RES2005-03836, 05-3837
PREPARED 4/24/06, 12:00:00 INSPECTION TICKET PAGE 4 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/24/06 ------------------------------------------------------------------------------------------------ ADDRESS 310 ROBELMONT DR SUBDIV: EDELWEISS GARTENS PH 6 CONTRACTOR CHARLES THOMAS HOMES., INC. PHONE (979) 696-4384 OWNER EDELWEISS GARTEN VENTURE PHONE PARCEL 244030-0613-0220 APPL NUMBER: 05-00003836 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 11/14/05 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 11/14/05 AP November 14, 2005 11:42:51 AM bkorthauer Strings On Setbacks O.K. Slab Ground Installed B115 01 12/21/05 JGM BLDG, FRAMING TIME: 17:00 12/21/05 AP December 20, 2005 3:36:17 PM kwolfe B130 01 12/29/05 BH BLDG, INSULATION TIME: 17:00 12/29/05 AP January 4, 2006 10:27:39 AM kwolfe January 4, 2006 10:28:05 AM kwolfe B125 01 4/24/06 BI BLDG, FINAL TIME: 17:00 C April 24, 2006 9:53:39 AM bkorthauer -----=--- --- ��---�--/- -- COMMENTS AND NOTES -------------------------------------- . � 4� Date: 4/24/2006 Inspection Comments for Finals Permit Year: 5 Permit Number: 3836 Address: 310 ROBELMONT DR Insp. Type Inspection Type Code Insp. status Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. B100 BLDG, FOUNDATION -SLAB IC Slab Ground Installed B130 BLDG, INSULATION IC January 4, 2006 10:28:05 AM kwolfe Page 1 Brittany Korthauer - Insulation request inspection result, 310 Robelmont, 405-3836 Page 1 .11 From: Brian Henry To: Southerland, Gina Date: 1/3/2006 8:53 am Subject: Insulation request inspection result, 310 Robelmont, #05-3836 CC: ' Korthauer, Brittany; Wolfe, Kim Print for File Inspected insulation, 310 Robelmont, #05-3836, Thomas Homes, 12-29-05 Inspection result: Inspected OK for Good Cents WF0712774. / 001 City of College Station PAGE 1 REQ. DATE: 10/31/05 10/31/05-'12:09:02•�- • 4.'A" LOCATION: 310 ROBELMONT DR LOC ID: 201878., REQUESTOR: CHARLES THOMAS HOMES, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT TEMP POLE PASSED TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/31/05 SCHED COMPLETION: 10/31/05 JOB ORDER RESULT COMvMNTS WF0712100 / 001 City of College Station PAGE REQ. DATE: 10/27/05 10/27/05 14:05:26 LOCATION: 310 ROBELMONT DR LOC ID: 201878 REQUESTOR: CHARLES THOMAS HOMES, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT. 4" SWR TAP 3/4" WTR TAP TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/27/05 SCHED COMPLETION: 10/27/05 ******************************************************************************** JOB ORDER RESULT COMMENTS City of College Station 1101 TEXAS AVENUE COLLEGE STA'TI-ON-TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue, Date . . . . . . 4/25/06 Parcel Number . . . . . 244030-0613-0220 Property Address . . . 310 ROBELMONT DR COLLEGE STATION TX 77845 Subdivision Name EDELWEISS GARTENS PH 6 Legal Description . . . EDELWEISS GARTENS #6, BLOCK 13 , LOT 22 Property Zoning . . . . SINGLE FAMILY RESIDENTIAL Owner . . . . . . . . . EDELWEISS GARTEN VENTURE Contractor . . . . . . CHARLES THOMAS HOMES, INC. 979 696-4384 Application number 05-00003836 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . ... Approved . . . . . . . Bui I ing Official VOID UNLESS SIGNED BY BUILDING OFFICIAL BUILDING PERMIT CITY OF COLLEGE STATION 101 'TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 05-00003836 Date 10/27/05 Property Address . . . . . . 310 ROBELMONT DR Property ID: 244030-0613-0220 R #: R301773 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . EDELWEISS GARTENS PH 6 Property Use . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 110000 Owner Contractor ------------------------ EDELWEISS GARTEN VENTURE ------------------------ CHARLES THOMAS HOMES, INC. 311 CECILIA LOOP CHARLES THOMAS COLLEGE STATION TX 778456310 P 0 BOX 10106 COLLEGE STATION TX 77842 (979) 696-4384 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1628.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit Fee . . . . 490.00 Plan Check Fee .00 Issue Date 10/27/05 Valuation . . . . 110000 Expiration Date 4/25/06 Qty Unit Charge Per Extension BASE FEE 460.00 10.00 3.0000 THOU BLDG, VAL 100001-500000 30.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) ---------------------------------------------- BUILDING DEPT RnRESENTATIVE: -----< -- ------------------- ice+ APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 05-00003836 Page 2 Date 10/27/05 Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT'AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ------ANY CHANGES OR ALTERATIONS TO SUBMITTED S MUST BE -----------------------------------------I---------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION i101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . 05-00003836 Date 10/27/05 ---------------------------------------------------------------------------- Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN. ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES --------------------------------=----------//----.-_--------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 05-00003836 Date 10/27/05 ---------------------------------------------------------------------------- Special Notes and Comments Narrow wall bracing fully sheathed ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged Paid Credited -------------------- Due ---------- Permit Fee Total ---------- 490.00 490.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1240.00 1240.00 .00 .00 --------------------------o ----- --------------------- BUILDING DEPT R P ,ESENTATIVE`: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 05-00003837 Date 10/27/05 Property Address . . . . 310 ROBELMONT DR Property ID: 244030-0613-0220 R #: R301773 Application type description TEMP POLE Subdivision Name . . . . . . EDELWEISS GARTENS PH 6 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ EDELWEISS GARTEN VENTURE ------------------------ CHARLES THOMAS HOMES, INC. 311 CECILIA LOOP CHARLES THOMAS COLLEGE STATION TX 778456310 P 0 BOX 10106 COLLEGE STATION TX 77842 (979) 696-4384 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KW Permit Fee . . . . 20.00 Issue Date . . . . 10/27/05 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged Paid Credited Due Permit Fee Total ---------= 20.00 ------------------------------ 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ------------- BUILDING DEPT RE SENTATIVE :--� APPLICANT : '�—VE. ' - - - - - /1 - - - - - - - - - - - - - - - - - - - APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEGE-STATION.TX. US ADDREd9 � SSS/LOCATION: 01 V I\ Oil I� LOT ')/BLOCK 12) ""SUBDIVISION E BUSINESS/OWNER NAME: wr omoe use only c�— DATE: �S 0 S APPLICATION # TEMP POLE # r� O 1) piJf ---- CONTRACTOR/HOMEOWNER: CHARLES THOMAS HOMES, INC. CONTRACTOR ADDRESS: COLLEGE STATION, TX 77842 ELECTR IAN: 1<04"( CiZIL" Aw HVAC: RP41if PLUMBER: J -P 6. PHONE: PHONE: a Z. -©D4 GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION OVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION* SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL Required) it DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (rAS) PROJECT REGISTRATION//#�� EABPPRJ VALUATION: $ - ( /0' 000 TOTAL AREA: doZ<O.d' HEATED AREA: (Cost of Labor and Materials) © PUBLIC SEWER i� �SEPTIC/TREATMENT SYSTEM 135O [o SEWER TAP: �Ll1 �400 WATER TAP: A�i SIZE OTHER TAP: �5 o, SIZE i/� TEMP POLE GARAGE TYPE: SINGLE ATTACHED NUMBER OF BEDROOMS: 3 NUMBER OF BATHROOMS: INTERIOR WALL TYPE:�%��, EXTERIOR WALL TYPE: FOUNDATION TYPE: [ ROOF TYPE: C0m o 9) ty©N L eJtiR. DOUBLE d .. TRIPLE a DETACHED Q CARPORT a SIGNATURE OF APPLICANT: \' GVtX.�—� r�� j *If proposed work involves new commercial construction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Only ments: YEI or NO — F IP .� e� w/N ./�I.(f Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1(flat areas)p Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC , 35 Glazing U-Factor �p R value of ductwork A/C SEER rating CHARLES THOMAS HOMES, INC. P.O. BOX 10106 COLLEGE STATION, TX 77842 i � PLAN REVIEW ONE and TWO FAMILY CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS Planning d Dmilopment Sa viem PLAN REVIEW/PERMIT NUMBER# os- 383 DATE: /O 1�61os� BUILDING ADDRESS: 31 n � i b a _ 1 n� I. Foundation Requirements A. Concrete minimum fc of 30 00 PSI B. Minimum four (4) inch state fhinknc 1. 6 mil poly D Slab/beam or Pier layout shown I. Footin s/beams are continuous over the len th and width of fou 2. Dimensions 3. Footings (30" exterior, 24" interior unless over 60' long then 30") 4 Spacing of beams does not exceed 15' E Reinforcement details to meet minimum re uirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Mason fire lace foundation reinforcement F. Wood foundation details indicated Framing: Floor, Wall, Ceiling and Roof Requirements A. Girder or sill dimensions grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans Q. Treated sill plate or bottom plate D. Narrow Wall Bracin Methods indicated on plans E. Header sizes indicated on pl ans F. Emeraene�v hafir,,nw, 2. Operable window a. Twenty (20) inch clear width by twenty-four (24) inch clear b. Maximum sill hef ht of TO f4our 44 inches above finishea . Operable bathroom window required when mechanical ventilation is not K H Stud grade and spacing I Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3 Moisture barrier indicated on tans J. Roof framing plan or elevation shown K Ceiling joist size, spacing, grade and direction of span indicated on plans Attic access location and size indicated on plans — 1. If located in ara a it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing grade, slope and purlins if required. 0A ,y PLAN REVIEW ONE and TWO FAMILY CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS Planning d Dvilopint Sarvlcn 11. Framing: Floor, Wally Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans, 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. overhangs allowed on zero lot line construction UD to 18" S. Protected openings on walls < three feet from property line T. One hour tenant se aration to roof deck between du lexes III. Stairway Requirements A. Stairwav Details 1. Maximum riser hei ht 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairwa headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum of ten (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser hei ht less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one=half (7-1/2) inches at a distance of twelve (I 2) inches from the narrow edge 3. Stairway width not less than twen -six inches 4. Headroom required not less than six ft six W-61 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are re lulredd on stairwa s located four or. more risers above floor/ rade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading,edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thi -six 36 inches above finished floor 6. Guards & handrails along open -sides) of stairway must have intermediate railing or uprights that revent the passage of a four 4 inch sphere IV. Fireplace Requirements (to be indicated on plans) A Hearth extensions 1. Fireplace opening < 6 sq, ft, (extensions: 8" & 16" forward) 2. Fireplace o enin ! 6 s . ft. extensions: 12" side & 20" forward _ B. Masonry fireplace requires 2" clearance from all combustible materials Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two (2) feet higher than any portion of the building within ten (10) feet horizontal 1► PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OP COLLEGE STATION Planning d, Dswlop w &n1ca V. Electrical Service Requirements A Electrical plan to include. I. Electrical fixtures &switches indicated 2. Smoke detector location(s) indicated as required 3. GFI circuits indicated where required 4. Are fault protection for bedroom circuits S. Panel and Meter location VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated IS" when installed in the garage or room directly off garage y11. Mechanical Requirements A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside (excludes ductless units) B. Attic installed HN.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of a ui ment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) I. Energy Requirements A Compliance software worksheet (REScheck) submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinan for size — Ordinance On zero lot side 18" max. overhang allowed Street Ordinance Requirements Maximum drive width for residence is 28' (combined for circ Minimum 20 feet from driveway to side (intersecting) street Subdivision Regulations — Ordinance 690 Plat filed ilaln Regulations — Ordinance 1301 Does not block any water course or divert any flow Elevation certificate if required CITY OF COLLEGE STATION Planning d DmIet ont sm l ca PLANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS 41 DATE CITY OF COLLEGE STATION Pbmniq d, Drwkpmme &tvk , torm Water Discharge Permit Texas Pollution Discharge Elimination System General Permit NO TXR 150000, The State of Texas assumed regulatory authority over storm water discharges associated with construction activities, effective March 5, 2003. The regulatory requirements under the general .permit are based upon the area of land disturbed and are classified into two categories: Large Construction Activity: 5 or more acres of disturbed land or part of a larger common Ian o development that will disturb 5 or more acres. f 1.Obtain a copy of TPDES GP No. TXR 150000 2. Develop and implement a Storm Water Pollution Prevention Plan 3. Two days prior to the start of construction, submit a Notice of Intent to TCEQ 4. Provide a copy of the Notice of Intent to the City 5. Submit a Notice of Termination to TCEQ once the site has reached final stabilization Small Construction Activity: at least 1 but less than 5 acres, or is part of a larger common plan of development that will disturb at least 1 but less than 5 acres. 1.Obtain a copy of TPDES GP No. TXR 150000 2. Develop and implement a Storm Water Pollution Prevention Plan 3. Prior to starting construction, post a Construction Site Notice as in Part II.D.2 at the site 4. Provide a copy of the Construction Site Notice to the City Additional information can be obtained from: TCEQ Website: www.tnrcc.state.tx.us/permitting/ atererm/ww erm/construct.htmI#additional This website provides all associated documents and explanations including NOI, GP, etc. Compliance assistance can be obtained from: Donnie Willis Drainage Inspector City of College Station 979-764-6375 dwillls@cstx.gov Larder Common Plan of Development — A construction activity is part of a larger common plan of development if it. is completed in separate stages, separate phases, or in combination wlth'other construction activities Example 1: A subdivision is being built. You are grading 0.75 acres, another company is clearing 4 different acres, and a contractor is excavating another 0.5 acres. In this case, the total area that would be disturbed is 5.25 acres, so each contractor would fall under the requirements associated with disturbing 5 or more acres. Example 2: At first, your project calls for you to grade, clear, or excavate a total of 0.93 acre. But after your project begins, you learn that you must disturb another 0.15 acre. Because this project has grown to disturb a total of 1.08 acres, you must obtain coverage under the requirements for disturbing 1 to less than 5 acres. MECcheck Compliance Report 2000 IECC MECcheck Software Version 3.2 Release lb TITLE: College Station Building Permits CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 10/24/05 DATE OF PLANS: 10/25/2005 PROJECT INFORMATION: 310 Roblemont Drive COMPANY INFORMATION: Charles Thomas Homes, Inc COMPLIANCE: Passes Maximum UA = 739 Your Home = 515 30.3% Better Than Code Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E Door 1: Solid Door 2: Solid Door 3: Glass Slab 1: Unheated, 0.0' insul. Air Conditioner 1: Electric Central Air, 14 SEER Furnace 1: Forced Hot Air, 80 AFUE Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor- UA 1628 0.0 30.0 50 1696 13.0 0.0 121 167 0.640 107 20 0.013 0 18 0.013 0 18 0.440 8 220 0.0 229 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requiremen in MECcheck Version 3.2 Release lb. Builder/Designer