PREPARED 8/16/06, 11:58:55 INSPECTION TICKET PAGE 8
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/16/06
------------------------------------------------------------------------------------------------
ADDRESS . : 4003 SOUTHERN TRACE CT SUBDIV: SOUTHERN TRACE
CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER . . PHONE
PARCEL . . 005401-0001-0020
APPL NUMBER: 06-00000804 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/03/06 JGM BLDG, FOUNDATION -SLAB TIME: 17:00
4/03/06 AP April 3, 2006 12:15:52 PM kwolfe
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 6/01/06 RH BLDG, FRAMING TIME: 17:00
6/01/06 DP June 1, 2006 8:26:09 AM kwolfe
06/01/2006 03:34 PM RH PDA
Need temp. glass in stairway. Need 4x8 osb upstairs. Need
fireblocking downstairs. Tape seal all exterior joints.
B115 66/02/06 OC BLDG, FRAMING TIME: 17:00
6/02/06 AP June 2, 2006 10:56:02 AM kwolfe
B130 01 6/05/06 RH BLDG, INSULATION TIME: 17:00
6/05/06 DP June 5, 2006 9:41:19 AM bkorthauer
06/05/2006 03:33 PM RH PDA
Need to fill all gaps and cracks in exterior walls and
above windows. Do not stuff insulation.
B130 02 6/06/06 OC BLDG, INSULATION TIME: 17:00
6/07/06 AP June 5, 2006 3:42:43 PM kwolfe
B145 01 6/08/06 RH BLDG, EXT. SHEATHING FASTENER TIME: 17:00
6/08/06 AP June 8, 2006 11:00:56 AM malford
B125 01 A1116106 BLDG, FINAL TIME: 17:00
f(0(o(o OQ August 16, 2006 11:04:04 AM kwolfe
----------------------------------- CONTINUED ONTO NEXT PAGE----------------v----�-----------------
i� ��� 2
Date: 8/16/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 804
Address: 4003 SOUTHERN TRACE CT
Type
Inspection Type Code
Description
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
06/01/2006 03:34 PM RH PDA
B115
BLDG, FRAMING
IC
Need temp. glass in stairway. Need 4x8 osb upstairs. Need
B115
BLDG, FRAMING
IC
fireblocking downstairs. Tape seal all exterior joints.
B130
BLDG, INSULATION
IC
06/05/2006 03:33 PM RH PDA
B130
BLDG, INSULATION
IC
Need to fill all gaps and cracks in exterior walls and
B130
BLDG, INSULATION
IC
above windows. Do not stuff insulation.
Page 1
WF0754576 / 001 City of College Station PAGE 1
REQ. DATE: 03/22/06 -.-- 03/22/06 9:30:59
LOCATION: 4003 SOUTHERN TRACE CT LOC ID: 203138
REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT
4" SEWER TAP AND 3/4" WATER TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/22/06 SCHED COMPLETION: 03/22/06
********************************************************************************
JOB ORDER RESULT COM EBTrS
WF0756491 / 001 City of College Station PAGE 1
REQ. DATE: 03/30/06 03/30/06 10:49:55
LOCATION: 4003 SOUTHERN TRACE CT LOC ID: 203138
REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN
REQ. USER: KWOLFE AUTH. USER:` KWOLFE WORK TYPE: ROUT
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/30/06 SCHED COMPLETION: 03/30/06
********************************************************************************
JOB ORDER RESULT COMIENTS
1
CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER# �� _ goc� DATE: 3
BUILDING ADDRESS: yoa3 '"Ac•��co CA.
I. Foundation Requirements
N K
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
i
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning 6 Development Services
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
N
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6'-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
NiMOK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning c4 Development Services
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
N AtW
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NAQkj
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units)
T
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
NA/
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
NA/
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
NAI
Approved subdivision
Plat filed
Floodplain Regulations — Ordinance 1301
OK
Does not block any water course or divert any flow
Elevation certificate if required
4
CITY OF COLLEGE STATION
Planning & Development Services
Comments:
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
—Z� 6
A6,L-
LANS EXAMINER DATE
REScheck Software Version 3.7 Release 1 b
Compliance Certificate
Project Title: Plan # 1557C
Report Date: 03/17/06
Energy Code: 2000 IECC
Location: College Station, Texas
Construction Type: Single Family
Glazing Area Percentage: 11%
Heating Degree Days: 1788
Construction Site: Owner/Agent:
Permit Date: 02-02-2006
Maximum SHGC: 0.40 Your SHGC: 0.40
Designer/Contractor:
Permit #
Permit Date
Ceiling 1: Flat Ceiling or Scissor Truss:
825 30.0
0.0
29
Wall 1: Wood Frame, 16" o.c.:
2085 13.0
0.0
150
Window 1: Metal Frame, Double Pane with Low-E:
201
0.670
135
SHGC: 0.40
Door 1: Solid:
18
0.500
9
Door 2: Solid:
18
0.500
9
Door 3: Glass:
18
0.440
8
SHGC: 0.40
Floor 1: Slab-On-Grade:Unheated: , Insulation Depth: 0.0'
124
0.0
129
Air Conditioner 2: Electric Central Air: 12 SEER
Furnace 2: Forced Hot Air: 80 AFUE
Compliance Statement: Statement of Compliance: The proposed building design described here is consistent with the building
plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet
the 2000 IECC requirements in REScheck Version 3.7 Release 1 b and to comply with the mandatory requirements listed in the
REScheck Inspection Checklist.
Builder/Designer
Project Notes:
Previously saved project information:
Green
4003 Southern Trace Drive
College Station, Texas
Stylecraft Builders, Inc.
4090 St. Hwy. 6 S.
College Station, Texas 77845
Company Name
t 3 7-06
Date
Plan # 1557C
Page 1 of 4
Y 1{
CREScheck Software Version 3.7 Release 1 b
�(j Inspection- Checklist
Date: 03/17/06
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
❑ Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.670
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1: Solid, U-factor: 0.500
Comments:
❑ Door 2: Solid, U-factor: 0.500
Comments:
❑ Door 3: Glass, U-factor: 0.440
Comments:
Floors:
❑ Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
❑ Air Conditioner 2: Electric Central Air: 12 SEER or higher
Make and Model Number:
❑ Furnace 2: Forced Hot Air: 80 AFUE or higher
Make and Model Number:
Solar Heat Gain Coefficient:
❑ The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be
determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed.
❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation.
Materials Identification:
❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment must be identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided.
❑ Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or
specifications.
Plan # 1557C Page 2 of 4
Duct Insulation:
❑ Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0.
Duct Construction:
Q. All -joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181 A or UL 181 B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500
Pa).
❑ The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the
heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral
heat trap or is part of a circulating system.
❑ Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
❑ Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from
non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table
2.
Plan # 1557C Page 3 of 4
Y
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non -Circulating Runouts
Circulating Mains and
Runouts
Heated Water
Temperature (°F)
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-169
0.5
0.5
1.0
1.5
100-139
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Piping System Types
Fluid Temp.
Range(°F)
Heating Systems
Low Pressure/Temperature
201-250
Low Temperature
120-200
Steam Condensate (for feed water)
Any
Cooling Systems
Chilled Water, Refrigerant and
40-55
Brine
Below 40
NOTES TO FIELD: (Building Department Use Only)
Insulation Thickness in Inches by Pipe Sizes
2" Runouts 1" and Less 1.25" to 2.0" 2.5 to 4"
1.0
1.5
1.5
2.0
0.5
1.0
1.0
1.5
1.0
1.0
1.5
2.0
0.5
0.5
0.75
1.0
1.0
1.0
1.5
1.5
Plan # 1557C
Page 4 of 4
Area Calculator:
Description
Window Area Total: 201.00
03/17/06 11:08:27 1 /1
Area Calculator:
IMM
I-
Comments/
Door Area Total: 53.34
03/17/06 11:08:28 1 /1
Area Calculator:
Assembly Type
Comments/Description
Ceiling Area Total: 825.00
03/17/06 11:08:28 1 /1
Area Calculator:
Assembly Type
Comments/Description
'gym
�■�■��
Exterior Wall Area Total: 2085.33
03/17/06 11:08:28 1/1
Area Calculator:
Assembly Type
Unheated Slab -On -Grade
Floor Area Total: 0.00
03/17/06 11:08:29 1 /1
BUILDING PERMIT
CITY OF COLLEGE STATION
110,1 TEXAS AVE
COLLEGE h" TrbN, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
- --------------------------------------------------------------------------
Application Number .
. . . . 06-00000804 Date 3/22/06
Property Address . .
. . . . 4003 SOUTHERN TRACE CT
Property ID:
005401-0001-0020
R #:
R13844
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . SOUTHERN TRACE
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 102762
Owner
Contractor
------------------------
------------------------
STYLECRAFT BUILDERS
4090 SH 6 S
COLLEGE STATION TX 77845
(979) 690-1222
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE SIDING
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
TYPE OF GARAGE (ATT/DET) NA
HEATED AREA 1557.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 405.00
----------------------------------------------------------------------------
Permit
BUILDING PERMIT
Additional desc
BK
Permit Fee . . . .
469.00 Plan Check Fee .00
Issue Date . . . .
3/22/06 Valuation . . . . 102762
Expiration Date . .
9/18/06
Qty Unit Charge Per Extension
BASE FEE 460.00
3.00 3.0000 THOU BLDG, VAL 100001-500000 9.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIP ENT AND WALKWAY
--- ----- ---------------- --------' - -------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 06-00000804 Date 3/22/06
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL -BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BUILDING DEPT REPRESENTATIVE:
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 06-00000804 Date 3/22/06
----------------------------------------------------------------------------
Special Notes and Comments
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Shared drive agreement to be filed prior t C/O
BUILDING DEPT REPRESENTATIVE:
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number
. . . . .
06-00000804
Date 3/22/06
----------------------------------------------------------------------------
Special Notes and
Comments
Prescriptive bracing
OSB and
Let In Bracing.
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
--------------------
Due
----------
-----------------
Permit Fee Total
----------
469.00
469.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1219.00
1219.00
.00
.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496'
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
Owner
------------------------
06-00000805 Date 3/22/06
4003 SOUTHERN TRACE CT
005401-0001-0020
R13844
TEMP POLE
SOUTHERN TRACE
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Contractor
------------------------
OWNER
----------------------------------------------------------------------------
Permit
TEMP POLE
PERMIT
Additional desc
BKL
Permit Fee
20.00
Issue Date
3/22/06
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT
POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid
----------
Credited
--------------------
Due
-----------------
Permit Fee Total
20.00
20.00
.00
.00
Other Fee Total
45.00
45.00
.00
.00
Grand Total
65.00
65.00
.00
.00
------------------------------,= -- --------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning& DevelopmentSeniat www.CSTX.GOV
� Office Um Only
DATE: 4RCC REG
APPLICATION # OU- — 0W
TEMP POLE # 0 U
ADDRESS/LOCATION: Lf 0 d 3 LOT �_ /BLOCK SUBDIVISION 15: ,_-1n., Te4er ' SEC/PH r
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 120
CONTRACTOR ADDRESS: 4090 State Highway 6 South
ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing
HVAC: Control Temp GOOD CENTS (Residential only): No
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: Conventional Framing
STRUCTURE USE: Sinale Familv Residence
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: "
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ NIA
VALUATION: $ C W-, ? 6 7- / ,TOTAL AREA: 160 9 HEATED AREA:
(Cost of Labor and Materials)
j
I] Y
FX PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
QX SEWER TAP:
4"
SIZE
�X WATER TAP:
3/a"
SIZE
OTHER TAP:
SIZE
b TEMP POLE
GARAGE TYPE:
SINGLE F1
ATTACHED I •1
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
3
Sheet Rock
Siding and/or Masonry
Slab on Grade
Composition
DOUBLE [::] TRIPLE E]
DETACHED F__] CARPORT a
SIGNATURE OF APPLICANT: - For St lecraft
*If proposed work involves new commercial constru Ion or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
Plans Examiner
-5--vL, 0,5
/ Zoning Official
pAA.'r C'I" +4X
C ents.
rNO
i`-
Energy Code Compliance Information
/
% Glazing of exterior walls
%
Insulation R value of exterior walls
R13
/
Insulation R value of ceiling 1 (flat areas)
R30
Insulation R value of ceiling 2 (vaulted areas/no attic)
R19
Glazing SHGC
.40/
Glazing U-Factor
.65
/
R value of ductwork
R6
/
A/C SEER Rating
13