TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 11/08/05 OC BLDG, FOUNDATION -SLAB TIME: 17:00
11/08/05 AP November 8, 2005 8:08:54 AM kwolfe
late afternoon
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 12/05/05 OC BLDG, FRAMING TIME: 17:00
12/05/05 AP December 5, 2005 9:10:42 AM kwolfe
B130 01 12/06/05 BH BLDG, INSULATION TIME: 17:00
12/06/05 AP December 6, 2005 4:31:43 PM kwolfe
December 6, 2005 4:32:16 PM kwolfe
B125 01 2/17/06 I BLDG, FINAL TIME: 17:00
a "17-&'b February 17, 2006 8 :59 :23 AM kwolfe
-------------------------------------- COMMENTS AND NOTES--------------------------------------
�a�
Date: 2/17/2006
Inspection Comments for Finals
Permit Year: 5 Permit Number: 3834
Address: 3801 RANSBERG CT
Type
Inspection Type Code
Sixtus
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B130
BLDG, INSULATION
IC
December 6, 2005 4:32:16 PM kwolfe
Page 1
Kim Wolfe - Insulation request inspection result. 3801 Ransberg, #05-3834 Page 1
From: Brian Henry
To: Southerland, Gina
Date: 12/6/2005 4:20:52 PM
Subject: Insulation request inspection result, 3801 Ransberg, #05-3834
Print for file
Inspected insulation, 3801 Ransberg, #05-3834, Thomas Homes
12-6-05
Inspection result: Inspected OK for Good Cents
CC: Korthauer, Brittany; Wolfe, Kim
WF0712776 /
001 City of College
Station
PAGE 1
REQ. DATE:
10/31/05
10/31/05
12:11:14"".
LOCATION:
3801 RANSBERG CT
LOC ID:
201894..'.
REQUESTOR:
CHARLES THOMAS HOMES, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
TEMP POLE
PASSED
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
10/31/05 SCHED
COMPLETION:
10/31/05
********************************************************************************
JOB ORDER RESULT COMMENTS
rr3��s�
0
WF0712110 / 001 City of College Station PAGE
REQ. DATE:
10/27/05
10/27/05
14:21:49
LOCATION:
3801 RANSBERG CT
LOC ID:
201894
REQUESTOR:
CHARLES THOMAS HOMES, INC ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
4" SWR TAP
3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
10/27/05 SCHED COMPLETION:
.10/27/05
JOB ORDER RESULT COMMENTS
BUILDING PERMIT
CITY OF COLLEGE STATION
• 1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570. FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 05-00003834 Date 10/27/05
Property Address . . . . . . 3801 RANSBERG CT
Property ID: 244030-0613-0010
R #: R301752
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . EDELWEISS GARTENS PH 6
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . TOWNHOUSE
Application valuation . . . . 100000
Owner
Contractor
------------------------
EDELWEISS GARTEN VENTURE
------------------------
CHARLES THOMAS HOMES, INC.
311 CECILIA LOOP
CHARLES THOMAS
COLLEGE STATION
TX 778456310 P 0 BOX 10106
COLLEGE STATION
TX 77842
(979) 696-4384
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1504.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc
KW
Permit Fee . . . .
460.00 Plan Check Fee
.00
Issue Date . .
10/27/05 Valuation . .
. . 100000
Expiration Date
4/25/06
Qty Unit Charge
Per
Extension
BASE FEE
260.00
50.00 4.0000
THOU BLDG, VAL 50001-100000
200.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
.INTERRUPTER(S)
------------------
BUILDING D
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 05-00003834 Date 10/27/05
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
------------- - - - - - -
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 05-00003834 Date 10/27/05
----------------------------------------------------------------------------
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND. RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL•BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
---------------------------------------------.� 11---_-_4'---------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number
. . . . .
.05-00003834
Date
10/27/05
----------------------------------------------------------------------------
Special Notes and
Comments
Narrow wall bracing
fully sheathed
with interior
anchoring
and bracing
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
Due
Permit Fee Total
460.00
--------------------
460.00
----------
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1210.00
1210.00
.00
.00
-------------------
BUILDING DI
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 05-00003835 Date 10/27/05
Property Address . . . . . . 3801 RANSBERG CT
Property ID: 244030-0613-0010
R #: R301752
Application type description TEMP POLE
Subdivision Name . . . . . . EDELWEISS GARTENS PH 6
.Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . TOWNHOUSE
Application valuation . . . . 0
Owner
Contractor
------------------------
EDELWEISS GARTEN
VENTURE
------------------------
CHARLES THOMAS HOMES,
INC.
311 CECILIA LOOP
CHARLES THOMAS
COLLEGE STATION
TX 778456310
P 0 BOX 10106
COLLEGE STATION
TX 77842
(979) 696-4384
----------------------------------------------------------------------------
Permit. . . . . .
. TEMP POLE
PERMIT
Additional desc .
. KW
Permit Fee . . .
. 20.00
Issue Date . . .
. 10/27/05
Valuation . . . .
0
----------------------------------------------------------------------------
'Fee summary
-----------------
Charged
Paid Credited
Due
Permit Fee Total
----------
20.00
------------------------------
20.00 .00
.00
Grand Total
20.00
20.00 .00
..00
-----------------
BUILDING
APPLICANT
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
ADDRESS/LOCATION: j06V I
LOT r BLOCK SUBDIVISION
BUSINESS/OWNER NAME:
CONTRACTOR/HOMEOWNER:
CONTRACTOR ADDRESS:
ELECTRICIAN: Na
0
HVAC:
For Office Use Only
DATE: V6 xl os
APPLICATION #
TEMP POLE # / J�fy cam✓
v
PHONE:
CHMES THOMAS HOMES, INC-PHONE: Z Z9- DOCo�}
E STATION. TX
111%"4_x_
-% — ` KAtPLUMBER:
Eei_ _ GPOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION' OVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL
Required) I
DESCRIPTION OF WORK:
STRUCTURE USE:
HOMEOWNER ASSOC IATION/ARC HITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: _T'E5
TEXAS ACCESSIBILITY/�STANDARD (TAS) PROJECT REGISTRATION#EABPRJ
--- VALUATION: $ V O 000 TOTAL AREA.2/ 0 HEATED AREA:
(Cost of Labor and Materials)
PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
3�v dSEWER TAP: II
3 IZE
tAv l7�
WATER TAP: 4_
SIZE
OTHER TAP:
45 � SIZE
TEMP POLE
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:�'�LG.T�QIpL
EXTERIOR WALL TYPE: bela
FOUNDATION TYPE:�016
ROOF TYPE:
GARAGE TYPE: SINGLE 71, DOUBLE
ATTACHED I V I DETACHED
SIGNATURE OF APPLICANT:
ETRIPLE
a CARPORT a
♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦
Official Use Only
m ents:
rN0
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
, Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
LAB
L 13- EJF-( WFlk'ss 6'arfme, 4-3
38oi 2.-As6�-
V 'I c,-T o K'l \ Av c
-9
---ocl
cz
Q�is,4 15o4-
CHARLES THOMAS HOMES, INC
P.O. BOX 10106
COLLEGE STATION, TX 77842
Scz\T, i81-%=z6
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.2 Release lb
TITLE: College Station Building Permits
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 10/24/05
DATE OF PLANS: 10/25/2005
PROJECT INFORMATION:
3801 Ransberg Ct - Edlws Grtns-Phs 6
COMPANY INFORMATION:
Charles Thomas Homes, Inc.
COMPLIANCE: Passes
Maximum UA = 730
Your Home = 534
26.8% Better Than Code
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame, Double Pane with Low-E
Door 1: Solid
Door 2: Solid
Door 3: Glass
Slab 1: Unheated, 0.0' insul.
Air Conditioner 1: Electric Central Air, 13 SEER
Furnace 1: Forced Hot Air, 80 AFUE
Permit Number
Checked By/Date
Gross
Glazing
Area or. Cavity
Cont.
or Door
Perimeter R-Value
R-Value
U-Factor
UA
1504 0.0
30.0
47
1696 13.0
0.0
121
167
0.640
107
20
0.130
3
17
0.130
2
17
0.440
7
237
0.0
247
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building
plans, specifications, and other calculations submitted with the permit application. The proposed building has
been designed to t e 2000 IECC require in MECcheck Version 3.2 Release lb.
Builder/Designe d--� Date (� Z47—vo5-
� PLAN REVIEW
ONE and TWO FAMILY
CITY OF COLLEGE STATION • OCCUPANCY REQUIREMENTS
honninr d Dnalopment smicu
PLAN REVIEW/PERMIT NUMBER# 3 EDDBUILDING ADDRESS:��TE: io 1�61 �S
I. Foundation Requirements
A. Concrete minimum f'c of 3000 PSI N
B. Minimum four 4 inch slab thickness
C. vapor barrier
1. 6 mil D01V
D. Slab/beam or ier layout shown
1. Footin s/beams are continuous over the length and width of foundation
2. Dimensions i
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. S[?acing of beams does not exceed 15,
E. Reinforcement details to meet minimum re uirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fire lace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor Wall, Ceilin and Roof Re uirements
A. Girder or sill dimensions rade & species
B. Floor 'oist size, sDC1!2tgqrade & direction of s an indicted on tans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracin Methods indicated on plans
E. Header sizes indicated on tans
F. Emergency bedroom egress
1. Exit direct to outside
2. Onerabla winrle%—
a. l went_ (20) inch clear width by twenty-four (24) inch clear height
b. Maximum sill height of fo -four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provide
H. Stud grade and spacing
I. Exterior wall details
1. Exterior wall coveringindicated on plans
2. Sheathi i indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing plan or elevation shown
K. Ceiling foist size, spacing, grade and direction of span indicated on plans
L.. Attic access location and size indicated on plans
I. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
't.A
47.
CITY OF COLLEGE STATION
Plannfnj d Dovolopmone Soviets
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
11. Framing: Floor, Wall, Ceiling and Roof Requirem
O. Roof Covering
1. Roof Decking indicated on plans
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, wall
location indicated on plans
Q. Tempered Glass required in all hazardous loc
R. Overhangs allowed on zero lot line construct!
S. Protected openings on walls < three feet fror
T. One hour tenant separation to roof deck bete
III. Stairway Requirements
A. Stairway Details
-1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max
4. Stairway width not less than 36 inche
5. Stairwav headroom not less that six P
B. Winder details
C.
1. Treads a minimum of six (6) inches o
2. Treads a minimum of ten (10) inches
narrow edge
al stairway details
1. Riser hei ht less than nine and one4
2. Treads a minimum of seven and one
inches from the narrow edqe
3. Stairway width not less than twenty-
4. Headroom required not less than six
5. All treads must be !dent' i
IV. Fireplace
A. He
1.
2.
3.
4.
ica
I! details
required when a porch, deck
rade or finished floor
Is are required on stairways
Is must be thirty-four to thirty
edge of the tread
Is must not project more that
l
5. Guards must be a minimum of thirty
6. Guards & handrails along open -side
railing or uprights that prevent the i;
Requirements (to be indicated on ply
I. Fireplace opening < 6 sq, ft, (extene
2. Fireplace opening > 6 sq.-ft. (extern
B. Masonry fireplace requires 2' clearance froi
0. Chimneys must extend at least three (3) fe
least two (2) feet higher than any portion o
mm jconvmueo)
N
i, ceiling & roofs must have the size, grade &
ations
on UD to 18"
i property line
teen duplexes
OK
difference
ei ht 6'-8"
i narrow ed e
at a distance of twelve (12) inches from the
alf 9-1 /2 inches
half (7-1/2) inches at a distance of twelve (12)
ix inches
ft six 6'-6" inches -----------------
�
balcony or landing is thirty (30") inches
ocated four or more risers above floor/grade
-eight (34-38) inches when measured from the
I four & one-half (4-1/2") inches into width of a
six 36 inches above finished floor
(s) of stairway must have intermediate
assa a of a four 4 inch s here
ns)
N
Ions: 8' & 16" forward
Ions: 12" side & 20' forward
n all combustible materials
M higher than the highest point of roof & at
the buil ding within ten 10 feet horizontal
PLAN REVIEW
ONE and TWO FAMILY
CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS
Planning 6- Diwlopram►&n1ca
V. Electrical Service Requirements
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Are fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Re uirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed HN.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Ener y Requirements
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window )-values,
etc.)
Zonin Ordinance Requirements — Ordinance 850
Permitted use for district
Density re uirements
Minimum lot size
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
Maximum drive width for residence is 28' (combined for
Minimum 20 feet from driveway to side (intersecting) sti
Subdivision Regulations — Ordinance 690
Approved subdivision --
Plat filed
Floodplain Regulations — Ordinance 1301
Does not block any water course or divert any flow
Elevation certlficate if reaulred
0
9�
CM OF COLLEGE STATION
Planning d &w1op tnt $mica
i
PLANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
DATE
CITY OP COLLEGE STATION
Pknmiq &D"1QMme &tvkv,
rm Water Discharge Permit
Texas Pollution Discharge Elimination System General Permit NO TXR 150000,
construction activities, effective March 5, 2003. The regulatoThe State of Texas assumed regulatory authority over storm water discharges associated with
ry requirements under the general
.permit are based upon the area of land disturbed and are classified into two categories:
Large Construction Activity: 5 or more acres of disturbed land or part of a lamer common an of
development that will disturb 5 or more acres.
1.Obtain a copy of TPDES GP No. TXR 150000
2. Develop and implement a Storm Water Pollution Prevention Plan
3. Two days prior to the start of construction, submit a Notice of Intent to TCEQ
4. Provide a copy of the Notice of Intent to the City
5. Submit a Notice of Termination to TCEQ once the site has reached final stabilization
Small Construction Activity: at least 1 but less than 5 acres, or is part of a larger common development that will disturb at least 1 but less than 5 acres. plan of
1. Obtain a copy of TPDES GP No. TXR 150000
2. Develop and implement a Storm Water Pollution Prevention Plan
3. Prior to starting construction, post a Construction Site Notice as in Part II.D.2 at the site
4. Provide a copy of the Construction Site Notice to the City
Additional information can be obtained from:
TCEQ Website: www.tnrcc.state.tx.us/ ermittin /water erm/ww erm/construct.html#additional
This website provides all associated documents and explanations including N01, GP, etc.
Compliance assistance can be obtained from: Donnie Willis
Drainage Inspector
City of College Station
979-764-6375
dwillls@cstx.gov
Larger Common Plan of Development — A construction activity is part of a larger common plan of
development if it. is completed in separate stages, separate phases, or in combination with other
construction activities
Example 1: A subdivision is being built. You are grading 0.75 acres, another company is clearing 4
different acres, and a contractor is excavating another 0.5 acres. In this case, the total area that
would be disturbed is 5.25 acres, so each contractor would fall under the requirements associated
with disturbing 5 or more acres.
Example 2: At first, your project calls for you to grade, clear, or excavate a total of 0.93 acre. But
after your project begins, you learn that you must disturb another 0.15 acre. Because this project
has grown to disturb a total of 1.08 acres, you must obtain coverage under the requirements for
disturbing 1 to less than 5 acres.