HomeMy WebLinkAboutRES2005-03804, 05-4151PREPARED
4/11/06, 7:55:35
INSPECTION TICKET PAGE
12
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE
4/11/06
------------------------------------------------------------------------------------------------
ADDRESS
. : 2000 OLD MAY CT
SUBDIV: WILLIAMS CREEK PH 2
CONTRACTOR MARIOTT HOMES INC
PHONE (979) 696-1787
OWNER .
.
PHONE
PARCEL .
. 660050-0204-0060
APPL NUMBER: 05-00003804 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
11/01/05 OC
BLDG, FOUNDATION -SLAB TIME: 17:00
11/01/05 AP
T/S: 10/31/2005 11:37 AM GLSOUTH -----------------------
tuesday morning 229-0414
Strings On Setbacks O.K.
Slab Ground Installed
B115 02
12/21/05 OC
BLDG, FRAMING TIME: 17:00
12/21/05 AP
December 21, 2005 9:18:49 AM bkorthauer
B130 01
12/22/05 OC
BLDG, INSULATION TIME: 17:00
12 AP
December 22, 2005 9:51:56 AM kwolfe
B125 01
4 1/06 BI ppq�
/�JTI
BLDG, FINAL TIME: 17:00
T/S: 04/10/2006 10:16 AM GLSOUTH -----------------------
morning
--------------------------------------
COMMENTS AND NOTES-----%-�------------/----------------------
-,���'��
WF073749.7 / 001 City of College Station
PAGE 1
REQ. DATE:
01/09/06
01/09/06
12:21:34
LOCATION:
2000 OLD MAY CT
LOC ID:
202164
REQUESTOR:
MARIOTT HOMES ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
GLSOUTH AUTH. USER: GLSOUTH
WORK TYPE:
ROUT
TEMP POLE
PASSED
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
01/09/06 SCHED COMPLETION:
01/09/06
********************************************************************************
JOB ORDER RESULT COMNIENTTS
WF0711640 /
001 City of College
Station
PAGE 1
,. _A
REQ. DATE:
10/25/05
10/25/05
16:48:26
LOCATION:
2000 OLD MAY CT
LOC ID:
202164
REQUESTOR:
MARIOTT HOMES INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
10/25/0.5 SCHED
COMPLETION:
10/25/05
********************************************************************************
JOB ORDER RESULT COM UKNTS
03/01/2006 13:24 FAX 823 2275 BRAZOS CTY R ALTH 003
bS-370`
Brazos County Health Depaftent
20.1 North Texas Ave.
" Bryan, Tx 77803.6317
(979):.361.4440
LICENSE TO OPERATE AN .ON SITE SEWAGE FACILITY
THIS IS TO CERTIFY Mat the on site sewage facility owned by: OSSF #: 2006 -1038
MERRELL, ROBERT O.
OLD MAY CT. 2000. College Station TX 77845 Grid:
WILLIAMS CREEK
Block: 4 Lot: 6 Certificate of Compliance: IN C.S.
Installed By: HEATH, JAMES - HEATH'S BACKHOE SERVICE
Engineered By: PICKENS ENVIRONMENTAL SERVICE
Date Purchased:-02127/06 Fm Inspedon (Fate: 02/28/06
Disinfectant: Chlorine
Bedrooms: 3
Employees: 0
MaxGPD; 307
The private sewage.facility licensed above was installed -according to the current and
minimum guidelines of the Texas Commission on Environmental Quality (TCEQ) and
Brazos County.
This aerobic MOM withspray dis= (.requires a disinfectant for final treatment of the
sprayed effluent It is the responsibility, of the homeowner to monitor the disinfectant
and to add more when needed. (Swimming pool chlorine •tablets are not acceptable
substitutes).,: Under no circumstance are any food crops or edible foods to be grown in
the spray area. Mowing of the sprayfield on a regular basis should also be done to help
with the evaporation process.
The current maintenance contract for this system will expire 2-years from the above final
inspection date. A new maintenance contrad. must be in force at that time, and a copy of
the new contract filed with this. office Wdays before contract expires.
This is a NON-MANSFERABLE license. Upon transfer of ownership, the new owner
shall be required to transfer the`origival license into: hisTher name. Should the system
malfmiction in'the future, it will be the licensee's resp61*bility to bring the system in
compliance with allcurrent state and county: regulat 0M:
This license does not extend to the material's, workmanship, or fabrication, of the
system"so.as to expressly or impliedly grant the owner,.or installcr of the system any
warranty by/ or rights against Brazos County and / .or the Brazos County Health
Department, as to the quality. or durability of the. system, nor compliance with licensee's
individual specifications and requirements, but solely relates to the system meeting the
requirements of the above'named regulatory body in effect as of this date.
For psopar avapwatlon In the old au 3 must ba daarod ba at least i 93 foot radlus from the j!N&es s ay area.
R-10
Environmental Heap SpwlaMt
BUILDING,DERMIT
CITY OF 66LLEGE STATION
'1101 'TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 05-00003804 Date 10/25/05
Property Address . . . . . . 2000 OLD MAY.CT
Property ID: 660050-0204-0060
R ##: R****
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . WILLIAMS CREEK PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 225420
Owner
------------------------
Contractor
------------------------
MARIOTT HOMES INC
LARRY MARIOTT
209 ROCK PRAIRIE
RD
COLLEGE STATION
-TX 77845
(979) 696-1787
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2652.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
SEPTIC
TAZ
329.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc
KW
Permit Fee . . . .
838.00 Plan Check Fee
.00
Issue Date . . . .
10/25/05 Valuation . .
. . 225420
Expiration Date
4/23/06
Qty Unit Charge
Per
Extension
BASE FEE
460.00
126.00 3.0000
THOU BLDG, VAL 100001-500000
378.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
--------------------------- - ----------------------------
BUILDING DEPT REPRESENTATIVF�. cyt4 -
APPLICANT:
BUILDING-DERMIT
CITY OF COLLEGE STATION
'1101 'TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 05-00003804 Date 10/25/05
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
OBTAIN HEALTH DEPARTMENT APPROVAL: CALL 979-361-4440 FOR
MORE INFORMATION. SEPTIC SYSTEMS INSTALLED
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
THE MAXIMUM ALLOWABLE DRIVEWAY WIDTH MEASURED AT THE
PROPERTY LINE IS 28'
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
---------------------------- ----------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
.1101 'TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 05-00003804 Date 10/25/05
----------------------------------------------------------------------------
Special Notes and Comments
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE -
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
12" culvert required
Mi
nimum finished floor for sewer is 278'
-Lot
served by CSU
Narrow wall bracing fully sheathed
----------------------------�JC�--- ---- ----------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING .PERMIT
CITY OF.COLLEGE.STATION
1101'TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number
. . . . .
05-00003804
Date 10/25/05
--------------------------------------------=-------------------------------
Other Fees . . .
. . . . . .
=
WATER TAP 3/4"
400.00
------------------------------
Fee summary
-----------------
---------------------------------------------
Charged
Paid Credited
Due
Permit Fee Total
----------
838.00
--------------------
838.00
.00
----------
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
400.00
400.00
.00
.00
Grand Total
1238.00
1238.00
.00
.00
----------------------------------------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY PQLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 05-00004151 Date 12/06/05
Property Address . . . . . . 2000 OLD MAY CT
Property ID: 660050-0204-0060
R #: R****
Application type description TEMP POLE
Subdivision Name . . . . . . WILLIAMS CREEK PH 2
Property Use . . . . . . . . RESIDENTIAL -
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
MARIOTT HOMES INC
LARRY MARIOTT
209 ROCK PRAIRIE RD
COLLEGE STATION
TX 77845
(979) 696-1787
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. BK
Permit Fee . . .
. 20.00
Issue Date . . .
. 12/06/05
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
------------------------------
Due
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
L
a
------------------------------------------- ----- - -----------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: „/,.- ,."/ . � A/?z/' -5 i/=, v
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning 6 Development Services WWW.CSTX.GOV
ADDRESS/LOCATION:
(J
LOT v BLOCK SUBDIVISION
BUSINESS/OWNER NAME:
For Office jkw Only
DATE: ImI RCC REG
APPLICATION # I;�/ 5— 3"()
TEMP POLE #
r
SEC/PH /
PHONE: ZZ 7 - ii19
CONTRACTOR/HOMEOWNER: /QIQ/0T",pi
�jl �S u If—
PHONE: (elG-J7
CONTRACTOR ADDRESS: 2D
D9 l� 0 iik
pl-y I r,► t R)
C.1 -T< 7 -1 Q4s-,
ELECTRICIAN: t 14 u,J �,. PLUMBER: / o M L $e n e d 00/web
HVAC: 51 e-4 e GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL
Required)
DESCRIPTION OF WORK:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ Z2sl? t% TOTAL AREA: 3 2.2 HEATED AREA: ZGS2_-
(Cost of Labor and Materials)
❑ PUBLIC SEWER
YSEPTIC/TREATMENT SYSTEM
c
SEWER TAP: &::TC (Z-
SIZZE ✓/ n
WATER TAP: !
SIZE
OTHER TAP:
VTEMP POLE
GARAGE TYPE:
SIZE
SINGLE 71
ATTACHED I - I
NUMBER OF BEDROOMS: 3
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE Ef TRIPLE
DETACHED F__] CARPORT
�0m�
SIGNATURE OF APPLICANT: `-f ,-
*If proposed work involves new comm rci c nstruct' n or facade improvements/renovations to an existing
commercial property, building elevatio are quire
Official Use Only
740- /D -;1 y,b.S'
F%� Plans Examiner
G
r Soh
zoning Official
r►�) skajd
ents:
YES r NO
Energy Code Compliance Information
% Glazing of exterior walls 16. -� ✓
Insulation R value of exterior walls 17
Insulation R value of ceiling 1 (flat areas) 3 0
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor S ✓
R value of ductwork
A/C SEER Rating (2- ✓
09
41
� PLAN
REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planninj d Dadopment Savica
PLAN REVIEW/PERMIT NUMBER# fl� „ 3 g D
BUILDING ADDRESS:
ATE: ja
oa �
,
i. Foundatinn Ramdre.,,e. 6-
A, concrete minimum f'c of 30 10 PSI
B. Minimum four 4 Inch slab thickness
C. Va or barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footin s/beams are continu
2. Dimensions "is over the length and width of foundation
3. Footin s 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Mason fireplace foundation reinforcement
F. Wood foundation details indicated
Il. Framin : Floor all o
WCeilin and Rof Re uirements
A. Girder or sill dimensions gra&el species
B. Floor 'oist sizespacing, grade &direction of s an indicted on tans
C. Treated sill Plate or bottom plate
D. Narrow Wall —Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emeencbedroom a ress
1. Exit direct to outside
2. Operable wineinw
a. Twenty (20) inch clear width by twentyfour (24) inch clear
b. Maximum sill hei ht of fo -four 44 inches above finishes
G. Operable bathroom window required when mechanical ventilation is not
H. Stud grade and spacing
I Exterior wall details
1. Exterior wall coverin2 Indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on laps —
J. Roof framing plan or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plan;
L. Attic access location and size indicated on plans
.. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and pudins if required.
by
,4-
CITY OF COLLEGE STATION
Planning d Developmtntsavltn
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
Framing: Floor, Wall, Ceiling and Roof Requirem
O. Roof Covering
1. Roof Decking indicated on plans
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, wall
location indicated on plans
Q. Tempered Glass required in all hazardous lo,
R. Overhangs allowed on zero lot line cnnctn ir.i
S. Protected openings on walls < three feet froi
T. One hour tenant separation to roof deck bets
irway Requirements
A. Stairway Details
1. Maximum riser
2. Minimum tread
3. Sta
4. Sta
5. Sta
13. Winder details
helaht 7-3/4 inches
width 10 inches
are uniform 3/8" Max.
not less than 36 inche
headroom not less that six I
I. .-"wvg pplipilliluili ur six to) incnes c
2. Treads a minimum of ten (10) inche:
narrow edge
ai stairw
1. Riser
details
sight less than nine and oni
L. 1 reaas a minimum of seven and one
inches from the narrow edge
3. Stairway width not less than twenty
4. Headroom required not less than six
5. All treads must be identical
). Guards/handrail details
1. Guards required when a porch, decl
above grade or finished floor
2. Handrails are required on stairways
3. Handrails must be thirty-four to thirt}
leading edge of the tread
4. Handrails must not project more tha
stairwav
5. Guards must be a minimum of thirty
6. Guards & handrails along open -side
_ railing or uprights that prevent the i
Dplace Requirements (to be Indlcated on ply
A. Hearth extensions
1. Fireplace opening < 6 sq, ft. (eaten,
_ 2. Fireplace opening > 6 sq. ft. (extern
B. Masonry fireplace requires 2" clearance fro
G. Chimneys must extend at least three (3) fe
least two (2) feet higher than any portion c
volts %conunueal
N
s, ceiling & roofs must have the size, grade &
rations
ion u to 18"
n property line
veen du lexes
OK
difference
s
E. eight 6'4"
n narrow edge
at a distance of twelve (12) inches from the
lalf 9-1/2 inches
=half (7-1/2) inches at a distance of twelve (12)
six inches
ft six 6'-6" inches
balcony or landing is thirty (30") inches
located four or more risers above floor/ rade
I
-eight (34-38) inches when measured from the
I four & one-half (4-1/2") inches into width of
a
-six 36 inches above finished floor
(s) of stairway must have intermediate
Kassa Is of a four 4 inch sphere
ins
Nam,
,ions: 8" & 16" forward
�fons: 12" side & 20" forward
m all combustible materials
et higher than the highest point of roof & at
f the building within ten 10 feet horizontal
1k
FA
CITY OF COLLEGE STATION
Pfannlnd t+ Dtw1opmmt&n1ca
V. Electrical Service Requirements
A. Electrical elan to (nnh trio.
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
2. Smoke detector location(s) indicated as required
I GFI circuits indicated where required
4. Are fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided
D. Water heaters elevated 18" when installed in the garage or room directly off garage
Vll. Mechanical Requirements
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside (excludes ductless units)
B,. Attic installed RV.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
A. Compliance software worksheet (REScheck) submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window
etc.)
Zoning Ordinance Requirements — Ordinance 850
Permitted use for district
E
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
Maximum drive width for residence is 28' (combined for circ
Minimum 20 feet from driveway to side (intersecting) street
Subdivision Regulations — Ordinance 690
Plat
�l�yu pain rce uiations —Ordinance 1301
Does not block any water course or divert any flow
Elevation certfficate If required
CM OF COLLEGE STATION
planning ti Dtwlopmtnt &rvlra
Comments:
PLANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
/o z Lf—tc�--
DATE
CITY OF COLLEGE STATION
PlaWniq &Dnvkpmmr &tvkw
orm Water Discharge P
Texas Pollution Discharge Elimination System General Permit NO TXR 150000,
The State of Texas assumed regulatory authority over storm water discharges associated with
construction activities, effective March 5, 2003. The regulatory requirements under the general
.permit are based upon the area of land disturbed and are classified into two categories:
Large Construction Activity: 5 or more acres of disturbed land or part of a larger common Ian of
development that will disturb 5 or more acres.,
1. Obtain a copy of TPDES GP No. TXR 150000
2. Develop and Implement a Storm Water Pollution Prevention Plan
3. Two days prior to the start of construction, submit a Notice of Intent to TCEQ
4. Provide a copy of the Notice of Intent to the City
5. Submit a Notice of Termination to TCEQ once the site has reached final stabilization
Small Construction Activity: at least 1 but less than 5 acres, or is part of a larger common plan of
development that will disturb at least 1 but less than 5 acres.
1.Obtain a copy of TPDES GP No. TXR 150000
2. Develop and implement a Storm Water Pollution Prevention Plan
3. Prior to starting construction, post a Construction Site Notice as in Part II.D.2 at the site
4. Provide a copy of the Construction Site Notice to the City
Additional information can be obtained from:
TCEQ Website: www.tnrcc.slate.tx.us/ ermittin /water erm/ww erm/construct.html#additional
This website provides all associated documents and explanations including NOI, GP, etc.
Compliance assistance can be obtained from: Donnie Willis
Drainage Inspector .
City of College Station
979-764-6375
dwillis@cstx.gov
Larger Common Plan of Development A construction activity is part of a larger common plan of
development if it. is completed in separate stages, separate phases, or in combination with other
construction activities
Example 1: A subdivision is being built. You are grading 0.75 acres, another company is clearing 4
different acres, and a contractor is excavating another 0.5 acres. in this case, the total area that
would be disturbed is 5.25 acres, so each contractor would fall under the requirements associated
with disturbing 5 or more acres.
Example 2: At first, your project calls for you to grade, clear, or excavate a total of 0.93 acre. But
after your project begins, you learn that you must disturb another 0.15 acre. Because this project
has grown to disturb a total of 1.08 acres, you must obtain coverage under the requirements for
disturbing 1 to less than 5 acres.
PROPERT LINE 0� OJ
B-5 7' 42'05"E
/ IOA' SLOPE
EASEMENT
I
N
:=50.00'
Lul
"I_
NI
pL ZI �I
I I I / �I
C-1 I r ---J—
L0PP
PTY LINE:
_ - -
?" 567V N 83°I7'33" W \G
58' -10"
6o,
20q' -10"
PROPERTY LINE: 302.08' - 5 83'25'46" E
-- --
--
�
------------------------------------------
5�0' PUBLIC UTILITY EASEMENT
----------r-
_
----
---------
Or UILDING SEiBA�.IC LINE�
---------�'�t'
1:�.
�
wI
I
I
Iq
V
Uj
lui
Z
i
InI IJ
of
r
--^
�
2U.0 UBLIC UTILITY EASEMENT
I
-
I
I
�
-
T PROPERTYf LINE- 29-8 27=N 893766" A
J
SITE CLAN *.
REFERENCE+ NONE sCn4EI"-60'-O" NORTH
255'-6"
254' -7"
LOT : 06
BLOCK: 04
SUBDIVISION:
NILLIAMS CREEK
PHASE 2
COLLEGE STATION TX
BRAZOS COUNTY
... ,.es ,,.*;,-:� ws-�.�,.�.""��F. v"'x'4'g�"�'ar+ns-•vs^—e*-tom �`