HomeMy WebLinkAboutRES2006-008010 W--1�ol
*PWNkffevir
*on&
R752113 10% 19M
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
06-00000689
4121 HALIFAX DR
569500-1439-0260
TEMP POLE
Date 3/08/06
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner
Contractor
------------------------
------------------------
ED FROEHLING BUILDERS
ED FROEHLING
3887 HIGH LONESOME
RD
COLLEGE STATION
TX 77845
(979) 776-8266
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc
KW
Permit Fee
20.00
Issue Date . . .
. 3/08/06
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
Contractor . . . . . .
Application number
Description of Work
Construction type . . .
Occupancy type . . . .
Flood Zone . . . . . .
7/17/06
569500-1439-0260
4121 HALIFAX DR
COLLEGE STATION TX 77845
SHENANDOAH PH 14
SHENANDOAH 414, BLOCK 39, LOT
26
SINGLE FAMILY RESIDENTIAL
ED FROEHLING BUILDER INC
ED FROEHLING BUILDERS
979 776-8266
06-00000801 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
0
Approved . . . . . . .
':-'7:"�-BuiJjinj Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
h
PREPARED 7/17/06, 11:59:26 INSPECTION TICKET PAGE 12
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/17/06
------------------------------------------------------------------------------------------------
ADDRESS . : 4121 HALIFAX DR SUBDIV: SHENANDOAH PH 14
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER . . PHONE
PARCEL . . 569500-1439-0260
APPL NUMBER: 06-00000801 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/17/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00
4/17/06 AP April 17, 2006 11:07:52 AM bkorthauer
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 5/23/06 OC BLDG, FRAMING TIME: 17:00
5/23/06 AP May 22, 2006 3:40:39 PM glsouth
B130 01 5/26/06 OC BLDG, INSULATION TIME: 17:00
5/26/06 AP May 25, 2006 12:24:09 PM kwolfe
May 26, 2006 12:09:06 PM kwolfe
B125 01 7/ 7/06 �B/ BLDG, FINAL TIME: 17:00
July 17, 2006 10:17:54 AM glsouth
-------------------------------------- COMMENTS AND NOTES--------------------------------------
'4 IV t'� Tfrl*'
21 4'3-1 ,
I L
WF0774426 / 001 City of College Station
PAGE 1
REQ. DATE:
05/16/06
05/16/06
15:32:34
LOCATION:
4121 HALIFAX DR
LOC ID:
202654
REQUESTOR:
ED FROEHLING BUILDERS ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER: GLSOUTH
WORK TYPE:
ROUT
4" SWR TAP
3/4" WTR TAP
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
05/16/06 SCHED COMPLETION:
05/16/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0754597 /
001 City of College
Station
PAGE 1
REQ. DATE:
03/22/06
03/22/06
10:09:36
LOCATION:
4121 HALIFAX DR
LOC ID:
202654
REQUESTOR:
ED FROEHLING BUILDERS
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
TEMP POLE
PASSED
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
03/22/06 SCHED
COMPLETION:
03/22/06
********************************************************************************
JOB ORDER RESULT CONIlVMNTS
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 7 ,-8-40
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00000801 Date 3/22/06
Property Address . . . . . . 4121 HALIFAX DR
Property ID . . . . . . . . . 569500-1439-0260
R# . . . . . . . . . . . . .
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 138930
Owner
Contractor
------------------------
------------------------
ED FROEHLING BUILDERS
ED FROEHLING
3887 HIGH LONESOME
RD
COLLEGE STATION
TX 77845
(979) 776-8266
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2105.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
SWR
TAZ
427.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
GS
Permit Fee . . . .
577.00 Plan Check Fee
.00
Issue Date . . . .
3/22/06 Valuation . . .
. 138930
Expiration Date . .
9/18/06
Qty Unit Charge
Per
Extension
BASE FEE
460.00
39.00 3.0000
THOU BLDG, VAL 100001-500000
117.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
- -- --------------------------
BUILDING DEPT REPRESENTATIVE:
_11
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000801
Page 2
Date 3/22/06
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 301-) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77.840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000801
Page 3
Date 3/22/06
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
c
BUILDING DEPT REPRESENTATIVE:
n n /
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 7-3840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . .
06-00000801
Date
3/22/06
----------------------------------------------------------------------------
Special Notes and Comments
SUCH THAT THE IGNITION SOURCE
IS 18" ABOVE
THE FLOOR IN
PRIVATE GARAGES
Narrow wall bracing Fully Sheathed
with APA
framing in
garage and dining areas.
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged
Paid Credited
--------------------
----------
Due
---------------------------
Permit Fee Total 577.00
577.00
.00
.00
Plan Check Total .00
.00
.00
.00
Other Fee Total 750.00
750.00
.00
.00
Grand Total 1327.00
1327.00
.00
.00
------------------------------ - --- — -------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
For Office Use
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
�.. (979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STA`nON,, 1NWW.CSTX.GOV
Planning dDevelgmintServicei- '
11
ADDRESS/LOC TIONe : � -4I46,ulpgs�<
LOT � LOCK %- UBDIVISION
BUSINESS/OWNER NAME.
CONTRACTOR/HOMEOWNER: l�
4.
CONTRACTOR ADDRESS:` f "
PATE J ' 1 l �(A C REG
APPLICATION #
TEMP POLE #
PHONE:
SEC/PH IA -
ELECTRICIAN: ` PLUMBER: —Danz � fWkwM.
HVAC: 0 IIC25 GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION ,., OVING SHELL ONLY
DEMOLITION (Asbestos' Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE: N►Jf'i .6 U wy
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PRO CT REGISTRATION# EABPRJ
VALUATION: $ L56"950.00 TOTAL AREA: 259-4- HEATED AREA: 2405
(Cost of Labor and Materials)
D PUBLIC SEWER NUMBER OF BEDROOMS:
❑ SEPTIC/TREATMENT SYSTEM
M
EWER TAP:
IZE
WATER TAP: 3
SIZE
❑ OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE E]
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE
EXTERIOR WALL TYPE
FOUNDATION TYPE
ROOF TYPE:
DOUBLE TRIPLE
ATTACHED DETACHED
SIGNATURE OF APPLICANT: V
*If proposed work involves new commercial tr-L
commercial property, building elevations are requir
/ Plans Examiner
21P q)v
1( ske4ltl w ,VA
y I
a CARPORT
or racaae
Zoning Official
ents:
YES r NO
ovations to an existing
Fire Marshall
Energy Code Compliance Information
t
P-r
% Glazing of exterior wails
Insulation •R value of exterior-'wall"s
Insulation.R value of ceiling. 1 (flat areas)
lnsiAa6Yri*R value of ceHiug-2-.(vaulted areas/no,atU)'�'
.4
Glazin'g4M-
,
Glazing U-Factor
R value of ductwork
A/C SEER Rating
7
PLAN REVIEW
ONE and TWO FAMILY
CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS
Planning & Development Services
PLAN REVIEW/PERMIT NUMBER# 06 Sol
I DATE: 3 Lai lv(.
BUILDING ADDRESS: 4f21
I. Foundation Requirements
NA/
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
7-1
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
1 PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning & Development Servicer
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
N7
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
O
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning d Development Services
V. Electrical Service Requirements
NA/
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
NAB
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
VIII. Energy Requirements
Na
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
NA/
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
N
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
NN
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
OK
Does not block any water course or divert any flow
Elevation certificate if required
%
tilt
Wt
CITY OF COLLEGE STATION
Planning & Development Services
Comments:
P 4 NS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
- 1i
DATE
J
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\l 108PB.rck
TITLE: 4121 Halifax
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 03/16/06
DATE OF PLANS: July 1, 2004
PROJECT INFORMATION:
LOT 26 BLOCK 39
SHENANDOAH PHASE 14
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
NOTES:
Ledbetter Plan
COMPLIANCE: Passes
Maximum UA = 729
Your Home UA = 593
18.7% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.37
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
2105
30.0
0.0
74
Wall 1: Wood Frame, 16" o.c.
396
13.0
0.0
24
Window 1: Metal Frame, Double Pane with Low-E
70
0.640
45
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Front
Projection factor: 0.19
Door 1: Solid
38
0.400
15
Wall 2: Wood Frame, 16" o.c.
450
13.0
0.0
36
Window 2: Metal Frame:Double Pane with Low-E
14
0.640
9
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Left Side
Projection factor: 0.27
Wall 3: Wood Frame, 16" o.c.
460
13.0
0.0
26
Window 3: Metal Frame:Double Pane with Low-E
120
0.640
77
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Back
Projection factor: 0.23
Door 2: Glass
18
0.580 10
SHGC: 0.78
Bldg. faces 225 deg. from North; Comp. orient.: Back
Projection factor: 0.57
Wall 4: Wood Frame, 16" o.c.
450 13.0 0.0
34
Window 4: Metal Frame:Double Pane with Low-E
36
0.640 23
SHGC: 0.40
Bldg. faces 225 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Floor 1: Unheated
211 0.0
220
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 felease lb formerly MECchecl and to comply with the mandatory requirements listed in
the RES checkInspection Checklist.
Builder/Designer Date -3 ��P
Lot 24, Block 39
Lot 25, Block 39
S 44 33' 24" E - 72.5'
W
Q
�
o,
J
E
0
T
m
�•
N
W
M
N
ftft
cc
Ct
O
'0
Z