HomeMy WebLinkAboutRES2005-03923, 05-3970d5.3923
05 3° Q0
P
p,
Y
O
PREPARED 4/10/06, 8:16:43 INSPECTION TICKET PAGE 9
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/10/06
------------------------------------------------------------------------------------------------
ADDRESS . : 2407 NORHAM DR SUBDIV: CASTLEGATE SEC 10,11,12,13
CONTRACTOR LAFOLLETTE CONSTRUCTION PHONE (979) 690-7531
OWNER GREENS PRAIRIE INVESTORS LTD PHONE
PARCEL 184200-0103-0070
APPL NUMBER: 05-00003923 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/20/05 JGM BLDG, FOUNDATION -SLAB TIME: 17:00
12/21/05 AP December 20, 2005 3:28:10 PM kwolfe
wednesday PM
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 1/17/06 JGM BLDG, FRAMING TIME: 17:00
1/17/06 AP January 17, 2006 8:14:32 AM bkorthauer
B125 01 4 10/06 �Ip BLDG, FINAL TIME: 17:00
to(06 f� QC April 7, 2006 12:13:06 PM kwolfe
-------------------------------------- COMMENTS AND NOTES --------------------------------------
f
41 4�z e"*— , s ns Red'.
61,
ZU "', \2�11
WF0733559 /
001 City of College
Station
PAGE 1
REQ. DATE:
12/28/05
12/28/05
10:08:03
LOCATION:
2407 NORHAM DR
LOC ID:
197914
REQUESTOR:
LAFOLLETTE CONSTRUCTION
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER:
GLSOUTH
WORK TYPE:
ROUT
TEMP POLE
PASSED
TASK:.
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/28/05 SCHED
COMPLETION:
12/28/05
JOB ORDER RESULT
COW ENTS
oC5 -- 3 5 �3
WF0717265 / 001 City of College Station PAGE 1
REQ. DATE: 11/17/05 _ _ 11/17/05 9:25:45
LOCATION: 2407 NORHAM DR -' LOC ID: 197914
REQUESTOR: LAFOLLETTE CONSTRUCTION ORIGIN: CUSTOMER -WALK IN
REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT
4" SEWER TAP AND 3/4" WATER TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 11/17/05 SCHED COMPLETION: 11/17/05
********************************************************************************
JOB ORDER RESULT COM4ENTS
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 1TEXAS' AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 05-00003923 Date 11/17/05
Property Address . . . . . . 2407 NORHAM DR
Property ID: 184200-0103-0070
R #: R115344
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . CASTLEGATE SEC 10,11,12,13
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 132132
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS
------------------------
LTD LAFOLLETTE CONSTRUCTION
4490 CASTLEGATE DR
JASON LAFOLLETTE
COLLEGE STATION
TX 778453388 1723 BALL CIRCLE
COLLEGE STATION
TX 77845
(979) 690-7531
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2002.00
INTERIOR WALL TYPE
DRYWALL
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
441.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
BK
Permit Fee . . . .
559.00 Plan Check Fee
.00
Issue Date . . . .
11/17/05 Valuation . .
. . 132132
Expiration Date . .
5/16/06
Qty Unit Charge
Per
Extension
BASE FEE
460.00
33.00 3.0000
THOU BLDG, VAL 100001-500000
99.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
-------------- ---- -----------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: /�/�
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 •TEXAS' AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 05-00003923 Date 11/17/05
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
-------------------------------------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: / / __
BUILDING PERMIT
CITY OF COLLEGE STATION
1101-TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 05-00003923 Date 11/17/05
----------------------------------------------------------------------------
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120'
DEGREES
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Narrow walll bracing fully sheathed with APA garage framing
and interior anchor bolts
----------------------------------------------------------------------------
Other Fees . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 559.00 559.00 .00 .00
------------------------------------------- -- -------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number . . . . . 05-00003923 Date 11/17/05
Plan Check Total .00 .00 .00 .00
Other Fee Total 750.00 .750.00 .00 .00
Grand Total 1309.00 1309.00 .00 .00
--------------------------- -------------%�--------------
BUILDING DEPT REPRESENTATIVE: r
APPLICANT: ��
TEMPORARY POLE PERMIT
CITY OF°COLLEGE STATION
1101 , TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 05-00003970 Date 11/17/05
Property Address . . . . . . 2407 NORHAM DR
Property ID: 184200-0103-0070
R #: R115344
Application type description TEMP POLE
Subdivision Name . . . . . .. CASTLEGATE SEC 10,11,12,13
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 0
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS LTD
------------------------
LAFOLLETTE CONSTRUCTION
4490 CASTLEGATE DR
JASON LAFOLLETTE
COLLEGE STATION
TX 778453388
1723 BALL CIRCLE
COLLEGE STATION
TX 77845
(979) 690-7531
----------------------------------------------------------------------------
Permit . . . . . .
TEMP POLE
PERMIT
Additional desc . .
BK
Permit Fee . . . .
20.00
Issue Date . . . .
11/17/05
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . . .
. . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
-------------------------- -------------------------
BUILDING DEPT REPRESENTAAT%IVE:
APPLICANT: �hL—
Only
V""
CITY OF COLLEGE STATION
Planning 6 Development Servieer
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
ADDRESSI OCOCATION:
LOT _J_r BLOCK �J /
BUSINESS/OWNER NAME:
ZWO`7 NL
CONTRACTOR/HOMEOWNER:
DATE: TRCC REG LL
APPLICATION # (n0 t39a� )
TEMP POLE.#
SEC/PH_J0 -�
OA) PHONE: " Ll 1 Z - 39l
p C?79-6ga=1S,3
CONTRACTOR ADDRESS: I Z� IJLL Cl j�(,L
ELECTRICIAN: 41. L—GO PLUMBER: k5s t_ ty� n)G
HVAC: -DAke- I a GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION . RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION # SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION' SWIMMING POOL
Required)
DESCRIPTION OF WORK: /J6�_W eO1JS 7'/e,,k0TtOA)
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ J TOTAL AREA: Z�,�y HEATED AREA: 21
(Cost of Labor and Materials)
PUBLIC SEWER
.0 SEPTIC/TREATMENT SYSTEM
I I
® SEWER TAP:
WATER TAP:
OTHER TAP:
VN TEMP POLE
GARAGE TYPE
I
SIZE �(
3..
SIZE
SIZE
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
SINGLE DOUBLE'
ATTACHED iAn>DETACID� a
�&b
TRIPLE a
CARPORT a
SIGNATURE OF APPLICANT:
'If proposed work involves new com ercial con truction or facade improvements/renovations to an existing
commercial property, building elevat ons are required.
Official Use Only
_ Ip Plans Examiner
Zoning Official
mments:
YES o O
tw.—
Energy Code Compliance Information
% Glazing of exterior walls
I (� 7 —
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
3 D
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
y �'
Glazing U-Factor
R value of ductwork
A/C SEER Rating
2 .�
CITY OF COLLEGE STATION
pbnnin` d Development $mica
. Fou
II. F
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
°►. Concrete minimum f'c of 3000 PSI
B. Minimum four (4) inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
I. Footings/beams are continuous over the length and
2. Dimensions
3. Footings (30" exterior, 24" interior unless over 60' to
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
min; Floor, Wall, Ceiling and Roof Requirements
A. Girder or sill dimensions, grade & species
B. Floor foist size
i of foundation
en 30")
C re t
spacing, grade & direction of span indicted on plans
T
a ed sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
Z. Oaerabla winnnw
E
M
a. Twenty (20) inch cle
b. Maximum sill helaht
►rior wall details
1. Exterior wall
2. Sheathing it
3. Moisture barhei
J. Roof framing plan or el
K. Ceiling joist size, spec
L. Attic access location F
1. If located in p
M. Span exceeding code
N. Rafters sizes, snacim
venry-tour (24) inch clear 1
44) inches above finished
hanical ventilation is not D
m
on plans
sated on plans
on shown
bade and direction of span indicated on
ize indicated on plans
It is not to exceed 30" x 54"
is must be engineered
ide, slope and purlins if required.
fw
?.
CITY OF COLLEGE STATION
Planning d Development servlttt
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
-raming: Floor, Wall, Ceiling and Roof Requireme
O. Roof Covering
1. Roof Decking indicated on plans
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, was,
location indicated on plans
_Q. Tempered Glass required in all hazardous loca
R. Overhangs allowed on zero lot line constructic
S. Protected openings on walls < three feet from
T. One hour tenant separation to roof deck betwi
Stairway Requirements
A. Stairwav Details
1- Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max d
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft.
b. winder details
1. Treads a minimum of six (6) inches on
2. Treads a minimum of ten (10) inches
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-h-.
Z. Treads a minimum of seven and one=t
inches from the narrow edge
3. Stairway width not less than twenty-sb
4. Headroom required not less than six fl
5. All treads must be identical
ards/handrail details
1. Guards required when a porch, deck,
above grade or finished floor
2. Handrails are required on stairways Ia
3. Handrails must be thirty-four to thirty-i
leading edge of the tread
4. Handrails must not project more than
stairway
5. Guards must be a minimum of thirty-s
6. Guards & handrails along open -side(;
railing or uprights that prevent the no
. Fireplace Requirements (to be indicated on plat
A. Hearth extensions
1. Fireplace opening < 6 sq, ft, (extensii
. Fireplace opening > 6 sq ft (extensii
B. Masonry fireplace requires 2" clearance from
0. Chimneys must extend at least three (3) fee
least two (2) feet higher than any portion of
A
us tconanueal
NA/
ceiling & roofs must have the size, grade &
Lions
n up to 18"
property line
:en duplexes
K
fference
eight 6'-8"
narrow, ed e
it a distance of twelve (12) inches from the
If 9-1/2 inches
alf (7-1/2) inches at a distance of twelve ( 22)
Inches
six 6'-6")in ies
3alcony or landing is thirty (30") inches
rated four or more risers above floor/grade
ilght (34-38) inches when measured from the
four & one-half (4-1/2") inches into width of a
ix 36 inches above finished floor
�) of stairway must have intermediate
ssa a of a four (41 inch sphere
s
NAI
ins: 8" & 16" forward
ins: IT side & 20' forward
all combustible materials
higher than the highest point of roof & at
he building within ten 10 feet horizontal
1
�C
CITY OF COLLEGE STATION
Plannlna +Diwlopmmt$ mien
V. Electrical Service Recit
A. Electrical plan to
1. Electrical
2. Smoke de
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
i & switches indicated
locations) indicated as
I GFI circuits indicated where required
4. Are fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside (excludes ductless units)
B. Attic installed HN.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Ener Requirements
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zonin Ordinance Requirements — Ordinance 850
Permitted use for district
Densi re uirements
Minimum lot size
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
Maximum drive width for residence is 28' (combined for cir(
Minimum 20 feet from driveway to side (intersecting) street
Subdivision Regulations — Ordinance 690
Approved subdivision
Plat filed
Floodplaln Regulations — Ordinance 1301
Does not block any water course or divert any flow
Elevation certificate if required
A)
.10
CITY OF COLLEGE STATION
Planning d Dwlopmmt smjca
Comments:
PLANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
DATE
F
CITY OP COLLEGE STATION
Planning d'�ewlopmme Servkn
m Water Discharge Pe
Texas Pollution Discharge Elimination System General Permit NO TXR 150000,
The State of Texas assumed regulatory authority over storm water discharges associated with
construction activities, effective March 5, 2003. The regulatory requirements under the general
.permit are based upon the area of land disturbed and are classified Into two categories:
Large Construction Activity: 5 or more acres of disturbed land or part of a IaEger common Ian of
development that will disturb 5 or more acres. — n p
1. Obtain a copy of TPDES GP No. TXR 150000
2. Develop and implement a Storm Water Pollution Prevention Plan
3. Two days prior to the start of construction, submit a Notice of Intent to TCEQ
4. Provide a copy of the Notice of Intent to the City
5. Submit a Notice of Termination to TCEQ once the site has reached final stabilization
Small Construction Activity: at least 1 but less than 5 acres, or is part of a larger common development that will disturb at least 1 but -less than 5 acres. plan of
1.Obtain a copy of TPDES GP No. TXR 150000
2. Develop and implement a Storm Water Pollution Prevention Plan
3. Prior to starting construction, post a Construction Site Notice as in Part II.D.2 at the site
4. Provide a copy of the Construction Site Notice to the City
Additional information can be obtained from:
TCEQ Website: www.tnrcc.state.tx.us/permittina/waterperm/ww erm/construct.html#additional
This website provides all associated documents and explanations including NOI, GP, etc.
Compliance assistance can be obtained from: Donnie Willis
Drainage Inspector
City of College Station
979-764-6375
dwillls@cstx.gov
Laroer Common Plan of Development — A construction activity is part of a larger common plan of
development if it is completed in separate stages, separate phases, or in combination with'other
construction activities
Example 1: A subdivision is being built. You are grading 0.75 acres, another company is clearing 4
different acres, and a contractor is excavating another 0.5 acres. In this case, the total area that
would be disturbed is 5.25 acres, so each contractor would fall under the requirements associated
with disturbing 5 or more acres.
Example 2: At first, your project calls for you to grade, clear, or excavate a total of 0.93 acre. But
after your project begins, you learn that you must disturb another 0.15 acre. Because this project
has grown to disturb a total of 1.08 acres, you must obtain coverage under the requirements for
disturbing 1 to less than 5 acres.