HomeMy WebLinkAboutADDN2005-037830
0
PREPARED 3/08/06, 12:13:04 INSPECTION TICKET PAGE 4
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/08/06
-------------------------------------------------------------------------------------------------
ADDRESS . : 200 SUFFOLK AVE SUBDIV: OAKWOOD
CONTRACTOR JEFFERSON CHRISTIAN HOMES PHONE (979) 694-1272
OWNER WEST, GAINES & SUSAN PHONE
PARCEL 481100-0011-0040
APPL NUMBER: 05-00003783 RESIDENTIAL, ADDITION
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B105 01 10/26/05 JGM BLDG, FOUNDATION -PIER TIME: 17:00
10/26/05 AP October 25, 2005 4:29:14 PM kwolfe
late morning
B100 01 10/28/05 DS BLDG, FOUNDATION -SLAB TIME: 17:00
10/31/05 AP October 28, 2005 9:59:42 AM kwolfe
B115 01 12/13/05 RH BLDG, FRAMING TIME: 17:00
12/13/05 AP December 6, 2005 11:13:18 AM bkorthauer
B130 01 12/14/05 OC BLDG, INSULATION TIME: 17:00
12/14/05 AP December 14, 2005 11:31:55 AM bkorthauer
late afternoon
B125 01�•,/ 06 BLDG, FINAL TIME: 17:00
�r11�1 March 8, 2006 10:03:04 AM bkorthauer
. Q� �-d out Thursday —morning - 1 ' _ .� g,�
--- �-------------------------- ------ COMMENTS AND NOTES----------------------------V"` �s �!
0
� f
•
WF0740896 /
001 City of College Station
PAGE 1
REQ. DATE:
01/20/06 ✓�
01/20/06
10:06:29
LOCATION:
200 SUFFOLK AVE
LOC ID:
130642
REQUESTOR:
JEFFERSON CHRISTIAN HOMES ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
4" SWR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
01/20/06 SCHED COMPLETION:
01/20/06
********************************************************************************
JOB ORDER RESULT CONIlVM TTS
PREPARED 12/06/05, 12:00:02 INSPECTION TICKET PAGE 9
City of .College Station INSPECTOR: BUILDING INSPECTOR DATE 12/06/05
- - - - - - - - - - - 7 - - - 7 - - - - - - - - - - - - - - - - --- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
ADDRESS :�.-200 SUFFOLK AVE SUBDIV: OAKWOOD
CONTRACTOR f=JEFFERSON CHRISTIAN HOMES PHONE (979) 694-1272
OWNER : WEST, GAINES & SUSAN PHONE
PARCEL 481100-0011-0040
APPL NUMBER: 05-00003783 RESIDENTIAL, ADDITION
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
--------------------------------------------------=---------------------------------------------
B105 01 10/26/05 JGM BLDG, FOUNDATION -PIER TIME: 17:00
10/26/05 AP October 25, 2005 4:29:14 PM kwolfe
late morning
B100 01 10/28/05 DS BLDG, FOUNDATION -SLAB TIME: 17:00
10/31/05 AP October 28, 2005 9:59:42 AM kwolfe
B115 01 12/06/05 ,I, BLDG, FRAMING TIME: 17:00
oZ 3 QS/wG� December 6, 2005 11:13:18 AM bkorthauer
CONTINUED ONTO NEXT PAGE
:i Cat••
PREPARED 12/13/05, 8:02:05 INSPECTION TICKET PAGE 3
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/13/05
------------------------------------------------------------------------------------------------
ADDRESS . : 200 SUFFOLK AVE SUBDIV: OAKWOOD
CONTRACTOR JEFFERSON CHRISTIAN HOMES PHONE (979) 694-1272
OWNER WEST, GAINES & SUSAN PHONE
PARCEL 481100-0011-0040
APPL NUMBER: 05-00003783 RESIDENTIAL, ADDITION
------------------------------------------------------------------------------------------------
PERMIT: MECH 00 MECHANICAL PERMIT SUB: CLIMATE MASTERS (979)775-6572
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
M100 01 12/13/05 BI MECH, ROUGH IN TIME: 17:00
December 9„ 2005 3:32:13 PM bkorthauer
morning - J
-------------------------------------- COMMENTS AND NOTES-----------------------------
PREPARED 12/13/05, 8:02:29 INSPECTION TICKET PAGE 8
City of College Station INSPECTOR: ROBERT HUDSON DATE 12/12/05
------------------------------------------------------------------------------------------------
ADDRESS 200 SUFFOLK AVE SUBDIV: OAKWOOD
CONTRACTOR JEFFERSON CHRISTIAN HOMES PHONE (979) 694-1272
OWNER WEST, GAINES & SUSAN PHONE
PARCEL 481100-0011-0040
APPL NUMBER: 05-00003783 RESIDENTIAL, ADDITION
------------------------------------------------------------------------------------------------
PERMIT: ELEN 00 NEW ELECTRIC PERMIT SUB: GILMORE ELECTRIC COMPANY-PAUL (979)822-3840
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS '
------------------------------------------------------------------------------------------------
E110 01 12/12/05 RH ELEC, ROUGH IN TIME: 17:00
Alllew T/S: 12/12/2005 08:40 AM GLSOUTH-----------------------
-------------------------------------- COMMENTS AND NOTES--------------------------------------
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F C O M P L E T I O N
P E R M A N E N T
Issue Date . . . . . .
Parcel Number .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner . . . . . . . . .
Contractor . . . . . .
Application number
Description of Work
Construction type . . .
Occupancy type . . . .
Flood Zone . . . . . .
Approved . . . . .
3/09/06
481100-0011-0040
200 SUFFOLK AVE
COLLEGE STATION TX 77840
OAKWOOD
OAKWOOD, BLOCK 1A, LOT 4
SINGLE FAMILY RESIDENTIAL
WEST, GAINES & SUSAN
JEFFERSON CHRISTIAN HOMES
979 694-1272
05-00003783 000 000
RESIDENTIAL, ADDITION
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
Bu�Ldding Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION., TX 77840
PHONE: (979)764-3570. FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
05-00003783 Date 10/25/05
200 SUFFOLK AVE
481100-0011-0040
R36400
RESIDENTIAL, ADDITION
OAKWOOD
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
80000
Owner Contractor
------------------------ -----------=------------
WEST, GAINES & SUSAN OWNER
200 SUFFOLK AVE
COLLEGE STATION TX 778403018
--- Structure Information 000 000 ADDITION
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
TYPE OF GARAGE (ATT/DET) NA
HEATED AREA 980.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 1.00
NUMBER OF BEDROOMS 1.00
SEWER TYPE PUBLIC
TAZ 333.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . BK
Permit Fee . . . . 380.00 Plan Check Fee .00
Issue Date . . . . 10/25/05 Valuation . . . . 80000
Expiration Date . . 4/23/06
Qty Unit Charge Per Extension
BASE FEE 260.00
30.00 4.0000 THOU BLDG, VAL 50001-100000 120.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
--------------------------------------
BUILDING DEPT REPRESENTATIVE: •/
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION„ TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 05-00003783
Page 2
Date 10/25/05
Special Notes and Comments
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
----------------------------------------- - --- -------------------------
BUILDING DE PRESENTATIVE:
APPLICANT:��I/I/
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION„ TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 05-00003783 Date 10/25/05
----------------------------------------------------------------------------
Special Notes and Comments
DEGREES
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS.SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Narrow wall bracing prescriptive 41x8' osb or plywood per
code
Fee summary Charged
----------------- ----------
Paid Credited Due
Permit Fee Total 380.00 380.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 380.00 380.00 .00 .00
----------------------------------------- -- -- - -----------------------
BUILDING DEP PRESENTATIVE:
APPLIC T:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1:3 1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION'./TX.US
ADDRESS/LOCATION: K--
LOT BLOCK 11� pS'SUBDIVISION-
BUSINESS/OWNER NAME:
Fa Ofte Use ONy
DATE:
APPLICATION #
TEMP POLE #
(LcG toq
SEC/PH
PHONE:
CONTRACTOR/HOMEOWNER:� Q � ('h�(�An b%fl wo :at u"1 ' Inz
r
CONTRACTOR ADDRESS: V Iru I0149 W I X 3784z
ELECTRICIAN: .� 0m 11f , PLUMBER: 15whA
HVAC: Clr GOOD CENTS (Residential only):
ACCESSORY/STORAGE
ADDITION
DEMOLITION (Asbestos Survey)
DUPLEX (Landscape Plans
Req)
DESCRIPTION OF WORK: AM
STRUCTURE USE:
CLASS OF WORK
LOCATION
MOVING
NEW CONSTRUCTION
REMODEL/RENOVATION
RE -ROOF (Total/Partial)
SHELL ONLY
SLAB ONLY
SWIMMING POOL
HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ w, (M
TOTAL AREA: HEATED AREA:
(Cost oY Labor and Materials)
PUBLIC SEWER
NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM
NUMBER OF BATHROOMS:
SEWER TAP:
INTERIOR WALL TYPE:Ern�
SIZE
❑ WATER TAP:
❑ OTHER TAP:
❑ TEMP POLE
GARAGE TYPE:
NIrAa
SIZE
SINGLE a
ATTACHED a
SIGNATURE OF APPLICANT:
EXTERIOR WALL TYPE:
FOUNDATION TYPE
ROOF TYPE:
DOUBLE a
DETACHED
�— Official Use Only
��? - 2 yC_ a J
Plans Examiner
�]1 3 :' R, 9,
TRIPLE a
CARPORT a
Zoning Official
Comments.
E or NO
I
1
Energy Code Compliance Information
% Glazing of exterior walls
►'�', Insulation R'value'of`eXtenor Walff
Insulati°on'R value of ceiling 1 (flat area`s)E ' t- 30 �
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC (�
Glazing U-Factor e 7S
R value of ductwork '
A/C SEER rating
� PLAN
REVIEW
ONE and TWO FAMILY
CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS
1'lanninj d DudopmmtStrvlu
PLAN REVIEW/PERMIT NUMBER# 0 5- - 3-7
BUILDING ADDRESS: 8
Zo o SU -f
wunaallon Kequirements
A Concrete minimum f'c of 3000 PSI
B, Minimum four (4) inch slab thickness
C. Vapor barrier
1. 6 mil of
D. Slab/beam or Dier layout shown
1. Footin s/beams are continuous over the lenciti and wic
2. Dimensions
3. Footings (30" exterior, 24"interior unless over 60' long
4 Spacing of beams does not exceed 15'
E Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. asonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing; Floor, Wall, Ceiling and Roof Requirements
A Girder or sill dimensions grade & s ecies
B. Floor joist size, spacing grade & direction of span indicted on
C. Treated sill late or m bottolate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
DATE: �d 11 dS
of foundation
en
1. exit direct to outside
2. Operable window
a Twenty (20) inch clear width by twenty-four (24) inch clear height
b. Maximum sill hei ht of fo -four 44 inches above finished floor
, Operable bathroom window required when mechanical ventilation is not provide
H Stud a add and spacing
I Exterior wall Wai�� &
1. Exterior wall covering indicated on plans
2. Sheathin indicated on lans
3. Moisture barrier indicated on tans
J. Roof framing plan or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
i. If located in ara a it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade slope and purlins if reauired_
I'll
CITY OF COLLEGE STATION
Planning d DowlopmtntSovinr
II. Framing: Floor, Wall, Cell
O. Roof Covering
1. Roof Deckin.
2. Moisture bar
P. All girders & beams
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
ng and
ndicated on pi
r indicated on
r support of 0(
on mans
cements (continued)
S.
, walls, ceiling & roofs must have the size, grade
Q.-Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. ei ht 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum of ten (10) inches at a distance of twelve (12) inches from the
narrow ed e
C. Spiral stairway details
1 Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one=half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6'-6" inches
5. All treads must be identical
D. Guards/handmil tictniie
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2 Handrails are required on stairways located our or more risers above floor/grade
3 Handrails must be thirty four to thirty-eight (34-38) inches when measured from
_ leading edge of the tread
4 Handrails must not project mo
stairway re than four & one-half (4-1/2") inches into width of a
5. Guards must be a minimum of thirty-six (361 inches above finished floor
6. Guards & handrails along open -sides) of stairway must have intermediate
railina or uprights that prevent the passage of a four 4 inch sphere
. Fireplace Requirements (to be indicated on plans)
A. Hearth extenSinnc
1.
A
i✓. unimneys must
least two (2) fee
9 -'� 6 sq, ft, (extensions: 8" & 16" forward)
_? B sq. ft. (extensions. 12" side & 20" forward)
es 2" clearance from all combustible materials
at least three (3) feet higher than the highest point of roof & at
than any portion of the building within ten (10) feet horizontal
.A
CITY OF COLLEGE STATION
Planning d' Dtwlopmmt $mien
V. Electrical Service Requirements
A. Electrical plan to include:
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Are fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
Vll. Mechanical Requirements
A All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside (excludes ductless units)
B. Attic installed HN.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipn
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
VIII. Enerdv Reauiramanfe
A. Compliance software worksheet (REScheck) submitted, or
a Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements Ordinance 8
use
S
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
Maximum drive width for residence is 28' (combined for circ
Minimum 20 feet from driveway to side (intersecting) street
Subdivision Regulations — Ordinance 690
Floodplain Regulations — Ordinance 1301
Does not block any water course or divert any
Elevation certificate If required
di
CITY OF COLLEGE STATION
Planning d Dtwko mmt Sevlea
Comments:
PLANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
DATE
CM OP COLLEGE STATION
PkHosiv d• Dvw4ment &rvket
Storm Water Discharae Pe
Texas Pollution Discharge Elimination System General Permit NO TXR 150000,
The State of Texas assumed regulatory authority over storm water discharges associated with
construction activities, effective March 5, 2003. The regulatory requirements under the general
.permit are based upon the area of land disturbed and are classified into two categories:
Large Construction Activity: 5 or more acres of disturbed land or part of a lacger com non plan of
development that will disturb 5 or more acres.
1. Obtain a copy of TPDES GP No. TXR 150000
2. Develop and implement a Storm Water Pollution Prevention Plan
3. Two days prior to the start of construction, submit a Notice of Intent to TCEQ
4. Provide a copy of the Notice of Intent to the City
5. Submit a Notice of Termination to TCEQ once the site has reached final stabilization
Small Construction Activity: at least 1 but less than 5 acres, or is part of a larger common plan of
development that will disturb at least 1 but less than 5 acres.
1. Obtain a copy of TPDES GP No. TXR 150000
2. Develop and implement a Storm Water Pollution Prevention Plan
3. Prior to starting construction, post a Construction Site Notice as in Part II.D.2 at the site
4. Provide a.copy of the Construction Site Notice to the City
Additional information can be obtained from:
TCEQ Website: www.tnrcc.state.tx.us/ ermittin /water ern/ww erm/construct.html#additional
This website provides all associated documents and explanations including NOI, GP, etc.
Compliance assistance can be obtained from: Donnie Willis
Drainage Inspector .
City of College Station
979-764-6375
dwillis@cstx.gov
L_ areer Common Plan of Development — A construction -activity is part of a larger common plan of
development if it is completed in separate stages, separate phases, or in combination with 'other
construction activities
Example 1: A subdivision is being built. You are grading 0.75 acres, another company is clearing 4
different acres, and a contractor is excavating another 0.5 acres. in this case, the total area that
would be disturbed is 5.25 acres, so each contractor would fall under the requirements associated
with disturbing 5 or more acres.
Example 2: At first, your project calls for you to grade, clear, or excavate a total of 0.93 acre. But
after your project begins, you learn that you must disturb another 0.15 acre. Because this project
has grown to disturb a total of 1.08 acres, you must obtain coverage under the requirements for
disturbing 1 to less than 5 acres.