HomeMy WebLinkAboutRES2005-03950, 05-3951J
M
WF0729877 / 001 City of College Station
PAGE 1
REQ. DATE:
12/14/05
12/14/05
14:03:06
LOCATION:
3900-FAIMES CT
LOC ID:
201922
REQUESTOR:
T D T HOMES / DBA G D T INC ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
4" SWR
TAP 3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START: 12/14/05 SCHED COMPLETION:
12/14/05
********************************************************************************
JOB ORDER
RESULT COWMgTS
Kim Wolfe -Insulation request inspection result, 3900 Faimes, #05-3950 Page 1
From:
Brian Henry
To:
Southerland, Gina
Date:
1/27/2006 9:27:31 AM
Subject:
Insulation request inspection result, 3900 Faimes, #05-3950
Print for file
Inspected insulation, 3900 Faimes, #05-3950, Benchmark Homes,
1-27-06
Inspection result: Inspected OK for Good Cents
CC: Korthauer, Brittany; Wolfe, Kim
WF0730258 / 001 City of College Station
PAGE 1
REQ. DATE:
12/15/05
12/15/05
10:59:50
LOCATION:
3900 FAIMES CT
LOC ID:
201922
REQUESTOR:
T D T HOMES/DBA G D T, INC ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
TEMP POLE
PASSED
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
12/15/05 SCHED COMPLETION:
12/15/05
********************************************************************************
JOB ORDER RESULT COM ENTS
a(�r -3cj630
PREPARED 4/27/06, 8:04:53 ]INSPECTION TICKET PAGE 5
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/26/06
------------------------------------------------------------------------------------------------
ADDRESS . : 3900 FAIMES CT SUBDIV: EDELWEISS GARTENS PH 6
CONTRACTOR T D T HOMES/DBA G.D.T. INC. PHONE (979) 690-7117
OWNER EDELWEISS GARTEN VENTURE PHONE :
PARCEL 244030-0614-0130
APPL NUMBER: 05-00003950 RESIDENTIAL, 1 UNIT DETACHED NEW
-------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B100 '01 - 12/27/05 JGM BLDG, FOUNDATION -SLAB TIME: 17:00
12/27/05 AP December 27, 2005 10:01:20 AM kwolfe
early afternoon
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 1/25/06 DS BLDG, FRAMING TIME: 17:00
1/25/06 AP January 24, 2006 1:52:01 PM kwolfe
B130 01 1/27/06 BH BLDG, INSULATION TIME: 17:00
1/27/06 AP January 30, 2006 10:18:29 AM kwolfe
January 30, 2006 10:21:27 AM kwolfe
B125 01 /26/06 BLDG, FINAL TIME: 17:00
April 26, 2006 3:27:56 PM bkorthauer
----------------------------------- COMMENTS AND NOTES------------------
Date: 4/27/2006
Inspection Comments for Finals
Permit Year: 5 Permit Number: 3950
Address: 3900 FAIMES CT
Type
Inspection Type Code
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B130
BLDG, INSULATION
IC
January 30, 2006 10:21:27 AM kwolfe
P105
PLBG, TOP OUT
IC
01/17/2006 10:20 AM JGM PDA
P105
PLBG, TOP OUT
IC
need work platform in front of waterheater, proper
P105
PLBG, TOP OUT
IC
clearance from combustibles top of waterheater
Page 1
BUILDING PERMIT
CITY C-F C6hLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 05-00003950 Date 12/14/05
Property Address . . . . . . 3900 FAIMES CT
Property ID: 244030-0614-0130
R #: R301792
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . EDELWEISS GARTENS PH 6
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 105666
Owner Contractor
------------------------ ------------------------
EDELWEISS GARTEN VENTURE T D T HOMES/DBA G.D.T. INC.
311 CECILIA LOOP GLENN THOMAS
COLLEGE STATION TX 778456310 1110 12TH MAN
COLLEGE STATION TX 77845
(979) 690-7117
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . .. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK & STUCCO
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1601.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 405.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . KW
Permit Fee . . . . 478.00 Plan Check Fee .00
Issue Date . . . . 12/14/05 Valuation 105666
Expiration Date . . 6/12/06
Qty Unit Charge Per Extension
BASE FEE 460.00
6.00 3.0000 THOU BLDG, VAL 100001-500000 18.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
------------------------------- - -----------------------
BUILDING DEPT REPRI�%ENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 05-00003950 Date 12/14/05
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other.means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION,, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 05-00003950 Date 12/14/05
----------------------------------------------------------------------------
Special Notes and Comments
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS.' CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Exterior walls located on property line shall have a one
hour fire resistance rating without openings. Overhangs
extending over the property line shall have a one hour fire
resistant construction on the under side,without openings
and shall extend a maximum of 18". Slab edge shall be
----------------------------------------------Q-4--1 --------------------
BUILDING DEPT REPRE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number
. . . . .
05-00003950
Date 12/14/05
----------------------------------------------------------------------------
Special Notes and
Comments
built on property
line.
0-lot side to be
brick from
slab to soffit.
Re
move hose bib on
0-lot side.
Narrow wall bracing
fully sheathed.
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited.
Due
Permit Fee Total
478.00
--------------------
478.00
.00
----------
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1228.00
1228.00
.00
.00
------------------------- -- - - ---------------- - - - - - -
BUILDING DEPT REPRESENTATIVE —
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 05-00003951 Date 12/14/05
Property Address . . . . . . 3900 FAIMES CT
Property ID: 244030-0614-0130
Application type description TEMP POLE
Subdivision Name . . . . . . EDELWEISS GARTENS PH 6
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner
Contractor
------------------------
EDELWEISS GARTEN
VENTURE
------------------------
T D T HOMES/DBA G.D.T. INC.
311 CECILIA LOOP
GLENN THOMAS
COLLEGE STATION
TX 778456310
1110 12TH MAN
COLLEGE STATION
TX 77845
(979) 690-7117
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. KW
Permit Fee . . .
. 20.00
Issue Date . . .
. 12/14/05
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees .. . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
------------------------------
Due
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
-------------------
BUILDING DE
APPLICANT:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
(*hr""
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning of Development Service
WWW.CSTX.GOV
ADDRESS/LOCATION:
F-P,1 ey-) r S Co t)
p" ForOf ke Use Only
DATJ I
APPLICATION # OC9
�Aw
LOTCK 1SUBDIVISION ����$ +_� �-
c,� a --a BUSINESS/OWNER NAME: G— PHONE:_ / n (r�
, 1
CONTRACTOR/HOMEOWNER: '^�� �' y � � M,6--S PHONE:__q 'Z I- Ifle-G P
CONTRACTOR ADDRESS: �� Z`t� MIQ (2pVe—
ELECTRICIAN: 6,c
HVAC: P► �► rr--
a `
PLUMBER: VS`t�� Q
GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK: •.� Y
� 1
STRUCTURE USE:
4_
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE PPROVAL:_
TEXAS ACCESSIBILITY STANDARD (TAS),PROJECT REGISTRATION'# EABPRJ�
VALUATION: $ TOTAL AREA: or $-`--f- HEATED AREA: I
(Cost of Laband Materials) //,,,,
PUBLIC SEWER IOS1 G � NUMBER OF BEDROOMS: _.,,)
SEPTIC/TREATMENT SYSTEM
SEWER TAP: "I
IZE III
WATER TAP: ed
SIZE
OTHER TAP:
SIZE
Ix TEMP POLE
NUMBER OF BATHROOMS: pC
INTERIOR WALL TYPE: pGLJV1
c^ �
EXTERIOR WALL TYPE:
FOUNDATION TYPE: (1 1 L�� O ICI ��if`'P��► f?1
ROOF TYPE:
GARAGE TYPE: SINGLE a DOUBLE [g TRIPLE a
ATTACHED
SIGNATURE OF APPLICANT: p 4 <64ti
*If proposed work involves new comm-e-iV61 construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
ES r NO
,� Plans Examiner Zoning Offi ' I
L O-Le4 Co,,Sn/o D NB Nod �4G1-4
-So (Jok 1� ylk Qw D fib S W }' sa t`fl�
m
3 ctoo FAIMES COURT
b aFOR EDELWE65 BENCHMARK HOMES
SITE PLAN LOT= 13 PNA5E rATW Asp I, 601 ga. ar.
BLOCK, 14 5LAH AREAS N H A� S
5CA�E �' 20' � FAIMES COURT 2� 140 5A. F?. �, FAX,
(+Dv) ero-nn (404) wanle
PLAN REVIEW
ONE and TWO FAMILY
CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS
Plmninj d Divelopment soviea
PLAN REVIEW/PERMIT NUMBER#
BUILDING ADDRESS:
Dgg=iq
prO ICA1,M
I. Foundation Re uirements
A. Concrete minimum f'c of 3000 PSI
NAI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or - la out shown
I. Footinis/beams are continuous over the len th and width of foundation
2. Dimensions
3. Footin s 30" exterior, 24" interior unless over 60' long then 30"
4. Spacinq
of beams does not exceed 15'
E. Reinforcement details to meet minimum re uirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framin :Floor Wall, Ceiling and Roof Re uirements
A. Girder or sill dimensions grade & species
NAI
B. Floor joist sizes acingrade & direction of span indicted on plans
C. Treated sill plate or bottom late
D. Narrow Wall Bracin Methods indicated on plans
E. Header sizes indicated on ptans
F. EmergiencY bedroom egress
1. Exit direct to outside
2. O erable window
a. Twen 20 inch clear width b twenty-four 24 inch clear hei ht
b. Maximum sill helligil it of fo -four 44
inches above finished floor
G. Operable bathroom window re uired when mechanical ventilation is
H. Stud rade ands acin not rovided
I. Exterior wall details
1. Exterior wall coverin indicated on plans
2. Slheathli 111 1 indicated on plans
3. Moisture barrier indicated on plans
J. Roof framin Ian or elevation shown
K. Ceilingjoist size nacing, grade and direction of span indicated on lans
L. Attic access location and size indicated on plans
located In giaranle it is not to exceed 30" x 54"
M. Span exceeding, code tables must be engineered
N. Rafters sizes apaning grade,sloe and pudins if required.
%
� PLAN
REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning d Dtvtlopmint Soviets
i. naming; Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on tans
Q. Tempered Glass required in all hazardous locations
R. Overhangs -allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
A Stairway DPtnilc
.1 . Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairwav risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow ed e
Z. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow ed e
C. Spiral stairway details
1 Riser height less than nine and one half 9-1/2 inches
2. Treads a minimum of seven and one=half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. StairwaI width not less than twenty-six inches
4. Headroom re uired not less than six ft six 6'-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairwa s located four or. more risers above floor/ rade
3. Handrails must be thrrty-four to thirty-eight (34-38) inches when measured from the
leadin ed a of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairwa
5. Guards must be a minimum of thi -six 36 inches above finished floor
6. Guards & handrails along open -sides) of stairway must have intermediate
railing or uprights that revent the Passa2e of a four 4 inch sphere
Fireplace Requirements (to be indicated on plans)
A Hearth extenSinnc
1.
ace
. ynlmneys must e
least two (2) feet
9 6 sq, ft, (extensions: 8" & 16" forward)
9 6 sq. ft. (extensions: 12 side & 20" forward)
as 2" clearance from all combustible materials
at least three (3) feet higher than the highest point of roof & at
than any portion of the building within ten (10) feet horizontal
.i
CITY OF COLLEGE STATION
Planning d• DjWjopmmf Snjea
V. Electrical Service Requiremen
A. Electrical plan to include•
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
4. Are fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
A Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18* when installed in the garage or room directly off garage
VII. Mechanical Requirements
A All mecha;1 ventilation's in bathrooms & range hood ventilation must be ducted to
outside (excludes ductless units)
B. Attic installed HN.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be rovided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vlil. Ener y Requirements
A. Compliance software work sheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zonin Ordinance Re uirements — Ordinance 860
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Real flrad portf in
On zero lot side 18* max. overhang allowed
Street Ordinance Requirements
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
Approved subdivision
Regulatlons — Ordinance 13011
s not block any water course or divert any
ration certificate if required
,.A
YIV
'CM OP COLLEGE STATION
Planning d Drwlopint &njca
Comments:
PLANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
DATE
CITY OF COLLEGE STATION
Pknnbg &D"kpremr &raker
Storm Water Discharge Perm
Texas Pollution Discharge Elimination System General Permit NO TXR 150000,
The State of Texas assumed regulatory authority over storm water discharges associated with
construction activities, effective March 5, 2003. The regulatory requirements under the general
.permit are based upon the area of land disturbed and are classified into two categories:
Large Construction Activity: 5 or more acres of disturbed land or part of a ar er common la
development that will disturb 5 or more acres. I g p n of
1. Obtain a copy of TPDES GP No. TXR 150000
2. Develop and implement a Storm Water Pollution Prevention Plan
3. Two days prior to the start of construction, submit a Notice of Intent to TCEQ
4. Provide a copy of the Notice of Intent to the City
5. Submit a Notice of Termination to TCEQ once the site has reached final stabilization
Small Construction Activity: at least 1 but less than 5 acres, or is part of a larger common plan of
development that will disturb at least 1 but less than 5 acres.
1. Obtain a copy of TPDES GP No. TXR 150000
2. Develop and implement a Storm Water Pollution Prevention Plan
3. Prior to starting construction, post a Construction Site Notice as in Part II.D.2 at the site
4. Provide a copy of the Construction Site Notice to the City
Additional information can be obtained from:
TCEQ Website: www.tnrcc.state.tx.us/permitting/water erm/ww erm/construct.html#additional
This website provides all associated documents and explanations including NOI, GP, etc.
Compliance assistance can be obtained from: Donnie Willis
Drainage Inspector
City of College Station
979-764-6375
dwillis@cstx.gov
Larger Common Plan of Development — A construction activity is part of a larger common plan of
development if it. is completed in separate stages, separate phases, or in combination with'other
construction activities
Example 1: A subdivision is being built. You are grading 0.75 acres, another company is clearing 4
different acres, and a contractor is excavating another 0.5 acres. In this case, the total area that
would be disturbed is 5.25 acres, so each contractor would fall under the requirements associated
with disturbing 5 or more acres.
Example 2: At first, your project calls for you to grade, clear, or excavate a total of 0.93 acre. But
after your project begins, you learn that you must disturb another 0.15 acre. Because this project
has grown to disturb a total of 1.08 acres, you must obtain coverage under the uirements for
disturbing 1 to less than 5 acres. req
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
REScheckSoftware Version 3.5 Release la
Data filename: C:\Program Files\Check\REScheck\REScheck docs\184TDT.rck
TITLE: TDT Job 184
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 11 /05/05
DATE OF PLANS: November 15,2005
PROJECT INFORMATION:
TDT Homes
Job 184
Lot 13 Block 14 Edelweiss Gartens 6
3900 Faimes Court
College Station, TX 77845
COMPANY INFORMATION:
TDT HOMES
1110 12th Man
College Station, TX 77845
NOTES:
Like 103 Rugen with more S/ ft. and new elevation.
COMPLIANCE: Passes
Maximum UA = 669
Your Home UA = 507
24.2% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.34
Ceiling 1: Flat Ceiling or Scissor Truss
Ceiling 2: Cathedral Ceiling (no attic)
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.34
Door 1: Solid
Door 2: Glass
SHGC: 0.34
Door 3: Glass
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor
UA
1431
30.0
0.0
50
170
30.0
0.0
6
1603
13.0
0.0
113
165
0.650
107
21
0.300
6
18
0.570
10
18
0.570
10
SHGC: 0.34
Floor 1: Slab-On-Grade:Unheated 197 0.0 205
Insulation depth: 0.0'
Furnace 1: Forced Hot Air, 80 AFUE
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Rel Ila(formerly MECchecl and to comply with the mandatory requirements listed in
the RES checkInspection C list.
Builder/Designer 1' �� Date
REScheck Inspection Checklist
2000 IECC
REScheckSoftware Version 3.5 Release la
DATE: 11 /05/05
TITLE: TDT Job 184
Bldg.
Dept.
Use I
Ceilings:
1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
2. Ceiling 2: Cathedral Ceiling (no attic), R-30.0 cavity insulation
Comments:
Above -Grade Walls:
1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
1. Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.650
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
1. Door 1: Solid, U-factor: 0.300
Comments:
2. Door 2: Glass, U-factor: 0.570
Comments:
3. Door 3: Glass, U-factor: 0.570
Comments:
Floors:
1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
1. Furnace 1: Forced Hot Air, 80 AFUE or higher
Make and Model Number
2. Air Conditioner 1: Electric Central Air, 13 SEER or higher
Make and Model Number
Solar Heat Gain Coefficient:
The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly
marked on the building plans or specifications.
Duct Insulation:
[ ] Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
I
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in
Inches by Pipe Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature ( F)
Up to 1„
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Piping System Types
Range F
2" Runouts
1" and Less
1.25"
to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5