HomeMy WebLinkAboutCNEW2005-03934D5- 313 r !4, Arcbitecture, Design c5 Planning 117orldwide GORI` IeW July 26, 2006 Benjamin McCarty City of College Station Development Services 1101 Texas Avenue South P.O. Box 9960 College Station, Texas 77842 RE: Adam Plaza Application #05-3934 Dear Mr. McCarty, This letter is in reference to the monumental stair from the 9`h to 10`h floors of Adam Plaza. It is part of the project submitted in October 2005 under the 2000 IBC. The referenced stair is an interconnecting stair that connects the 901 and 10`h floors. It is not a required exit stair and the building is fully sprinkered. Per our conversation earlier today and your previous conversation with the building official, it is my understanding that since our building is fully sprinklered we are not required to provide a 1- hour enclosure around our stair opening nor a draft curtain. (Per section 404.3.) I look forward to your response and confirmation of these findings. Sincerely, Corey Credeur, AIA Associate Pennzoil Place 700 Milam Screec Suite .{00 Houston Texas 77001 Tel: 713. 118. Soso Fax: 713. 129. 9343 Archirecrure, Design & Planning Worldiuirle Gensler January 12, 2006 Benjamin McCarty City of College Station Development Services 1101 Texas Avenue South P.O. Box 9960 College Station, Texas 77842 RE: Adam Plaza Dear Mr. McCarty, We are in receipt of your letter dated December 20, 2005. In response to your letters dated December 20, 2005 regarding 9th floor Core Lobbv Area and loth floor Offices — First American Blvd: Application #05-3934 /��f1. Need to submit information regarding the plan to block off finished areas from unfinished TY�__ future tenant spaces, including elevator doors. �Q `n" ��•� The unfinished future tenant spaces will be blocked off using partitions as .scheduled on C the drawings. Doors with locks are provided into all unoccupied spaces with free egress from those spaces. Submit details on the fireplace in Mr. Adam's office. Details have been added. Refer to revised Sheets A11.59 and Al2.65 Pennzoil Place -oo Nfilan: Street Suite 400 Houston Texas 77002 -lel: 7/13. 225. 8050 Fax: 713. 229. 9343 Gensler d3I--,' Verify the accessibility of the telephone room near the boardroom to comply with section 704 of the ICC/ANSI Al 17.1-1998, Accessible and Useable Buildings and Facilities. Section 704.2.1—The clear floor area in the telephone room is 60 'X60"with an additional 21 " of knee -room below the countertop. Section 704.2.1.2 — The telephone will be a countertop phone and will be less than 20 inches away from the front edge of the counter. Section 704.2.2 — Operable parts of the telephone will be within the reach ranges specified in Section 308. The telephone will sit on a counter that is 30 1/2 "aff. Section 704.2.3 — No telephone directories are provided. Section 704.2.4 — The owner to ensure that the handset cord length will be 29 inches minimum. Section 704.2.5 — The owner to ensure that the telephone shall be hearing -aid compatible. Section 704.3 — The owner to ensure that if the telephone has volume control it will be equipped with a receive volume control with a range that provides 12 dB of gain minimum and 20dB of gain maximum. An automatic reset shall.be provided. Section 704.4 and 704.5 —pay telephones are not used. Section 704.5 - The clear knee -space below the counter is 27 Y2 "aff. Submit verification of smokeproof enclosures for all stairways and their exit passageways to comply with section 909.20 of the 2003 IBC. Stairwells and exit corridors are part of the base building and not in this scope of work. Refer to the base building permit for compliance. NpTE S1 Need to verify and submit automatic fire alarm and emergency voice/alarm communication system prior to installation to comply with section 907.2.12 of the 2003 International Building Code. The automatic fire alarm and emergency voice/alarm communication system will be submitted separately by the fire alarm sub -contractor. No Need to submit fire sprinkler plans prior to installation. See response above to item 2. The fire sprinkler plans will be submitted separately by the fire sprinkler sub -contractor. Pennzoil Place ,00 Nlilam Streec Suife :goo Houston Texas -7 , o o z Tel: 77 i. 228. 8050 Fax: 713. 129. 9343. Gensler Need fire extinguisher size and location to comply with the City of College Station Fire Marshall's Office. Per the 2003 IBC, Section 906, Portable fire extinguishers shall be provided in occupancies and location as required by the International Fire Code. Per the 2003 International Fire Code, Section 906.1, Portable fire extinguishers shall be installed in the following locations: L In all Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In all Group A, B and E occupancies equipped throughout with quick response sprinklers, fire extinguishers shall be only in special -hazard areas. Afire extinguisher has been provided in Catering 1051 per the IFC Section 906.1 (2) Within 30 feet of commercial cooking equipment. Size is per Specification Section 10520, attached No other fire extinguishers are required. Need to submit complete lighting plan for permitted area, please include all emergency lighting, required exit signs and exit stairway lighting to comply with section 1006 of the 2003 International Building Code. Exit signs are provided on sheets E4.09 and E4.10. Refer to Lighting drawings for emergency lighting and exit discharge emergency lighting to be issued by the General Contractor. Provide stairway floor number signs throughout both stairways to comply with all of section 1019.1.7 of the 2003 IBC. Stairways are part of the base building and not in this scope of work. Refer to the base building permit for compliance. Provide information on the door hardware, including any lock and latch devices, and emergency exit panic hardware on all exterior [exit doors] to comply with sections 1008.1.8.1 and 1008.1.9 of the 2003 IBC. The door hardware on all exit stairs is part of the base building. Refer to the base building permit for compliance. We are changing out the lever on the corridor side to match the rest of the hardware on the floor and are adding an electronic hinge as shown in Specification Section 08711, which do not alter the compliance with the 2003 I4C nzoil Place 700 Milani Street Suite 400 Houston Texas 7 7 0 0 , Tel: 713. 128. 8050 Fax: 7a i. z29. 9343 Benja:4°tin McCa - Re: Adam Plaza - Permitting _Pa:!ge 1 From: "Marq Synwolt" <msynwolt@madison-construction.com> To: "Benjamin McCarty" <BMcCarty@cstx.gov> Date: 1 /25/2006 12:59:38 PM Subject: Re: Adam Plaza - Permitting Ben, In response to your letter to Gensler dated January 24, 2006 we have confirmed the following with Bouyea and Associates / Lutron: f-Ci ui' it C-8 all sconces in the Dining Room, sheet LC00-01 B) will be added to emergency panel DP1-EM'to comply with section 1006.3 of the 2003 International Building`Code. 2. Circuit Referenced C-1 on emergency panel DP1-EM will actually be Lesignated-as'a sparr_e. 3.jCircui� t CR1 tenth floor corridor 1000A, 1000B_and 1000C (sheet LC00=10) ,will be added to the emergency panel DP10-EM ,j We hope that this information sufficiently addresses items 1,2 and 3 of your January 24, 2006 letter to Gensler. We have yet to receive clarification of items 4, 5 and 6 (Application # 05-3935 Finish -out of office building garage) that you addressed on your January 24, 2006 letter to Gensler. Please let me know if you need further information or documentation. Thank You, Marq D. Synwolt Application #05-3932 (1 st Floor Amenity Wing) ----- Original Message ----- From: "Benjamin McCarty" <BMcCarty@cstx.gov> To: <msynwolt@madison-construction.com> Sent: Tuesday, January 24, 2006 4:31 PM Subject: Adam Plaza >1 sent the attached letter to architect Bonny McLoud of Gensler > Benjamin McCarty '00 > Commercial Plans Examiner > City of College Station > 1101 Texas Avenue > College Station, TX 77842 > 979.764.3570 > College Station. Heart of the Research Valley. Benjamin McCart - Re: Adam Plaza- Permitting Page 2 CC: "Matt Nash" <matt@madison-construction.com> CITY OF COLLEGE STATION Planning er Development Services A -,en•' I/I g��b V✓i.1� Ss+ I la., L' l rv»Y «- p o m.- s n r- -ow 4— be 41&e14 u' +o u 0 �P//o.. s & A— �nVG �BO✓5 �0✓v9rraw�a�i rLe'7F D�eH l� H F+�r..SGv-0' 7 l GBrS. �P3 .o 4:' do3.o2 N«'W4 1�o r- e -C, '.�L- CP O -1 7-- / (f . f34 N l� Are.— ^ NyT`f �NC �� �L.' f S ��5 ✓+ R IJ O H �IQ m" r S I ✓1 R r� I� firCa PEQC'w vl/Iwli�✓Rwq f �TYD e . n S%R • r �...�`.y �%m ey YI a &I" li t r f ON 1 Y rPC.: C N:.*-5,e- � /° mw�,. �a.�:w•^e. _> ,hPoe Goy ✓es' 50► -fps, 't 4o.1F �0►r� S�/n h,o 3 clp*q P.O. BOX 9960 • 1101 TEXAS AVENUE COLLEGE STATION • TEXAS • 77842 j 979.764.3570 WWW.CSU(.gOV CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 FACSIMILE COVER SHEET Date: _ o / /zy f o & # of pages including cover: 3 If you did not receive a complete fax please call our office immediately for a new transmittal. TO: 6011r2y Tea- M a z-ow/ COMPANY: Ue h s /e ,,- RE: Aa(a H-, J01 R z, - FAX: -7/3-zZ9-93�l3 COMPANY: City of College Station, Development Services REMARKS: ❑ Urgent RTFor your review ❑ Replay ASAP FYI �Lle �e %�Pv wr'�� H ctG�r.�✓e SS Sw, re q yrrk�. —rk7a n k CITY OF COLLEGE STATION Planning d- Development Services January 24, 2006 Re: Adam Plaza- 2nd Submittal Plan Review for the listed Tenant Finish -out. Dear, Bonny Jean McLoud I have completed the plan review for the above referenced project and have the following comments. The plan review is based on the 2003 International Codes, the 2002 National Electrical Code and our local amendments. Where appropriate, I have included the applicable code sections. Application #: 05-3932 (First Floor Amenity Wing) 1. Provide emergency lighting in Dining Room to comply with section 1006.3 of the 2003 International Building Code. 2. Verify location of Circuit C1 on sheet LC00-01B for emergency power panel DP 1-EM. Application #: 05-3934 (Ninth Floor Core and Tenth Floor Offices) 3. From sheet LC00-10, Circuit CR1.2 of tenth floor corridor 1000A, 1000B, and 1000C needs to be added to emergency power panel DP 10-EM. Application #: 05-3935 (Finish -out of office building garage) 4. The plans show that computer and electrical equipment are intended to be located within the UPS/IDF room, therefore details and size of equipment are required to complete the plan review and approve for a building permit. If the room is not for UPS or IDF equipment, then the equipment and UPS/IDF room labels on the plans must be removed from all plan sheets, and relabeled to your proposed use. 5. The door swing on the mechanical room needs to be change to swing toward the direction of egress before a building permit will be issued. The mechanical room is subject to new plan review and code compliance because modifications or new equipment not part of the base building are introduced. 6. If the UPS room is to remain for that purpose, then its door(s) swing will also need to be changed out towards egress. The UPS room may require a second means of egress depending on the size of the equipment. The review does not include any civil or zoning issues or NRA requirements of the Unified Development Ordinance. Please respond to the plan review comments at your P.O. BOX 9960. 1101 TEXAS AVENUE COLLEGE STATION • TEXAS • 77842 979.764.3570 www.csb(.gov convenience. Three sets of plans addressing these issues will be required. Should you have any questions, contact me at 979-764-3570. Thank You Ben McCarty Plans Examiner TRANSMISSION VERIFICATION REPORT DATE DIME FAX NO./NAME DURATION PAGE(S) RESULT MODE TIME 01/23/2006 23:03 NAME COCS DEVELOPMENT SER FAX 9797643496 TEL 9797643570 SER.# BROE2J341073 01/23 23:02 917132299343--170 00: 00: 40 03 OK STANDARD ECM CITY OF COLLEGE STA110N DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77,942 Phone 979.764.3570 / Fax 979.764.3496 FACSIMILE COVER SHEE r Date: d / "Z� `/ /-- 6 _ #� of Pages uicludling cover; 3 If you did not re=' e a compote fox, please cell Our office tmmecliaf* for a new transmittal. TO: 600r?y lea H Mc LooW FAX: -213 - .;>- 2-g f 9 3 y 3 COMPANY: &e Y2 s /e -- RE• A: -(a a"-, 1 a Z ^ -- %&ev, me, (f-,ct0- PROVIDE SEPARATION OF UNFINISHED FLOORS FROM HAVING ACCESS BY ELEVATOR DOORS, NEITHER BY PROGRAMMING ELEVATOR TO NOT STOP AT UNFINISHED FLOORS OR PROVIDE PARTITION WALLS AT EACH ELEVATOR DOOR TO PROHIBIT ACCESS AND EXITING ELEVATORS ONTO UNFINISHED FLOORS ONLY. ALL STAIRWAY FLOOR NUMBER SIGNS THROUGHOUT BOTH STAIRWAYS MUST BE INSTALLED AND APPROVED PRIOR TO ANY TENANT SPACE CO. 1. 1. 0 MADISON CONSTRUCTION, L.P. 40, MEMORANDUM DATE: January 19, 2006 TO: City of College Station Attn: Ben McCarty TELE: FAX: 979-764-3570 979-764-3496 FROM: Marq D. Synwolt TELE: FAX: 979-268-5520 979-268-6022 RE: Adam Plaza — Gensler Responses (Basement & 9th/10th floor) Pages Sent Including This Memo 00 MESSAGE: Ben, For your use and Information we are forwarding the following items from Gensler and Madison: lea — letter dated January 12, 2006 from Gensler. lea — Specification section 10520 — Fire Extingushers. lea — Sheets A11.59, Al2.65, A02.0B and E5.01 dated. lea - Dimmer Panel Schedules (BB&A / Lutron dated Jan. 17, 2006) Please call me at 979-268-5520 or 979-412-1017 if I can be of assistance in any way. Thank you, IF THERE IS ANY PROBLEM WITH THIS TRANSMISSION PLEASE CONTACT 979-268-5520. P. 0. BOX 3787 - BRYAN, TEXAS 77805-3787 T MADISON CONSTRUCTION, L.P. LETTER OF TRANSMITTAL TO: City of College Station — Planning and Development Serv. 979-764-3570 979-764-3496 (f) VIA: DATE: 01/20/06 PROJECT: Adam Plaza — College Station, Texas ATTN: Ben McCarty We Are Sending You X ATTACHED UNDER SEPARATE COVER VIA The following items: I I Shop Drawings I I Specifications I X I Plans I I Product Data I The following quantities and descriptions are included: QTY I DESCRIPTION OF ITEM 3 Copies Lighting Drawings: L00-01A, L00-01B, L00-02, L00-09, L00-10, LC00-0IA, LC00-0113, LC00-02, LC00-09 and LC00-10. 2 Copies Gensler Drawings (Bulletin #3): Al 1-59, Al2-65, A02-OB and E5-01. 3 Copies Gensler Drawings (Bulletin #2): A02-01A. 2 Sets Lighting Dimmer Panel Schedules: (BB&A /Lutron dated Jan. 17, 2006) These are Transmitted as Checked Below: FTT As requested I I Approved as Submitted T7Resubmit X For your Use REMARKS: please call me at 268-5520 or 412-1017 if you need an further information. Thank You, f1l (-�, , Marq D. Synwolt" Project Superintendent P.O. BOX 3787 • BRYAN, TEXAS 77805-3787 9 TELE 979-268-5520 • FAX 979-268-6022 Gensler 02.3101.000 October 7, 2005 Issue for Permit, Pricing & Construction SECTION 10520 —FIRE EXTINGUISHERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Portable fire extinguishers. 2. Fire -protection cabinets. 3. Mounting brackets for fire extinguishers. Adam Plaza 1.2 SUBMITTALS A. Product Data: For each type of product indicated. 1. Fire Extinguishers: Include rating and classification. 2. Fire -Protection Cabinets: Include door hardware, cabinet type, trim style, panel style, and details of installation. B. Samples: For each exposed cabinet. finish. C. Maintenance data. 1.3 QUALITY ASSURANCE A. NFPA Compliance: Fabricate and label fire extinguishers to comply with NFPA 10, "Portable Fire Extinguishers." B. Fire Extinguishers: Listed and labeled. for type, rating, and classification by an independent testing agency acceptable to authorities having jurisdiction. C. Fire -Rated Fire -Protection Cabinets: Listed and labeled to comply with requirements of ASTM E 814 for fire -resistance rating of walls where they are installed. 1.4 COORDINATION A. Coordinate size of fire -protection cabinets to ensure that type and capacity of fire extinguishers indicated are accommodated. FIRE EXTINGUISHERS 10505 - l Copyright 2004 Gensler Q• Gensler October 7, 2005 Adam Plaza 02.3101.000 Issue for Permit, Pricing & Construction 1.5 WARRANTY A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of portable fire extinguishers that fail in materials or workmanship within specified warranty period. Failures include, but are not limited to, the following: a. Failure of hydrostatic test according to NFPA 10. b. Faulty operation of valves or release levers. 2. Warranty Period: Six years from date of Substantial Completion. PART 2-PRODUCTS 2.1 MANUFACTURERS A. In other Part 2 articles where titles below introduce lists, the following requirements apply to product selection: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, manufacturers specified. 2. Manufacturers: Subject to compliance with requirements, provide products by one of the manufacturers specified. 3. Basis -of -Design Product: The design for each product is based on the product named. Subject to compliance with requirements, provide either the named product or a comparable product by one of the other manufacturers specified. 2.2 MATERIALS A. Cold -Rolled Steel Sheet: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B. 2.3 PORTABLE FIRE EXTINGUISHERS A. Manufacturers: 1. Amerex Corporation. 2. Ansul Incorporated. 3. Badger Fire Protection. 4. Buckeye Fire Equipment Company. 5. Fire End & Croker Corporation. 6. General Fire Extinguisher Corporation. 7. JL Industries, Inc. FIRE EXTINGUISHERS Copyright 2004 Gensler 10505 - 2 0 Gensler October 7, 2005 02.3101.000 Issue for Permit, Pricing & Construction 8. Kidde Fymetics. 9. Larsen's Manufacturing Company. 10. Modern Metal Products; Div. of Technico. 11. Moon American. 12. Potter Roemer; Div. of Smith Industries, Inc. 13. Watrous; Div. of American Specialties, Inc. Adam Plaza B. General: Provide fire extinguishers of type, size, and capacity for each fire -protection cabinet and mounting bracket indicated. 1. Instruction Labels: Include pictorial marking system complying with NFPA 10, Appendix B. C. Multipurpose Dry -Chemical Type in Steel Container: UL-rated 4-A:60-B:C, 10-lb (4.5-kg) nominal capacity, with monoammonium phosphate -based dry chemical in enameled -steel container. 2.4 FIRE -PROTECTION CABINET A. Basis -of -Design Product: or a comparable product by one of the following: B. Manufacturers: 1. Fire End & Croker Corporation. 2. General Accessory Mfg. Co. 3. JL Industries, Inc. 4. Kidde Fymetics. 5. Larsen's Manufacturing Company. 6. Modern Metal Products; Div. of Technico. 7. Moon American. 8. Potter Roemer; Div. of Smith Industries, Inc. 9. Watrous; Div. of American Specialties, Inc. C. Cabinet Type: Suitable for fire extinguisher. D. Recessed Cabinet: Cabinet box recessed in walls of sufficient depth to suit style of trim indicated. 1. Trimless with Plaster Stop: Surface of surrounding wall finishes flush with exterior finished surface of cabinet frame and door, without overlapping trim attached to cabinet. Provide recessed flange, of same material as box, attached to box to act as plaster stop. E. Door Material: Steel sheet. F. Door Style: Flush opaque panel, frameless, with no exposed hinges. FIRE EXTINGUISHERS Copyright 2004 Gensler 10505 - 3 Gensler October 7, 2005 02.310L000 Issue for Permit, Pricing & Construction Adam Plaza G. Door Hardware: Manufacturer's standard door -operating hardware of proper type for cabinet type, trim style, and door material and style indicated. 1. Provide projecting door pull and friction latch. 2. Provide concealed hinge permitting door to open 180 degrees. H. Accessories: 1. Mounting Bracket: Manufacturer's standard steel, designed to secure fire extinguisher to fire -protection cabinet, with plated or baked -enamel finish. 2. Door Lock: Cam lock that allows door to be opened during emergency by pulling sharply on door handle. 3. Identification: Lettering complying with authorities having jurisdiction for letter style, size, spacing, and location. Locate as indicated by Architect. a. Identify fire extinguisher in fire -protection cabinet with the words "FIRE EXTINGUISHER." 1) Location: Applied to cabinet door. 2) Application Process: Silk-screened. 3) Lettering Color: Black. 4) Orientation: Horizontal. I. Finishes: 1. Manufacturer's standard baked -enamel paint for the following: a. Exterior of cabinet door, except for those surfaces indicated to receive another finish. Color to match adjacent portion. b. Interior of cabinet and door. 2. Steel: Factory primed with manufacturer's standard, lead- and chromate -free, universal primer, for field painting. 2.5 MOUNTING BRACKETS Delete this Article if mounting brackets separate from fire -protection cabinets are not required. A. Manufacturers: 1. Amerex Corporation. 2. Ansul Incorporated. 3. Badger Fire Protection. 4. Buckeye Fire Equipment Company. 5. Fire End & Croker Corporation. 6. General Fire Extinguisher Corporation. 7. JL Industries, Inc. FIRE EXTINGUISHERS 10505 -4 Copyright 2004 Gensler Gensler October 7, 2005 02.3101.000 Issue for Permit, Pricing & Construction 8. Larsen's Manufacturing Company. 9. Potter Roemer; Div. of Smith Industries, Inc. Adam Plaza B. Mounting Brackets: Manufacturer's standard galvanized steel, designed to secure fire extinguisher to wall or structure, of sizes required for types and capacities of fire extinguishers indicated, with plated or baked -enamel finish. 1. Color: Black. C. Identification: Lettering complying with authorities having jurisdiction for letter style, size, spacing, and location. Locate as indicated by Architect. 1. Identify bracket -mounted fire extinguishers with the words "FIRE EXTINGUISHER" in red letter decals applied to mounting surface. a. Orientation: Horizontal 2.6 FABRICATION A. Fire -Protection Cabinets: Provide manufacturer's standard box (tub), with trim, frame, door, and hardware to suit cabinet type, trim style, and door style indicated. Weld joints and grind smooth. 1. Construct fire -rated cabinets with double walls fabricated from 0.0428411ch- (1.1-mrn-) thick, cold -rolled steel sheet lined with minimum 5/8-inch- (16-nrm-) thick, fire -barrier material. Provide factory -drilled mounting holes. B. Cabinet Doors: Fabricate doors according to manufacturer's standards, from materials indicated and coordinated with cabinet types and trim styles selected. 1. Fabricate door frames with tubular stiles and rails and hollow -metal design, minimum 1 /2 inch (1 3 mm) thick. 2. Miter and weld perimeter door frames. C. Cabinet Trim: Fabricate cabinet trim in one piece with corners mitered, welded, and ground smooth. PART 3 - EXECUTION 3:1 INSTALLATION A. Examine walls and partitions for suitable framing depth and blocking where recessed cabinets will be installed. FIRE EXTINGUISHERS 10505 - 5 Copyright 2004 Gensler Gensler October 7, 2005 Adam Plaza 02.3101.000 Issue for Permit, Pricing & Construction B. Examine fire extinguishers for proper charging and tagging. Remove and replace damaged, defective, or undercharged units. C. Prepare recesses for recessed fire -protection cabinets as required by type and size of cabinet and trim style. D. Install fire -protection specialties in locations and at mounting heights indicated or, if not indicated, at heights acceptable to authorities having jurisdiction. E. Fire -Protection Cabinets: Fasten fire -protection cabinets to structure, square and plumb. 1. Unless otherwise indicated, provide recessed fire -protection cabinets. If wall thickness is not adequate for recessed cabinets, notify architect. 2. Provide inside latch and lock for break -glass panels. 3. Fasten mounting brackets to inside surface of fire -protection cabinets, square and plumb. F. Mounting Brackets: Fasten mounting brackets to surfaces, square and plumb, at locations indicated. G. Identification: Apply decals at locations indicated. H. Adjust fire -protection cabinet doors to operate easily without binding. Verify that integral locking devices operate properly. I. Replace fire -protection cabinets that have been damaged or have deteriorated beyond successful repair. END OF SECTION 10520 FIRE EXTINGUISHERS Copyright 2004 Gensler 10505 - 6 01/24/2006 12:46 FAX 9792686022 ■ �■ I" M"IsON CONSTRUCTION, L.P. MADISON CONSTRUCTION 1@ 0 0 1 / 0 0 2 MEMORANDUM DATE: January 24, 2006 TO: City of College Station Attn: Ben McCarty TELE: FAX: 979-764-3570 979-764-3496 FROM: Marq D. Synwolt TELE: FAX: 979-268-5520 979-268-6022 RE: Adam Plaza — Elevator "Lockout" for Unoccupied Floors. Pages Sent Including This Memo 02 MESSAGE: Ben, As we discussed, the elevators can be programmed so they will not open to an unoccupied floor (re: attached transmittal sheet from Schindler Elevator Corporation dated 1/23/06). We will coordinate with Lyda Swinerton Builders and Schindler Elevator Corporation to insure the appropriate programming takes place. Please call me at 979-268-5520 or 979-412-1017 if you need further information. Thank you, CC. Jody Quimby — AC Mike Jones — MC Corby Rodgers — MC IF THERE IS ANY PROBLEM WITH THIS TRANSMISSION PLEASE CONTACT 979-268-6520. P. 0. BOX 3787 - BRYAN, TEXAS 77805-3787 O1/24/2006 12:46 FAX 9792686022 MADISON CONSTRUCTION fM 002/002 SCHINDLER ELEVATOR CORPORATION FACSIMILE TRANSMITTAL SHRRT t'O: k�ROM: Matk Jew Burke COMPANY: DAM O Madison Canstxwadon 1/23/2006 PAX NUhQHP, TOTAL NO. OF PA rUS INGLUI)LNG COVPR! 979-269-6022 P140NU NIJNMHR; SANDER'S REFRFt iNCU NUMBER: 979-26&SMO RIP., PROJECP: Adam Plaza 0 URGENT R REVIEW C3 PLkSASE COJKMXNT 0 PLEASE REPLY 0 PLEASE PRCYCLU NGTWCOMMANTB, Kuk- Per gut dlscusdon, the elevator at Adorn Plus can be prog mmmed to lock out un oocapled &mm a4 diftcteeL If you brave any gtteWene please feel free to contact me. Thank You- Have a Nice Days t201 WRST LOOP NORTH, SUITIS 190 HOUSTON, TX 77055 jEtiAN-RURKi;@U8,8C14INDLI:R.COM 71g-670.2307-DIRECT LINE 71 s-dD2,007s-PAX Igo C�®i1p�0 965Z 'ON Wd :E 90OZ 'E 'uEr ion : 1st Floor Electrical Room Customer Panel : i DPI-EM / 1 Zone/Circuit Description Interfaces Load Type Actual Load (WNA) Max Load (WNA) BRKR Size" Phase Eight Poles Incandescent 1920 1920 20A-1P A Fluor. Downlights Fluor. Non -Dim 900 1920 20A-1 P B Downlights 2nd Floor Incandescent 9001 1920 20A-1P C Wallwashers Incandescent 1400 1920 20A-1 P A Downlights 10A CHOKE Incandescent 500 960 10A-1P B Entry Downlights Incandescent 300 1920 20A-1P C Sconces Incandescent 1600 1920 20A-1P A Sconces Incandescent 1600 192020A-1P B 2nd Floor Downlights Switched 600 1920 20A-1P C Cove Fluor. 3Wire 1200 1920 20A-1P A Incandescent 0 1920 20A-1P B Incandescent 0 1920 20A-1 P C 10920 (7, 120/208V, 3 Phase, 4 Wire Main Lugs Only Dimming Panel containing 1 20A- 1Pole branch breaker rated at 10,000AIC for each of the 12 dimming circuits. Max Input feed = 80A CGP199 Panel contains 10A chokes Phase A 6120.00 Project Name First American Plaza Phase B 3000.00 Page Number 1 L4 Phase C 1800.00 Project Location Bryan, TX ,,+, ����0�® GP Panel Load Schedule Job Number 88347 Designed By TBW Date IJanuary 17, 2006 CGP24-1204ML-10120-CGP199 N/E Panel Add: Location : 10th Floor Electrical Room Customer Panel : DP10=EM l rea/Room Customer Circuit Customer Zone Lutron Circuit Lutron Zone Zone/Circuit Description Interfaces Load Type Actual Load (WNA) Max Load (WNA) BRKR Size Phase Mr. Adam' Office 1072 —� Al 1 1 Desk Accent Incandescent 375 1920 2OA-1P A Mr. Adam' Office 1072 ti� A6 6 2 Sconces Incandescent 400 1920 20A-1 P B Mr. Atkinson's Office 1060 AA-1 1 3 Desk Accent Incandescent 750 1920 20A-1 P C Executive Waiting 1067 .�! EXW3 3 4 Downlights 10A-CHOKE Incandescent 300 960 10A-1P A Executive Conference 1064 -� EXC6 6 5 Sconces Incandescent 400 1920 20A-1P B Dining 1054 D2 2 6 Sconces Incandescent 600 1920 20A-1P C Spare BB1 7 Spare Incandescent 0 192020A-1P A Spare BA1 8 Spare Incandescent 0 1920 20A-1P B Vkinson Bathrm 1063 ,�• AABR2 2 9 Sconces Incandescent 400 1920 20A-1 P C Cinema Room 1079 -1% Cf1 1 10 Art Accents Incandescent 1700 1920 20A-1P A Cinema Room 1079 -:�Ib Cl2.3 2 11 Cove 10A-CHOKE Incandescent 800 960 10A-1P B Boardroom 1042 BR3 3 12 Sconces Incandescent 1200 1920 20A-1P C Prefunction 1043 /! PF1 1 13 Sconces Incandescent 800 1920 20A-1 P A Coffee Bar 1007 COF1 1 14 Coffee Pendant Incandescent 200 1920 20A-1P B Corridor 10007 c / j . CR1.1 1 15 Art Accents Incandescent 1200 1920 20A-1 P C Corridor 1000 �� CR3 3 16 Downlights Incandescent 200 1920 20A-1P A Reception 10th Floor R3 3 17 Lamps @ Reception Incandescent 200 1920 20A-1P B Reception 10th Floor -j R5 5 18 Walfwashers Incandescent 1080 192020A-1P C Reception 9th Floor ---3, R10 10 19 Sconces 9th floor Incandescent 1600 1920 20A-1P A aiting Room 10th Floor --vw WR3.1 3 20 Downlights 10A-CHOKE Incandescent 600 960 10A-1P B aiting Room 10th Floor y WR3.2 3 21 Downlights 10A-CHOKE Incandescent 600 960 10A-1P C Mr. Adam' Bathrm 1066,68-69 JV ABR1 1 22 Downlights Incandescent 100 1920 20A-1P A Shared Conference 1024 —V SC4 4 23 Waffwashers Incandescent 1400 1920 20A-1P B SPARE 24 Incandescent 0 1920 20A-1P C 14905 'Suggested N/E circuits, ' , e subject to change. 4�1 M4► 120/208V, 3 Phase, 4 Wire Main Lugs Only Dimming Panel containing 1 20A- 1Pole branch breaker rated at 10,000AIC for each of the 24 dimming circuits. Max input feed = 175A CGP199 Panel contains 10A chokes Phase A 5075.00 Project Name First American Plaza Phase B 4000.00 Page Number 101 Phase C 5830.00 Project Location Bryan, TX III IIf LTTRON® GP Panel Load Schedule Job Number 88347 Designed By Tsw Date JJanuary 17, 2006 CGP20-1204ML-10/20-CGP199 Panel Add: Location : 1st Floor Electrical Room Customer Panel : DP1-1 rea/Room Customer Circuit Customer Zone Lutron Circuit Lutron Zone Zone/Circuit Description Interfaces Load Type Actual Load (WNA) Max Load (WNA) BRKR Size Phase Cafeteria 1st Floor C2.1 2 1 Center Cove Fluor. 3Wire 1200 1920 20A-1P A Cafeteria 1st Floor C2.2 2 2 Center Cove Fluor. 3Wire 1200 1920 20A-1P B Cafeteria 1st Floor C3 3 3 New Center Cove Neon/Cold Cathode 5001 1920 20A-1 P C Cafeteria 1st Floor C4.1 4 4 Sconces Incandescent 1200 1920 20A-1P A Cafeteria 1st Floor C4.2 4 5 Sconces Incandescent 1200 1920 20A-1P B Cafeteria 1st Floor C5 5 6 FL Cove @ Beverage Cntr Fluor. Non -Dim 250 1920 20A-1P C Spare C5.2 7 Incandescent 0 1920 20A-1 P A Spare C6 8 Incandescent 0 1920 20A-1P B e C6.2 9 Incandescent 0 1920 20A-1P C Cafeteria 1st Floor C7.1 7 10 Pendants Table Incandescent 1200 1920 20A-1P A Cafeteria 1st Floor C7.2 7 11 Pendants Table Incandescent .1200 1920 20A-1P B Cafeteria 1st Floor C8 8 12 Large Sconces Incandescent 1800 1920 20A-1P C Cafeteria 1st Floor C9.1 9 13 General Downlights 10A-CHOKE Incandescent 600 960 10A-1P A Cafeteria 1st Floor C9.2 9 14 General Downlights 10A-CHOKE Incandescent 800 960 10A-1P B Cafeteria 1st Floor C9.3 9 15 General Downlights 10A-CHOKE Incandescent 600 960 10A-1P C Cafeteria 1st Floor C9.4 9 16 General Downlights 10A-CHOKE Incandescent 500 960 10A-1P A Cafeteria 1st Floor C11 11 17 FL 1x4 Serving Switched 500 1920 20A-1P B Expandable 18 Incandescent 0 1920 20A-1P C Expandable 19 Incandescent 0 1920 20A-1 P A Expandable 20 Incandescent 0 1920 20A-1P B 12750 120/208V, 3 Phase, 4 Wire Main Lugs Only Dimming Panel containing 1 20A- 1Pole branch breaker rated at 10,000AIC for each of the 20 dimming circuits. Max input feed = 150A. CGP199 Panel contains 10A chokes. Phase A 4700.00 Project Name First American Plaza Phase B 4900.00 Page Number 1 L1 Phase C 3150.00 Project Location Bryan, TX �j�P LUTI�ON®8347 GP Panel Load Schedule Job Number Designed By TBW Date IJanuary 17, 2006 CGP24-1204ML-10/20-CGP199 Panel Add: Location : 1st Floor Electrical Room Customer Panel : :DPi-2 rea/Room Customer Circuit Customer Zone Lutron Circuit Lutron Zone Zone/Circuit Description Interfaces Load Type Actual Load (WNA) Max Load (W/VA) BRKR Size Phase Bank Lobby 1st Floor B4.1 4 1 Sconces Incandescent 1500 1920 20A-1P A Bank Lobby 1st Floor B4.2 4 2 Sconces Incandescent 600 1920 20A-1P B Bank Lobby 1st Floor B5 5 3 Counter Incandescent 7501 1920 20A-1P C Bank Lobby 1st Floor B6 6 4 Counter under cabinet 10A-CHOKE Incandescent 9001 960 10A-1P A Bank Lobby 1st Floor B7 7 5 Floor Plugs Incandescent 800 1920 20A-1P B Spare B8 6 Incandescent 0 1920 20A-1P C Bank Lobby 1st Floor B10 10 7 Signage Wallwashers Incandescent 500 1920 20A-1P A Bank Lobby 1st Floor B11 11 8 Pendant Incandescent 600 1920 20A-1P B Lobby 1st Floor B12 12 9 Pendant Incandescent 400 1920 20A-1P C Bank Lobby 1st Floor B13 13 10 Waiting Wallwashers Incandescent 540 1920 20A-1P A Bank Lobby 1st Floor B15 15 11 Accents Incandescent 375 1920 20A-1P B Bank Lobby 1st Floor B16 16 12 Downlights 10A-CHOKE Incandescent 600 960 10A-1P C Entry/Lobby 1st Floor E1 1 13 Entry Wallwash Incandescent 400 1920 20A-1P A Entry/Lobby 1st Floor E3 3 14 Chandelier Incandescent 1200 1920 20A-1P B Entry/Lobby 1st Floor E4 4 15 Neon Cove Neon/Cold Cathode 800 1920 20A-1P C Entry/Lobby 1st Floor E6 6 16 Small Cove Neon/Cold Cathode 1000 1920 20A-1P A Entry/Lobby 1st Floor E7 7 17 Downlights Incandescent 300 1920 20A-1P B Entry/Lobby 1st Floor E13.1 13 18 Sconces Incandescent 1400 1920 20A-1P C Entry/Lobby 1st Floor E13.2 13 19 Sconces Incandescent 1400 1920 20A-1P A Entry/Lobby 1st Floor E13.3 13 20 Sconces Incandescent 1400 1920 20A-1P B Entry/Lobby 1st Floor E15 15 21 Mezzanine Cove Neon/Cold Cathode 800 1920 20A-1P C Expandable 22 Incandescent 0 192020A-1P A Expandable 23 Incandescent 0 1920 20A-1 P B 24 Incandescent 0 192020A-1P C VExandable 16265 120/208V, 3 Phase, 4 Wire Main Lugs Only Dimming Panel containing 1 20A- 1Pole branch breaker rated at 10,000AIC for each of the 24 dimming circuits. Max input feed = 175A. CGP199 Panel contains 10A chokes Phase A 6240.00 Project Name First American Plaza Phase B 5275.00 Page Number 1 L2 Phase C 4750.00 Project Location Bryan, TX LUTRON® GP Panel Load Schedule Job Number 88347 Designed By TBW Date JJanuary 17, 2006 GP16-1204ML-20 Panel add: Location : 2nd Floor Electrical Room Customer Panel : DP2-1 rea/Room Customer Circuit Customer Zone Lutron Circuit Lutron Zone Zone/Circuit Description Interfaces Load Type Actual Load (WNA) Max Load (WNA) BRKR Size Phase Bank Lobby 2nd Floor 81.1 1 1 Cove 2nd Floor Neon/Cold Cathode 400 1920 20A-1 P A Bank Lobby 2nd Floor B1.2 1 2 Cove 2nd Floor Neon/Cold Cathode 400 1920 20A-lP B Bank Lobby 2nd Floor 61.3 1 3 Cove 2nd Floor Neon/Cold Cathode 400 1920 20A-1 P C Bank Lobby 2nd Floor 131.4 1 4 Cove 2nd Floor Neon/Cold Cathode 400 1920 20A-lP A Bank Lobby 2nd Floor B1.5 1 5 Cove 2nd Floor Neon/Cold Cathode 400 1920 20A-1P B Bank Lobby 2nd Floor B1.6 1 6 Cove 2nd Floor Neon/Cold Cathode 400 1920 20A-1 P C Bank Lobby 2nd Floor B2.2 2 7 Downlights 2nd Floor Switched 900 1920 20A-lP A Bank Lobby 2nd Floor B3.1 3 8 Chandelier Large Incandescent 1920 1920 20A-1P B Lobby 2nd Floor B3.2 3 9 Chandelier Small Incandescent 1200 1920 20A-1 P C ntry Lobby 2nd Floor E8 8 10 2nd Floor Cove Large Neon/Cold Cathode 1000 1920 20A-1 P A Entry Lobby 2nd Floor E9 9 11 2nd Floor Cove Small Neon/Cold Cathode 600 1920 20A-1 P B Entry Lobby 2nd Floor E11 11 12 Chandelier Large Incandescent 1200 1920 20A-1 P C Entry Lobby 2nd Floor E12 12 13 Chandelier Small Incandescent 800 1920 20A-1P A Entry Lobby 2nd Floor E14 14 14 Downlights 2nd Floor Switched 300 1920 20A-1 P B SPARE 15 Incandescent 0 1920 20A-1P C SPARE 16 Incandescent 0 1920 20A-1 P A 0 0 0 0 10320 120/208V, 3 Phase, 4 Wire Main Lugs Only Dimming Panel containing 1 20A- Vole branch breaker rated at 10,000AIC for each of the 16 dimming circuits. Max input feed = 125A Phase A 3500.00 Project Name First American Plaza phase B 3620.00 Page Number 1 L3 Phase C 3200.00 Project Location Bryan, TX -,,,,� LUTF�aN® GP Panel Load Schedule Job Number 88347 Designed By TBW Date 1January 17, 2006 CGP24-1204ML-10/20-CGP199 Panel Add: Location : 10th Floor Electrical Room Customer Panel : DP10-1 rea/Room Customer Circuit Customer Zone Lutron Circuit Lutron Zone Zone/Circuit Description Interfaces Load Type Actual Load (WNA) Max Load (WNA) BRKR Size Phase Mr. Adam' Office 1072 A2 2 1 Table Accent Incandescent 375 1920 20A-1 P A Mr. Adam' Office 1072 A3 3 2 Art Accent Incandescent 750 1920 20A-1 P B Mr. Adam' Office 1072 A4 4 3 Art Accent Incandescent 11501 1920 20A-1 P C Mr. Adam' Office 1072 A5.1 5 4 Bookcase 10A CHOKE Incandescent 600 960 10A-1 P A Mr. Adam' Office 1072 A5.2 5 5 Bookcase 10A CHOKE Incandescent 600 960 10A-1 P B Mr. Adam' Office 1072 A5.3 5 6 Bookcase 10A CHOKE Incandescent 800 960 10A-1P C Spare A5.4 7 10ACHOKE Incandescent 0 96010A-1P A Mr. Adam' Office 1072 A5.5 5 8 Bookcase 10A CHOKE Incandescent 800 960 10A-1 P B I' ,dam' Office 1072 A5.6 5 9 Bookcase 10A CHOKE Incandescent 600 960 10A-1 P C Mr. Adam' Office 1072 A5.7 5 10 Bookcase 10A CHOKE Incandescent 600 960 10A-1 P A Mr. Adam' Office 1072 A7 7 11 Receptacle Incandescent 200 1920 20A-1P B Mr. Adam' Office 1072 A8 8 12 Receptacle Incandescent 200 1920 20A-lP C Mr. Adam' Office 1072 A9 9 13 Cove 10A CHOKE Neon/Cold Cathode 600 960 10A-1P A Mr. Adam' Office 1072 A10 10 14 Cove 10A CHOKE Neon/Cold Cathode 600 960 10A-1 P B Mr. Adam' Office 1072 A11 11 15 Picture Light Incandescent 300 1920 20A-1P C Mr. Atkinson's Office 1060 AA2 2 16 Table Accent Incandescent 300 1920 20A-1P A Mr. Atkinson's Office 1060 AA3 3 17 Downlight 10A CHOKE Incandescent 150 960 10A-1 P B Mr. Atkinson's Office 1060 AA4 4 18 Par Cove Incandescent 300 1920 20A-1 P C Mr. Atkinson's Office 1060 AA5.1 5 19 Under Cabinet 10A CHOKE Incandescent 800 960 10A-1P A Mr. Atkinson's Office 1060 AA6 6 20 Pendant Incandescent 300 1920 20A-1 P B Mr. Atkinson's Office 1060 AA5.2 5 21 Under Cabinet 10A CHOKE Incandescent 800 960 10A-1 P C Mr. Atkinson's Office 1060 AA7 7 22 Art Accent Incandescent 375 1920 20A-1 P A Mr. Atkinson's Office 1061 AA8 8 23 Picture Light Incandescent 600 1920 20A-lP B SPARE 24 Incandescent i01 1920 20A-1P C 11800 120/208V, 3 Phase, 4 Wire Main Lugs Only Dimming Panel containing 1 20A- 1Pole branch breaker rated at 10,000AIC for each of the 24 dimming circuits. Max input feed = 175A. CGP199 Panel contains 10A chokes. Phase A 3650.00 Project Name First American Plaza Phase B 4000.00 Page Number 1 L5 Phase C 4150.00 Project Location Bryan, TX t1�� LVT -- ON® GP Panel Load Schedule Job Number 88347 gned By Designed T BW BW Date January 17, 2006 CGP24-1204ML-10/20-CGP199 Panel Add: Location : 10th Floor Electrical Room Customer Panel : DP10-2 rea/Room Customer Circuit Customer Zone Lutron Circuit Lutron Zone Zone/Circuit Description Interfaces Load Type Actual Load (WNA) Max Load (WNA) BRKR Size Phase Executive Waiting 1067 EXW1 1 1 Accent Incandescent 600 1920 20A-1P A Executive Waiting 1067 EXW2 2 2 Art Incandescent 600 1920 20A-1P B Executive Waiting 1067 EXW4 4 3 Reception Incandescent 2001 1920 20A-1P C Executive Conference 1064 EXC1 1 4 Wallwash Incandescent 500 1920 20A-1P A Executive Conference 1064 EXC2 2 5 Wallwash Incandescent 500 1920 20A-1P B Executive Conference 1064 EXC3 3 6 Table Accent Incandescent 800 1920 20A-1P C Executive Conference 1064 EXC4 4 7 Pendant Incandescent 300 1920 20A-1P A Executive Conference 1064 EXC5 5 8 Art Incandescent 300 1920 20A-1 P B ;utive Conference 1064 EXC7 7 9 Cove Neon/Cold Cathode 500j 1920 20A-1P C Dining 1054 D1 1 10 Pendant Incandescent 1920 1920 20A-1P A SPARE D2em 2 11 Incandescent 0 1920 20A-1P B Dining 1054 D3.1 3 12 Wallwash Incandescent 1200 1920 20A-1P C Dining 1054 D3.2 3 13 Wallwash Incandescent 900 1920 20A-1P A Dining 1054 D4 4 14 Table Accent Incandescent 600 1920 20A-1 P B Dining 1054 D5 5 15 Receptacles Incandescent 800 1920 20A-1P C Dining 1054 D6.1 6 16 General Downlights 10A CHOKE Incandescent 600 960 10A-1P A Dining 1054 D6.2 7 17 General Downlights 10A CHOKE Incandescent 450 960 10A-1P B Bar 1065 BB2 2 18 Lower Cabinet 10A CHOKE Incandescent 480 960 10A-1 P C Bar 1045 BA2 2 19 Lower Cabinet 10A CHOKE Incandescent 750 960 10A-1P A Mr. Atkinson's Bthrm 1063 AABR1 1 20 Downlight Incandescent 100 1920 20A-1P B Bar 1065 B61 21 Upper Cabinet 10A CHOKE Incandescent 560 960 10A-1 P C Bar 1045 BA1 22 Upper Cabinet 10A CHOKE Incandescent 350 960 10A-1P A Mr. Atkinson's Bthrm 1063 AABR3 23 Pendant Incandescent 300 1920 20A-1P B SPARE 24 Incandescent 0 1920 20A-1 P C 13310 120/208V, 3 Phase, 4 Wire Main Lugs Only Dimming Panel containing 1 20A- 1Pole branch breaker rated at 10,000AIC for each of the 24 dimming circuits. Max input feed = 175A CGP199 Panel contains 10A filter chokes Phase A 5920.00 Project Name First American Plaza Phase B 2850.00 Page Number 1 L6 Phase C 4540.00 Project Location Bryan, TX :V.0 L"TRON. GP Panel Load Schedule Job Number 88347 Designed By TBW TBW Date IJanuary 17, 2006 CGP20-1204ML-10/20-CGP199 Panel Add: Location : 10th Floor Electrical Room Customer Panel : DP10-3 Area/Room Customer Circuit Customer Zone Lutron Circuit Lutron Zone Zone/Circuit Description Interfaces Load Type Actual Load (WNA) Max Load (WNA) BRKR Size Phase Cinema Room 1079 10th FL Cl2.1 2 1 Cove 10A CHOKE Incandescent 800 960 10A-1P A Cinema Room 1079 10th FL Cl2.2 2 2 Cove 10A CHOKE Incandescent 800 960 10A-1P B Cinema Room 1079 10th FL Cl2.4 2 3 Cove 10A CHOKE Incandescent 8001 960 10A-1 P C Cinema Room 1079 10th FL Cl2.5 2 4 Cove 10A CHOKE Incandescent 800 960 10A-1P A Cinema Room 1079 10th FL Cl2.6 2 5 Cove 10A CHOKE Incandescent 800 960 10A-1P B Cinema Room 1079 10th FL Cl2.7 2 6 Cove 10A CHOKE Incandescent 800 960 10A-1P C Cinema Room 1079 10th FL Cl2.8 2 7 Cove 10A CHOKE Incandescent 800 960 10A-1P A Cinema Room 1079 10th FL C12.9 2 8 Cove 10ACHOKE Incandescent 800 960 10A-1P B i' na Room 1079 10th FL C12.10 2 9 Cove 10A CHOKE Incandescent 800 960 10A-1 P C Cinema Room 1079 10th FL Cl2.11 2 10 Cove 10A CHOKE Incandescent 800 960 10A-1P A Cinema Room 1079 10th FL Cl2.12 2 11 Cove 10A CHOKE Incandescent 800 960 10A-1P B Cinema Room 1079 10th FL Cl2.13 2 12 Cove 10A CHOKE Incandescent 800 960 10A-1P C Cinema Room 1079 10th FL C12.14 2 13 Cove 10A CHOKE Neon/Cold Cathode 800 960 10A-1 P A Cinema Room 1079 10th FL Cl2.15 2 14 Cove 10A CHOKE Neon/Cold Cathode 800 960 10A-1 P B Cinema Room 1079 10th FL Cl2.16 2 15 Cove 10A CHOKE Incandescent 800 960 10A-1P C Cinema Room 1079 10th FL Cl2.17 2 16 Cove 10A CHOKE Incandescent 800 960 10A-1P A Cinema Room 1079 10th FL Cl2.18 2 17 Cove 10A CHOKE Incandescent 800 960 10A-1P B Cinema Room 1079 10th FL CI13 3 18 Par Cove Incandescent 900 1920 20A-1 P C SPARE 19 Incandescent 0 1920 20A-1P A SPARE 20 Incandescent 0 1920 20A-1P B 1 14500 120/208V, 3 Phase, 4 Wire Main Lugs Only Dimming Panel containing 1 20A- 1Pole branch breaker rated at 10,000AIC for each of the 20 dimming circuits. Max input feed = 150A CGP199 Panel contains 10A chokes Phase A 0 Project Name First American Plaza Phase B 0 Page Number 1 L7 Phase C 0 Project Location Bryan, TX 50 ��+�� LVTRQN® GP Panel Load Schedule Job 88347 Designed By Designed By TBW TBW Date January 17, 2006 GP24-1204ML-20 Panel Add: Location : 10th Floor Electrical Room Customer Panel : DP10-4 rea/Room Customer Circuit Customer Zone Lutron Circuit Lutron Zone Zone/Circuit Description Interfaces Load Type Actual Load (WNA) Max Load (WNA) BRKR Size Phase Boardroom 1042 BR1 1 1 Pendant Incandescent 1920 1920 20A-1P A Boardroom 1042 BR2 2 2 Table Accent Incandescent 1920 1920 20A-1 P B Boardroom 1042 BR4 4 3 Art Accents Incandescent 300 192020A-1P C Boardroom 1042 BR5 5 4 Cove Neon/Cold Cathode 575 1920 20A-1 P A Prefunction 1043 PF2 2 5 Door Downs Incandescent 600 1920 20A-1P B Prefunction 1043 PF3 3 6 Accent Incandescent 475 1920 20A-1P C Prefunction 1043 PF4 4 7 Table Incandescent 780 1920 20A-1P A Prefunction 1043 PF5 5 8 Art Accents Incandescent 960 1920 20A-1 P B dor 1000 10th FL CR1.2 1 9 Art Accents Incandescent 1800 1920 20A-1 P C Corridor 1000 10th FL CR2.1 2 10 Cove Neon/Cold Cathode 800 1920 20A-1 P A Corridor 1000 10th FL CR2.2 2 11 Cove Neon/Cold Cathode 800 1920 20A-1 P B Corridor 1000 10th FL CR2.3 2 12 Cove Neon/Cold Cathode 800 1920 20A-1 P C Corridor 1000 10th FL CR2.4 2 13 Cove Neon/Cold Cathode 800 1920 20A-1 P A Corridor 1000 10th FL CR2.5 2 14 Cove Neon/Cold Cathode 800 1920 20A-1 P B Corridor 1000 10th FL CR2.6 2 15 Cove Neon/Cold Cathode 800 1920 20A-1 P C Corridor 1000 10th FL CR4 4 16 Down Vestibule Incandescent 100 1920 20A-1P A Corridor 1000 10th FL CR5 5 17 Wallwashers Incandescent 800 1920 20A-1P B Corridor 1000 10th FL CR6 6 18 Art Accents Incandescent 400 1920 20A-1 P C Corridor 1000 10th FL CR7 7 19 Sconces Incandescent 800 1920 20A-1P A Corridor 1000 10th FL CR8 8 20 Art Accents Incandescent 375 1920 20A-1 P B Corridor 1000 10th FL CR9 8 21 Cove Neon/Cold Cathode 300 1920 20A-1 P C Corridor 1000 10th FL CR10 2 22 Vestibule Downlights Fluor. 3Wire 128 1920 20A-1 P A Corridor 1000 10th FL CR11 3 23 Pendant Incandescent 200 1920 20A-1P B SPARE 24 Incandescent 0 1920 20A-1P C 17233 120/208V, 3 Phase, 4 Wire Main Lugs Only Dimming Panel containing 1 20A- 1Pole branch breaker rated at 10,000AIC for each of the 24 dimming circuits. Max input feed = 175A Phase A 5903.00 Project Name First American Plaza phase B 6455.00 Page Number 1 L8 Phase C 4875.00 Project Location Bryan, TX ����= LVTRQN® GP Panel Load Schedule Job Number 88347 Designed By TBW BW Date JJanuary 17, 2006 CGP24-1204ML-10/20-CGP199 Panel Add: Location : 10th Floor Electrical Room Customer Panel : DP10-5 Area/Room Customer Circuit Customer Zone Lutron Circuit Lutron Zone Zone/Circuit Description Interfaces Load Type Actual Load (W/VA) Max Load (W/VA) BRKR Size Phase Reception 10th R1.1 1 1 Large Pendant Over Stairs Incandescent 1920 1920 20A-1 P A Reception 10th R1.2 1 2 Large Pendant Over Stairs Incandescent 1920 1920 20A-1P B Reception 10th R1.3 1 3 Large Pendant Over Stairs Incandescent 19201 1920 20A-1 P C Reception 10th R1.4 1 4 Large Pendant Over Stairs Incandescent 1920 1920 20A-1P A Reception 10th R2 2 5 Under Counter @ Recptn Incandescent 600 1920 20A-1 P B Reception 10th R4.1 4 6 Vaulted Ceiling Cove Fluor. 3Wire 1080 1920 20A-1P C Reception 10th R4.2 4 7 Vaulted Ceiling Cove Fluor. 3Wire 1080 1920 20A-1P A Reception 10th R6 6 8 Outlets Incandescent 800 1920 20A-1P B ption 9th R7.1 7 9 Type J Vestibule 10th 10A Choke Incandescent 9601 960 10A-1P C Spare R7.2 10 Incandescent 0 1920 20A-1P A Reception 9th R8 8 11 Adjustables @ Elevators Incandescent 300 1920 20A-1P B Reception 9th R9 9 12 Art Accents 9th Incandescent 1920 1920 20A-1 P C Reception 9th R11 11 13 Elevator Cove 9th 10th Neon/Cold Cathode 500 1920 20A-1 P A Reception 9th R12.1 12 14 Downlights 9th Floor 10A Choke Incandescent 750 960 10A-1P B Reception 9th R12.2 12 15 Downlights 9th Floor 10A Choke Incandescent 750 960 10A-1P C Reception 9th R13 13 16 Sconces 9th Floor Incandescent 800 1920 20A-1P A Reception 9th R14 14 17 Desk Accents 9th Floor Incandescent 850 1920 20A-1P B Reception 9th R15 15 18 Cove 9th Floor 10A Choke Incandescent 400 960 10A-1P C Coffee Bar 1007 COF2 2 19 Under/Above Cabinet Switched 300 1920 20A-1P A Coffee Bar 1007 COF3 3 20 Downlights/Wallwash 10A Choke Incandescent 650j 1920 20A-1P B SPARE 21 Incandescent 0 1920 20A-1P C SPARE 22 Incandescent 0 1920 20A-1P A SPARE 23 Incandescent 0 1920 20A-1P B SPARE 24 Incandescent 0 1920 2OA-1P C 19420 V, 3 Phase, 4 Wire Main Lugs Only Dimming Panel containing 1 20A- ranch breaker rated at 10,000AIC for each ofthe 24 dimming circuits. ut feed = 175A CGP199 panel contains 10A filter chokes Phase A 0 Project Name First American Plaza Phase B 0 Page Number 1L9 Phase C 0 Project Location Bryan, TX ,AI% LUTRON. �,,,` II GP Panel Load Schedule Job Number 88347 Designed By TBW TBW Date January 17, 2006 CGP20-1204ML-10/20-CGP199 Panel Add: Location : 10th Floor Electrical Room Customer Panel : DP10-6 rea/Room Customer Circuit Customer Zone Lutron Circuit Lutron Zone Zone/Circuit Description Interfaces Load Type Actual Load (W/VA) Max Load (WNA) BRKR Size Phase Waiting Room 10th Floor WR1 1 1 Wallwashers Incandescent 800 1920 20A-1P A Waiting Room 10th Floor WR2 2 2 Art Accents Incandescent 600 1920 20A-1 P B Waiting Room 10th Floor WR4.1 4 3 Under Cabinet 10A choke Incandescent 640 960 10A-1 P C Waiting Room 10th Floor WR5 5 4 Receptacles Incandescent 800 1920 20A-1P A Waiting Room 10th Floor WR6 6 5 Art Accents Incandescent 300 1920 20A-1 P B Waiting Room 10th Floor WR4.2 4 6 Under Cabinet 10A choke Incandescent 640 960 10A-1P C Waiting Room 10th Floor WR4.3 4 7 Under Cabinet 10A choke Incandescent 640 960 10A-1 P A Waiting Room 10th Floor WR4.4 4 8 Under Cabinet 10A choke Incandescent 640 960 10A-1 P B 'iE 5 9 Incandescent 0 1920 20A-1P C SPARE 6 10 Incandescent 0 1920 20A-1P A Mr. Adam' Bathrm 1066,68-69 ABR2 2 11 Cove Neon/Cold Cathode 150 1920 20A-1P B Mr. Adam' Bathrm 1066,68-69 ABR3 3 12 Art Accents Incandescent 150 1920 20A-1 P C Mr. Adam' Bathrm 1066,68-69 ABR4 4 13 Sconces Incandescent 800 1920 20A-1P A Mr. Adam' Bathrm 1066,68-69 ABR5 5 14 Pendant Incandescent 300 1920 20A-1P B Mr. Adam' Bathrm 1066,68-69 ABR6 6 15 Par Cove Incandescent 1000 1920 20A-1 P C Shared Conference 1024 SC1 16 Incandescent 300 1920 20A-1P A Shared Conference 1025 SC2 17 Incandescent 225 1920 20A-1P B Shared Conference 1026 SC3 18 Incandescent 200 1920 20A-1P C SPARE 19 Incandescent 0 1920 20A-1 P A SPARE 20 Incandescent 0 1920 20A-1P B 8185 120/208V, 3 Phase, 4 Wire Main Lugs Only Dimming Panel containing 1 20A- 1Pole branch breaker rated at 10,000AIC for each of the 20 dimming circuits. Max input feed = 150A CGP199=Panel contains 10A chokes Phase A 3340.00 Project Name First American Plaza Phase B 2215.00 Page Number 1 L10 Phase C 2630.00 Project Location Bryan, TX Vhr' LVTRaN®88347 GP Panel Load Schedule Job Number Designed By ew TBW Date January 17, 2006 Transmittal Gensler to Attention City of College Station - Planning & Deve. Chris Haver 979.764.6254 Address 1101 Texas Avenue South City State zip College Station Texas 77840 Protect Project Number Flie Adam Plaza - Application #05-3934 02.3101.000 3c Subject Level 10 drinking fountains and door hardware Prepared by This Is page Date Corey Credeur 713.356.1390 1 of 1 03.13.07 For Your ❑ Approval and selection ® use ® Record ❑ Review / Comment ❑ Distribution ❑ Information Action Required ❑ Indicated on Item transmitted ❑ Comment and return to Hensler ® No action required ❑ Sign and return to this office ❑ See remarks below ❑ Other Delivered Via ❑ Messenger ❑ Two-0ay Express ❑ Pick-up ❑ Same Day Express ® Mail ® other. Email ❑ Next Day Express ❑ Hand carried Remarks The attached letters are record of our conversation earlier today. Quantity Description Dated Letter regarding door hardware 03.13.07 Letter regarding drinking fountains 03.13.07 Transmittal Copies To Enclosures: Delivered Via If enclosures are not as described, please advise Gensler immediately. Jody Quimby / The Adam Corporation Same Email Mike Jones / Madison Construction Same Email Pennzoil Place I:\02.3101.000\documentation\3_regulatory\3c\tt070313_ch.doc 700 Milam Street, Suite 400 Houston Texas 77002 Tel: 713.228.8050 TR_080705 Fax: 713.229.9343 Architecture, Design & Planning Worldwide Gensler March 13, 2007 Chris Haver City of College Station Development Services 1101 Texas Avenue South P.O. Box 9960 College Station, Texas 77842 RE: Adam Plaza .Application #05-3934 Dear Mr. Haver, This letter is to document some changes to the door hardware on the 10`h floor of Adam Plaza that were verbally approved in February 2007. The owner would like to put card readers on the three sets of double doors indicated on the attached drawing. One leaf will be active and have an electric hinge. The other leaf will be inactive with top and bottom flush bolts to hold the door in a fixed position so the active leaf can latch into it. To avoid confusion over which door was active or inactive, we agreed that the inactive leaf would not have a lever. Sincerely, Corey Credeur, AIA Associate Attachments: Sketch No. 1 — Level 10 Partial Plan cc: Jody Quimby/The Adam Corporation Mike Jones/Madison Construction Pennzoil Place 700 Milam Street Suite 400 Houston Texas 77002 Tel: 7t3. 2 28. 8050 Fax: 713. 229. 9343 �' Ilr�lll lI �;. ►: : III `i3 � IIII � , I � � �� �-. ` �C•7� . -�-, M >, / - --- 911 m - .,�:�: III ■LE MR. ADAM 1072 ■'II Architecture, Design 6- Planning Worldwide Gensler March 13, 2007 Chris Haver City of College Station Development Services 1101 Texas Avenue South P.O. Box 9960 College Station, Texas 77842 RE: Adam Plaza Application #05-3934 Dear Mr. Haver, This letter is to document our conversation earlier today regarding drinking fountains on the 10`h floor of Adam Plaza. The City of College Station will allow the removal of the public drinking fountains if a water dispenser is located in the coffee bar for the tenants of this floor. Sincerely, Corey Credeur, AIA Associate cc: Jody Quimby/The Adam Corporation Mike Jones/Madison Construction Pennzoil Place 700 Milam Street Suite 400 Houston Texas 77002 Tel: 713. 228. 8050 Fax: 713. 229. 9343 BU LDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: ---------------------------------------------------------------------------- (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 05-00003934 Date 1/27/06 Property Address . . . . . . 1 FIRST AMERICAN BLVD Property ID . . . . . . . . . 212200-0001-0010 R# . . . . . . . . . . . . . Tenant nbr, name . . . . . . LOBBY & OFFICES Application type description COMMERCIAL, OFFICES/BANKS/PROFESSION Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . GENERAL COMMERCIAL Application valuation . . . . 2556694 Owner Contractor ------------------------ ------------------------ MADISON CONSTRUCTION CORP MICHAEL R JONES 1640 BRIARCREST BRYAN TX 77802 (979) 268-5520 --- Structure Information 000 000 TENANT FINISHOUT AT ADAM PLAZA Construction Type . . . . . FIRE RESISTANT Occupancy Type . . . . . . BUSINESS Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB HEATED AREA 26486.00 INTERIOR WALL TYPE SHEETROCK SEWER TYPE PUBLIC TAZ 164.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit Fee . . . . 5774.00 Plan Check Fee .00 Issue Date . . . . 1/27/06 Valuation . . . . 2556694 Expiration Date . . 7/26/06 Qty Unit Charge Per Extension BASE FEE 1660.00 2057.00 2.0000 THOU BLDG, VAL 500001 & UP 4114.00 ---------------------------------------------------------------------------- Special Notes and Comments NOTE FROM WATER DEPT--REDUCED PRESSURE ASSEMBLY REQUIRED FOR CAR WASH, POSTMIX CARBONATER, AND HEATING/AC WITH DIRECT CONNECTION TO WATER SUPPLY AND LAWN IRRIGATION SYSTEMS. ALL DEVICES MUST BE TESTED UPON INSTALLATION BY CERTIFIED TESTER REGISTERED WITH THE CITY OF COLLEGE STATION PUBLIC UTILITIES DEPT. LAWN IRRIGATION MAY USE A PRESSURE VACCUM ------------------ ----- ---------------------------- --------------- BUILDING DEPT RE ESENTATIVE: i�--- APPLICANT: / �a BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 05-00003934 Date 1/27/06 ---------------------------------------------------------------------------- Special Notes and Comments BREAKER INSTALLED PER AWWA STANDARDS AND CITY'S ORD #2394. ALL DEVICES MUST BE INSTALLED PER AWWA AND CITY'S ORD#2394 PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Electrical conduit installation shall be installed per city specs and is the responsibility of the owner and/or contractor. Contact the electrical division at (979) 764- 6314 for more information. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS SUBMIT FIRE ALARM PLANS WITH PRODUCT DATA SHEETS - DESIGN AND INSTALL AS PER NFPA 72 NO WORK SHALL START UNTIL PLANS HAVE BEEN REVIEWED AND RETURNED PROVIDE FIRE EXTINGUISHERS) - VERIFY LOCATION AND PLACEMENT WITH THE FIRE MARSHALL'S OFFICE (MIN. 2A10BC) SUBMIT FIRE SPRINKLER PLANS AND CALCULATIONS FOR REVIEW NO WORK ON SPRINKLER SYSTEM SHALL BEGIN UNTIL PLANS HAVE BEEN REVIEW AND RETURNED. SPRINKLER SYSTEM CONTROLS AND WATER FLOW SWITCHES ARE REQUIRED TO BE MONITORED BY AN APPROVED MONITORING COMPANY. A COPY OF THE MONITORING CONTRACT SHALL BE SENT TO THE COLLEGE STATION FIRE DEPARTMENT, FIRE PREVENTION DIVISION. INTERIOR FINISH MATERIAL SHALL HAVE A CLASS A RATING REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT All outdoor lighting must be in compliance with Section 7.10, Outdoor lighting Standards of the City's Unified Development Ordinance THERE SHALL BE NO COMBUSTIBLE OR FLAMMABLE MATERIALS PLACED ON SITE, LOT OR SUBDIVISION WHERE WATERLINES AND FIRE HYDRANTS AS REQUIRED BY THE APPLICABLE SUBDIVISON REGULATIONS ARE NOT COMPLETED AND IN SERVICE AND WHERE ALL-WEATHER ACCESS FOR EMERGENCY VEHICLES DOES NOT EXIST TO WITHIN ONE HUNDRED FIFTY FEET (1501) OF THE MOST REMOTE PART OF THE STRUCTURE. (IFC section 501.4) ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BUILDING DEPT R R ENTAT APPLICANT: / BUILDING PERMIT CITY OF COLLEGE STATION , 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496' Page 3 Application Number . . . . . 05-00003934 Date 1/27/06 ---------------------------------------------------------------------------- Special Notes and Comments BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK CIRCUIT CR1.2 IN CORRIDOR 1000A, 1000B, AND 1000C OF THE TENTH FLOOR WILL BE ADDED TO THE EMERGENCY POWER PANEL DP10-EM. COMMERCIAL KITCHEN HOOD ON TENTH FLOOR REQUIRES THE INSTALLATION OF NONCOMBUSTIBLE MATERIALS FOR WALLS AND FINISHES WITHIN 18" OF HOOD AND COOKING AREA. Fee summary Charged ----------------- ---------- Permit Fee Total 5774.00 Plan Check Total .00 Grand Total 5774.00 Paid Credited Due 5774.00 .00 .00 .00 .00 .00 5774.00 .00 .00 ----------------- -------------------------------- ----------------- BUILDING DEPT P SENTATIV :/ APPLICANT: V1*4 CrIy oP CO=0S S A,n0N Pkttn,,*r 41.bJvtlofMMl StNiI[r ADDRESS/LOCATION: APPLICATION POR, SUILDINC KNIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE OOLLEGE STATION, TX 77840 (�Jti.fT.V010)��T04.3670 (970) 784.3498 FAX ��SM40V f1 r9 f_ Aryxf•v j earl &,Vck ' CEVAsi LOT. —I BLOCK1 SUgpIVISION Crescent Pointe 7� SECIPH 1USINES(OWNERNAMI Adam Development Properties,pH: 776-1111 CONTRACrOR/HOMEOWNCR:Xadi Sip_ Construction L P-PHokE: 268-5520 CONTRACTOR ADDRESS: 1640 ' Briarcrest) A Suite 125 Bryan, TX 77802 SLECTA10AN: ggBe Determined PLUMOER: To Be Determined IfVAv: TQ. BQ.. D�.tee mMj ed GOOD CENTS tResldentlai o I--.--��—. CLASS OIL WORK h ACCESS RYISTORAGE LOCATION R�-Roori MCsVIN.G SMELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION ° S�AB ONLY DUPLEX (Landscape Puns REMODELJRENOVATION" Required) SWIMMING POOLi QESCRIPTION OF WORK: �; aa .�ilQ._ 1 iish of Office Bui;lUincy� Y !ore area.and Tebh Floor Office STRUCTURE USE: ^Lobby. and Offices HOMEOWNER ASSMIATInN/AIRCHITEQTUAL OR DESIGN REVIEW 00MMITTC'E Al 'TF-XAS ACCE351811.I7Y STANDARD (TAB) PROJECT REGISTRATION# EASPRJ A6 VALUATION: $ TOTAL ARW 6 4 8 6 S F HEA • l�%oe of Labor and Meter a s PV13LICSEWER In Base Building U SEPTIMREATMENT SYSTEM [I SEWERTAP:In Base Building �3 WATERTWIn BAse Building size OTHERTAP:In ,B.azg Building Size TEUP PoL.E GARAOF. TYPE: In Base. Building SINGLE ED ATTACHED M 4 8 4 ARFH. 26486SF NUMBER OF BEDROOMS: �pL NUM8EROF BATHROOMS: ale m2 female publicy- 2 INMRIOR WALL. TYPE; In Gypsum Wall Assembly -private ExTERiOR WALL TYPE: I n ' l d i- _ FOUNDATION TYPE: In Bash Building ROOF TYPF_r DOUBLE TRIPLE; 4 ACH>wD CARPORT SIGNATURE OF APPLICANT: "If proposed work involves new coA�erc6i1a;R(c'14;)7n9-qt;rtinn nr f€aaads improvernenti oornmerdat property, building elevations are req�l read, aa�irag•epaeoaaraaa�aoa*r�aaaaeaaaaaosa4•aa♦ara+♦ Ofllulrs/V ev Only Flans Exainlner zon,Ing O'flloial OYtitlur�� t Gan. eximinq >a�aar�eeta.a4• Brits:, Ir8 Or NO From: "Marq Synwolt" <msynwolt@madison-construction.com> To: "Benjamin McCarty" <BMcCarty@cstx.gov> Date: 1/25/2006 12:59:38 PM Subject: Re: Adam Plaza - Permitting Ben, In response to your letter to Gensler dated January 24, 2006 we have confirmed the following with Bouyea and Associates / Lutron: 1!Circuit C-8�(wall sconces in the�D Wing Room, sheet LC00-01 B) will be added toiemergency panel DP1-EM7to`comply with section 1006.3 of the 2003 International'Building'Code;-= 2!Circuit Referenced C=1 on emergency panel DP1-EM will actually be designated as a spare; 3. Circuit'CR172 of=the�tenth floor corridor 1000A71000E and -1000C,(sheet LC00=10) will be added to the emergency panel DP10-EM/. --------- We hope that this information sufficiently addresses items 1,2 and 3 of your January 24, 2006 letter to Gensler. We have yet to receive clarification of items 4, 5 and 6 (Application # 05-3935 - Finish -out of office building garage) that you addressed on your January 24, 2006 letter to Gensler. Please let me know if you need further information or documentation. Thank You, Marq D. Synwolt Application #05-3932 (1st Floor Amenity Wing) ----- Original Message ----- From: "Benjamin McCarty" <BMcCarty@cstx.gov> To: <msynwolt@madison-construction.com> Sent: Tuesday, January 24, 2006 4:31 PM Subject: Adam Plaza >1 sent the attached letter to architect Bonny McLoud of Gensler. > Benjamin McCarty'00 > Commercial Plans Examiner > City of College Station > 1101 Texas Avenue > College Station, TX 77842 > 979.764.3570 > College Station. Heart of the Research Valley. 0 PROJECT f�dcv`^ 01 L" PLAN REVIEW NO O S- 31 3 Y rP Corn 4,•'e*- BUSINESS OCCUPANCY REQUIREMENTS "(7. 2000 International Building Code CODE SECTION ITEM O.K., COMMENT OR N/A Table 503 Building Height and Area O IC 504 Height Modifications N/A 505 Mezzanines 508.4 Special Unlimited Height 506 Area Modifications 302.3 Mixed Occupancy Separation 302.2 Accessory Use Areas pig 302.1.1 Incidental Use Areas p (� 411.3 Special Amusement Buildings - Automatic Fire Detection N/� 412.1 Air Traffic Control Towers 903 SPRINKLERS WHERE REQUIRED N/A OK 903.2.12.1 Basements > 1500 sq ft AIIA 903.2.12.3 Buildings Over 55 Feet in Height 01< 507.2, 507.3 Unlimited Area WIA Table 601 Note d Reduction of Hourly Ratings with Sprinklers O lc. 603.1(8) Partition Material Exception for Type I and Type II Construction D Table 1004.3.2.1 Exit Access Corridor Rating OK Table 803.4 Interior Finish Classification J@Mok< 907.2.2 Fire Alarms With Occupant Load of 500 or more N 0Tr- E 1004.2.4 Exit Access Travel Distance 0 1(1 903.3.1 Sprinkler Standard NFPA 13 IJflf € 905 STANDPIPES WHERE REQUIRED N/A 0 905.2 Standpipe Standard NFPA 14 905.3.1 Building With Floors 30 ft above Fire Department Vehicle Access 2000 Plan Review Forms CODE ITEM O.K., SECTION COMMENT OR N/A 905.3.2 Building With Story > 10,000 sq ft and > 200 ft travel to Fire 0 �. Department Vehicle Access 905.4 - 905.6 Hose Connection Location O /C 905.9 Valves Controlling Water Supply 6 [C 1001 EGRESS GENERAL 1003.2.3 Exit Capacity • Occupant O (4 Content 1003.2.2.7 Converging Exits OK 1004 Travel Distance & Arrangement of Exits Table 1004.2.1 Two Exits (Room or Tenant Space > 50 Occupants or travel > than 1004.2.5) 1004.2.5 Common Path of Travel 1004.2.2.1 Exit Separation (''/s Diagonal Dimension of Building) 1004.3.2.2 Minimum Width of Access Corridor 1003.3.3.1 Minimum Stair Width 1003.3.1.1 Minimum Exit Door Width Table 1005.2.2 Single Exit (One Story, 50 Occupants, and 75 ft Travel NIA Distance) Table 1005.2.2 Single Exit (Two Stories, 30 Occupants, and 75 ft Travel N/A Distance) 1007.1 Boiler, Incinerator or Furnace VIA 1007.2 Refrigeration Machinery N/� Rooms 1004.3.1.1 Aisle Width in Public Areas 1004.3.2.3 Dead End Corridor • 20 ft 1004.3.2 Exit Access Corridors O �� 1004.3.2.1 Corridor Rating Page 28 of 60 7 W c N z m Cn PROJECT PLAN REVIEW NO BUSINESS OCCUPANCY REQUIREMENTS 2000 International Building Code CODE SECTION ITEM C gNIA 1004.3.2.5 Exit Access Corridor Continuity 1004.2.3.1 Multiple Tenants A W/14 1005.3.2.5 Smokeproof Enclosures NO is 1003.2.2.8 Mezzanines A11A 1005.3.2 Enclosed Stairs OK 707.2(7) Floor Opening Permitted nic 1005.3.6 EXTERIOR EXITWAY STAIRS 1005.3.6.1 Height • 6 Stories • 75 ft 1004.2.4.2 Balcony Travel Distance Increase 1005.3.6.5 Fire Resistive Separation 1006.2.2 Adjacent Lot Lines 1003.3.3.5 STAIRWAY CONSTRUCTION N/A 0 �� 1003.3.3.5 Stairway Construction 1003.3.3.3.2 Closed/Open Risers 1005.3.2.2 Separation of Closets Below Stairways 1005.3.2.3 Stairway Identification for Stairs That Continue Below the Level of Discharge 1003.3.3.3 Stair Treads and Risers 1003.3.3.3.1 Uniform Treads and Risers 1003.3.3.7 Circular Stairs 1003.3.3.4 Landings 1003.3.3.11 Handrails 1003.3.3.2 Headroom 1003.3.3.12 Access to Roof 1005.3.5 Horizontal Exits 1006 Exit Discharge 1003.3.1.3.4 Access -Controlled Egress Doors N/a, CODE SECTION ITEM O.K., COMMENT OR N/A 1003.3.1.3.5 Security Grilles MIA 1003.3.1.8 Latching and Locking Hardware AK 1003.3.4 Ramps Jvl,4 1004.3.3 Balconies P//+ 1003.2.12 Guards u/A 1003.2.10 Exit Illumination and Signs OK 1005.3.2.4 Stairway Floor Number Signs OK 2000 Plan Review Forms Page 29 of 60 PROJECT PLAN REVIEW NO BUSINESS OCCUPANCY REQUIREMENTS 2000 International Building Code INTERIOR FINISH INTERIOR FINISH SECTION 803.4 UNSPRINKLERED° SPRINKLERED° REQUIRED ACTUAL O.K., REQUIRED ACTUAL O.K., COMMENT COMMENT OR NIA OR NIA Vertical Exits and Exit A B Passageways 8,b Exit Access Corridors B C and Other Exitways oK Rooms and Enclosed C C Spaces Floor Covering 0.22 watt/ 0.22 watt/ Corridors & Exits sq cm. sq cm. a. Class C interior finish materials shall be permitted for wainscotting or paneling of not more than 1,000 square feet of applied surface area in the grade lobby where applied directly to a noncombustible base or over furring strips applied to a noncombustible base and fireblocked as required by Section 803.3.1. b. In vertical exits of buildings less than three stories in height of other than Group 1-3, Class B interior finish for unsprinklered buildings and Class C interior finish for sprinklered buildings shall be permitted. C. Requirements for rooms and enclosed spaces shall be based upon spaces enclosed by partitions. Where a fire -resistance rating is required for structural elements, the enclosing partitions shall extend from the floor to the ceiling. Partitions that do not comply with this shall be considered enclosing spaces and the rooms or spaces on both sides shall be considered one. In determining the applicable requirements for rooms and enclosed spaces, the specific occupancy thereof shall be the governing factor regardless of the group classification of the building or structure. d. Applies when the vertical exits, exit passageways, exit access corridors or exitways, or rooms and spaces are protected by a sprinkler system installed in accordance with Section 903.3.1.1 or Section 903.3.1.2. 2000 Plan Review Forms Page 30 Of 60 040dr, City of College Station ' Page of Building Inspection Department PLANS EXAMINATION REPORT Address: First Date: I.. Jic/oS— fL./a f�/Asp Project Name: W hlt, --� Lore 14ru+J ✓S O/ K'c e. 'M +G✓,'or r,'n;5 `I v I4f- Drawing Number Code Ref. Number Questions or Comments 7 Fl�va�rS -'o uv► �%N�sG+Y� f oor5 /SLoc14 all 010«5f +o KPi+,'p/s614W areas -Frio&,•-I 1064 EX; f s4-a; r r , Prn✓ide -it OL1a.-r,-. /ar►s /.'vr �n i rC /Q C e ► H o,--, r S O `7"nPy ce a O �� `C de. =vL e_ ro a OF Al o IL T l of 2 0 V"e►, ; -F I ►1 D 1:13 C- 100(,. 3 F1.1 G.^ Cvic G,` Li�;n •v ; �1n .`v, t7�r���,,�a ? Received by: Date: CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / Fax 979.764.3496 FACSIMILE COVER SHEET Date: 1 Zj 2 0/0 # of pages including cover: Y Ifyou did not receive a complete fax, please call our office immediately for anew transmittal. TO: /3 or,r y a -ea h w1 Z-0",/ COMPANY: (--,-e H 5 le r RE: Ada r,, PlR z� FROM: 13eH %y%C- FAX: 7/3 - L z- 9- 9 3 y 3 COMPANY: City of College Station, Development Services REMARKS: ❑ Urgent ® For your review ❑ Replay ASAP ❑ FYI fier a 4 r e- /C Her 5 tb7 CowrP"eHfs IF -ror 3 sc,pat.-u � e lv 1De r w� : �cc/ GZ req s c '� A -erg ea c A le'OC i- i%A7�t�CQ'he. T-h 4 r h 1c �D !� TRANSMISSION VERIFICATION REPORT DATE DIME FAX NO./NAME DURATION PAGE(S) RESULT MODE TIME 12/20/2005 00:02 NAME COCS DEVELOPMENT SER FAX 9797643496 TEL 9797643570 SER.# BROE2J341073 12/20 00:01 917132299343--170 00: 01: 08 04 OK STANDARD ECM CITY OF COURGE STATION DEVELOPMENT SERVICES 110.1 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone 979.764.3570 / fax 979.764.3496 FACSIMILE. COVER SHEET Date: I z I.-e- O 0 5- # of pages including cover: If you did not receive a complete fax, plegm call our Office immedialciy for anew ftNnsm,,&1 TO: 4oL,.w FAX 7 13 — .z cj - 9 3 Y .? COMPANY: &eh 5 % i, RE: Ad'a " r f a 2 e-,- FROM: l!)ev, MG Ga fl �f CITY OF COLLEGE STATION Planning d Development Services December 20; Re: Adam Plaza- 91h Floor Core Lobby Area and 10`h Floor Offices- First American Blvd. Application # 05-3934 Dear, Bonny Jean McLoud I have completed the plan review for the above referenced project and have the following comments. The plan review is based on the 2003 International Codes, the 2002 National Electrical Code and our local amendments. Where appropriate, I have included the applicable code sections. 1. Need to submit information regarding the plan to block off finished areas from unfinished future tenant spaces, including elevator doors. 2. Submit details on the fireplace in Mr. Adam's Office. 3. Verify the accessibility of the telephone room near the board room to comply with section 704 of the ICC/ ANSI Al 17.1- 1998, Accessible and Useable Buildings and Facilities. 4. Submit verification of smokeproof enclosures for all stairways and their exit passageways to comply with section 909.20 of the 2003 IBC. 5. Need to verify and submit automatic fire alarm and emergency voice/ alarm communication system prior to installation to comply with section 907.2.12 of the 2003 International Building Code. 6. Need to submit fire sprinkler plans prior to installation. 7. Need fire extinguisher size and locations to comply with the City of College Station Fire Marshall's Office. 8. Need to submit complete lighting plan for permitted area, please include all emergency lighting, required exit signs, and exit stairway lighting to comply with section 1006 of the 2003 International Building Code. 9. Provide stairway floor number signs throughout both stairways to comply with all of section 1019.1.7 of the 2003 IBC. 10. Provide information on the door hardware, including any lock and latch devices, and emergency exit panic hardware on all exterior to comply with sections 1008.1.8.1, 1008.1.8.3, and 1008.1.9 of the 2003 IBC. The review does not include any civil or zoning issues or NRA requirements of the Unified Development Ordinance. Please respond to the plan review comments at your convenience. Three sets of plans addressing these issues will be required. Should you have any questions, contact me at 979-764-3570. Thank You Ben McCarty Plans Examiner P.O. Box 9960. 11o1 TEXAS AVENUE COLLEGE STATION • TEXAS • 77842 979.764.3570 www.csbc.gov