Loading...
HomeMy WebLinkAboutRES2006-01000, 06-1001/ l - 06,tob1 OEssafte H7521f3 1096 19P4 WF0757574 / 001 City of College Station PAGE 1 REQ. DATE: 04/04/06 04/04/06 12:47:59 LOCATION: 2485 NEWARK CIR t , LOC ID: 204026 REQUESTOR: CLAY KOLBY HOMEBUILDING ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT 4" SEWER TAP AND 3/4" WATER TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/04/06 SCHED COMPLETION: 04/04/06 ******************************************************************************** JOB ORDER RESULT CONIlVfEDPPS WF0760930 / 001 City of College Station PAGE 1 REQ. DATE: 04/18/06 04/18/06 14:03:13 LOCATION: 2485 NEWARK CIR LOC ID: 204026 REQUESTOR: CLAY KOLBY HOMEBUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 04/18/06 SCHED COMPLETION: 04/18/06 ******************************************************************************** JOB ORDER RESULT COMMENTS (*hr"" CITY OF COLLEGE STATION Planning d' Development Services PLAN ,REVIEW ONE andQW0 FAMILY OCCUPANQY.S,EQUIREMENTS PLAN REVIEW/PERMIT NUMBER# _ poa DATE: 41 /3/ /a 6 BUILDING ADDRESS: I. Foundation Requirements NA/ A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, rade, slope and purlins if required. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY„REQUIREM ENTS CITY OF COLLEGE STATION Planning c4 Development Service) II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NA/ 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18' S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes III. Stairway Requirements N K A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements (to be indicated on plans) N K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning dDevelopment Services V. Electrical Service Requirements NA/f K A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements N A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 NAM Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 N K Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 K Does not block any water course or divert any flow Elevation certificate if required �T (*hrq" CITY OF COLLEGE STATION Planning d Development Services Comments: PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLANS EXAMINER DATE 56 ,34 21, 59' �I SAO 49 JA�tV(L- 30,67' 70,00, RFScheck Compliance Certificate 2000 IECC REScheck Software Version 3.6 Release la Data filename: C:\Program Files\Check\REScheck\Job 124.rck PROJECT TITLE: Job 124 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.11 DATE: 04/03/06 DATE OF PLANS: 4/3/2006 PROJECT DESCRIPTION: Jares Residence DESIGNER/CONTRACTOR: Clay Kolby Homebuilding COMPLIANCE: Passes Maximum UA = 756 Your Home UA = 421 44.3% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.28 Ceiling l: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Vinyl Frame:Double Pane with Low-E SHGC: 0.27 Door 1: Solid Door 2: Glass SHGC: 0.36 Furnace 1: Forced Hot Air, 78 AFUE Air Conditioner 1: Electric Central Air, 14 SEER Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimet R-Value R-Value U-Factor 2419 0.0 30.0 75 2796 13.0 0.0 201 293 0.390 114 28 0.640 18 20 0.640 13 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 3.6 Release la (formerly MECcheck) and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. I Builder/Designer �:� L'I— Date .I RFScheck Inspection Checklist 2000 IECC REScheck Soltware Version 3.6 Release la DATE: 04/03/06 PROJECT TITLE: Job 124 Bldg. Dept. Use Ceilings: [ ] I 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation Comments: I Above -Grade Walls: [ ] I 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: I Windows: [ J I 1. Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.390 For windows without labeled U-factors, describe fmtures: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: I Doors: [ ] I 1. Door 1: Solid, U-factor. 0.640 Comments: [ ] I 2. Door 2: Glass, U-tctor. 0.640 Comments: I Heating and Cooling Equipment: [ ] I 1. Furnace 1: Forced Hot Air, 78 AFUE or higher Make and Model Number [ ] I 2. Air Conditioner 1: Electric Central Air, 14 SEER or higher Make and Model Number I Solar Heat Gain Coefficient: [ ] I The area weighted average Solar Heat Gain Coefficient (SHGC) ofall glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. I Air Leakage: [ ] ( Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] I Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: [ ] I Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals f5r all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-factors, and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Dud Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] The RVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required i'or each separate HVAC system. A manual or automatic means to partially restrict or shut offthe heating and/or cooling input to each zone or door shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55'F must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts 1.25" Circulating 1.5" to Mains and Runouts Over 2„ 2.0" Temperature (Fl 14P to 1„ 170-180 0.5 Un to 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ( F) 2" Runouts 1" and Less 1 25" to 2" 2,511 to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) PREPARED 8/30/06, 12:03:44 INSPECTION TICKET PAGE 2 City of College Station, INSPECTOR: BUILDING INSPECTOR DATE 8/30/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 2485 NEWARK CIR SUBDIV: CASTLEGATE PH 5 SEC 2 CONTRACTOR CLAY KOLBY HOMEBUILDERS PHONE (979) 777-9840 OWNER . . PHONE PARCEL . . 184200-2501-0070 APPL NUMBER: 06-00001000 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/17/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00 4/17/06 AP T/S: 04/13/2006 02:58 PM GLSOUTH ----------------------- Strings On Setbacks O.K. Slab Ground Installed B115 01 6/27/06 OC BLDG, FRAMING TIME: 17:00 6/27/06 AP June 23, 2006 8:58:30 AM kwolfe June 27, 2006 12:42:32 PM kwolfe B130 01 6/30/06 BH BLDG, INSULATION TIME: 17:00 6/30/06 AP June 30, 2006 2:03:33 PM kwolfe June 30, 2006 2:03:47 PM kwolfe B125 01 /30/06 BI BLDG, FINAL TIME: 17:00 P31 - ��3 Is August 30, 2006 9:00:09 AM kwolfe -------------------------�------ CONTINUED ONTO NEXT PAGE----------------------------------- �n��%opt 66- 1000 Application to Stock/Fixture/Move-in Prior to _ Certificate of Occupancy Issuance of a Cert p y CITY OF COLLEGE STATION Property Address: Company Name: Business Name: Property Owner or Manager Information: Name: Address: City, State, Zip: Phone: Construction Company Information: Name: I Address: City, State, Zip: Phone: -7ggO Mobile: Mobile: I amapplying for permission to: / ✓ Move furniture and/or equipment into the building Fixture and/or stock the building Conduct training for staff members only Other (Be Specific) S I hereby make application to the City of College Station to perform the action(s) indicated above without the benefit of a Certificate of Occupancy. I certify that the above statements are true and correct. I understand that occupancy of a structure prior to obtaining a Certificate of OcciWancy is a code violation and may result in the issuance of citation(s). I further undersstt, h FE!i as ' ed with citations range up to $2,000.00 per day. Applicant Signature: Printed Name: Date: - 3 _ 6(-. ♦♦1111111111111111111111111111111111111111111111111111111111♦♦1111♦ Building Department Representative: Comments: Date: City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning 8/31/06 184200-2501-0070 2485 NEWARK CIR COLLEGE STATION TX 77845 CASTLEGATE PH 5 SEC 2 CASTLEGATE SEC 5, PHS 2, BLOCK 1, LOT 7 PLANNED DEVI, HOUSING Owner . . . . . . . . . CLAY KOLBY HOMEBUILDING LLP Contractor . . . . . . CLAY KOLBY HOMEBUILDERS 979 777-9840 Application number Description of Work Construction type . . . Occupancy type . . . . Flood Zone . . . . . . Approved . . . . . . 06-00001000 000 000 RESIDENTIAL, 1 UNIT DETACHED NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX W�T 16 wa� Building Official VOID UNLESS SIGNED BY BUILDING OFFICIAL BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- r Application Number . . . . . 06-00001000 Date 4/04/06 Property Address . . . . . . 2485 NEWARK CIR Property ID: 184200-2501-0070 R #. Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 190000 Owner Contractor - ----------------------- ------------------------ CLAY KOLBY HOMEBUILDERS P O BOX 8 NAVASOTA TX 77868 (979) 777-9840 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2419.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 441.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . BK Permit Fee . . . . 730.00 Plan Check Fee .00 Issue Date . . . . 4/04/06 Valuation . . . . 190000 Expiration Date . . 10/01/06 Qty Unit Charge Per Extension BASE FEE 460.00 90.00 3.0000 THOU BLDG, VAL 100001-500000 270.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS OPENING (MINIM ROUGH -FRAMED SIZE 22" ------------------------------------------ BUILDING DEPT REPRESENTATIVE: ------------------ _ " i 'r / APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00001000 Page 2 Date 4/04/06 Special Notes and Comments X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE ------------------------------------------- ------ --- - --------------- BUILDING DEPT REP SE ATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00001000 Page 3 Date 4/04/06 Special Notes and Comments WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) 40--- ----- --- -------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number . . . . . 06-00001000 Date 4/04/06 ---------------------------------------------------------------------------- Special Notes and Comments RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Narrow wall bracing Fully Sheathed ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 730.00 730.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1480.00 1480.00 .00 .00 ---------------------------------------------- ------ ---- ----- -_---------- BUILDING DEPT REPRESENTATIVE: APPLICANT: 4 z TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00001001 Date 4/04/06 Property Address . . . . . . 2485 NEWARK CIR Property ID: 184200-2501-0070 R ## . Application type description TEMP POLE Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ CLAY KOLBY HOMEBUILDERS P O BOX 8 NAVASOTA TX 77868 (979) 777-9840 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . BK Permit Fee . . . . 20.00 Issue Date . . . . 4/04/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 -------------------------------------------- Fee summary Charged ---------- ------------------------------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - APPLICATION FOR BUILDING PERMIT DATE: (l�l CITY OF COLLEGE STATION APPLICATION # 17m] 1101 TEXAS AVENUE 0 / - _ t 1 COLLEGE STATION, TX 77840 TEMP POLE # 111 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: 7"fly /U6wmw C(R LOT BLOCK ' SUBDIVISION a�AST I'F&A'TE J SEC/PH BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: C1.114`I I-§W"( gc�ic�lpV PHONE: -71�-'1'6q0 CONTRACTOR ADDRESS: R 3CA SS �Jo "6_14 1 ,C I"/ "77gVg ELECTRICIAN: &tw HVAC: t'—' d F_& e, PLUMBER: --�;3 GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL Req) DESCRIPTION OF WORK: C a'NSTnula N pvwwt STRUCTURE USE: tw4flwy- RStDn'e's HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: l/ TEXAS ACCESSIBILITY STANDARD ) PROJECT (TA T REGISTRATION# EABPRJ VALUATION: $ l'i O, O&V 7 TOTAL AREA: 17% HEATED AREA: Z`I )i (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM )I SEWER TAP: _I_ SI E �t LLB WATER TAP: 3 G SIZE OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE ATTACHED SIGNATURE OF APPLICANT: NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: a DOUBLE DETACHED Official Use Only -r) y_ y-0 G jFAd Plans Examiner � ,fl �-p cwlio wS Stf�ET�IC. sra� / �aluc TRIPLE a CARPORT a Zoning Official 11Q C ments: YES r NO Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating 2� Z