HomeMy WebLinkAboutRES2005-03902WF0715662 / 001 City of College Station PAGE 1
>..r.
REQ. DATE:
11/10/05
11/10/05
13:44:59°;_
LOCATION:
4103 HALIFAX DR
LOC ID:
201816-,:
REQUESTOR:
ED FROEHLING BUILDER, INC ORIGIN:
CUSTOMER -WALK IN
.:U�;..
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
4" SWR
TAP 3/4" WTR TAP
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START: 11/10/05 SCHED COMPLETION:
11/10/054;;
JOB ORDER
RESULT COMVIEDTTS
BUILDING PERMIT
CITY 01�.. CRGVLEGE "STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
444
----------------------------------------------------------------------------s,:,.
. bis
Application Number . . . . . 05-00003902 Date 11/10/05
Property Address . . . . . . 4103 HALIFAX DR �.
Property ID: Y569500-1339-0350
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
R301839
RESIDENTIAL, 1 UNIT DETACHED NEW
SHENANDOAH PH 13
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
116490
Owner Contractor
------------------------ ------------------------
FROEHLING, EDWARD ED FROEHLING BUILDERS
3887 HIGH LONESOME ED FROEHLING
COLLEGE STATION TX 778459443 3887 HIGH LONESOME RD
COLLEGE STATION TX 77845
(979) 776-8266
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1765.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
TAZ 427.00
----------------------------------------------------------------------------
m
Permit . . . . . . BUILDING PERMIT
Additional desc KW
Permit Fee . . . . 511.00 Plan Check Fee .00'
Issue Date . . . . 11/10/05 Valuation . . . . 116490
Expiration Date . . 5/09/06
Qty Unit Charge Per Extension-i ii
BASE FEE 460.09AL,
17.00 3.0000 THOU BLDG, VAL 100001-500000 51.00
---------------------------------------------------------------------------:-i6w_
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
BUILDING DEPT/,_f/EfRESENTATI:"VE:
APPLICANT:
BUILDING PERMIT
CITY OP COftEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
M..
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -.I..
q�•
M
Page 2
Application Number . . . . . 05-00003902 Date 11/10/05
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
BUILDING DEPT)nEPRESENT TIVE:
APPLICANT:
BUILDING PERMIT
CITY 0t' COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
014:
Page
Yl a
3
Application Number . . . . . 05-00003902 Date
11/10/05 L...
----------------------------------------------------------------------------,.
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
;
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
,;...
DUCTS, CEILING FANS AND RETURN AIR`"
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
*«
DEGREES
e „
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
�..
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE.ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES!
Narrow wall bracing fully sheathed and APA framing at
garage and dining area.
— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
.., W Al.
— — — — — — — — — —
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------,..
Fee summary Charged Credited
--------Paid
------_Due
-
BUILDING DEPT,,,AEPRESENTATIVE
APPLICANT:
BUILDING PERMIT
CITY OP COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE:
----------------------------------------------------------------------------"
(979)764-3570 FAX: (979)764-3496
«r
Page 4
Application Number
. . . . . 05-00003902
Date 11/10/05
-----------------
Permit Fee Total
------------------------------
511.00 511.00
.00
----------
.00
Plan Check Total
.00 .00
.00
.00
Ak
Other Fee Total
150.00 750.00
.00
.00
Grand Total
1261.00 1261.00
.00
.00
NaJli�u.
.w.N
y1L.
,all
Wr
Ar.
•.a..WyW.
e:yldu
f
1
BUILDING DEPT REPRESENTATIVE: a.
APPLICANT: JAM.;„
U�.
CITY OF COLLEGE STATION
Pianding d Devetopmrnt'Srrvicrt
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764.3570 (979) 764.3496 FAX
WWW.CSTX.GOV
ror Vmce use Only
DATE: C REG
APPLICATION #
TEMP POLE .#
ADDRESS/LOCATION: 4-� bzj l- t-� �_ b�z� v t= "'/
?j5✓B LOT LOCK "F1 SUBDIVISION �jHEt-API NC)OAt-� _eSEC/PH �J
BUSINESS/OWNER NAME:
PHONE:
CONTRACTOR/HOMEOWNER: V7gr Ii_i��C-, t�k_l I1\1C PHONE: 77(..a—�jZCoC�
CONTRACTOR ADDRESS:i
ELECTRICIAN: .13AI5 ELa:j-QIC 5
PLUMBER:
HVAC: �� • l NNOVA� VEt%j GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION. RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK:
STRUCTURE USE: jltvCERLIS- \
�wt i L_�( I:FsI t�llt
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ � � k�r AgO <'JP ' TOTAL AREA: �22t! i HEATED AREA: �5_
(
Cost of Labor and Materials) W15"4
PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
SEWER TAP:
SIZE
EWATER TAP: 5/411
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
z_
5V4EErReGy__
EXTERIOR WALL TYPE: 1EjR lGjL
JIZE
OTHER TAP: FOUNDATION TYPE: 1j LPI�r 2A
S IZE
r�J TEMP POLE �V - o �' ROOF TYPE: ` i� C-b i nC��
GARAGE TYPE: SINGLE F-1 DOUBLETRIPLE' a
ATTACHED [2r DETACHED CARPORT a
SIGNATURE OF APPLICANT:
*If proposed work involves new commerc
commercial property, building elevations ark
Plans Examiner
_ all
r,A l -..
C
requiuctlon or facade improykmen enovations to an existing
requir ( \
Official Use Only _
Zoning Official
or NO
IV "I
Energy Code Compliance Information 4M5
% Glazing of exterior walls
Insulation R value of exterior walls
3 /
Insulation R value of ceiling 1 (flat areas)
3�
Insulation R value of. ceiling 2 (vaulted areas/no attic)
o4 P.
Glazing SHGC
Glazing U-Factor
R value of ductwork
/
A/C SEER Rating
l0 - Sam
� PLA
N REVIEW
ONE and TWO FAMILY
CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS
Alinninj J. Divilopmmss rviea
PLAN REVIEW/PERMIT NUMBER# 01
BUILDING ADDRESS:DATE:&L"
I. Foundation Requirements
A. Concrete minimum f'c of 3000 PSI NAJO
B, Minimurn four 4 Inch slab thickness
C. Va or barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footin s/beams are continuous over the length and width of foundation
2. Dimensions
3. Footin s 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Mason fire lace foundation reinforcement
F. Wood foundation details indicated
II. Framin : Floor Wall, Ceiling and Roof Requirements
A. Girder or sill dimensions grade & s ecies N
B. Floor joist sizes acingrade & direction of s an indicted onplans
C. Treated sill Plate or bottom plate
D. Narmw Wall Bracin Methods indicated on plans
E. Header sizes indicated on tans
F. Emergency bedroom a ress
1. Exit direct to outside
2. Operable window
a. Twen 20 inch clear width b twen -four 24 inch clear hei ht
b. Maximum sill height of fo -four (AA1 inches above finished floor
G. O erable bathroom window required when mechanical ventilation is not provided
H. Stud rade andspacing
I. Exterior wall details
1. Exterior wall coverin indicated on plans
2. Sheathin indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceilingjoist size s acin rade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located In garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes s acln rade Slope and purlins if reauired.
4,.
� PLAN
REVIEW
ONE and TWO FAMILY
CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS
Planning d Dwilopmine Soviets
I. Framing: Floor, Wall Ceiling and Roof Requirements (continued)
O. Roof Covering
I. Roof Dec Ing indicated on plans.
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade
location indicated on plans
Q. Tem ered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
A Stairwav DPG5_Q
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairwa risers are uniform 3/8" Max. difference
4. Stairwa width not less than 36 inches
5. Stairwa headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow ed e
2. Treads a minimum of ten (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairwaydetails
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one=half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twen -six inches
4. Headroom required not less than six ft six 6'-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or. more risers above floor/ rade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
loading,ed a of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairwa
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open -sides) of stairway must have intermediate
railin or u ri hts that revent the assa a of a four 4 inch s here tV. Fireplace Requirements (to be indicated on plans)
A Heerth eXtAnainne
j. rireplace opening < 6 sq, ft, 'extensions: 8" & 16' forward)
2 Fire lace o enln9 > 6 sq. ft. (extensions 12' side & 21 forward)
B. Maso, fireplace requires 2' clearance from all combustible materials
G Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two (2) feet higher than any portion of the building within ten (10) feet horizontal
2
AN
CITY OF COLLEGE STATION
Planning 6 Dtwloptnmt $mica
V. Electrical Service Requiremen
A. Electrical Ian to include;
1. Electrical fixtures
2. Smoke detectnr It
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
ndicated as required
4. Are fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
A All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside (excludes ductless units)
B. Attic installed HN.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
VIII. Energy,Requirements
A. Compliance software worksheet (RESchPrtkl submitt d
a. Energy data supplied (Percent of gl
etc.)
Zoning Ordinance Requirements — Ordinance 850
Permitted use for district
__ Density requirements
Minimum lot size
On zero lot side 18"
Street Ordinance Ramilra
ium drive width for residence is 28'
Urn 20 feet from driveway to side fii
Subdivision Regulations — Ordinance 690
e , or
:ing, insulation R-values, window U-values,
loodplaln Regulations — Ordinance 1301
Does not block any water course or divert any flow
. __
for circ
street
ix
CITY OF COLLEGE STATION
Planning d Dtwlopmmt emjca
omm
PLANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
DATE
CITY OP COLLEGE STATION
PGmnBg d+DVWkPmmt &rakY,
Water Discharge Pe
Texas Pollution Discharge Elimination System General Permit NO TXR 150000,
The State of Texas assumed regulatory authority over storm water discharges associated with
construction activities, effective March 5, 2003. The regulatory requirements under the general
.permit are based upon the area of land disturbed and are classified into two categories:
Large Construction Activity: 5 or more acres of disturbed land or part of a common la
development that will disturb 5 or more acres. larger n n of
1.Obtain a copy of TPDES GP No. TXR 150000
2. Develop and implement a Storm Water Pollution Prevention Plan
3. Two days prior to the start of construction, submit a Notice of Intent to TCEQ
4. Provide a copy of the Notice of Intent to the City
S. Submit a Notice of Termination to TCEQ once the site has reached final stabilization
Small Construction Activity: at least 1 but less than 5 acres, or is part of a larger common plan of
development that will disturb at least 1 but less than 5 acres.
1. Obtain a copy of TPDES GP No. TXR 150000
2. Develop and implement a Storm Water Pollution Prevention Plan
3. Prior to starting construction, post a Construction Site Notice as in Part II.D.2 at the site
4. Provide a copy of the Construction Site Notice to the City
Additional information can be obtained from:
TCEQWebsite:www.tnrcc. state. ',.us/ermittin /water erm/ww erm/construct.html#additional
This website provides all associated documents and explanations including NOI, GP, etc.
Compliance assistance can be obtained from: Donnie Willis
Drainage Inspector
City of College Station
979-764-6375
dwillls@cstx.gov
L_ aroer Common Plan of Development — A construction activity is part of a larger common plan of
development if it. is completed in separate stages, separate phases, or in combination with'other
construction activities
Example 1: A subdivision is being built. You are grading 0.75 acres, another company is clearing 4
different acres, and a contractor is excavating another 0.5 acres. In this case, the total area that
would be disturbed is 5.25 acres, so each contractor would fall under the requirements associated
with disturbing 5 or more acres.
Example 2: At first, your project calls for you to grade, clear, or excavate a total of 0.93 acre. But
after your project begins, you learn that you must disturb another 0.15 acre. Because this project
has grown to disturb a total of 1.08 acres, you must obtain coverage under the requirements for
disturbing 1 to less than! 5 acres.
L r. L V 'J J V V) nit: , 6 1; v! lb U: t' P I I C L 11 U I
0� BUffPl9.d� .��`+iP.r/i� "Cove, jb&,Y,1P.,r�9�Pl�il9°/
Lot 7
Now cr Forrnerly
Ed Froohfingg Build®r, Inc,
$herwndarh Pl7osv F? Val, 8580, Pg. 2.13
lMl. a6o, Pv. 2fJ
S/ock .3.9
10' P,U,E, 65.00
F10' P.U.E.
�
Note: ®Wlding Setback Lines per
� City of College Stotion Un.Ged $'
! ?C 1 Development Drdnonce 02617
' 7.5' • y $ N s.
8 ! !
20' I Lot ate, Block s99 w� I
Shenam*vh Phase 1.3
LDL 36
Nov or Formerly ley b Lei 34
Ed Freehling Builder, ll I v Now or Famurly
Vol. 6580. Pg. 214 Ed Freehling 804ar, Inc.
� E
n Vol, 0580. Pg. 71e
In A
Proposed
! Residence .�
7,e' 10.4, 20'
I I C
21.0' 7.7'
ir! � ConGYc� I
rl'i ! OYiJ�
-� In
I
.• Bcck/G�rb.�
Lf (03 Halifax ®�rva
50' R.f. !N, — 27' Havernent
Wol, $580, Pg 21 d
Aub �p
V
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\1202MV.rck
TITLE: 4103 Halifax Drive
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 11 /02/05
DATE OF PLANS: 4/8/05
PROJECT INFORMATION:
Lot 35 Block 39
Shenandoah Phase 13
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
NOTES:
New 4-Bedroom
1765 Sqft
COMPLIANCE: Passes
Maximum UA = 657
Your Home UA = 607
7.6% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.36
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame, Double Pane with Low-E
SHGC: 0.40
Bldg. faces 45 deg. from North; Comp. orient.: Front
Projection factor: 0.19
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 45 deg. from North; Comp. orient.: Left Side
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
1765
30.0
0.0
62
396
13.0
0.0
25
50
0.640 32
38 0.400 15
402 13.0 0.0 28
46 0.640 29
Projection factor: 0.27
Door 2: Glass 18 0.580 10
SHGC: 0.78
Bldg. faces 45 deg. from North; Comp. orient.: Left Side
Projection factor: 0.81
Wall 3: Wood Frame, 16" o.c. 396 13.0 0.0 21
Window 3: Metal Frame:Double Pane with Low-E 134 0.640 86
SHGC: 0.40
Bldg. faces 45 deg. from North; Comp. orient.: Back
Projection factor: 0.23
Wall 4: Wood Frame, 16" o.c. 402 13.0 0.0 32
Window 4: Metal Frame:Double Pane with Low-E 9 0.640 6
SHGC: 0.40
Bldg. faces 45 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Floor 1: Unheated 250 0.0 261
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 10 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements m RESc ion 3. elease 1b (formerly MECchec/ and to comply with the mandatory requirements listed in
the RES checkI ection Che list.
Builder/Designer