Loading...
HomeMy WebLinkAboutRES2006-008010 W--1�ol *PWNkffevir *on& R752113 10% 19M TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 06-00000689 4121 HALIFAX DR 569500-1439-0260 TEMP POLE Date 3/08/06 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDERS ED FROEHLING 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc KW Permit Fee 20.00 Issue Date . . . . 3/08/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . Contractor . . . . . . Application number Description of Work Construction type . . . Occupancy type . . . . Flood Zone . . . . . . 7/17/06 569500-1439-0260 4121 HALIFAX DR COLLEGE STATION TX 77845 SHENANDOAH PH 14 SHENANDOAH 414, BLOCK 39, LOT 26 SINGLE FAMILY RESIDENTIAL ED FROEHLING BUILDER INC ED FROEHLING BUILDERS 979 776-8266 06-00000801 000 000 RESIDENTIAL, 1 UNIT DETACHED NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX 0 Approved . . . . . . . ':-'7:"�-BuiJjinj Official VOID UNLESS SIGNED BY BUILDING OFFICIAL h PREPARED 7/17/06, 11:59:26 INSPECTION TICKET PAGE 12 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/17/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 4121 HALIFAX DR SUBDIV: SHENANDOAH PH 14 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER . . PHONE PARCEL . . 569500-1439-0260 APPL NUMBER: 06-00000801 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/17/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00 4/17/06 AP April 17, 2006 11:07:52 AM bkorthauer Strings On Setbacks O.K. Slab Ground Installed B115 01 5/23/06 OC BLDG, FRAMING TIME: 17:00 5/23/06 AP May 22, 2006 3:40:39 PM glsouth B130 01 5/26/06 OC BLDG, INSULATION TIME: 17:00 5/26/06 AP May 25, 2006 12:24:09 PM kwolfe May 26, 2006 12:09:06 PM kwolfe B125 01 7/ 7/06 �B/ BLDG, FINAL TIME: 17:00 July 17, 2006 10:17:54 AM glsouth -------------------------------------- COMMENTS AND NOTES-------------------------------------- '4 IV t'� Tfrl*' 21 4'3-1 , I L WF0774426 / 001 City of College Station PAGE 1 REQ. DATE: 05/16/06 05/16/06 15:32:34 LOCATION: 4121 HALIFAX DR LOC ID: 202654 REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT 4" SWR TAP 3/4" WTR TAP TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 05/16/06 SCHED COMPLETION: 05/16/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0754597 / 001 City of College Station PAGE 1 REQ. DATE: 03/22/06 03/22/06 10:09:36 LOCATION: 4121 HALIFAX DR LOC ID: 202654 REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/22/06 SCHED COMPLETION: 03/22/06 ******************************************************************************** JOB ORDER RESULT CONIlVMNTS BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 7 ,-8-40 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000801 Date 3/22/06 Property Address . . . . . . 4121 HALIFAX DR Property ID . . . . . . . . . 569500-1439-0260 R# . . . . . . . . . . . . . Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 138930 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDERS ED FROEHLING 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2105.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE SWR TAZ 427.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit Fee . . . . 577.00 Plan Check Fee .00 Issue Date . . . . 3/22/06 Valuation . . . . 138930 Expiration Date . . 9/18/06 Qty Unit Charge Per Extension BASE FEE 460.00 39.00 3.0000 THOU BLDG, VAL 100001-500000 117.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) - -- -------------------------- BUILDING DEPT REPRESENTATIVE: _11 APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000801 Page 2 Date 3/22/06 Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 301-) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77.840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000801 Page 3 Date 3/22/06 Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED c BUILDING DEPT REPRESENTATIVE: n n / APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 7-3840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00000801 Date 3/22/06 ---------------------------------------------------------------------------- Special Notes and Comments SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES Narrow wall bracing Fully Sheathed with APA framing in garage and dining areas. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited -------------------- ---------- Due --------------------------- Permit Fee Total 577.00 577.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1327.00 1327.00 .00 .00 ------------------------------ - --- — ------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: For Office Use APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 �.. (979) 764-3570 (979) 764-3496 FAX CITY OF COLLEGE STA`nON,, 1NWW.CSTX.GOV Planning dDevelgmintServicei- ' 11 ADDRESS/LOC TIONe : � -4I46,ulpgs�< LOT � LOCK %- UBDIVISION BUSINESS/OWNER NAME. CONTRACTOR/HOMEOWNER: l� 4. CONTRACTOR ADDRESS:` f " PATE J ' 1 l �(A C REG APPLICATION # TEMP POLE # PHONE: SEC/PH IA - ELECTRICIAN: ` PLUMBER: —Danz � fWkwM. HVAC: 0 IIC25 GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION ,., OVING SHELL ONLY DEMOLITION (Asbestos' Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: PROPOSED USE: N►Jf'i .6 U wy HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PRO CT REGISTRATION# EABPRJ VALUATION: $ L56"950.00 TOTAL AREA: 259-4- HEATED AREA: 2405 (Cost of Labor and Materials) D PUBLIC SEWER NUMBER OF BEDROOMS: ❑ SEPTIC/TREATMENT SYSTEM M EWER TAP: IZE WATER TAP: 3 SIZE ❑ OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE E] NUMBER OF BATHROOMS: INTERIOR WALL TYPE EXTERIOR WALL TYPE FOUNDATION TYPE ROOF TYPE: DOUBLE TRIPLE ATTACHED DETACHED SIGNATURE OF APPLICANT: V *If proposed work involves new commercial tr-L commercial property, building elevations are requir / Plans Examiner 21P q)v 1( ske4ltl w ,VA y I a CARPORT or racaae Zoning Official ents: YES r NO ovations to an existing Fire Marshall Energy Code Compliance Information t P-r % Glazing of exterior wails Insulation •R value of exterior-'wall"s Insulation.R value of ceiling. 1 (flat areas) lnsiAa6Yri*R value of ceHiug-2-.(vaulted areas/no,atU)'�' .4 Glazin'g4M- , Glazing U-Factor R value of ductwork A/C SEER Rating 7 PLAN REVIEW ONE and TWO FAMILY CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS Planning & Development Services PLAN REVIEW/PERMIT NUMBER# 06 Sol I DATE: 3 Lai lv(. BUILDING ADDRESS: 4f21 I. Foundation Requirements NA/ A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species 7-1 B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. 1 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning & Development Servicer II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. N7 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes III. Stairway Requirements O A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning d Development Services V. Electrical Service Requirements NA/ A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements NAB A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/ A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) VIII. Energy Requirements Na A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 NA/ Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements N Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NN Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required % tilt Wt CITY OF COLLEGE STATION Planning & Development Services Comments: P 4 NS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS - 1i DATE J Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\l 108PB.rck TITLE: 4121 Halifax CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 03/16/06 DATE OF PLANS: July 1, 2004 PROJECT INFORMATION: LOT 26 BLOCK 39 SHENANDOAH PHASE 14 COMPANY INFORMATION: ED FROEHLING BUILDER, INC NOTES: Ledbetter Plan COMPLIANCE: Passes Maximum UA = 729 Your Home UA = 593 18.7% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.37 Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 2105 30.0 0.0 74 Wall 1: Wood Frame, 16" o.c. 396 13.0 0.0 24 Window 1: Metal Frame, Double Pane with Low-E 70 0.640 45 SHGC: 0.40 Bldg. faces 225 deg. from North; Comp. orient.: Front Projection factor: 0.19 Door 1: Solid 38 0.400 15 Wall 2: Wood Frame, 16" o.c. 450 13.0 0.0 36 Window 2: Metal Frame:Double Pane with Low-E 14 0.640 9 SHGC: 0.40 Bldg. faces 225 deg. from North; Comp. orient.: Left Side Projection factor: 0.27 Wall 3: Wood Frame, 16" o.c. 460 13.0 0.0 26 Window 3: Metal Frame:Double Pane with Low-E 120 0.640 77 SHGC: 0.40 Bldg. faces 225 deg. from North; Comp. orient.: Back Projection factor: 0.23 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 225 deg. from North; Comp. orient.: Back Projection factor: 0.57 Wall 4: Wood Frame, 16" o.c. 450 13.0 0.0 34 Window 4: Metal Frame:Double Pane with Low-E 36 0.640 23 SHGC: 0.40 Bldg. faces 225 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Floor 1: Unheated 211 0.0 220 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 13 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 felease lb formerly MECchecl and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer Date -3 ��P Lot 24, Block 39 Lot 25, Block 39 S 44 33' 24" E - 72.5' W Q � o, J E 0 T m �• N W M N ftft cc Ct O '0 Z