Loading...
HomeMy WebLinkAboutRES2006-00804, 06-805Oce l0(1 - -- - - - --— --- Oh Cos PREPARED 8/16/06, 11:58:55 INSPECTION TICKET PAGE 8 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/16/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 4003 SOUTHERN TRACE CT SUBDIV: SOUTHERN TRACE CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER . . PHONE PARCEL . . 005401-0001-0020 APPL NUMBER: 06-00000804 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/03/06 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 4/03/06 AP April 3, 2006 12:15:52 PM kwolfe Strings On Setbacks O.K. Slab Ground Installed B115 01 6/01/06 RH BLDG, FRAMING TIME: 17:00 6/01/06 DP June 1, 2006 8:26:09 AM kwolfe 06/01/2006 03:34 PM RH PDA Need temp. glass in stairway. Need 4x8 osb upstairs. Need fireblocking downstairs. Tape seal all exterior joints. B115 66/02/06 OC BLDG, FRAMING TIME: 17:00 6/02/06 AP June 2, 2006 10:56:02 AM kwolfe B130 01 6/05/06 RH BLDG, INSULATION TIME: 17:00 6/05/06 DP June 5, 2006 9:41:19 AM bkorthauer 06/05/2006 03:33 PM RH PDA Need to fill all gaps and cracks in exterior walls and above windows. Do not stuff insulation. B130 02 6/06/06 OC BLDG, INSULATION TIME: 17:00 6/07/06 AP June 5, 2006 3:42:43 PM kwolfe B145 01 6/08/06 RH BLDG, EXT. SHEATHING FASTENER TIME: 17:00 6/08/06 AP June 8, 2006 11:00:56 AM malford B125 01 A1116106 BLDG, FINAL TIME: 17:00 f(0(o(o OQ August 16, 2006 11:04:04 AM kwolfe ----------------------------------- CONTINUED ONTO NEXT PAGE----------------v----�----------------- i� ��� 2 Date: 8/16/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 804 Address: 4003 SOUTHERN TRACE CT Type Inspection Type Code Description status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B115 BLDG, FRAMING IC 06/01/2006 03:34 PM RH PDA B115 BLDG, FRAMING IC Need temp. glass in stairway. Need 4x8 osb upstairs. Need B115 BLDG, FRAMING IC fireblocking downstairs. Tape seal all exterior joints. B130 BLDG, INSULATION IC 06/05/2006 03:33 PM RH PDA B130 BLDG, INSULATION IC Need to fill all gaps and cracks in exterior walls and B130 BLDG, INSULATION IC above windows. Do not stuff insulation. Page 1 WF0754576 / 001 City of College Station PAGE 1 REQ. DATE: 03/22/06 -.-- 03/22/06 9:30:59 LOCATION: 4003 SOUTHERN TRACE CT LOC ID: 203138 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT 4" SEWER TAP AND 3/4" WATER TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/22/06 SCHED COMPLETION: 03/22/06 ******************************************************************************** JOB ORDER RESULT COM EBTrS WF0756491 / 001 City of College Station PAGE 1 REQ. DATE: 03/30/06 03/30/06 10:49:55 LOCATION: 4003 SOUTHERN TRACE CT LOC ID: 203138 REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER:` KWOLFE WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/30/06 SCHED COMPLETION: 03/30/06 ******************************************************************************** JOB ORDER RESULT COMIENTS 1 CITY OF COLLEGE STATION Planning & Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLAN REVIEW/PERMIT NUMBER# �� _ goc� DATE: 3 BUILDING ADDRESS: yoa3 '"Ac•��co CA. I. Foundation Requirements N K A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. i PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning 6 Development Services II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. N 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes III. Stairway Requirements A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6'-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) NiMOK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning c4 Development Services V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N AtW A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NAQkj A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units) T B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements NA/ A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements NA/ Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NAI Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required 4 CITY OF COLLEGE STATION Planning & Development Services Comments: PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS —Z� 6 A6,L- LANS EXAMINER DATE REScheck Software Version 3.7 Release 1 b Compliance Certificate Project Title: Plan # 1557C Report Date: 03/17/06 Energy Code: 2000 IECC Location: College Station, Texas Construction Type: Single Family Glazing Area Percentage: 11% Heating Degree Days: 1788 Construction Site: Owner/Agent: Permit Date: 02-02-2006 Maximum SHGC: 0.40 Your SHGC: 0.40 Designer/Contractor: Permit # Permit Date Ceiling 1: Flat Ceiling or Scissor Truss: 825 30.0 0.0 29 Wall 1: Wood Frame, 16" o.c.: 2085 13.0 0.0 150 Window 1: Metal Frame, Double Pane with Low-E: 201 0.670 135 SHGC: 0.40 Door 1: Solid: 18 0.500 9 Door 2: Solid: 18 0.500 9 Door 3: Glass: 18 0.440 8 SHGC: 0.40 Floor 1: Slab-On-Grade:Unheated: , Insulation Depth: 0.0' 124 0.0 129 Air Conditioner 2: Electric Central Air: 12 SEER Furnace 2: Forced Hot Air: 80 AFUE Compliance Statement: Statement of Compliance: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 3.7 Release 1 b and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer Project Notes: Previously saved project information: Green 4003 Southern Trace Drive College Station, Texas Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 Company Name t 3 7-06 Date Plan # 1557C Page 1 of 4 Y 1{ CREScheck Software Version 3.7 Release 1 b �(j Inspection- Checklist Date: 03/17/06 Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: ❑ Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1: Solid, U-factor: 0.500 Comments: ❑ Door 2: Solid, U-factor: 0.500 Comments: ❑ Door 3: Glass, U-factor: 0.440 Comments: Floors: ❑ Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: ❑ Air Conditioner 2: Electric Central Air: 12 SEER or higher Make and Model Number: ❑ Furnace 2: Forced Hot Air: 80 AFUE or higher Make and Model Number: Solar Heat Gain Coefficient: ❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Plan # 1557C Page 2 of 4 Duct Insulation: ❑ Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: Q. All -joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181 A or UL 181 B. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. Plan # 1557C Page 3 of 4 Y Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non -Circulating Runouts Circulating Mains and Runouts Heated Water Temperature (°F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Piping System Types Fluid Temp. Range(°F) Heating Systems Low Pressure/Temperature 201-250 Low Temperature 120-200 Steam Condensate (for feed water) Any Cooling Systems Chilled Water, Refrigerant and 40-55 Brine Below 40 NOTES TO FIELD: (Building Department Use Only) Insulation Thickness in Inches by Pipe Sizes 2" Runouts 1" and Less 1.25" to 2.0" 2.5 to 4" 1.0 1.5 1.5 2.0 0.5 1.0 1.0 1.5 1.0 1.0 1.5 2.0 0.5 0.5 0.75 1.0 1.0 1.0 1.5 1.5 Plan # 1557C Page 4 of 4 Area Calculator: Description Window Area Total: 201.00 03/17/06 11:08:27 1 /1 Area Calculator: IMM I- Comments/ Door Area Total: 53.34 03/17/06 11:08:28 1 /1 Area Calculator: Assembly Type Comments/Description Ceiling Area Total: 825.00 03/17/06 11:08:28 1 /1 Area Calculator: Assembly Type Comments/Description 'gym �■�■�� Exterior Wall Area Total: 2085.33 03/17/06 11:08:28 1/1 Area Calculator: Assembly Type Unheated Slab -On -Grade Floor Area Total: 0.00 03/17/06 11:08:29 1 /1 BUILDING PERMIT CITY OF COLLEGE STATION 110,1 TEXAS AVE COLLEGE h" TrbN, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 - -------------------------------------------------------------------------- Application Number . . . . . 06-00000804 Date 3/22/06 Property Address . . . . . . 4003 SOUTHERN TRACE CT Property ID: 005401-0001-0020 R #: R13844 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SOUTHERN TRACE Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 102762 Owner Contractor ------------------------ ------------------------ STYLECRAFT BUILDERS 4090 SH 6 S COLLEGE STATION TX 77845 (979) 690-1222 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE SIDING IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) NA HEATED AREA 1557.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc BK Permit Fee . . . . 469.00 Plan Check Fee .00 Issue Date . . . . 3/22/06 Valuation . . . . 102762 Expiration Date . . 9/18/06 Qty Unit Charge Per Extension BASE FEE 460.00 3.00 3.0000 THOU BLDG, VAL 100001-500000 9.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIP ENT AND WALKWAY --- ----- ---------------- --------' - ------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 06-00000804 Date 3/22/06 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL -BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BUILDING DEPT REPRESENTATIVE: APPLICANT BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 06-00000804 Date 3/22/06 ---------------------------------------------------------------------------- Special Notes and Comments BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Shared drive agreement to be filed prior t C/O BUILDING DEPT REPRESENTATIVE: APPLICANT BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00000804 Date 3/22/06 ---------------------------------------------------------------------------- Special Notes and Comments Prescriptive bracing OSB and Let In Bracing. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited -------------------- Due ---------- ----------------- Permit Fee Total ---------- 469.00 469.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1219.00 1219.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496' ---------------------------------------------------------------------------- Application Number . . . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner ------------------------ 06-00000805 Date 3/22/06 4003 SOUTHERN TRACE CT 005401-0001-0020 R13844 TEMP POLE SOUTHERN TRACE RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Contractor ------------------------ OWNER ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc BKL Permit Fee 20.00 Issue Date 3/22/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid ---------- Credited -------------------- Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------------------,= -- -------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planning& DevelopmentSeniat www.CSTX.GOV � Office Um Only DATE: 4RCC REG APPLICATION # OU- — 0W TEMP POLE # 0 U ADDRESS/LOCATION: Lf 0 d 3 LOT �_ /BLOCK SUBDIVISION 15: ,_-1n., Te4er ' SEC/PH r BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Sinale Familv Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: " TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ NIA VALUATION: $ C W-, ? 6 7- / ,TOTAL AREA: 160 9 HEATED AREA: (Cost of Labor and Materials) j I] Y FX PUBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM QX SEWER TAP: 4" SIZE �X WATER TAP: 3/a" SIZE OTHER TAP: SIZE b TEMP POLE GARAGE TYPE: SINGLE F1 ATTACHED I •1 NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: 3 Sheet Rock Siding and/or Masonry Slab on Grade Composition DOUBLE [::] TRIPLE E] DETACHED F__] CARPORT a SIGNATURE OF APPLICANT: - For St lecraft *If proposed work involves new commercial constru Ion or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only Plans Examiner -5--vL, 0,5 / Zoning Official pAA.'r C'I" +4X C ents. rNO i`- Energy Code Compliance Information / % Glazing of exterior walls % Insulation R value of exterior walls R13 / Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40/ Glazing U-Factor .65 / R value of ductwork R6 / A/C SEER Rating 13