HomeMy WebLinkAboutRES2005-03899OS-35�f9
PREPARED 12/14/06, 7:47:58 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/13/06
------------------------------------------------------------------------------------------------
ADDRESS . : 1111 WAYNESBORO CT SUBDIV: SHENANDOAH PH 13
CONTRACTOR ED FROEHLING BUILDERS PHONE : (979) 776-8266
OWNER FROEHLING, EDWARD PHONE
PARCEL 569500-1337-0150
APPL NUMBER: 05-00003899 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/05/05 OC BLDG, FOUNDATION -SLAB TIME: 17:00
12/05/05 AP December 5, 2005 10:22:55 AM bkorthauer
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 2/02/06 JGM BLDG, FRAMING TIME: 17:00
2/02/06 AP T/S: 02/02/2006 08:05 AM GLSOUTH -----------------------
B130 01 2/14/06 RH BLDG, INSULATION TIME: 17:00
2/14/06 AP February 13, 2006 12:56:28 PM bkorthaue.r____
B125 01 12/13/S6BI�/� BLDG, FINAL TIME: 17:00
A6 v� December 13, 2006 12:57:55 PM kwolfe.
-=------------------------------
VP
d
PAGE-----------------------------------
1-�)e_ej /L�Xe- k-wT<— kjet'�, (d�
Kim Wolfe - Re: Calling for CO_@ 1111 Waynesboro Ct Page 1
From: Terry Boriskie
To: Benjamin McCarty; Chris Haver; Gina Southerland; Joe Garcia; Kim Wolfe; Mitchell
Carson; Nicole Cochran; Paul Schoenfeld; Terry Boriskie
Date: 12/18/2006 8:39:40 AM
Subject: Re: Calling for CO @ 1111 Waynesboro Ct
Talked to Pam with Ed Froehling and she will have the problem fixed.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Joe Garcia 12/15/2006 6:24 pm >>>
THEY NEED TO RAISE THE SEWER BOX. THERE IS A GREEN FLAG MARKING THE LOCATION OF
THE SEWER BOX. JMG
>>> Kim Wolfe 12/15/06 8:27 AM >>>
Are there any issues?
BP # 05-3899
Thanks
Kimberly Wolfe
City of College Station
Planning & Development Services
(979) 764-3570
www.cstx.gov
Date: 12/14/2006
Inspection Comments for Finals
Permit Year: 5 Permit Number: 3899
Address: 1111 WAYNESBORO CT
Insp.
Type
Inspection Type Code
Insp.
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
P100
PLBG, ROUGH IN
IC
11/30/2005 03:38 PM RH PDA
P100
PLBG, ROUGH IN
IC
Approved by Oscar.
Page 1
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning
Owner . . . . . . .
Contractor
Application number
Description of Work
Construction type
Occupancy type
Flood Zone . . . .
Approved . . .
1/02/07
569500-1337-0150
1111 WAYNESBORO CT
COLLEGE STATION TX 77845
SHENANDOAH PH 13
SHENANDOAH #13, BLOCK 37, LOT
15
SINGLE FAMILY RESIDENTIAL
FROEHLING, EDWARD
ED FROEHLING BUILDERS
979 776-8266
05-00003899 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
icia
VOID UNLESS SIGNED BY BUILDING OFFICIAL
WF0716293
001 City of Co.1lege
Station
PAGE
REQ. DATE:
11/14/05
11/14/05
14:09:5, %811&tl
LOCATION:
1111 WAYNESBORO CT
LOC ID:
201794=
REQUESTOR:
ED FROEHLING BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
1
„,
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE'
WORK TYPE:
ROU,.'
411 SWR
TAP 3/411 WTR TAP
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START: 11/14/05 SCHED
COMPLETION:
11/14/054.,
tla
JOB ORDER
RESULT COMvEENTS
3c
BUILDING PERMIT
CITY OP COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
III Yip
PHONE:
----------------------------------------------------------------------------
(979)764-3570 FAX: (979)764-3496
44"
Application Number
. . . . . 05-00003899 Date
11/14/05
Property Address
. . . . . . 1111 WAYNESBORO CT
Property ID:
569500-1337-0150
R
R301823
Application type description
RESIDENTIAL, 1 UNIT DETACHED
NEW
Subdivision Name
. . . . . . SHENANDOAH PH 13
Property Use . .
. . . . . . RESIDENTIAL
Property Zoning .
. . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 131670
Owner
Contractor
------------------
FROEHLING, EDWARD
------ ------------------------
ED FROEHLING BUILDERS
41
3887 HIGH LONESOME
ED FROEHLING
COLLEGE STATION
TX 778459443 3887 HIGH LONESOME RD
COLLEGE STATION
TX 77845
(979) 776-8266
Structure Information
000 000 SINGLE FAMILY
Construction Type
. . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type .
. . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info
. . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA
1995.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
5.00
SEWER TYPE PUBLIC
TAZ
427.00
-----------------------
Permit . . . . .
------------------------------------- ----
. BUILDING PERMIT
-----------
Additional desc
KW
Permit Fee . . .
. 556.00 Plan Check Fee
.00",
Issue Date . . .
. 11/14/05 Valuation . . . .
131670,
Expiration Date .
. 5/13/06
Qty Unit Charge
Per
Extension
BASE FEE
4 6 0. 0 0
32.00 3.0000
THOU BLDG, VAL 100001-500000
96.00i".,"
----------------------------------------------------------------------------
Special Notes and
Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
----------------
BUILDING
APPLICAN'
BUILDING PERMIT '
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496 ..,"
. �...
----------------------------------------------------------------------------
.
La"
Page 2 4u.
Application Number . . . . . 05-00003899 Date 11/14/05
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 2211
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS »
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION "
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE »
CONCENTRATION, RATE OF APPLICATION AND TREATMENT u`
M.
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY =,x>
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB -GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED INA GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES u"
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
1t,
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, '
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP �»
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC +•
If PEX water supply piping is sleeved below the slab, seal
PP Y P � P 9 .,:
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE .•.
BUILDING
APPLICANT
BUILDING PERMIT °""
CITY OF COLLEGE STATION
• ul.m
1101 TEXAS AVE
COLLEGE STATION, TX 77840
Ilr+.
PHONE: (979)764-3570 FAX: (979)764-3496
---------------------------------------------------------------------------
Page 3
Application Number . . . . . 05-00003899 Date 11/14/05,,,91,,,
-------------------------------------------------------------------------
x
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE ;lU
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED F"
1 Ww;
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE �}
MAXIMUM STATIC WATER PRESSURE TO 80 PSI "
. U.w
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
L.•
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH N.•:
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 U
DEGREES
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY ".
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE .41
TEMPERED GLASS f4"
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS "
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE n...
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
Ya.
EQUIPMENT AND A PRESSURE REDUCING VALVE w
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN .,.
PRIVATE GARAGES '
Narrow wall bracing fully sheathed
---------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due ,,.
--------------------------------------- - ---- ------------------------
BUILDING D R PR SE TATIVE: ,.
APPLIC�
._..:yew..
aiu
,.iil na
"kw'
y..
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE v
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
---------------------------------------------------------------------------a,.:,
bty.
Page 4
Application Number . . . . . 05-00003899 Date 11/14/05
---------------------------------------------------------
Permit Fee Total 556.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1306.00
BUILD
APPLI
556.00 .00
.00 .00
750.00 .00
1306.00 .00
.00
.00
.00
.00
I
t Ili uX
{�J ilia
. Ili bw
. Giou
a44lia,
. LI'Np
b.+
Y_e:
CITY OF COLLEGE STATION
Planning 6 Development'Semiat
APPLICATION FOR BUILDING PRRMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764.3570 (979) 764.3496 FAX
WWW.CSTX.GOV
ADDRESS/LOCATION: , 1 I I 1 W
IOF:
nly
DATE: `C REG
APPLICATION # i
TEMP POLE .#
COU LZT
LOT 15 ✓ BLOCK �E37 SUBDIVISION XxA}t
BUSINESS/OWNER NAME:
PHONE:�I
CONTRACTOR/HOMEOWNER: Eb FEtzOE-OU1�1C-1 13ULLL)E1P—,tt-k_pHONE: _7710-87�C4.
CONTRACTOR ADDRESS:G�-7 �) lU t-I Lyty�pl�E GS �-78�5
ELECTRICIAN: b tt 6 Q— lG PLUMBER: 'fiP_IPL—E
HVAC: JG [�AAC) r—IVE GOOD CENTS Residentialonl
c y):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION. RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR 6ESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ (31 jcv (.D .CEO TOTAL AREA: 2_ �Cpl HEATED AREA:
(Cost of Labor and Materials)
12"PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
dSEWER TAP:
WATER TAP:
Ef)
IZE
3 tt
OTHER TAP:
SIZE
TEMP POLE
SIZE
GARAGE TYPE: SINGLE El
ATTACHED
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE
kETACHED
TRIPLE'
Svc o� C
1Tl�N
CARPORT a
SIGNATURE OF APPLICANT: LC
*If proposed work involves new commelrei onstrucf n rfacade i
commercial property, building elevations are d.
Ofcial'Use Only
zo
/ Plans Examiner Zoning Official
to an existing
♦+++++++-+,+++#4++4*.++
NO
Energy Code Compliance Information
% Glazing of exterior walls
t o
Insulation R value of exterior walls
3 I
Insulation R value of ceiling 1 (flat areas)
Insulation R value of. ceiling 2 (vaulted areas/no attic)
N %A
Glazing SHGC
Glazing U-Factor
AO
R value of ductwork
CP
A/C SEER Rating
I o s �-
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
RES check Software Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\1116PM.rck
TITLE: I I I I WAYNESBORO COURT
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 11 /02/05
DATE OF PLANS: 1/10/04
PROJECT INFORMATION:
LOT 15 BLOCK 37
SHENANDOAH PHASE 13
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
3887 HIGH LONESOME ROAD
COLLEGE STATION, TX 77845
NOTES:
SMALL 5-BEDROOM
1995 SQFT
COMPLIANCE: Passes
Maximum UA = 664
Your Home UA = 538
19.0% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.38
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Front
Projection factor: 0.23
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Left Side
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
1995
30.0
0.0
70
445
15.0
0.0
26
64
0.600 38
38 0.400 15
465 15.0 0.0 33
31 0.600 19
Projection factor: 0.27
Wall 3: Wood Frame, 16" o.c. 445 15.0 0.0 28
Window 3: Metal Frame:Double Pane with Low-E 61 0.600 37
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Back
Projection factor: 0.27
Door 2: Glass 18 0.580 10
SHGC: 0.78
Bldg. faces 180 deg. from North; Comp. orient.: Back
Projection factor: 1.02
Wall 4: Wood Frame, 16" o.c. 465 15.0 0.0 34
Window 4: Metal Frame:Double Pane with Low-E 27 0.600 16
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Right Side
Projection factor: 0.27
Floor 1: Slab-On-Grade:Unheated 203 0.0 212
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 10 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release lb (formerly MECchec� and to comply with the mandatory requirements listed in
the RES checkInssectie cklist. % j
Builder/Designer ,� Date t l I Z G
:.. 21. 2vIi5 8: 1 OAIV 'vl:-C1uI-e & 'D;,,Wn2 Cnf%Su!''v'°% 1 ni .,
Y2 P,
GLl/ 'C�RONFO ' 111 �i � / '• 1G+ fs' �n•� �uirb>03•C %.�1T8Rfa/�1.�� .tB�B
Lot 15 Block 37.dwg
L't't 4 Lot 3 Lut 2
Now or Formerly Now or F rherly Ed Fro 65808qNov, or Formerly
Vol. 6f3uiEd Freehling Sunder, Inc. Ed Fro"06q4 Builder, In<.
, Pg.
�214 Inc, ( Vol. 6580, Pg. 214 Vol. 5560, Pg. 214
IN 4378'36" E " 85.00'
20' P.U.E.
e—�
_
M
"j
Note; Bullding Satbock lines per
f Collage Station Unifed
7.5
Development rdinenca #2817
B.S.
I
L�City �o
I
Scale;
II
1 20`
.••.,5
Zot JM Blwk .97
�
Shonand®ah ANve 13
Lot 14
Now or Formerly
Ed froehGng Bclidar, Inc,
Vol, 65ti0, Pg. 214
I
(
I
(
t I
lot 18
+4i♦ Now or ro,meriy
Q I Ed Froehli�g Fcifder, inc.
1`
'Vol. 6580, Pg, 214
P
Proposed
I
I
J
Residence
4q
I
I
N
I
.a
Its � I Propoeed
N 1 Driveway
I
I
I
�n
I c~v
I
l
S 4.526'38" W - 6.5.00'
_ 4' Sidewolk
Bock/Curb_ --�—
Waynesboro Court
50' R.O,W, N 27' Pavement
yo1. 6580, Pg, 214
aim
� PLAN
REVIEW
ONE and TWO FAMILY
CITY OF COLLEGE STATION
OCCUPANCY REQUIREMENTS
Planning d Dmrlopmtnt smira
PLAN REVIEW/PERMIT NUMBER#
BUILDING ADDRESS:— SF'F DATE: �i / lo/ os—
i l ►bo
I. Foundation Re uirements
A. Concrete minimum f'c of 3000 PSI N
B. Minimum four 4 Inch slab thickness
C. vapor barrier
1. 6 mil poly
D. Slab/beam or fer to out shown
1. Footin s/beams are continuous over the len th and width of foundation
2. Dimensions
3. Footin s 30" exterior, 24" interior unless over 60' lonq then 30"
4. S acingof beams does not exceed 15'
E. Reinforcement details to meet minimum re uirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Mason fire lace foundation reinforcement
F. Wood foundation details indicated
II. Framing: FloorWall, Ceiling and Roof Requirements
A. Girder or sill dimensions grade & species EN!EK
B. Floor 'oist size s acing, grade & direction of span indicted on plans
C. Treated sill Plate or bottom plate
D. Narrow Wall Ell Methods indicated on tans
E. Header sizes indicated on plans
F. Emer enc i bedroom a ress
1. Exit direct to outside M
2. O arable window
a. Twen 20 inch clear width b twen -four 24 inch clear hei ht
b. Maximum sill hei ht of fo -four 44 inches above finished floor
G. O erable bathroom window re uired when mechanical ventilation is n!2q,rovidled
H. Stud -grade and s acing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathingindicated on plans
3. Moisture barrier indicated on plans
J. Roof framin Ian or elevation shown
K. Ceiling'joist sizespacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
'I. If located In garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes s acin rade slope and urlins if required.
4"
4r.. '4
CITY OF COLLEGE STATION
Plannlnj d AvilopnvntSnvien
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
-raming: Floor, Wall, Ceiling and Roof Requirem,
0. Roof Covering
1. Roof Decking indicated on plans
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, wall;
location indicated on plans
Q. Tempered Glass required in all hazardous loc
R. Overhangs allowed on zero lot line constructs
S. Protected openings on walls < three feet iron
T. One hour tenant separation to roof deck betv
Stairway Requirements
—_ A. Stairway Details
1.
2.
3.
i riser height 7-3/4 inches
tread width 10 inches
risers are uniform 3/8" Max.
4. Stairway width not less than 36 inche
5. Stairway headroom not less that six ft
- Wmder details
1. r reads a minimum of six (6) inches of
2. Treads a minimum of ten (10) inches
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one h
2. Treads a minimum of seven and one.
inches from the narrow edge
3. Stairway width not less than twenty-s
4. Headroom required not less than six
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck
above grade or finished floor
2.
Han,
3.
Han
lead
4.
Han
stair
5.
Gus
6.
Gu2
raili
IV. Fireplace Requir
A. Hearth exti
1.
Fire
Is are required on stairways I
Is must be thirty-four to thirty
edge of the tread
Hs must not project more that
i
must be a minimum of thirty-
& handrails along open -side
or uprights that prevent the p
ants (to be indicated on pia
B. Masonry fireplace
0. Chimneys must e
least two (2) feet
g < 6 sq, ft, (extens
9 ? 6 sq. ft. (extens
as 2" clearance froi
at least three (3) fe
than any portion o-
:nos tconunuep)
ceiling & roofs must have the size, grade &
ations
on up to 18"
i property line
Teen duplexes
difference
NA/
OK
--eight 6'-8"
i narrow ed e
at a distance of twelve (12) inches from the
alf 9-1/2 inches
hair (7-1/2) inches at a distance of twelve (12)
ix inches
ft six (6,41 inches
balcony or landing is thirty (30") inches
ocated four or more risers above floor/ rade
eight (34-38) inches when measured from the
r four & one-half (4-1/2") inches into width of a
sInches above finished floor
(s) of stairway must have intermediate
assa a of a four 4 inch sphere
ns
Ions: 8" & 16' forward
Ions: 12" side & 20' forward
n all combustible materials
A higher than the highest point of roof & at
the buildingwithin ten 10 feet horizontal
F
.A
V4"
CITY OF COLLEGE STATION
Planning 6, Dewkpmm►$mien
V. Electrical Service Rent
A. Electrical plan
i. uectrical fixtures & switch
2. Smoke detector locations
3. GFI circuits indicated whe
4. Arc fault protection for bei
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
Jicated
cated as
S. Panel and Meter location
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
Vil. Mechanical Requirements
A All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside (excludes ductless units)
B. Attic installed HN.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Ener Requirements
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordin
Permitted use for district
Density requirements
Minimum lot size
On zero lot side 18" max. overhang allowed
treet Ordinance Requirements
Maximum drive width for residence is 28' (combined for circ
Minimum 20 feet from driveway to side (intersecting) street
ubdivision Regulations — Ordinance 690
Approved subdivision
Plat filed
loodplaln Regulations — Ordinance 1301
Does not block any water course or divert any flow
Elevation certificate if reaulred
.no
:shy
CITY OF COLLEGE STATION
Planning d Diwlopmenr &mira
t9:
PLANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
DATE
CITY OP COLLEGE STATION
Planning &DMkpmmr &rakt,
Storm Water Discharge Pe
Texas Pollution Discharge Elimination System General Permit NO TXR 150000,
The State of Texas assumed regulatory authority over storm water discharges associated with
construction activities, effective March 5, 2003. The regulatory requirements under the general
,permit are based upon the area of land disturbed and are classified into two categories:
Large Construction Activity: 5 or more acres of disturbed land or part of a ar er commo Ian o
development that will disturb 5 or more acres.,I a n ° f
1. Obtain a copy of TPDES GP No. TXR 150000
2. Develop and implement a Storm Water Pollution Prevention Plan
3. Two days prior to the start of construction, submit a Notice of Intent to TCEQ
4. Provide a copy of the Notice of Intent to the City
5. Submit a Notice of Termination to TCEQ once the site has reached final stabilization
Small Construction Activity: at least 1 but less than 5 acres, or is part of a larger common development that will disturb at least 1 but less than 5 acres. plan of
1. Obtain a copy of TPDES GP No. TXR 150000
2. Develop and implement a Storm Water Pollution Prevention Plan
3. Prior to starting construction, post a Construction Site Notice as in Part II.D.2 at the site
4. Provide a copy of the Construction Site Notice to the City
Additional information can be obtained from:
TCEQ Website: www.tnrcc.state.t(.us/i)Brmittina/wnfprnarm/%AAAIM erm/construct.html#additional
This website provides all associated documents and explanations including NOI, GP, etc.
Compliance assistance can be obtained from: Donnie Willis
Drainage Inspector .
City of College Station
979-764-6375
dwillis@cstx.gov
Laroer Common Plan of Development — A construction activity is part of a larger common plan of
development if it is completed in separate stages, separate phases, or in combination with'other
construction activities
Example 1: A subdivision is being built. You are grading 0.75 acres, another company is clearing 4
different acres, and a contractor is excavating another 0.5 acres. In this case, the total area that
Would be disturbed is 5.25 acres, so each contractor would fall under the requirements associated
With disturbing 5 or more acres.
Example 2: At first, your project calls for you to grade, clear, or excavate a total of 0.93 acre. But
after your project begins, you learn that you must disturb another 0.15 acre. Because this project
has grown to disturb a total of 1.08 acres, you must obtain coverage under the requirements for
disturbing 1 to less than 5 acres.