PREPARED 1/13/06, 12:05:53 INSPECTION TICKET PAGE 14
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 1/13/06
------------------------------------------------------------------------------------------------
ADDRESS . : 8438 LAUREN DR SUBDIV:
CONTRACTOR K M CUSTOM HOMES PHONE (979) 589-3739
OWNER MUCO VERDE, LLC PHONE
PARCEL 222222-0002-0190
APPL NUMBER: 05-00003781 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 11/11/05 JGM BLDG, FOUNDATION -SLAB TIME: 17:00
11/11/05 AP November 11, 2005 8:52:07 AM bkorthauer
late afternoon
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 12/05/05 DS BLDG, FRAMING TIME: 17:00
12/05/05 AP T/S: 12/05/2005 11:44 AM GLSOUTH -----------------------
B130 01 12/06/05 BH BLDG, INSULATION TIME: 17:00
12/06/05 AP December 6, 2005 2:29:05 PM kwolfe
December 6, 2005 3:19:52 PM kwolfe
B125 01 1 13/06 I/; BLDG, FINAL TIME: 17:00
i' t (I�Coo VIP 04�- January 13, 2006 9:12:15 AM bkorthauer
----=------------------------------ CONTINUED ONTO NEXT PAGE ----------------------------
,4e
Date: 1/17/2006
Inspection Comments for Finals
Permit Year: 5 Permit Number: 3781
Address: 8438 LAUREN DR
Insp.
inspection Type Code
Description
p.
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B130
BLDG, INSULATION
IC
December 6, 2005 3:19:52 PM kwolfe
E150
ELEC, FINAL
IC
01/10/2006 04:15 PM RH PDA
E150
ELEC, FINAL
IC
plugs hangingout in kitchen. correct electrical bonding in
E150
ELEC, FINAL
IC
panel.
E150
ELEC, FINAL
IC
01/13/2006 11:52 AM RH PDA
E150
ELEC, FINAL
IC
Groundwire to groundrod is cut.
P125
PLBG, FINAL
IC
01/13/2006 03:57 PM JGM PDA
P125
PLBG, FINAL
IC
gas test not holding, need one inch clearance on flue
P125
PLBG, FINAL
IC
pipe, screw in flue pipe connector, need to replace pipe
P125
PLBG, FINAL
IC
on tmp drain line where it was heated for bend
Page 1
Kim Wolfe -Insulation request inspection result, 8438 Lauren, #05-3781 Page 1
From: Brian Henry
To: Southerland, Gina
Date: 12/6/2005 2:27:21 PM
Subject: Insulation request inspection result, 8438 Laure #05-3781
Print for file
Inspected insulation, 8438 Lauren, #05-3781, KM Homes, 12-6-05
Inspection result: Inspected OK for Good Cents
Notes:
Complete framing inspection notes.
CC: ` Korthauer, Brittany; Wolfe, Kim
WF0715757 / 001 City of College Station PAGE 1
REQ. DATE: 11/10/05 11/10/05 16:28:57,.
LOCATION: 8438 LAUREN DR LOC ID: 200246u�`
REQUESTOR: K M CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN 17
REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT,,,:.
TEMP POLE PASSED
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 11/10/05 SCHED COMPLETION: 11/10/05
JOB ORDER RESULT CONIV=S
::fill:lu
i Y.A
I
u.•
md,
r..
n,
Ids
WF0714379 / 001 City of College,Station
PAGE 1
REQ. DATE:
11/07/05
11/07/05
13:31:03
LOCATION:
8438 LAUREN DR
LOC ID:
200246
REQUESTOR:
K M CUSTOME HOMES ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT�w.',
4 " SWR TAP 3 / 4 " WTR TAP
TASK:
SET UP NEW UTILITY ACCT SET
READY
u,..
SCHED START:
11/07/05 SCHED COMPLETION:
11/07/05"
JOB ORDER RESULT CONIlV=S
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . . 1/18/06
Parcel Number . . . .
. 222222-0002-0190
Property Address . .
. 8438 LAUREN DR
COLLEGE STATION TX 77840
Subdivision Name . .
.
Legal Description . .
. NORTH FOREST
BLOCK 2
LOT 19
Property Zoning . . .
. SINGLE FAMILY RESIDENTIAL
Owner . . . . . . . .
. MUCO VERDE, LLC
Contractor . . . . .
. K M CUSTOM HOMES
979 589-3739
Application number
05-00003781 000 000
Description of Work
RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . .
. COMBUSTIBLE (UNPROTECTED)
Occupancy type . . .
. RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . .
. ,
Approved . .
--I�urYifig- Off icia1
VOID UNLESS SIGNED BY BUILDING OFFICIAL
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 05-00003781 Date 11/07/05
Property Address . . . . . . 8438 LAUREN DR "
Property ID: 222222-0002-0190 w..
mW
R #: R***** „
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 160000
Owner
Contractor
------------------------
MUCO VERDE, LLC
------------------------
K M CUSTOM HOMES
1305 W VILLA MARIA
KENNY MELESKY
BRYAN
TX 77801 10485 FM 2038
BRYAN TX 77808
(979) 589-3739
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1807.00 �
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 275.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KW
Permit Fee . . . .
640.00 Plan Check Fee .00
Issue Date . . . .
11/07/05 Valuation. 160000
Expiration Date . .
5/06/06
Qty Unit Charge
Per Extension
BASE FEE 460.00
60.00 3.0000
THOU BLDG, VAL 100001-500000 180.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
u o.
- - - - - - - - - - - - - - - - - - - - - - - - - -
BUILDING DEPT PRESENTAT�V/�
- - - - - - - - - - - - - - - - V - - - - - - - - - - - - - - - - - - - - - - - - - - y.".
A �<
APPLICANT:
BUILDING ,PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 05-00003781 Date 11/07/05
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT .w.
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
BUILDING DEPT 7,7ESENTATI
APPLICANT:
BUILDING .,PERMIT
CITY OF COLLEGE STATION.
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 05-00003781 Date 11/07/05 ..,
---------------------------------------------------------------------------...":,
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
u...
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY w.,
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH w
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN „•..
PRIVATE GARAGES
---------------------------------------- - - ----------------------------w.:
BUILDING DEPT 74RESENTATIVE
P
`
APPLICANT: `/VI
BUILDING ,PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number
. . . .
05-00003781
Date
11/07/05
----------------------------------------------------------------------------
Special Notes and
Comments
Narrow wall bracing
----------------------------------------------------------------------------
fully sheathed
with APA
garage framing.
Other Fees . . .
. . . . . .
SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
--------------------
Due
----------
Permit Fee Total
640.00
640.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00 w..,
Grand Total
1390.00
1390.00
.00
.00
---------------------------------- - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BUILDING DEPT R RESENTAT V
APPLICANT: //
�JUJw
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . .
Property Address . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . .
Property Use . . . . . . .
Property Zoning . . . . . .
Application valuation . . .
05-00003782
8438 LAUREN DR
222222-0002-0190
R*****
TEMP POLE
Date 11/07/05
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner
Contractor
------------------------
MUCO VERDE, LLC
------------------------
K M CUSTOM HOMES
1305 W VILLA MARIA
KENNY MELESKY
BRYAN
TX 77801
10485 FM 2038
BRYAN
TX 77808
(979) 589-3739
----------------------------------------------------------------------------
Permit . . . . . .
TEMP POLE
PERMIT
Additional desc . .
KW
Permit Fee . . . .
20.00
Issue Date . . . .
11/07/05
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . . .
. . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
--------------------
Due ..
W Y,.
Permit Fee Total
20.00
----------
20.00 .00
.00 w•
Other Fee Total
45.00
45.00 .00
.00 y;u
Grand Total
65.00
65.00 .00
.00
---------------------------------------- --� ----------------------------:,..:
BUILDING DEPTZPRESENT IVE:
APPLICANT: u...
ti
APPLICATION FOR BUILDING PERMIT
U1CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CLCOLLEGE-STA' 10N.TX.US
ADDRESS/LOCATION: 6 ve 18zf
LOT — ft-4OCK _
For Jrwe Use Only
DATE:
APPLICATION #
TEMP POLE # O� U
2 SUBDIVISION Kill II 11 tf 41 SEC/PH �
BUSINESS/OWNER NAME: LK �Ll� m YV% PHONE: ,
CONTRACTOR/HOMEOWNER:
PHONE: 5,g %z Z 7
CONTRACTOR ADDRESS: %D�fd�� Zd3 8;,YU4
ELECTRICIAN: e�`�s PLUMBER:
HVAC:kHy GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION IING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL
Required)
DESCRIPTION OF WORK: ORV) ies
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION#RJ
VALUATION: $ 1 lot), 000 TOTAL AREA: L
(Cost of Labor and Materials)
1- ❑ PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
y,(
���SEW'TAP:
SIZE /
WATER TAP: 3 /
SIZE
OTHER .AP:
EMP POLE
GARAGE TYPE
SIZE
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE
SINGLE F__] DOUBLE FVJ TRIPLE
ATTACHED EY IITAPPiqEl CARPORT
SIGNATURE OF APPLICANT:
Official Use Only
t) v L l —Or
Zj
G*� �1 ki
VI ( S,� (A)
HEATED AREA: 1901
C ments:
S or NO
ul
Energy Code Compliance Information
% Glazing of exterior walls - ✓
Insulation R value of exterior walls 3 /
Insulation R value of ceiling 1' (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
19 ----
Glazing SHGC�
Glazing U-Factor
1 G S
R value of ductwork
6�
A/C
SEER rating
PLAN REVIEW
ONE and TWO FAMILY
CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS
Alanninj d Dw1opment Sawica
PLAN REVIEW/PERMIT NUMBER#
S ` 3 -7
BUILDING ADDRESS:DATE: �0 1 zr / a
3
1. Foundation Requirements
A. Concrete minimum fc of 3000 PSI N
B. Minimum four 4 inch slab thickness
C. Va or barrier
1. 6 mil of
D. Slab/beam or ier la out shown
1. Footin s/beams are continuous over the len th and width of foundation
2. Dimensions
3. Footin s 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum re uirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Mason fire lace foundation reinforcement
F. Wood foundation details indicated
II. Framin . Floor Wall, Ceilin and Roof Re uirements
A. Girder or sill dimensions grade & species N K�
B. Floor joist size spacing, rade & direction of span indicted on plans
C. Treated sill Plate or bottom plale
D. Narrow Wall Bracin Methods indicated on plans
E. Header sizes indicated on plans
F. Emer ency bedroom egress
I. Exit direct to outside
2. Operable window If
a. Twenty 20 inch clear width by twenty-four 24 inch clear he ht
b. Maximum silt hei ht of fo -four (AA1 inches above finished floor
G, O erable bathroom window re -rod when mechanical) rentilati
`T�notoided H. Stud rade and s acin
I. Exterior wall details
.1. Exterior wall covering indicated on Diana
2. Sheathing.indicated on plans
3. Moisture barrier indicated on tans
J. Roof framing Ian or elevation shown
K. Ceiling'oist sizespacing, rade and direction of s an indicated on plans
L. Attic access location and size indicated on plans
I. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes s acin rade slope and pudins if required_
4A
CITY OF COLLEGE STATION
Planning d Dwilopmw Soviets
II. Framing: Floor, Wall, Cell
O. Roof Covering
1. Roof Deckin
2. Moisture bar
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
ng and Roof Requirements (continued)
indicated on plans.
P. All girders & beams for support of floors, walls, ceiling & roofs must
location indicated on plans
Q. Tempered Glass-----. . in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between du lexes
FIF Stairway Requirements
A. Stairwav Details
A
C.
A]
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft eight (6'
rider details
1 Treads a m'
the size, grade
inimum of six (6) inches on narrow edge
2 Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
viral stairway details
1. Riser height less than nine and one-half (9 1/2)
2. Treads a minimum of seven and one=half (7-1/',
inches from the narrow edge
3. Stairway width not less than twenty six inches
4. Headroom required not less than six ft six (6' 6") inches
5. All treads must be identical _
inches
) inches at a distance of twelve (12)
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are -required on stairwa(s located four or more risers above floor/ rade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than our & one-half (4-1/2") inches into width of a
stairwa
6. Guards must be a minimum of thi -six 36 inches above finished floor
6. Guards & handrails along open -sides) of stairway must have intermediate
railing or uprights that prevent the Dassage of a four 4 inch sphere
IV. Fireplace Requirements (to be indicated on plans)
A Hearth extanSinnc
I. Fireplace opening < 6 so. ft, (extensions: 8" & 16" forwa
2._ Fireplace opening > 6 sq ft (extensions 12" side & 20"
B. Masonry fireplace requires 2"
0. Chimneys must extend at lea
least two (2) feet higher than
feet higher than the highest point of roof & at
i of the building within ten (10) feet horizontal
lk
.I
PLAN REVI
EW
EW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning & Dm Igmw $mica
V. Electrical Service Requirements
A. Electrical plan to include:
�iv�u �cai nx[ures & switches indicated
2. Smoke detector location(s) indicated as required
3. GFI circuits indicated where required
4. Are fault protection for bedroom circuits
S. Panel and Meter location
I. Plumbing Requirements
A Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
ll. Mechanical Requirements
A All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside (excludes ductless units)
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equip ment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
III. Energy Requirements
A. Compliance software worksheet (REScheck) submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements —Ordinance 850
Permitted use for district
On zero lot side 18" max. overhang allowed
Drdinance Requirements
Maximum drive width for residence is 28' (combined for circ
Minimum 20 feet from driveway to side (intersecting) street
ubdivision Re4
_ Approved
Plat fled
loodplain Regi
Does not
ations — Ordinance 690
is — Ordinance 1361
any water course or c
cate if reauirad
any flow
e
.0
CITY OF COLLEGE STATION
Pbmnlnd d Dewlopmmt smica
Comments:
PLANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
DATE
r
CITY OF COLLEGE STATION
Plannlq d' Dw4mme &rvk,,
torm Water Discharge Permit
Texas Pollution Discharge Elimination System General Permit NO TXR 150000,
The State of Texas assumed regulatory authority over storm water discharges associated with
construction activities, effective March 5, 2003. The regulatory requirements under the general
.permit are based upon the area of land disturbed and are classified into two categories:
Large Construction Activity: 5 or more acres of disturbed land or part of a lar er commo a
development that will disturb 5 or more acres. - a n �I n of
1. Obtain a copy of TPDES GP No. TXR 150000
2. Develop and implement a Storm Water Pollution Prevention Plan
3. Two days prior to the start of construction, submit a Notice of Intent to TCEQ
4. Provide a copy of the Notice of Intent to the City
5. Submit a Notice of Termination to TCEQ once the site has reached final stabilization
Small Construction Activity: at least 1 but less than 5 acres, or is part of a larger common plan of
development that will disturb at least 1 but less than 5 acres.
1.Obtain a copy of TPDES GP No. TXR 150000
2. Develop and implement a Storm Water Pollution Prevention Plan
3. Prior to starting construction, post a Construction Site Notice as in Part II.D.2 at the site
4. Provide a copy of the Construction Site Notice to the City
Additional information can be obtained from:
TCEQ Website: www.tnrcc.state.tx.us/ ermittin /water erm/ww erm/construct.html#additional
This website provides all associated documents and explanations including NOI, GP, etc.
Compliance assistance can be obtained from: Donnie Willis
Drainage Inspector .
City of College Station
979-764-6375
dwillis@cstx.gov
L_ steer Common Plan of Development — A construction activity is part of a larger common plan of
development if it is completed in separate stages, separate phases, or in combination with 'other
construction activities
Example 1: A subdivision is being built. You are grading.0.75 acres, another company is clearing 4
different acres, and a contractor is excavating another 0.5 acres. In this case, the total area that
would be disturbed is 5.25 acres, so each contractor would fall under the requirements associated
With disturbing 5 or more acres.
Example 2: At first, your project calls for you to grade, clear, or excavate a total of 0.93 acre. But
after your project begins, you learn that you must disturb another 0.15 acre. Because this project
has grown to disturb a total of 1.08 acres, you must obtain coverage under the requirements for