Loading...
HomeMy WebLinkAboutRES2006-00831, 06-832r_, f OPendaflenr OEss & R 7521/3 10% P4 J PREPARED 8/22/06, 12:05:49 INSPECTION TICKET PAGE 12 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/22/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 911 WHITEWING LN SUBDIV: DOVE CROSSING CONTRACTOR D R HORTON HOMES PHONE (512) 748-4017 OWNER . . PHONE PARCEL . . 005401-0101-0060 APPL NUMBER: 06-00000831 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/11/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00 4/11/06 AP T/S: 04/10/2006 10:39 AM GLSOUTH ----------------------- morning 04/11/2006 12:01 PM RH PDA Slab ground installed. Slab survey on file. B115 01 5/19/06 OC BLDG, FRAMING TIME: 17:00 5/19/06 AP May 19, 2006 9:43:38 AM kwolfe B130 01 5/23/06 OC BLDG, INSULATION TIME: 17:00 5/23/06 AP May 22, 2006 2:59:25 PM glsouth B125 01 8122J06 I BLDG, FINAL TIME: 17:00 OCR VT � OC August 22, 2006 8:21:12 AM kwolfe -------------------------------------- COMMENTS AND NOTES-------------------------------------- TC, 2�.o r+ IS I �� f � U 11 U . 01AW Date: 8/22/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 831 Address: 911 WHITEWING LN Type Inspection Type Code Description si ips Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC 04/11/2006 12:01 PM RH PDA B100 BLDG, FOUNDATION -SLAB IC Slab ground installed. Slab survey on file. E110 ELEC, ROUGH IN IC 05/18/2006 10:30 AM RH PDA E110 ELEC, ROUGH IN IC Need to connect slab ground, wires loose in garage at a/c E110 ELEC, ROUGH IN IC return air closet. M110 MECH, FINAL IC 07/03/2006 11:43 AM RH PDA M110 MECH, FINAL IC Before building final a min. 1 in of clearance is needed M110 MECH, FINAL IC at furnace flue from combustibles. No foam sealant. P100 PLBG, ROUGH IN IC March 31, 2006 3:35:44 PM bkorthauer Page 1 Apr.11. 2006 11;20AM Strang Surveying No.1623 P. 9 1722 Broadmoo, StAe 165 Ift TRONG �979 986 URVEYING Fax (979) r".0096 7 emaFt curt!sosaonssurva*&C0m FORM CHECK North Orientation is based on rotating The TBM Elevation Shown hereon is the North East line to the Plat Calls in based on the Grading Plan Prepared by Volume 6968, Page 35. Texcon. SCALE: 1" -- 20' 1/2" Iron Rod W/cap found at all corners, unless otherwise noted. LEGEND All bearings and distances are Call and Actual. P.U.E. — Public Utility Esmt. Graham Road (70' ROW' F.F. — finished Floor 10' City of Bryan R.O.W. Esmt.11764/8,11) 10' GTE Southwest Estnt.14063/122) _15' P.U.E.16968/35) :M 20' Building Setback :N ro Q ................ 21.8' 6.r ' z � v, Lot 6 N a Am `" m m Ci Lot 5 a I I� Lot 7 e o+ FORM m m F.F. = 311.63' 0 o m m MIn. F.F. = 309.4' O a F — I 9.6- O � 28.3' � _ 25' Building Setback N U: 5.0' P.U.E.16968/351 W 60.56' 911 Whitewing Lane A Title Commitment was not available at the time of this survey, therefore only easements 'shown on the Record Subdivision Plat are Indicated on this plot. BUYER: Lot Six(6), Block One(1) of Dove Crossing Subdivision, an addition to the City of College Station, Brazos County, TEXAS according to the plat recorded in Volume 6968, Page 35 of the Official Records of Brazos County,' Texas. I, H. Curtis Strong, Registered Professional Land Surveyor No. 4961, do hereby certify that the above plat is true and correct and represents the results of a survey performed on the ground under my supervision on April 10, 2006. 1 further certify that no improvements on this property encroach on adjacent property nor do any improvements on adjacent property encroach on this property, except as shown. This property is not located within a 100 — year flood hazard area as depicted from FLOOD INSURANCE RATE MAP NO.48041CO201 C , DATED: JULY 2, 1992. This Plat is copyrighted in 2006, and is for the sole purpose of the buyer as shown. Any other use is strictly prohibited without the express written consent of Strong Survey'1ng. WF0754905 / 001 City of College Station PAGE 1 REQ. DATE: 03/23/06 '' 03/23/06 8:18:41 LOCATION: 911 WHITEWING LN LOC ID: 202796 REQUESTOR: D R HORTON ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT 4" SEWER TAP AND 3/4" WATER TAP TASK: SET UP NEW UTILITY ACCT SET-, READY SCHED START: 03/23/06 SCHED COMPLETION: 03/23/06 ******************************************************************************** JOB ORDER RESULT COMIE TS CITY OF COLLEGE STATION Planning & Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLAN REVIEW/PERMIT NUMBER# _83� DATE: 3 /ate/o6 BUILDING ADDRESS: w, J I. Foundation Requirements NA/ A. Concrete minimum f c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS n II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NA/ 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes 111. Stairway Requirements NA/ A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six (6-6") inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) NAJOV A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION planning d' Development Services V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) VIII. Energy Requirements N A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements NA/ Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required CITY OF COLLEGE STATION Planning cr Development Services Comments: J/� �-, 1. 1 —6-1 L NS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS 3 - Z_Z - aA DATE BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STAT!'O1 ,- "1'X 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ------------------------------------------ `----------------------------------� Application Number . . . . . 06-00000831 Date 3/22/06 Property Address . . . . . . 911 WHITEWING LN Property ID 005401-0101-0060 R ## R13907 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . DOVE CROSSING Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 113190 Owner Contractor ------------------------ ------------------------ D R HORTON HOMES 12554 RIATTA VISTA CIRCLE SECOND FLOOR AUSTIN TX 78727 (512) 748-4017 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1715.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit Fee . . . . 502.00 Plan Check Fee .00 Issue Date . . . . 3/22/06 Valuation . . . . 113190 Expiration Date . . 9/18/06 Qty Unit Charge Per Extension BASE FEE 460.00 14.00 3.0000 THOU BLDG, VAL 100001-500000 42.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) ----------------------------- - --`L ---------------------- BUILDING DEPT REPRESENTATIVjE. APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, tX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000831 Page 2 Date 3/22/06 Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE ------------------ --- - - --- - �---------------------- BUILDING DEPT REPRESENTATIVE: --- APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, tX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000831 Page 3 Date 3/22/06 Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - / 1- H - - - - - Y fr - - - - - - - - _ _ _ - - - - - _ _ _ _ _ - - - - BUILDING DEPT REPRESENTA' APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, tX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00000831 Date 3/22/06 ---------------------------------------------------------------------------- Special Notes and Comments PRIVATE GARAGES Engineered wall bracing used. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited -------------------- Due ---------- ----------------- Permit Fee Total ---------- 502.00 502.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1252.00 1252.00 .00 .00 - - - - - - - - - - - - - - - - - - - - - - -------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, tX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000832 Date 3/22/06 Property Address . . . . . . 911 WHITEWING LN Property ID 005401-0101-0060 R $# R13907 Application type description TEMP POLE Subdivision Name . . . . . . DOVE CROSSING Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ D R HORTON HOMES 12554 RIATTA VISTA CIRCLE SECOND FLOOR AUSTIN TX 78727 (512) 748-4017 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc GS Permit Fee . . . . 20.00 Issue Date . . . . 3/22/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 BUILDING DEPT REPRESENTATIVE: �7 APPLICANT: my-18.,?004 02:21 from: w CM OF COLLBCG S'i-A oN P"ihd c' Dnylgmew Servim ADDRESS/LOCATION- APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764.3496 FAX WWW.CSTX.GOV ��// 01&z5'011k6# To:512 21e 4299 P.3/4 " For omce �U- oiay DATA: I d �L1� 17FF REG )� APPUCATION �# l 9 -1 12) TEMP POLE LOT ---J� "`OCK SUBDIVISION O �J SEC/PH_�� BUSINESS/OWNER NAME'—,Im UOn PHONE:, - 533 -lK 0_�- CONTRACTOR/HOMEOWNER: rlR_i_L�1'M _n PHONE: 51a - 53 3 - l iv�7 CONTRACTOR ADDRESS: I�.S, y XFti /-'� Uf1/-.� 7x ?8 -�a7 ELECTRICIAN: rfddCus PLUMBER �QSS �(�/m�i1•q f �o/�V�� 731- HVAC: - GOOD CENTS (Rosldentlalonly): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION = SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION' SWIMMING POOL Required) n 1 t DESCRIPTION OF WORK: PI\0� �oV_U4_ STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS PROJECT REGISTRATION# EABPRJ VALUATION: $ V 3. TOTAL_ AREA: z'3 20 HEATED AREA: (Cost of Labor and Materials) D PUBLIC SEWER SEPTIC%TREATMENT SYSTEM SEWER TAP: Lis) SIZE WATER TAP: y 3 ct1 SAE 7 OTHER TAP: TEMP POLE GARAGE TYPE: NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE; -- — - Slims------------ ---------- _ -- - - -- ROOF TYPE' SINGLE a - DOUBLE TRIPLE ATTACHED Efl— DETACHED CARPORT a SIGNATURE OF APPLICANT' z (J - IF proposed work invoives new comn lal construction or facade improvements/renovations to an existing commercial property, building ell aions re required. Officlal Use Only 9 -zz -0(o �./�Ia�n s Examiner Zoning Official ants: YI=S r NO a^ w Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls 3 Insulation R value of ceiling 1 (flat areas) 30 Insulation R value of ceiling 2 (vaulted areas/no attic) 4�t ;k Glazing SHGC Glazing U-Factor 10 R value of ductwork A/C SEER Rating