!'O1 ,- "1'X 77840
PHONE: (979)764-3570 FAX: (979)764-3496
------------------------------------------ `----------------------------------�
Application Number . . . . . 06-00000831 Date 3/22/06
Property Address . . . . . . 911 WHITEWING LN
Property ID 005401-0101-0060
R ## R13907
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . DOVE CROSSING
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 113190
Owner Contractor
------------------------ ------------------------
D R HORTON HOMES
12554 RIATTA VISTA CIRCLE
SECOND FLOOR
AUSTIN TX 78727
(512) 748-4017
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1715.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 405.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit Fee . . . . 502.00 Plan Check Fee .00
Issue Date . . . . 3/22/06 Valuation . . . . 113190
Expiration Date . . 9/18/06
Qty Unit Charge Per Extension
BASE FEE 460.00
14.00 3.0000 THOU BLDG, VAL 100001-500000 42.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
----------------------------- - --`L
----------------------
BUILDING DEPT REPRESENTATIVjE.
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, tX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000831
Page 2
Date 3/22/06
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
------------------ --- - - --- - �----------------------
BUILDING DEPT REPRESENTATIVE: ---
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, tX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000831
Page 3
Date 3/22/06
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - / 1- H - - - - - Y fr - - - - - - - - _ _ _ - - - - - _ _ _ _ _ - - - -
BUILDING DEPT REPRESENTA'
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, tX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number
. . . . .
06-00000831
Date 3/22/06
----------------------------------------------------------------------------
Special Notes and
Comments
PRIVATE GARAGES
Engineered wall bracing
used.
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
--------------------
Due
----------
-----------------
Permit Fee Total
----------
502.00
502.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1252.00
1252.00
.00
.00
- - - - - - - - - - - - - - - - - - - - - - --------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, tX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
. . . . .
06-00000832 Date 3/22/06
Property Address .
. . . . .
911 WHITEWING LN
Property ID
005401-0101-0060
R $#
R13907
Application type description
TEMP POLE
Subdivision Name .
. . . . .
DOVE CROSSING
Property Use . . .
. . . . .
RESIDENTIAL
Property Zoning . .
. . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
------------------------
D R HORTON HOMES
12554 RIATTA VISTA
CIRCLE
SECOND FLOOR
AUSTIN
TX 78727
(512) 748-4017
----------------------------------------------------------------------------
Permit
TEMP POLE
PERMIT
Additional desc
GS
Permit Fee . . . .
20.00
Issue Date . . . .
3/22/06
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . . .
. . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
BUILDING DEPT REPRESENTATIVE: �7
APPLICANT:
my-18.,?004 02:21 from:
w
CM OF COLLBCG S'i-A oN
P"ihd c' Dnylgmew Servim
ADDRESS/LOCATION-
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764.3496 FAX
WWW.CSTX.GOV
��// 01&z5'011k6#
To:512 21e 4299 P.3/4
" For omce �U- oiay
DATA: I d �L1� 17FF REG
)�
APPUCATION �# l 9 -1 12)
TEMP POLE
LOT ---J� "`OCK SUBDIVISION O �J SEC/PH_��
BUSINESS/OWNER NAME'—,Im UOn PHONE:, - 533 -lK 0_�-
CONTRACTOR/HOMEOWNER: rlR_i_L�1'M _n PHONE: 51a - 53 3 - l iv�7
CONTRACTOR ADDRESS: I�.S, y XFti /-'� Uf1/-.� 7x ?8 -�a7
ELECTRICIAN: rfddCus PLUMBER �QSS �(�/m�i1•q f �o/�V�� 731-
HVAC: - GOOD CENTS (Rosldentlalonly):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION = SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION' SWIMMING POOL
Required) n 1 t
DESCRIPTION OF WORK: PI\0� �oV_U4_
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS PROJECT REGISTRATION# EABPRJ
VALUATION: $ V 3. TOTAL_ AREA: z'3 20 HEATED AREA:
(Cost of Labor and Materials)
D PUBLIC SEWER
SEPTIC%TREATMENT SYSTEM
SEWER TAP: Lis)
SIZE WATER TAP: y 3 ct1
SAE
7 OTHER TAP:
TEMP POLE
GARAGE TYPE:
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE;
-- — - Slims------------ ---------- _ -- - - --
ROOF TYPE'
SINGLE a - DOUBLE TRIPLE
ATTACHED Efl— DETACHED CARPORT a
SIGNATURE OF APPLICANT' z (J
- IF proposed work invoives new comn lal construction or facade improvements/renovations to an existing
commercial property, building ell aions re required.
Officlal Use Only
9 -zz -0(o
�./�Ia�n s Examiner
Zoning Official
ants:
YI=S r NO
a^ w
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls 3
Insulation R value of ceiling 1 (flat areas) 30
Insulation R value of ceiling 2 (vaulted areas/no attic) 4�t ;k
Glazing SHGC
Glazing U-Factor 10
R value of ductwork
A/C SEER Rating