Loading...
HomeMy WebLinkAboutRES2005-03758d� - 3��-� PREPARED 2/09/06, 7:57:58 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/09/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 1209 SPARTANBURG CT SUBDIV: SHENANDOAH PH 12 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER FROEHLING, EDWARD PHONE PARCEL 569500-1239-0030 APPL NUMBER: 05-00003758 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 11/10/05 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 11/10/05 AP November 10, 2005 1:35:42 PM kwolfe Strings On Setbacks O.K. Slab Ground Installed B115 01 12/21/05 OC BLDG, FRAMING TIME: 17:00 12/21/05 AP T/S: 12/19/2005 10:54 AM MALFORD ----------------------- B130 01 12/29/05 OC BLDG, INSULATION TIME: 17:00 12/29/05 AP December 29, 2005 8:52:52 AM kwolfe B125 01 2/09/06 BI BLDG, FINAL TIME: 17:00 vSoAV February 8, 2006 1:18:07 PM kwolfe --:---------'-------------------------- COMMENTS AND NOTES -------------------------------------- Date: 2/9/2006 Inspection Comments for Finals Permit Year: 5 Permit Number: 3758 Address: 1209 SPARTANBURG CT Type Inspection Type Code Status Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC Strings On Setbacks O.K. IB1001BLDG,FOUNDATION-SLABI IC ISIab Ground Installed M Page 1 WF0711804 / 001 Cityj,of_Cnllege Station PAGE REQ. DATE: 10/26/05 10/26/05 15:43:05 LOCATION: 1209 SPARTANBURG CT LOC ID: 201712 REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT TEMP POLE PASSED TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/26/05 SCHED COMPLETION: 10/26/05 JOB ORDER RESULT COMMENTS WF0710938 / 001 City of College Station PAGE 1 REQ. DATE: 10/21/05 10/21/05 16:05:35 LOCATION: 1209 SPARTANBURG CT LOC ID: 201712 REQUESTOR:" ED FROEHLING ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT SWR 4" WTR 3/4" ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/21/05 SCHED COMPLETION: 10/21/05 ******************************************************************************** JOB ORDER RESULT COWIIE TrS I` BUILDING PERMIT ti -''ITY OF COLLEG` STATION 1101 TEXAS AVE r COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 05-00003758 Date 10/21/05 Property Address . . . . . . 1209 SPARTANBURG CT Property ID: 569500-1239-0030 R #: R301618 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SHENANDOAH PH 12 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 133254 Owner Contractor ------------------------ FROEHLING, EDWARD ------------------------ ED FROEHLING BUILDERS 3887 HIGH LONESOME ED FROEHLING COLLEGE STATION TX 778459443 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2019.00 INTERIOR WALL TYPE SHEETROQK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 427.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit Fee . . . . 562.00 Plan Check Fee. .00 Issue Date . . . . 10/21/05 Valuation . . . . 133254 Expiration Date 4/19/06 Qty Unit Charge Per Extension BASE FEE 460.00 34.00 3.0000 THOU BLDG, VAL 100001-500000 102.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) ----------------------- BUILDING DEPT REPRESENTATIVE: - --�-- = ----------------------- APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 05-00003758 Date 10/21/05 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE .(FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER I'S PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If'PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -r - - - -------- BUILDING DEPT REPRESENTATIVE: Lv- APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION . 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 05-00003758 Date 10/21/05 ---------------------------------------------------------------------------- Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES Narrow wall bracing fully sheathed with APA garage framing ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 --------------------------------------------=------------------------------- Fee summary Charged Paid redited Due --------------------------------------------- - ---- --------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE"STATION 1101 TEXAS AVE COLLEGE STATION, TX• 7784.0 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . ----------------- ---------- Permit Fee Total 562.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1312.00 05-00003758 562.00 .00 .00 .00 750.00 .00 1312.00 .00 BUILDING DEPT REPRESENTATIVE: . i A n e APPLICANT: Page 4 Date 10/21/05 .00 .00 .00 .00 W"" CITY OF COLLEGE STATION Planning d Developmrnt Servierf i A.PPLICAMON FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CSTX.GOv ADDRESSILOCATION: l zo LOT 13 /BLOCK � SUBDIVISION BUSINESS/OWNER NAME: . ] For011ke Use Only DATE: 1 / REG APPLICATION # V 5 TEMP POLE .# v SEC/PH /Z PHONE: CONTRACTOR/HOMEOWNER: Cb �P 1ViV%� /L%, IAt PHONE: CONTRACTOR ADDRESS: J07 EOM} CS 77s ELECTRICIAN: .15 � j E�zT,� �C PLUMBER: PL �J, AA7. HVAC: L/G IA iQj VATI Ae GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION. RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION ` SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION' SWIMMING POOL Required) DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIG4 REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 133, 262. DO TOTAL AREA: HEATED AREA: 2(>l (Cost of Labor and Materials) ED-PUBLIC SEWER .❑ SEPTIC/TREATMENT SYSTEM ©SEWER TAP: �' I�VATER TAP: OTHER TAP: TEMP POLE GARAGE TYPE: IZE SIZE SIZE SINGLE ATTACHED NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE' TRIPLE t€TACHED a CARPORT SIGNATURE OF APPLICANT: *If proposed work involves new commercial co t us rnco ction or facade imp commercial property, building elevations are required. Official Use inlv /6. -7 ✓1 Plans Examiner. G f} 14 H 444 Zoning Official Fria C1.'1� i9PA6 novations to an existing C ents: — ES r NO Energy Code Compliance Information % Glazing of exterior walls f �� Insulation R value of exterior walls f 3 Insulation R value of ceiling 1 (flat areas) 3� Insulation R value of. ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor -%�- R value of ductwork / A/C SEER Rating N 45 26' 36" E - 65.0' / Note: Building Setback lines per 10' P.U.E. City of College Station Dnifided \ - � Development Ordinance # 2817 - - N LO ELEC BOX 3' FROM CORNER\ I N Lot 4 Block 39 47 0' .5, 2 � � S� _ Y 3henandoah'Phase 12 Y : ' " ` A Proposed 'Residence W :vim Lot 3 ( Bock 39 E N ,_ , o � ;1209 Spartanburg � � � -� o r � Y. la Y .302•' I 6979' I Concrete I r- Driveway ° ) to I I (0 j I s I N N 45 26' 36" E - 65.0' Spartanburg Court 50' R.O.W. - 27' Pavement Lot 2 Block 39 J PLAN REVIEW ONE and TWO FAMILY CITY OF COLLEGE STATION • OCCUPANCY REQUIREMENTS Planninj d Dnalopment $mica PLAN REVIEW/PERMIT NUMBER# 31 s$ p BUILDING ADDRESS:ATE: c -. I. Foundation Requirements A. Concrete minimum fc of 3000 PSI NAI B. Minimum four 4 Inch slab thickness C. vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footin s/beams are continuous over the len th and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. s2acing of beams does not exceed 15' E. Reinforcement details to meet minimum re uirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fire Di,ace foundation reinforcement F. Wood foundation details indicated II. Framin : Floor Wall Ceilin and Roof Requirements A. Girder or sill dimensionsgrade & species B. Floor 'oist size s acingrade & direction of span indicted on olans C. Treated sill late or bottom plate D. Nan'ow Wall Iracing Methods indicated on Ham E. Header sizes indicated on plans F. Emer(lien'1110111111 it bedroom a ress 1. Exit direct to outside 2. Operable window a. Twen 20 inch clear width b twen -four 24 inch clear hei ht b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window re uired when mechanical ventilation is not rovided H. Stud rade and s acing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist sizespacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes apaning grade,sloe and purlins if required. lf� . � PLAN RE VIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning d Drvrlo0mrnt Strvicn II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans, 2. Moisture barrier indicated on plans P. All girders &beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Over han s allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes III. Stairway Requirements A. Stairway Details 1. Maximum riser hei ht 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches B. Winder 5. Stairway headroom not less that six ft. ei ht 6'-8" details 1. Treads a minimum of six 6 inches on narrow ed e 2. Treads a minimum often (10) inches at 'adistance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one=half (7-1 /2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twen -six inches 4. Headroom required not less than six ft six 6'-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or. more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leadin edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open -sides) of stairway must have intermediate railingor uprights that prevent the assa a of a four, 4 inch sphere IV. Fire lace Re uirements to be indicated on tans A. Hearth extensions 1. Fire lace opening < 6 s ft extensions: 8" & 16" forward 2. Fire lace o enin > 6 s . ft. extensions: 12" side & 20" forward B. Mason fire lacerequires 2" clearance from all combustible materials 0. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal r PLAN REVIEW ONE and TWO FAMILY CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS Planning & Dtwlopmmt $mica V. Electrical Service Requirements A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Are fault protection for bedroom circuits S. Panel and Meter location VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed HN.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) N Re uirements om liance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) dinance Re uirements — Ordinance 850 mitted use for district si re uirements imum lot size Un zero lot side 18" max. overhang allowed Street Ordinance Requirements Maximum drive width for residence is 28' (combined for circul Minimum 20 feet from driveway to side (intersecting) street Subdivision Regulations — Ordinance 690 Approved subdivision Plat filed Floodplain Regulations — Ordinance 1301 Does not block any water course or divert any flow a CITY OP COLLEGE STATION Ammina d Dmkpmrn► Saul ra Com PLANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS Lo - zo .,or DATE CITY OF COLLEGE STATION Planning d,Developmmr Serakra torm Water Discharae Permit Texas Pollution Discharge Elimination System General Permit NO TXR 150000, construction activities, effective March 5, 2003. The regulatory The State of Texas assumed regulatory authority over storm water discharges associated with requirements under the general .permit are based upon the area of land disturbed and are classified Into two categories: Large Construction Activity: 5 or more acres of disturbed land or part of a lacger common Ian of development that will disturb 5 or more acres. 1. Obtain a copy of TPDES GP No. TXR 150000 2. Develop and Implement a Storm Water Pollution Prevention Plan 3. Two days prior to the start of construction, submit a Notice of Intent to TCEQ 4. Provide a copy of the Notice of Intent to the City 5. Submit a Notice of Termination to TCEQ once the site has reached final stabilization Small Construction Activity: at least 1 but less than 5 acres, or is part of a larger common plan of development that will disturb at least 1 but less than 5 acres. 1.Obtain a copy of TPDES GP No. TXR 150000 2. Develop and implement a Storm Water Pollution Prevention Plan 3. Prior to starting construction, post a Construction Site Notice as in Part II.D.2 at the site 4. Provide a copy of the Construction Site Notice to the City Additional information can be obtained from: TCEQ Website: www.tnrcc.state-tX.US/Dermittin /water erm/ww erm/construct.html#additional This website provides all associated documents and explanations including NOI, GP, etc. Compliance assistance can be obtained from: Donnie Willis Drainage Inspector City of College Station 979-764-6375 dwillis@cstx.gov Laraer Common Plan of Development — A construction activity is part of a larger common plan of development if it. is completed In separate stages, separate phases, or in combination with'other construction activities Example 1: A subdivision is being built. You are grading 0.75 acres, another company is clearing 4 different acres, and a contractor is excavating another 0.5 acres. In this case, the total area that would be disturbed Is 5.25 acres, so each contractor would fall under the requirements associated with disturbing 5 or more acres. Example 2: At first, your project calls for you to grade, clear, or excavate a total of 0.93 acre. But after your project begins, you learn that you must disturb another 0.15 acre. Because this project has grown to disturb a total of 1.08 acres, you must obtain coverage under the requirements for disturbing 1 to less than! 5 acres. Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\1401 EK.rck TITLE: 1209 SPARTANBURG COURT CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 10/19/05 DATE OF PLANS: JANUARY 22, 2003 PROJECT INFORMATION: SPEC HOME COMPANY INFORMATION: ED FROEHLING BUILDER, INC NOTES: SAME PLAN AS 1401 ELKTON COMPLIANCE: Passes Maximum UA = 638 Your Home UA = 545 14.6% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.37 Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 2019 30.0 0.0 71 Wall 1: Wood Frame, 16" o.c. 460 13.0 0.0 30 Window 1: Metal Frame, Double Pane with Low-E 60 0.650 39 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Front Projection factor: 0.18 Door 1: Solid 38 0.400 15 Wall 2: Wood Frame, 16" o.c. 485 13.0 0.0 35 Window 2: Metal Frame:Double Pane with Low-E 56 0.650 36 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Left Side Projection factor: 0.18 Wall 3: Wood Frame, 16" o.c. 409 13.0 0.0 29 Window 3: Metal Frame:Double Pane with Low-E 32 0.650 21 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Back Projection factor: 0.33 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 135 deg. from North; Comp. orient.: Back Projection factor: 0.81 Wall 4: Wood Frame, 16" o.c. 392 13.0 0.0 28 Window 4: Metal Frame:Double Pane with Low-E 47 0.650 31 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Floor 1: Unheated 192 0.0 200 Insulation depth: 0.0' COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REeckVe�sion 3.5 Release lb (formerly MECchec� and to comply with the mandatory requirements listed in the RES checklns ection Chkklist. \ Builder/Designer�GG��/ ` (SG°�/�� Date�65