PREPARED 6/13/06, 8:01:31 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/12/06
------------------------------------------------------------------------------------------------
ADDRESS . : 4710 JOHNSON CREEK LOOP SUBDIV: WILLIAMS CREEK PH 2
CONTRACTOR KITCHEN DESIGNS PHONE (979) 774-4571
OWNER . . PHONE
PARCEL . . 660050-0203-0060
APPL NUMBER: 05-00003906 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 11/22/05 JGM BLDG, FOUNDATION -SLAB TIME: 17:00
11/22/05 AP November 22, 2005 9:49:19 AM kwolfe
( LATE AFTERNOON
Strings On Setbacks O.K.
Slab Ground Installed
B11t5 01 1/06/06 OC BLDG, FRAMING TIME: 17:00
1/06/06 AE January 6, 2006 2:10:42 PM kwolfe
Needs Collar Ties throughout main ridge area.
Opening in wall to left of entry needs proper header size
and construction.
APA garage framing not correct, talked with Terry and ok'd
to insulate to fix all notes and get fix for Garage area
either engineered fix or panel or rebuild.
B1j0 01 1/10/06 RH BLDG, INSULATION TIME: 17:00
1/10/06 AP T/S: 01/10/2006 11:31 AM GLSOUTH -----------------------
01/10/2006 03:22 PM RH PDA
Do not cover up garage until framing for doors is fixed.
B125 01 6/12/06 BBLDG, FINAL TIME: 17:00
June 12, 2006 3:47:45 PM kwolfe
------------------------------------ COMMENTS AND NOTES -------------------------
I�u
V4/16/ZVUU IU:18 11AA UZJ ZZ70 13k(Azub ViA HhALXti
Q UU;:
Brazos Coi--. Health Department
201 NOrtIl I eras i:' -X.
Bryan, TX 77U`a,-:;1:,-1A7
(979)3614440
LICENSE TO OPF1-;--1'.!iitE AN ON SITE SEWAGE FACILITY
THIS IS TO CERTIFY that the on site sew;5!-�--,,*j: ftitility owned by.
ossF #: 2006 - 1040
KD CUSTOM HOMES
L-` 10 JOHN30N CREEK LOOP, College Ctatfor. :.?:1', 77946
G00.
WILLIAMS CREEK
Block: Lot: Certificate of Compliance: IN C.S.
Installed By: HEATH, JAMES - HEATH'S HOE SERVICE Bedrooms: 3
Engineered By: PICKENS ENVIRONMENT;;-1: L-:;:ZRVICE Employees, 0
Date Purchased: 02/27/06 Final -1:;'.,.V..-ion Date; 04118106 3-13
Disinfectant: Chlorine
The private sewage facility was installed according to the current and
minimum guidelines of the Texas on Environmental Quality (TCEQ) and
Brazos County.
This aerobic system with spr
ay di requires a disinfectant for final treatment of the
sprayed effluent. It is the rcspons:.',AR1-y of the homeowner to monitor the disinfectant
and to add more when needed. pool chlorine tablets are not acceptable
substitutes). Under no any -food crops or edible foods to be grown in
the spray area. Mowing of the on a regular basis should also be done to help
with the evaporation process,
The current maintenance contract -;.Ut system will expire 2-years from the above final
inopection date. A new mimt he in force at that time, and a copy of
the new contract filed with this days before contract expires.
This is a NON-TRANSFERABLI-i,-` Upon transfer of ownership, the new owner
shall be required to transfer the license into his/her name. Should the system
malfunction in the future, it will be:-, licensee's responsibility to bring the system in
compliance with all current state a:1*,*-;;1,;,*-;'*,1--.)unty regulations.
This lieense (toes not extend to ..Lertal's, workmtuiadp, UL rtjjL lvation, of thq
systein, so as to expressly or Fj.r -grant the owner, or installer of the system any
warranty by / or rights against Bra:;-!!,., .,C 'bunty and / or the Brazos County Health
Department, as to the quality or of the system, nor compliance with licensee's
individual sp
ecifications pecifications and but solely relates to the system meeting the
requirements of the above named V.!,W.-,_':atory body in effect as of this date.
;LaMar 08*5 M#Yba lak-but for best should be cleared back to at least a 33 foot radius
;Larger
each sprinklerheacL Sodding bare 9rounp'.:T;s1-rn40w1Ag an a regular basis will also help with the e!2g=iU6n process.
R-1 0
Health Specialist
_ BUILDING_PERNI,TT
l@I F+•
CITY OF COLLEGE STATION
1101 TEXAS AVE_,
COLLEGE STATION, TX 77840:•
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 05-00003906
Date 11/15/05
Property Address . .
. . . . 4710 JOHNSON CREEK LOOP
e.
Property ID
660050-0203-0060
,
R #
R****
".
Application type description
RESIDENTIAL, 1 UNIT DETACHED
NEW . ui nr
Subdivision Name . .
. . . . WILLIAMS CREEK PH 2
Property Use . . . .
. . . . RESIDENTIAL
• I+i a.
Property Zoning . . .
. . . . RURAL RESIDENTIAL SUB.
y`
Application valuation
. . . . 250000
Owner
Contractor
i, "
KITCHEN DESIGNS
.,
ANGEL NEGRETE
1861 BRIARCREST
DR
BRYAN
TX 77802 4s
(979) 774-4571
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
^:
Other struct info . .
. . . EXTERIOR WALL TYPE
STUCCO
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
3.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
3190.00 °+
INTERIOR WALL TYPE
: us
SHEETROCK a+=.
NUMBER OF BATHROOMS
3.50
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC ;..,
TAZ
329.00
----------------------------------------------------------------------------.
Permit . . . . . .
BUILDING PERMIT
• fi. i:
Additional desc
GS
Permit Fee . . . .
910.00 Plan Check FeeIssue
f-A.
Date . . . .
11/15/05 Valuation . .
. . 25000Expiration
Date
5/14/06
w-
Qty Unit Charge
Per
Extensiori 56!'
BASE FEE
460.00.W..
150.00 3.0000
THOU BLDG, VAL 100001-500000
450.00.a..
---------------------------------------------------------------------------=
Special Notes and Comments
.s
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
-----------------------------------------
BUILDING DEPT REPR.E NTATIVE:-
APPLICANT:
BUILDING,,PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Page • 2 :.
Application Number _ _ . . . 05-00003906 Date 11/15/05..
--------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211
J'biW%
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
OBTAIN HEALTH DEPARTMENT APPROVAL: CALL 979-361-4440 FOR
MORE INFORMATION. SEPTIC SYSTEMS INSTALLED
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION -..
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE`°'
0
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
„.
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
°
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
41
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED„:.
. w..
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
w"
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT,b,
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
v"
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
y.,.
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECT
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
------------------------------------------ ------�---- - - -----------`='
BUILDING DEPT REPR ENTATIVE :
APPLICANT: �_•
BUILDING, PERM+IT •ma.
CITY OF COLLEGE STATION
1101 TEXAS AVE_
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
m-
- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
Page 3
Application Number . . . . . 05-00003906 Date 11/15/05
hl oo
----------------------------------------------------------------------——---
Special Notes and Comments
G+do
annular space at ends with caulk, foam or other means.+
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ".
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24+' OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
--——— — — — — ——
.Wav
c.
tii�Fs
I
buiL1JIINU 11hx1v1,L'1'
CITY OF COLLEGE STATION
1101 TEXAS AVE 4:..
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------.
,4w,
Page
4; '
Application Number . . . . . 05-00003906 Date
11/15/054o7v
----------------------------------------------------------------------------
Special Notes and Comments
".
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
I RC)�
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
,
PRIVATE GARAGES
Narrow wall bracing fully sheathed with APA framing at
r.•a;
garage and other designated areas.
up.
Minimum finished floor of 244.0' required for sewer only.
.�.
U{YF
30
" culvert required.
,..,
------------------------------- ---------------------------------------------
Fee summary Charged Paid Credited
----------
Due
-----------------------------------------------
Permit Fee Total 910.00 910.00 .00
.00
Plan Check Total .00 .00 .00
.00
Grand Total 910.00 910.00 .00
.00
:y+o.
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
. dIJi6
COLLEGE.STATION, TX 77840 uia1.
PHONE: (979)764-3570 FAX: (979)764-3496
---------------------------------------------------------------------------=.:
Application Number . . . . . 05-00003907 Date 11/15/05
Property Address . . . . . . 4710 JOHNSON CREEK LOOP
Property ID . . . . . . . . . 660050-0203-0060 '
Application type description TEMP POLE '
Subdivision Name . . . . . . WILLIAMS CREEK PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . RURAL RESIDENTIAL SUB.
P Y 9
Application valuation . . . . 0
Owner Contractor•
------------------------------------------------ A.
KITCHEN DESIGNS
ANGEL NEGRETE
1861 BRIARCREST DR
BRYAN TX 77802
(979) 774-4571
Permit . . . . . . TEMP POLE PERMIT ;;y;
Additional desc GS
�LI d1
Permit Fee . . . . 20.00 sJ°.
Issue Date . . . . 11/15/05 Valuation . . . . Oh;;
----------------------------------------------------------------------------,..
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee .Total 20.00 20.00 .00 .00
Grand Total 20.00 20.00 .00 .00
;1>
Leyn
014°
• �i. du
Dl db
1i1a
m i/11 F
BUILDING DEPT REPRESENTATIVE -
APPLICANT:
S Y•
y iM'�L
1�LL
CITY OF COLLEGE STATION
Planning & Development'Servicer
ADDRESCATION:
LOT BLOCK
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764.3570 (979) 764-3496 FAX
WVWV.CSTX.GOV
I i fi2For Ofte use only
DATE: b l-V J"�RCC REG
APPLICATION # (llJ,�j' ✓ 1"
TEMP POLE .# vJ ` _2*1C10 I
BUSINESS/OWNER NAME: le-"D« V1 e_1_ PHONE:_�17 y-14 S 7,
CONTRACTOR/HOMEOWNER: PHONE:_
CONTRACTOR ADDRESS: 13 l �� t_
6
ELECTRICIAN: L I,'?t Ig ooc- PLUMBER: tT
HVAC: L K V L c� GOOD CENTS (Residential only):
CLASS OF WORK
7
ACCESSORY/STORAGE LOCATION . RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION*. SWIMMING POOL
Required) 1 r
DESCRIPTION OF WORK: `�1QW tt�tdr'
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 2-5 0, 00 C D TOTAL AREA: 5Co CD HEATED AREA: 3j q L3
(Cost of Labor and Materials)
PUBLIC SEWER
1 SEPTIC/TREATMENT SYSTEM
SEWER TAP:
a WATER TAP:
F] OTHER TAP:
D rt) //TEMP POLE
NG;&AGE TYPE:
SIZE
SIZE
SIZE
SINGLE
ATTACHED EZ
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE a TRIPLE'
)ETACHED IF—] CARPORT
SIGNATURE OF APPLICANT:
*If proposed work involves new commej_"n'tTruCtionMcade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
ments:.
Sjr NO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
7 v
Insulation R value of exterior walls
CZ
Insulation R value of ceiling 1 (flat areas)
Q �J
2 (.v)
Insulation R value of ceiling(vaulted areas/no attic
Glazing SHGC
- C%n
Glazing U-Factor
/
R value of ductwork
A/C SEER Rating
4/
PLAN REVIEW
ONE and TWO FAMILY
OCC
CITY OF COLLEGE STATION UPANCY REQUIREMENTS
Planninj d bcvilopmmt $mica
PLAN REVIEW/PERMIT NUMBER# D S -
BUILDING ADDRESS:
I. Foundation Requirements
A. Concrete minimum f'c of 3000 PSI
B, Minimum four (4) inch slab thickness
C. Vapor barrier
1. 6 will poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the len-0
2. Dimensions
3. Footings (30" exterior, 24" interior unless over i
4. Spacmg of beams does not exceed 15'
E. Reinforcement details to meet minimum re uirements
o 6 DATE: 11 1 �► log
��1Sa�1 Cif pp% jn.
and width of found
0' Long then 30")
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. M:;qnnry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing; Floor, Wall. Ceiling and Roof Requirements
A. Girder or sill dimensions grade & species
B. Floor joist size, spacing, grade & direction of span indicted on
C. Treated sill plate or bottom plate
D. Narrow Wall Bra cin Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Ooerabla window
a. Twenty (20) inch clear width by twenty four (24) inch clear height
b. Maximurn sill height of forty-four (44) inches above finished floor
bathroom window required when mechanical ventilation is not provided
e and spacing
all rinfa7ls
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing plan or elevation shown
K. Ceiling Joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
I. If located In garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
00l
AA
� PLAN
REVIEW
ONE and TWO FAMILY
CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS
Planning del Development Soviet,
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade
location indicated on Dians
Q. Tempered Glass required in all hazardous locations
R. Overhan s allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
A Stairwav Detadc
1. Maximum riser hei ht 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max difference
4 Stairwa width not less than 36 inches
5. Stairway headroom not less that six ft.
B. Winder details
1. Treads a minimum of six 6 inches on narrow eel e
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow eel e
C. Spiral stairway details
1 Riser hei ht less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one=half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairwav width not less than twen -six inches
4. Headroom required not less than six ft six 6'-6" inches
5. All treads must be identical
D. Guards/hnnriraii
1. Guards
2. H
3. H
4
cony or landing is
ae or finished floor
are required on stairways located
must be thirty-four to thirty-eight
I_ge of the tread
must not project more than four 8
a porch, deck,
inches
r or more risers above floor/grade
38) inches when measured from the
(4-1/2") inches into width of a
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open -sides) of stairway must have intermediate
railing or uprights that prevent the passage of a four (4) inch sphere
rv. Fireplace Requirements (to be Indicated on plans)
1. Fireplace opening < 6 sq, ft, (extensions: 8" & 16" forward)
2. Fireplace opening > 6 sq. ft (extensions: 12' side & 20" forward)
B. Masonry fireplace requires 2" clearance from all combustible materials
!✓ Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two (2) feet higher than any portion of the building within ten (10) feet horizontal
1)
CITY OF COLLEGE STATION
Planning 6, Dmloptmmt $mica
V. Electrical Service Reat
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
:trical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector location(s) indicated as required
4. Are fault protection for bedroom circuits
5. Panel and Meter location —
VI. Plumbing Requirements
A Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
A All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside (excludes ductless units)
B. Attic installed HN.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when reauired)
L Energy Requirements
A. Compliance software worksheet (REScheck) submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window
etc.)
nance R
itted use
uensity requirements
Minimum lot size
Setbacks
Easements
Required parking _
On zero lot side 18" max.
Street Ordinance Requirement
Maximum drive width for
Minimum 20 feet from dri,
Subdivision
— ordinance 850
nce is 28' (combined for
to side (intersecting) sti
— Ordinance 690
on
Plat filed
Floodplaln Regulations — Ordinance 130
Does not block any water course or
Elevation certificate if reaulred
any
ar`
ray'
C
CITY OP COLLEGE STATION
Planning d Dtwkpmmt gmira
PLANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
/(- fg-o-
DATE
CM OF COLLEGE STATION
XdWaiq d, Dnafopmmr &rvka
torm Water Discharge P
Texas Pollution Discharge Elimination System General Permit NO TXR 150000,
The State of Texas assumed regulatory authority over storm water discharges associated with
construction activities, effective March 5, 2003. The regulatory requirements under the general
.permit are based upon the area of land disturbed and are classified into two categories:
Large Construction Activity: 5 or more acres of disturbed land or part of a larger commoNadevelopment that will disturb 5 or more acres., - a n pl n of
1. Obtain a copy of TPDES GP No. TXR 150000
2. Develop and implement a Storm Water Pollution Prevention Plan
3. Two days prior to the start of construction, submit a Notice of Intent to TCEQ
4. Provide a copy of the Notice of Intent to the City
5. Submit a Notice of Termination to TCEQ once the site has reached final stabilization
Small Construction Activity: at least 1 but less than 5 acres, or is part of a larger common plan of
development that will disturb at least 1 but less than 5 acres.
1. Obtain a copy of TPDES GP No. TXR 150000
2. Develop and implement a Storm Water Pollution Prevention Plan
3. Prior to starting construction, post a Construction Site Notice as in Part II.D.2 at the site
4. Provide a copy of the Construction Site Notice to the City
Additional information can be obtained from:
TCEQWebsite:www.tnrcc.5tate.x.us/permittin-q/water erm/ww erm/construct.html#additional
This website provides all associated documents and explanations including NOI, GP, etc.
Compliance assistance can be obtained from: Donnie Willis
Drainage Inspector .
City of College Station
979-764-6375
dwillis@cstx.gov
L- steer Common Plan of Development — A construction activity is part of a larger common plan of
development if it is completed in separate stages, separate phases, or in combination with 'other
construction activities
Example 1: A subdivision is being built. You are grading 0.75 acres, another company is clearing 4
different acres, and a contractor is excavating another 0.5 acres. In this case, the total area that
would be disturbed is 5.25 acres, so each contractor would fall under the requirements associated
with disturbing 5 or more acres.
Example 2: At first, your project calls for you to grade, clear, or excavate a total of 0.93 acre. But
after your project begins, you learn that you must disturb another 0.15 acre. Because this project
has grown to disturb a total of 1.08 acres, you must obtain coverage under the requirements for
disturbing 1 to less than! 5 acres.