Loading...
HomeMy WebLinkAboutRES2005-03790, 05-3803r PREPARED 6/26/06, 12:00:10 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/26/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 1202 HARRISONBURG LN SUBDIV: CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER . . PHONE PARCEL . . 569500-1441-0090 APPL NUMBER: 05-00003790 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 11/14/05 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 11/14/05 AP November 14, 2005 10:14:15 AM bkorthauer Strings On Setbacks O.K. Slab Ground Installed B115 01 12/21/05 OC BLDG, FRAMING TIME: 17:00 12/21/05 AP December 13, 2005 11:36:42 AM bkorthauer B130 01 1/03/06 OC BLDG, INSULATION TIME: 17:00 1/03/06 AP January 3, 2006 7:59:02 AM kwolfe B125 01 6/26/ 6 I BLDG, FINAL TIME: 17:00 Ala ab� C. June 26, 2006 11:57:31 AM glsouth --, ----------------------- COMMENTS AND NOTES -------------------------------------- ------------ S ` o n nsl-2,11e oe Inspection Comments for Finals Date: 6/28/2006 Permit Year: 5 Permit Number: 3790 Address: 1202 HARRISONBURG LN Type Inspection Type Code si ins Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. 13100 BLDG, FOUNDATION -SLAB I IC Slab Ground Installed WF0711431 / 001 City of College Station PAGE 1 REQ. DATE: 10/25/05 10/25/05 8 : 4 7 : 2 7 LOCATION: 1202 HARRISONBURG LN LOC ID: 202684 REQUESTOR: ED FROEHLING ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT 4" SEWER TAP AND 3/4" WATER TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/25/05 SCHED COMPLETION: 10/25/05 ******************************************************************************** JOB ORDER RESULT COMVEENTS City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . Contractor . . . . Application number Description of Work Construction type . . . Occupancy type . . . . Flood Zone . . . . . . Approved . . . . . . . 3m M-1 569500-1441-0090 1202 HARRISONBURG LN COLLEGE STATION TX 77845 SHENANDOAH #14, BLOCK 41, LOT 9 SINGLE FAMILY RESIDENTIAL ED FROEHLING BUILDER INC ED FROEHLING BUILDERS 979 776-8266 05-00003790 000 000 RESIDENTIAL, 1 UNIT DETACHED NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX Build-'hq Official VOID UNLESS SIGNED BY BUILDING OFFICIAL ,I BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 05-00003790 Date 10/27/05 Property Address . . . . . . 1202 HARRISONBURG LN Property ID:. 569500-1441-0090 R #. Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 125862 Owner ------------------------ Contractor ------------------------ ED FROEHLING BUILDERS ED FROEHLING 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 --- Structure.Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1907.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 427.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . BK Permit Fee . . . . 538.00 Plan Check Fee .00 Issue Date . . . . 10/25/05 Valuation . . . . 125862 Expiration Date . . 4/23/06 Qty Unit Charge Per Extension BASE FEE 460.00 26.00 3.0000 THOU BLDG, VAL 100001-500000 78.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) ----------------------------------------------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: .J/ n t.iYOI _11, qh�� ' BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 05-00003790 Date 10/27/05 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR.HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE --------------------------------------------=- ---------------------- BUILDING DEPT REPRESENTATIVE: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number 05-00003790 Page 3 Date 10/27/05 Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING; ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES Other Fees SEWER TAP 4" WATER TAP 3/4" 350.00 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due BUILDING DEPT REPRESENTATIVE: AM-04 ___ BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . ----------------- ---------- Permit Fee Total 538.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1288.00 05-00003790 538.00 .00 .00 .00 750.00 .00 1288.00 .00 ---------------------------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: /,(J A4 Page 4 Date 10/27/05 .00 .00 .00 .00 I - .. I Ofloe u, se onry . CITY OF COLLEGE STATION Pfawf ing 6• Development'Se vicst APPLICATION FOR BUILDIN&PERMIT CITY OF COLLEGE STATION . 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764.3570 (979) 764.3496 FAX WWW.CSTX.GOV DATE: -71 APPLICATION # I v , TEMP POLE .# ✓ y ADDRESS/LOCATION: LOT ,/BLOCK ALA— SUBDIVISIONi�IJat�ipo ✓ SEC/PH BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: b > >�L! IJ -, I PHONE: TICD - i8z r4 CONTRACTOR ADDRESS: - -77Ca,lc ELECTRICIAN: t3PLUMBER: PLC-- 5 HVAC: GOOD CENTS Residential only): t • CLASS OF WORK ACCESSORY/STORAGE LOCATION . RE -ROOF ADDITION OVIN.G SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOCIATION/AREHITECTUAL OR DESIGN REgIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ I Z"5,1002 . CO TOTAL AREA: aO HEATED AREA: (_ _ 90-7 (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM �EWER TAP: �r SIZE WATER TAP: ?j SIZE t r. SIZE tI OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE ATTACHED NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYF'E: EXTERIOR WALL TYPE FOUNDATION TYPE: ROOF TYPE: BLE TRIPLE' C AED , a CARPORT SIGNATURE O1 APPLIC 6ch Lea i *If proposed work involves ne com . I cons or a_ cade improvekts, commercial property, building elevations a e required. Official Use Only Plans Examiner Zoning Official ions to an existing PleyvE r NO Energy Code Compliance Information % Glazing of exterior walls 6 V/ Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) �5D Insulation R value of. ceiling 2 (vaulted areas/no attic) !� Glazing SHGC Glazing U-Factor R value of ductwork �P / A/C SEER Rating Lot 10 Block 41 ELEC BOX 5' FROM CORNER Harrisonburg Court 50' R.O.W. - 27'Pavement N 45 26' 36" E - 65.0' Crt crate 1 Drivewdy I M ZI_ N 77-' 49.5' Shenandoah Phase 14 Proposed OC Residence a Lot 9 Block 41 N � N 1202 Harrisonburg M I 7.5' co M j N . Note: Buidinp Setback Lines per City of Colepe Station Unifided Development Ordinance N26V N 45 26' 36" E - 65.0' Lot 8 Block 41 -- 10' P.U.E. ' I r PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning d Dtvilopmmt Savica PLAN REVIEW/PERMIT NUMBER# D BUILDING ADDRESS:%o ATE: ,� / I �.� I. Foundation Re uirements A. Concrete minimum Pc of 3000 PSI N B. Minimum four 4 Inch slab thickness C. vapor barrier 1. 6 mil poly D. Slab/beam or pier la out shown 1. Footin s/beams are continuous over the len th and width of foundation 2. Dimensions i 3. Footin s 30" exterior, 24" interior unless over 60' long then 30" 4. S acin of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Mason fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor Wall, Ceiling and Roof Requirements A. Girder or sill dimensions grade & species B. Floor 'oist sizes acingrade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracin Methods indicated on plans E. Header sizes indicated on plans F. Emer enc bedroom a ress 1. Exit direct to outside 2. Operable window a. Twen 20 inch clear width by twenty-four 24 inch clear hei ht b. Maximum sill height of fo -four 44 inches above finished floor G. O erable bathroom window required when mechanical ventilation is not provided H. Stud rade and s acin I. Exterior wall details 1. Exterior wall coveringindicated on plans 2. f%heathling indicated on lans 3. Moisture barrier indicated on plans J. Roof framin an or elevation shown K. Ceiling'joist size,lRacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans I. If located in ara a it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes s acl ng, grade,slope and purlins if reauired. 4, CITY OF COLLEGE STATION Planning d Devilepmtnt Savlca PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS Framing: Floor, Wall, Ceiling and Roof Requirei O. Roof Covering 1. Roof Decking indicated on plans. 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, w-C location indicated on plans Q. Tempered Glass required in all hazardous li R. Overhangs allowed on zero lot line construe S. Protected openings on walls < three feet fri T. One hour tenant separation to roof deck be Stairway Requirements A. Stairway Details 1. Maximum user height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Ma) 4. Stairway width not less than 36 inch 5. Stairway headroom not less that six B. Winder details 1. Treads a minimum of six (6) inches 2. Treads a minimum of ten (10) inchi narrow ed e C. Spiral stairway details 1. Riser height less than nine and one 2. Treads a minimum of seven and or inches from the narrow edge 3. StairYaY width not less than twenty 4. Headroom required not less than si 5. All treads must be identical D. Guards/handrail details I. Guards required when a porch, dec above -grade or finished floor 2. Handrails are re uired on stairwa 3. Handrails must be thirty-four to thir leadinged a of the tread 4. Handrails must not project more th stairwa 5. Guards must be a minimum of thin 6. Guards & handrails along open -sic railing or uprights that [event the N. Fire lace Re ulrements to be indicated on A. Hearth extensions 1. Fireplace open n < 6 s ft extei 2. Fireplace opening > 6 s . ft. extei B. Mason fire lacerequires 2' clearance ft �. Chimneys must extend at least three (3) least two 2 feet higher than anv portion nnms tcon[muep) NA/EHF Ils, ceiling & roofs must have the size, grade & ►cations :tion u to 18" ►m property line tween duplexes OK ;. difference es ft. eight 6'-8" on narrow ed e is at a distance of twelve (12) inches from the -half 9-1/2 inches e=half (7-1/2) inches at a distance of twelve (12) :six inches x ft six 6'-6" inches K, balcony or landing is thirty (30") inches ► located our or more risers above floor/grade y-eight (34-38) inches when measured from the an four & one-half (4-1/2") inches into width of a -six 36 inches above finished floor e(s) of stairway must have intermediate passage of a four (41 inch sphere lans M isions: 8" & 16' forward isions: 12' side & 20' forward 3m all combustible materials eet higher than the highest point of roof & at of the building within ten 10 feet horizontal u A CITY OP COLLEGE STATION Planning d- Dmkpmmt&n1ca V. Electrical Service Requirements A. Electrical plan to include: 1. Electrical fixtures & switch PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS I wtw%im ►wctaon s maicatea as required 3. GFI circuits indicated where required 4. Are fault protection for bedroom circuits 6. Panel and Meter location 'I. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided D. Water heaters elevated 18" when installed in the garage or room directly off garage JII. Mechanical Requirements A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside (excludes ductless units) B. Attic installed HN.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) VIII. Energy Requirements A. Compliance software worksheet (REScheck) submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 860 Permitted use for district Density requirements Minimum lot size on zero lot side 18" max. overhang allowed Street Ordinance Requirements Maximum drive width for residence is 28' (combined for circul Minimum 20 feet from driveway to side (intersectingy street Subdivision Regulations — Ordinance 690 Approved subdivision Plat filed F_loodplain Regulations — Ordinance 1301 Does not block any water course or divert any flow L Elevation certificate if ranuirerl .-o CITY OF COLLEGE STATION PUmmind d Dewlephtmt $mien PLANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS /o -zy-� DATE CrrY OF COLLEGE STATION Plannlq &Dnalopmmr &rvkrr Storm Water Discharge Pe Texas Pollution Discharge Elimination System General Permit NO TXR 150000, The State of Texas assumed regulatory authority over storm water discharges associated with construction activities, effective March 5, 2003. The regulatory requirements under the general .permit are based upon the area of land disturbed and are classified Into two categories: Large Construction Activity: 5 or more acres of disturbed land or part of a larger common Ian of development that will disturb 5 or more acres. - g n 1. Obtain a copy of TPDES GP No. TXR 150000 2. Develop and Implement a Storm Water Pollution Prevention Plan 3. Two days prior to the start of construction, submit a Notice of Intent to TCEQ 4. Provide a copy of the Notice of Intent to the City 5. Submit a Notice of Termination to TCEQ once the site has reached final stabilization Small Construction Activity: at least 1 but less than 5 acres, or is part of a larger common plan of development that will disturb at least 1 but less than 5 acres. 1.Obtain a copy of TPDES GP No. TXR 150000 2. Develop and implement a Storm Water Pollution Prevention Plan 3. Prior to starting construction, post a Construction Site Notice as in Part II.D.2 at the site 4. Provide a copy of the Construction Site Notice to the City Additional information can be obtained from: TCEQ Website: www.tnrcc.state.tx.us/permitti /water erm/ww erm/construct.html#additional This website provides all associated documents and explanations including NOI, GP, etc. Compliance assistance can be obtained from: Donnie Willis Drainage Inspector City of College Station 979-764-6375 dwillls@cstx.gov Larger Common Plan of Development — A construction activity is part of a larger common plan of development if it Is completed in separate stages, separate phases, or in combination with other construction activities Example 1: A subdivision is being built. You are grading 0.75 acres, another company Is clearing 4 different acres, and a contractor is excavating another 0.5 acres. In this case, the total area that would be disturbed Is 5.25 acres, so each contractor would fall under the requirements associated with disturbing 5 or more acres. Example 2: At first, your project calls for you to grade, clear, or excavate a total of 0.93 acre. But after your project begins, you learn that you must disturb another 0.15 acre. Because this project disturbing 1 to less than 5 acres. has grown to disturb a total of 1.08 acres, you must obtain coverage under the requirements for REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\1218MV.rck TITLE: 1202 HARRISONBURG LANE CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 10/21 /05 DATE OF PLANS: 4/8/05 PROJECT INFORMATION: SPEC HOME LOT 9 BLOCK 41 SHENANDOAH PHASE 14 COMPANY INFORMATION: ED FROEHLING BUILDER, INC NOTES: COOPER PLAN WITH 2O05 CODE CHANGES COMPLIANCE: Passes Maximum UA = 616 Your Home UA = 547 11.2% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.36 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Front Projection factor: 0.19 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Left Side Projection factor: 0.27 Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1907 30.0 0.0 67 396 13.0 0.0 24 63 0.640 40 38 0.400 15 412 13.0 0.0 31 13 0.640 8 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 315 deg. from North; Comp. orient.: Left Side Projection factor: 0.81 Wall 3: Wood Frame, 16" o.c. 396 13.0 0.0 25 Window 3: Metal Frame:Double Pane with Low-E 95 0.640 61 SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Back Projection factor: 0.23 Wall 4: Wood Frame, 16" o.c. 412 13.0 0.0 30 Window 4: Metal Frame:Double Pane with Low-E 41 0.640 26 SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Floor 1: Unheated 202 0.0 210 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 10 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RES checkVersion 3.5 Release lb (formerly MECchec� and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer Date ��