Loading...
HomeMy WebLinkAboutRES2005-03902WF0715662 / 001 City of College Station PAGE 1 >..r. REQ. DATE: 11/10/05 11/10/05 13:44:59°;_ LOCATION: 4103 HALIFAX DR LOC ID: 201816-,: REQUESTOR: ED FROEHLING BUILDER, INC ORIGIN: CUSTOMER -WALK IN .:U�;.. REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: 4" SWR TAP 3/4" WTR TAP TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 11/10/05 SCHED COMPLETION: 11/10/054;; JOB ORDER RESULT COMVIEDTTS BUILDING PERMIT CITY 01�.. CRGVLEGE "STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 444 ----------------------------------------------------------------------------s,:,. . bis Application Number . . . . . 05-00003902 Date 11/10/05 Property Address . . . . . . 4103 HALIFAX DR �. Property ID: Y569500-1339-0350 R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . R301839 RESIDENTIAL, 1 UNIT DETACHED NEW SHENANDOAH PH 13 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 116490 Owner Contractor ------------------------ ------------------------ FROEHLING, EDWARD ED FROEHLING BUILDERS 3887 HIGH LONESOME ED FROEHLING COLLEGE STATION TX 778459443 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1765.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 427.00 ---------------------------------------------------------------------------- m Permit . . . . . . BUILDING PERMIT Additional desc KW Permit Fee . . . . 511.00 Plan Check Fee .00' Issue Date . . . . 11/10/05 Valuation . . . . 116490 Expiration Date . . 5/09/06 Qty Unit Charge Per Extension-i ii ­ BASE FEE 460.09AL, 17.00 3.0000 THOU BLDG, VAL 100001-500000 51.00 ---------------------------------------------------------------------------:-i6w_ Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) BUILDING DEPT/,_f/EfRESENTATI:"VE: APPLICANT: BUILDING PERMIT CITY OP COftEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 M.. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -.I.. q�• M Page 2 Application Number . . . . . 05-00003902 Date 11/10/05 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE BUILDING DEPT)nEPRESENT TIVE: APPLICANT: BUILDING PERMIT CITY 0t' COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- 014: Page Yl a 3 Application Number . . . . . 05-00003902 Date 11/10/05 L... ----------------------------------------------------------------------------,. Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL ; BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR ,;... DUCTS, CEILING FANS AND RETURN AIR`" PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 *« DEGREES e „ ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY �.. REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE.ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES! Narrow wall bracing fully sheathed and APA framing at garage and dining area. — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — .., W Al. — — — — — — — — — — Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ----------------------------------------------------------------------------,.. Fee summary Charged Credited --------Paid ------_Due - BUILDING DEPT,,,AEPRESENTATIVE APPLICANT: BUILDING PERMIT CITY OP COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: ----------------------------------------------------------------------------" (979)764-3570 FAX: (979)764-3496 «r Page 4 Application Number . . . . . 05-00003902 Date 11/10/05 ----------------- Permit Fee Total ------------------------------ 511.00 511.00 .00 ---------- .00 Plan Check Total .00 .00 .00 .00 Ak Other Fee Total 150.00 750.00 .00 .00 Grand Total 1261.00 1261.00 .00 .00 NaJli�u. .w.N y1L. ,all Wr Ar. •.a..WyW. e:yldu f 1 BUILDING DEPT REPRESENTATIVE: a. APPLICANT: JAM.;„ U�. CITY OF COLLEGE STATION Pianding d Devetopmrnt'Srrvicrt APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764.3570 (979) 764.3496 FAX WWW.CSTX.GOV ror Vmce use Only DATE: C REG APPLICATION # TEMP POLE .# ADDRESS/LOCATION: 4-� bzj l- t-� �_ b�z� v t= "'/ ?j5✓B LOT LOCK "F1 SUBDIVISION �jHEt-API NC)OAt-� _eSEC/PH �J BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: V7gr Ii_i��C-, t�k_l I1\1C PHONE: 77(..a—�jZCoC� CONTRACTOR ADDRESS:i ELECTRICIAN: .13AI5 ELa:j-QIC 5 PLUMBER: HVAC: �� • l NNOVA� VEt%j GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION. RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: STRUCTURE USE: jltvCERLIS- \ �wt i L_�( I:FsI t�llt HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ � � k�r AgO <'JP ' TOTAL AREA: �22t! i HEATED AREA: �5_ ( Cost of Labor and Materials) W15"4 PUBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM SEWER TAP: SIZE EWATER TAP: 5/411 NUMBER OF BEDROOMS: NUMBER OF BATHROOMS INTERIOR WALL TYPE: z_ 5V4EErReGy__ EXTERIOR WALL TYPE: 1EjR lGjL JIZE OTHER TAP: FOUNDATION TYPE: 1j LPI�r 2A S IZE r�J TEMP POLE �V - o �' ROOF TYPE: ` i� C-b i nC�� GARAGE TYPE: SINGLE F-1 DOUBLETRIPLE' a ATTACHED [2r DETACHED CARPORT a SIGNATURE OF APPLICANT: *If proposed work involves new commerc commercial property, building elevations ark Plans Examiner _ all r,A l -.. C requiuctlon or facade improykmen enovations to an existing requir ( \ Official Use Only _ Zoning Official or NO IV "I Energy Code Compliance Information 4M5 % Glazing of exterior walls Insulation R value of exterior walls 3 / Insulation R value of ceiling 1 (flat areas) 3� Insulation R value of. ceiling 2 (vaulted areas/no attic) o4 P. Glazing SHGC Glazing U-Factor R value of ductwork / A/C SEER Rating l0 - Sam � PLA N REVIEW ONE and TWO FAMILY CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS Alinninj J. Divilopmmss rviea PLAN REVIEW/PERMIT NUMBER# 01 BUILDING ADDRESS:DATE:&L" I. Foundation Requirements A. Concrete minimum f'c of 3000 PSI NAJO B, Minimurn four 4 Inch slab thickness C. Va or barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footin s/beams are continuous over the length and width of foundation 2. Dimensions 3. Footin s 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Mason fire lace foundation reinforcement F. Wood foundation details indicated II. Framin : Floor Wall, Ceiling and Roof Requirements A. Girder or sill dimensions grade & s ecies N B. Floor joist sizes acingrade & direction of s an indicted onplans C. Treated sill Plate or bottom plate D. Narmw Wall Bracin Methods indicated on plans E. Header sizes indicated on tans F. Emergency bedroom a ress 1. Exit direct to outside 2. Operable window a. Twen 20 inch clear width b twen -four 24 inch clear hei ht b. Maximum sill height of fo -four (AA1 inches above finished floor G. O erable bathroom window required when mechanical ventilation is not provided H. Stud rade andspacing I. Exterior wall details 1. Exterior wall coverin indicated on plans 2. Sheathin indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceilingjoist size s acin rade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located In garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes s acln rade Slope and purlins if reauired. 4,. � PLAN REVIEW ONE and TWO FAMILY CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS Planning d Dwilopmine Soviets I. Framing: Floor, Wall Ceiling and Roof Requirements (continued) O. Roof Covering I. Roof Dec Ing indicated on plans. 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade location indicated on plans Q. Tem ered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes III. Stairway Requirements A Stairwav DPG5_Q 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairwa risers are uniform 3/8" Max. difference 4. Stairwa width not less than 36 inches 5. Stairwa headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow ed e 2. Treads a minimum of ten (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairwaydetails 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one=half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twen -six inches 4. Headroom required not less than six ft six 6'-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or. more risers above floor/ rade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the loading,ed a of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairwa 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open -sides) of stairway must have intermediate railin or u ri hts that revent the assa a of a four 4 inch s here tV. Fireplace Requirements (to be indicated on plans) A Heerth eXtAnainne j. rireplace opening < 6 sq, ft, 'extensions: 8" & 16' forward) 2 Fire lace o enln9 > 6 sq. ft. (extensions 12' side & 21 forward) B. Maso, fireplace requires 2' clearance from all combustible materials G Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two (2) feet higher than any portion of the building within ten (10) feet horizontal 2 AN CITY OF COLLEGE STATION Planning 6 Dtwloptnmt $mica V. Electrical Service Requiremen A. Electrical Ian to include; 1. Electrical fixtures 2. Smoke detectnr It PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS ndicated as required 4. Are fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements A All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside (excludes ductless units) B. Attic installed HN.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) VIII. Energy,Requirements A. Compliance software worksheet (RESchPrtkl submitt d a. Energy data supplied (Percent of gl etc.) Zoning Ordinance Requirements — Ordinance 850 Permitted use for district __ Density requirements Minimum lot size On zero lot side 18" Street Ordinance Ramilra ium drive width for residence is 28' Urn 20 feet from driveway to side fii Subdivision Regulations — Ordinance 690 e , or :ing, insulation R-values, window U-values, loodplaln Regulations — Ordinance 1301 Does not block any water course or divert any flow . __ for circ street ix CITY OF COLLEGE STATION Planning d Dtwlopmmt emjca omm PLANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS DATE CITY OP COLLEGE STATION PGmnBg d+DVWkPmmt &rakY, Water Discharge Pe Texas Pollution Discharge Elimination System General Permit NO TXR 150000, The State of Texas assumed regulatory authority over storm water discharges associated with construction activities, effective March 5, 2003. The regulatory requirements under the general .permit are based upon the area of land disturbed and are classified into two categories: Large Construction Activity: 5 or more acres of disturbed land or part of a common la development that will disturb 5 or more acres. larger n n of 1.Obtain a copy of TPDES GP No. TXR 150000 2. Develop and implement a Storm Water Pollution Prevention Plan 3. Two days prior to the start of construction, submit a Notice of Intent to TCEQ 4. Provide a copy of the Notice of Intent to the City S. Submit a Notice of Termination to TCEQ once the site has reached final stabilization Small Construction Activity: at least 1 but less than 5 acres, or is part of a larger common plan of development that will disturb at least 1 but less than 5 acres. 1. Obtain a copy of TPDES GP No. TXR 150000 2. Develop and implement a Storm Water Pollution Prevention Plan 3. Prior to starting construction, post a Construction Site Notice as in Part II.D.2 at the site 4. Provide a copy of the Construction Site Notice to the City Additional information can be obtained from: TCEQWebsite:www.tnrcc. state. ',.us/ermittin /water erm/ww erm/construct.html#additional This website provides all associated documents and explanations including NOI, GP, etc. Compliance assistance can be obtained from: Donnie Willis Drainage Inspector City of College Station 979-764-6375 dwillls@cstx.gov L_ aroer Common Plan of Development — A construction activity is part of a larger common plan of development if it. is completed in separate stages, separate phases, or in combination with'other construction activities Example 1: A subdivision is being built. You are grading 0.75 acres, another company is clearing 4 different acres, and a contractor is excavating another 0.5 acres. In this case, the total area that would be disturbed is 5.25 acres, so each contractor would fall under the requirements associated with disturbing 5 or more acres. Example 2: At first, your project calls for you to grade, clear, or excavate a total of 0.93 acre. But after your project begins, you learn that you must disturb another 0.15 acre. Because this project has grown to disturb a total of 1.08 acres, you must obtain coverage under the requirements for disturbing 1 to less than! 5 acres. L r. L V 'J J V V) nit: , 6 1; v! lb U: t' P I I C L 11 U I 0� BUffPl9.d� .��`+iP.r/i� "Cove, jb&,Y,1P.,r�9�Pl�il9°/ Lot 7 Now cr Forrnerly Ed Froohfingg Build®r, Inc, $herwndarh Pl7osv F? Val, 8580, Pg. 2.13 lMl. a6o, Pv. 2fJ S/ock .3.9 10' P,U,E, 65.00 F10' P.U.E. � Note: ®Wlding Setback Lines per � City of College Stotion Un.Ged $' ! ?C 1 Development Drdnonce 02617 ' 7.5' • y $ N s. 8 ! ! 20' I Lot ate, Block s99 w� I Shenam*vh Phase 1.3 LDL 36 Nov or Formerly ley b Lei 34 Ed Freehling Builder, ll I v Now or Famurly Vol. 6580. Pg. 214 Ed Freehling 804ar, Inc. � E n Vol, 0580. Pg. 71e In A Proposed ! Residence .� 7,e' 10.4, 20' I I C 21.0' 7.7' ir! � ConGYc� I rl'i ! OYiJ� -� In I .• Bcck/G�rb.� Lf (03 Halifax ®�rva 50' R.f. !N, — 27' Havernent Wol, $580, Pg 21 d Aub �p V REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\1202MV.rck TITLE: 4103 Halifax Drive CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 11 /02/05 DATE OF PLANS: 4/8/05 PROJECT INFORMATION: Lot 35 Block 39 Shenandoah Phase 13 COMPANY INFORMATION: ED FROEHLING BUILDER, INC NOTES: New 4-Bedroom 1765 Sqft COMPLIANCE: Passes Maximum UA = 657 Your Home UA = 607 7.6% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.36 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Front Projection factor: 0.19 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Left Side Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1765 30.0 0.0 62 396 13.0 0.0 25 50 0.640 32 38 0.400 15 402 13.0 0.0 28 46 0.640 29 Projection factor: 0.27 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 45 deg. from North; Comp. orient.: Left Side Projection factor: 0.81 Wall 3: Wood Frame, 16" o.c. 396 13.0 0.0 21 Window 3: Metal Frame:Double Pane with Low-E 134 0.640 86 SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Back Projection factor: 0.23 Wall 4: Wood Frame, 16" o.c. 402 13.0 0.0 32 Window 4: Metal Frame:Double Pane with Low-E 9 0.640 6 SHGC: 0.40 Bldg. faces 45 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Floor 1: Unheated 250 0.0 261 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 10 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements m RESc ion 3. elease 1b (formerly MECchec/ and to comply with the mandatory requirements listed in the RES checkI ection Che list. Builder/Designer