HomeMy WebLinkAboutADDN2006-01021`� Af� •1ee71— --�� f'i521 /3 10% ON PREPARED 11/08/06, 8:03:02 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/07/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 1029 WALTON DR SUBDIV: COLLEGE HILLS CONTRACTOR G-P CONSTRUCTION PHONE (979) 846-2688 OWNER MACHANN, CLINTON J & GINNY PHONE PARCEL 194000-0080-0100 APPL NUMBER: 06-00001021 RESIDENTIAL, ADDITION k PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 O1 4/06/06 TB BLDG, FOUNDATION -SLAB TIME: 17:00 4/06/06 AP April 6, 2006 9:25:01 AM glsouth April 6, 2006 3:44:40 PM glsouth SLAB GROUND FRONT LEFT. B115 0� 6/20/06 RH BLDG, FRAMING TIME: 17:00 6/20/06 AE June 20, 2006 11:58:24 AM kwolfe does not need mechanical 06/20/2006 02:14 PM RH PDA Remove blocks from handrail and add brackets to make handrail continous without removing hand. B130 01 6/27/06 DS BLD , INSULATION TIME: 17:00 6/27/06 AP e 26, 2006 1:31:55 PM kwolfe 11125 01 j17/06gG, FINAL TIME: 17:00 ✓ tuber 7, 2006 2:22:15 PM kwolfe ---------- �1------------------ CONTINUED ONTO NEXT PAGE----------------------------------- fop-+i`b,j 6e ir!5 d e-/Pj WINDOW SCHEDULE ROUGH ;,HGT E OPENING MARK STYLE HEADER HEAD HT. WIDTH I HEIGHT I DESCRIPTION a a rs� h- EX BREEZEWAY TO HOUSE EX HOUSE FIRST FLOOR DOOR AND FRAME SCHEDULE SIZE I I FRAMING NUMI WD JHGT I SWING HEADER IWIDTH.1HEIGHT DESCRIPTION W b: i �i —E)C WINDOW TO BE REMOVED i c c SECOND FLOOR L �: Ifs. -,•-0- EX HOUSE AREA SUMMARY Area Perimeter FIRST FLOOR 1524.242 SF 92-1, wr SECOND FLOOR 1504.6ag SF W-0' FPS 1ISHING NOTES 2. 3. 4. 5. LL = owl z L �0 Nun M CIS CV G i v^, O Z CC Q C i C= �� (o oNAfo cuu) ELECTRICAL LEGEND 0 110 VOLT OUTLET # LIGHT FIXTURE {� 220 VOLT OUTLET Y WALL -HUNG LIGHT GFl LET COACH LIGHT OBallow 0 DISPOSAL / DISHWASHER OUTLET � RECESSED LIGHT f WATER -PROOF OUTLET ®� VENT VENTHOOD OUTLETA VENT -LIGHT CEILING MTO. OUTLET 170\-> FLOOD LIGHT $ ELECTRIC SWITCH ((( CEILING FAN S3 3-WAY SWITCH S3O 3-WAY DIMMER SWITCH FLORESCENT LIGHTSET. D -B. DOORBELL ® DOORBELL CHIME TELEPHONE JACK OS.D. SMOKE DETECTOR WALL MOUNTED TELEPHONE JACK HVAC A/C PAD TELEPHONE JACK ® CABLE TV JACK GAS LINE 'RG-6' CABLE TV JACK ® SPEAKER WIRE 'ELECTRICUW TO ABIDE BY ALL FEDERAL. STATE, AND LOCAL CODES 'PRE -WIRE FOR GARAGE DOOR OPENER < 6 FJ5 co w0 U o O c c• 1•., u M (� Q r0 C1 ✓`� . w 31 z 0 I x� � N t` a 11, c io x x o ELECTRICAL PLAN ( FIRST FLOOR) ELECTRICAL PLAN ( SECOND FLOOR) LSCALE. i .,•m L _ FLOOR FRAMING PLAN SCALE: IJ4'- V-0* .THIS LAYOUT IS MEANT FOR A ROUGH ESTIMATE ONLYI ALL BUILDING CODES SHOULD APPLY. FRAMER CONSULT BUILDER FOR ADDITIONAL INFORMATION. RS (TYP) OIST SYSTEM I & WRAPPED AROUND G 3-2x8s Qj� � ��e rwo� S1�c 0, 1 A 0 r AA'o �evj o I j o4 e, 5, EXISTING 3-2xB_ JOISTS o EMSTING JOIST PLAN SGALF: ifir - 11V EX BREEZEWAY' TO HOUSE EX WALKWAY TO HOUSE LL < C z 00 -T r- ob V" aaL43 rr, V-) lz 0 z C L) Y.1. < 1O 6 MIL POLYETH. VAPOR BARRIER O.C.E.W.- #3 STIRRUPS- ® 36. O.C. --- — - 74" 7,1. 2 - SEEP l8e_ OR AS 2-Ws TSB REQUIRED BY LOCAL CODE 1 2 INTERIOR BE.AX.I DET III 7" 6 MIL. POLYET'Li. -_---_ C-------_ — �__- _-_-= VAPOR BARRIER -___-_� m COMPACTED SELECT FILL P.I. < 15 f #3 STIRRUPS - - - - - @35.O.C. _ ----- o - 74' �- I 2 S D 3SM8t V-2" OR AS Z4e;§ 738. REQUIRED BY LOCAL CODE 3 PORCH BEAINI DETAIL i 6 MIL POLYETH. ` A H VAPOR BARRIER - - - • i s3 STCRI:Il.T>=S --- STIRRUPS �I~ --_ -_-- it - - 3 _.- .---_ I CCPAPJd" -- SELEC,"F " --- ----� P.I.<15 ------- - - o Z-8- =- Wit. -- Zia 1'_2. OR AS� Tw REQUIRED BY LOCAL CODE AEXTERIOR BE AAl DETAIL i 'Y-'S DRIWUQ MMROr DEMCWC-O rf AN ENGINEEWW OR AN 1 ' • ARfk`1R� 9LY6R�1k A UCDYBED R70FE991CNAl Q'(Q'�Eil 1 SHOLL==L+. — TEDREGLLURDWG STRUCTURAL FRAMING . XNRT.?E+'JIi®RT,.3.,SMHOL7„O AN 0I0INEEA7 SEAL BE M`SEM j !lr.,±E7.�7RIR.ToL}IBiTNE'EYGME�OF RECORO' SMALL i ?)=ili,T'E SHOXF.: 3POFISIBLffY FORt T8E 9TRUC. L'RAL CESIGN.I I ?-sLZ SMitL' JQI;"�4E3C PiESPONS180.�CR THE ST1tUCTURAL dmOciHiRfPROBlH1871ATT q✓♦'AveBE RE$IAROING i 1 7):__Evsmmc ' �!FO>IvaaaHMut>c�,;S.Lav�elpLR(gq SL1?BP CA;LEDGEI c�•aADE � Evrw:ocaoe�A+u BEF�uca REAr ANo TTyYr �Aavz� G`IaE7E 51°_Ak.L fikFL.ACEJ WAE21AF3Y o--ER E^C JQ0 4*CrtN N,*m VEEN P4108APAD _XC _ ALL 5TRUCT.AAL CONOFET--.�AALL BE N0AMAL�VaaM T WTrWI A MLNIULIM 29- AY CCMPIWS96E STRENGTH OF3= PSI CONCRE7-E M1%SMALL CCMTATNB SMXS OF CEUEgTP"_ CL'81C 'AR0 SAWALM AND 7 CALLCAS OF WATER PER SAC( OF CEMENT (MNLUUtAt ALL CONCRETE WORK SMALL CCJdFORs- TO ACI 011. CONCRE'TS ALL REINFORCWG BARB SMALL 3E ASTM AS1S GRADE 80 E(CFPTA3 BARS GRADE 411. DETAILING. FABRICATING AND R-ACEMENT SHALL XNFORM TO TFE AC DETAILING MAMIAL 'NO ACL 318. LAP CONTINUOUS BARS AD OIAMETERS AT SPL..'= CONGTE-..PRO-E=ON FOR RENFORCEMFJfT (CC VEM &14.L BE.AS FOLLOW& S TOP FOR SLAB ON GRADE 1/I TOP FOR GRADE BEAMS OAST AGAINST F("S T CAST AGAINST 301 .PROVIDE SUPPORT CLMRS FOR ALL RETWORCING STEy INSTALLu5 • .•d L-SHAPED SARS TOP AND BOTTOM N -XPOSED FACE OF EWER)OR GRADE BEAM CORNERS. M,SCELLVIEOL.IS SHALL BE THE RepONSIOR Y OF THE CONTRAC.,R'^: ;1 EVAMNNE AL=RAWINGS FOR FLOOR ELEVATIONS C.,_¢4. SLOPES DEPRESSFO F_OM AREAS AND EMSEE^J0E7 , 1US, CCAIPAR-.MiCHITECURAL AND 87RUCTLRAL SEC: ,N4AND .'E..POF ALL ZISCREPANCZS TC THE CESIGNER PRIOR :ARR'CA-I KO CR INSTALLNG STRUCTURAL':. .., '. FRIF/ _: VE4SIONS PRIOR TO STARING WORK 4 N AREA SUMMARY Area Perimeter i FIRS ,FLOOR 1524.242 SF 1 97-11 518• SECCC'o FLOOR 15o4.s88 SF i 90-0• F3.FINISHLNG NOTES 2. 4 5 1 ' 0 C i co .` O - o CO r M r;cu r r';C'V CC) � 1 r 0 r R I -FILL IN SIDEWALK TO STAIRS -FILL IN FLOOR AREA -"_SE CRAmNGS CU NT!NC-_L;=P.ALL C-OMPO NENTB 109 _ !`CEDLIREES ':e�SSARY PCR=JSTF;L-CT;CN SAFETY =l'G VS ANE 7^E ?. E=FCNSIBILRT`.' =F T y,^N,RAC'Cv. PUN RATION PT.:N, f( 1 STAI SCALE: 2 o I U �o w o " z o� a 2 BACK ELEVATION 8CALE 7/8 a V-0' ROOF PLAN SCALE: 1/18' - 11-V 2RIGHT ELEVATION SCALE: 1/3• n V-0" ry 1 LEFT ELEVATION SCALE: I/W _ V-cr CUT EXISTING BRICK CO z o 00 00 r C4 cn owe:; �a v ' z 0 H L c N o� U�- a de c st- BUILDING PERMIT CITY OF C&L'--T� K STATION 1101 TEXAS AVE COLLEGE STATION, -TX 77840 PHONE: (979)764-3570 , FAX: (979)764-3496 --------------=------------------------------------------------------------- Application Number . . . . . 06-00001021 Date 4/06/06 Property Address . . . . . . 1029 WALTON DR Property ID: 194000-0080-0100 R #: R23696 Application type description RESIDENTIAL, ADDITION Subdivision Name . . . . . . COLLEGE HILLS Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 54000 Owner Contractor ------------------------ MACHANN, CLINTON J & ------------------------ GINNY G-P CONSTRUCTION BROWN MA TERRY PONZIO 1029 WALTON DR 4444 CARTER CREEK PKWY COLLEGE STATION TX 778402310 BRYAN TX 77802 (979) 846-2688 --- Structure Information 000 000 ADDITION Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB HEATED AREA 524.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 1.00 TAZ 240.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit Fee . . . . 276.00 Plan Check Fee .00 Issue Date . . . . 4/06/06 Valuation . . . . 54000 Expiration Date . . 10/03/06 Qty Unit Charge Per Extension BASE FEE 260.00 4.00 4.0000 THOU BLDG, VAL 50001-100000 16.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET BUILDING DEPT REPRESENTATIVE-: j/" cv'2.'� APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00001021 Page 2 Date 4/06/06 Special Notes and Comments ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Remodeling existing garage apartment. Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 276.00 276.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 276.00 276.00 .00 .00 - - - - �f- - - - - - - - - - - - - - - - - - - - - - - - - BUILDING DEPT REPRESENTATIVE`: APPLICANT:t Z i (*//7APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX CITY OF COLLEGE STATION WWW.CSTX.GOV Planning d' Development Service{. w OH�keQeUse On" DATE ' U`*rRCC : �- REG APPLICATION # UW - 1 b,-)t TEMP POLE # ADDRESS/LOCATION:: AV 7 - Zt,4Qlt% 42, ; LOT to BLOCK o SUBDIVISION 1.0� S �Sf SEC/PH BUSINESS/OWNER NAME: G / ,',vim A�V A/N PHONE: CONTRACTOR/HOMEOWNER: � — Gann ��r ��� PHONE: Z/ o CONTRACTOR ADDRESS ELECTRICIAN: ��` �f PLUMBER: /��� �G� C HVAC: GOOD CENTS (Residential only): CLASS OF WORK C-E-SSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: PROPOSED USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ ,-y-op o` TOTAL AREA: HEATED AREA: !,M (Cos of Labor and Materials) ❑ PUBLIC SEWER SEPTIC/TREATMENT SYSTEM SEWER TAP: SIZE WATER TAP: SIZE OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE El ATTACHED NUMBER OF BEDROOMS: —) NUMBER OF BATHROOMS: INTERIOR WALL TYPE: v EXTERIOR WALL TYPE: ryt C �— FOUNDATION TYPE: ROOF TYPE: / /— DOUBLE F7 TRIPLE a DETACHED -0-- CARPORT F1 SIGNATURE OF APPLICANTS `If proposed work involves new commerclal.const uction or facade improvements/renovations to an existing commercial property, building elevations�are required. �� Official Use Only Plans Examiner Zoning Official IUMV ents: YES r NO Fire Marshall CD *f . i - Energy Code Compliance Information i % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating Ziv PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning & Development Services PLAN REVIEW/PERMIT NUMBER# 06 _ DATE: Iq /06 BUILDING ADDRESS: aj Q . I. Foundation Requirements N A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated A/1 II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning d Development Services II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. K 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" AJ S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes III. Stairway Requirements N A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half (9-1/2) inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) MWK A. Hearth extensions 71 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning 6 Development Services V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements N A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 NAft Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements A/ Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required CITY OF COLLEGE STATION Planning d Development Services Comments: PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS 1 PLANS EXAMINER DATE