HomeMy WebLinkAboutRES2006-01015, 06-1016R Oftmb H7521/3 10%ISP4 PREPARED 8/02/06, 7:54:06 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/02/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 323 ROBELMONT DR SUBDIV: EDELWEISS GARTENS PH 6 CONTRACTOR CHARLES THOMAS HOMES, INC. PHONE (979) 696-4384 OWNER EDELWEISS GARTEN VENTURE PHONE PARCEL 244030-0612-0100 APPL NUMBER: 06-00001015 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/19/06 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 4/19/06 AP April 18, 2006 2:44:14 PM bkorthauer Strings On Setbacks O.K. Slab Ground Installed B115 01 6/06/06 JGM BLDG, FRAMING TIME: 17:00 6/06/06 DP June 6, 2006 8:02:10 AM kwolfe June 6, 2006 11:41:43 AM bkorthauer need to sheet rock pony wall garage side of fire lane chase. B115 02 6/0'7/06 OC BLDG, FRAMING TIME: 17:00 6/07/06 AP June 6, 2006 2:03:00 PM bkorthauer B130 1 6/09/06 BH BLDG, INSULATION TIME: 17:00 6/09/06 AP June 12, 2006 8:16:45 AM kwolfe June 12, 2006 8:17:09 AM kwolfe B12, 01 8 02/06 II BLDG, FINAL TIME: 17:00 a( July 31, 2006 10:37:57 AM kwolfe f -------------------------------------- COMMENTS AND NOTES -------------------------------- { i ^ N (A �P/ Date: 8/3/2006 Inspection Comments for Finals Permit Year: 6 Permit Number: 1015 Address: 323 ROBELMONT DR TYPe Inspection Type Code se t�s Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B115 BLDG, FRAMING IC June 6, 2006 11:41:43 AM bkorthauer B115 BLDG, FRAMING IC need to sheet rock pony wall garage side of fire lane chase. 13130 BLDG, INSULATION IC June 12, 2006 8:17:09 AM kwolfe Page 1 Kim Wolfe Insulation request inspection result, 323 Robelmont, #06 1015 Page 1 From: Brian Henry To: Southerland, Gina Date: 6/9/2006 10:30:28 AM Subject: Insulation request inspection result, 323 Robelmont,—_#06-1015_ Print for file Inspected insulation, 323 Robelmont, #06-1015, Thomas Homes, 6-9-06 Inspection result: Inspected OK for Good Cents Notes: Replace insulation around electrical wiring at breaker panel. CC: Korthauer, Brittany; Wolfe, Kim WF0758036 / 001 City of College Station PAGE 1 REQ. DATE: 04/05/06 04/05/06 16:36:50 LOCATION: 323 ROBELMONT DR LOC ID: 201848 REQUESTOR: CHARLES THOMAS HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT TEMP POLE PASSED TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/05/06 SCHED COMPLETION: 04/05/06 ******************************************************************************** JOB ORDER RESULT COMMENTS Vu. 10 1 G_ WF0757680 / 001 City of College Station PAGE 1 REQ. DATE: 04/04/06 i 04/04/06 15:55:45 LOCATION: 323 ROBELMONT DR LOC ID: 201848 REQUESTOR: CHARLES THOMAS ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT SWR 4" WTR 3/4" TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/04/06 SCHED COMPLETION: 04/04/06 ******************************************************************************** JOB ORDER RESULT CONIl4MTS BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVF►--- COLLEGE S'-ATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00001015, Date 4/04/06 Property Address . . . . . . 323 ROBELMONT DR Property ID . . 244030-0612-0100 R # . . . . . . . . . . . . . R301743 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . EDELWEISS GARTENS PH 6 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 120000 Owner Contractor ------------------------ EDELWEISS GARTEN VENTURE ------------------------ CHARLES THOMAS HOMES, INC. 311 CECILIA LOOP CHARLES THOMAS COLLEGE STATION TX 778456310 P O BOX 10106 COLLEGE STATION TX 77842 (979) 696-4384 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1705.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc GS Permit Fee 520.00 Plan Check Fee .' .00 Issue Date . . . . 4/04/06 Valuation . . . . 120000 Expiration Date . . 10/01/06 Qty Unit Charge Per Extension BASE FEE 460.00 20.00 3.0000 THOU BLDG, VAL 100001-500000 60.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) ------------------- BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS , AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00001015 Page 2 Date 4/04/06 Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 30") WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE ----------------------------- --- --- ----- -- -------- BUILDING DEPT^REPR5GNNTATIVE : APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS,AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00001015 Page 3 Date 4/04/06 Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS ,AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00001015 Date 4/04/06 ---------------------------------------------------------------------------- Special Notes and Comments PRIVATE GARAGES Narrow wall Bracing Fully Sheathed ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited -------------------- Due ---------- ----------------- Permit Fee Total ---------- 520.00 520.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1270.00 1270.00 .00 .00 ------------------- BUILDING DE APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS.AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00001016 Date 4/04/06 Property Address . . . . . . 323 ROBELMONT DR Property ID . . 244030-0612-0100 R # . . . . • • • • • . . . . R301743 Application type description TEMP POLE Subdivision Name . . . . . . EDELWEISS GARTENS PH 6 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ EDELWEISS GARTEN VENTURE ------------------------ CHARLES THOMAS HOMES, INC. 311 CECILIA LOOP CHARLES THOMAS COLLEGE STATION TX 778456310 P O BOX 10106 COLLEGE STATION TX 77842 (979) 696-4384 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GS Permit Fee . . . . 20.00 Issue Date . . . . 4/04/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------- Fee summary Charged ------------------------ Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ----------------- BUILDING APPLICANT APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATJpN.TX.US ril � j For OOKae Use Only DATE. v v uI I ( c l3 APPLICATION # OrU 1O TEMP POLE # L ADDRESS/LOCATION: •� / LOT I V V LOCK __L2�—V81JIBDIVISION BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: CHARLES THOMAS HOMES, INC. PHONE: 2Z.9 - 00611- P.O. BOX 10106 CONTRACTOR ADDRESS: COLLEGE STATION, TX 77842 ELECTRICIAN: PLUMBER: . HVAC: i GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION VING SHELL ONLY DEMOLITION (Asbestos Survey) V NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL Required) DESCRIPTION OF WORK: 0 STRUCTURE USE: HOMEOWNER ASSOC IATION/ARCHITECTUAL OR DESIGN/REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY Y STANDARD (TAS) PROJECT REGISTRATION# EABPRJ HEATED AREA: =VALUATION: $ �� 000 TOTALAREA (Cost of L bor and Materials) �UBLIC SEWER EPTIC/TREATMENT SYSTEM I! VEWER TAP: — d ZE dWATER TAP: 11 ^Tvv SIZE OTHER TAP: SIZE Q TEMP POLE GARAGE TYPE: SINGLE ATTACHED SIGNATURE OF APPLICANT: NUMBER OF BEDROOMS NUMBER OF BATHROOMS INTERIOR WALL TYPE: EXTERIOR WALL TYPE FOUNDATION TYPE: ROOF TYPE: DOUBLE ro""'DETACHED = C TRIPLE AIRPORT ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ -773 V- �(-O 6- z F, ,V 6,+ximp WI)4 Official Use Only ' J _ e TO �L- NAA Y- Energy Code Compliance Information % Glazing of exterior walls Cape 4pp�, �Soar �H�os£ I (IIoard I'�2 Insulation. R value of ceiling 1 (flat areas) �p Insulation R value of ceiling 2, (vaulted areas/no attic) At ✓ Insulation R value of exterior walls Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating .P* PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning cd Development Services PLAN REVIEW/PERMIT NUMBER# � _ /d I DATE: /q /o6 BUILDING ADDRESS: a © eImv 0 . ., I. Foundation Requirements N K A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30") 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated H. Framing: Floor, Wall, Ceiling and Roof Requirements NAfOkj A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, rade, slope and purlins if required. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning d' Development Servicei II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NIF 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" WA S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes dA III. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6) inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half (9-1/2) inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) NA/IbN A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning d Development Services V. Electrical Service Requirements N A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location Vl. Plumbing Requirements NAJOJV A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/ A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements N A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N O Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements NA/ Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 N.410K Does not block any water course or divert any flow Elevation certificate if required A/14 CITY OF COLLEGE STATION Planning cr Development Services Comments: PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS ,J49i�- y-q- fl 6 PLANS EXAMINER DATE I (P--Lrk) 3 0� �ow evw wr I e 1-4 C no_ CHARLES THOMAS HOMES, INC. P.O. BOX 10106 COLLEGE STATION, TX 77842 1105 !bca�z. V =)-6 MECcheck Compliance Report 2000 IECC MECcheck Software Version 3.2 Release lb TITLE: College Station Building Permits CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 04/02/06 DATE OF PLANS: 04/03/2006 PROJECT INFORMATION: 323 Roblemont Dr - Edlws Grtns[ 17051 COMPANY INFORMATION: Charles Thomas Homes, Inc. COMPLIANCE: Passes Maximum UA = 798 Your Home = 574 28.1% Better Than Code Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E Door 1: Solid Door 3: Solid Door 4: Glass Door 2: Glass Slab 1: Unheated, 0.0' insul. Air Conditioner 1: Electric Central Air, 14 SEER Furnace 1: Forced Hot Air, 80 AFUE Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1705 0.0 30.0 53 1965 13.2 0.0 137 202 0.640 129 20 0.440 9 17 0.013 0 35 0.440 15 17 0.440 7 215 0.0 224 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to m t the 2 IECC requirements in eck Version 3.2 Releas 1 . Builder/Designer Date