Loading...
HomeMy WebLinkAboutACC2005-03755�S- 3.1�, ACCFa£SORW/STORAGE PERMIT CITY OF COLLEGE STATION 1101 TEXAS -AVENUE COLLEGE STATION, TEXAS 77840 PHONE:(979) 764-3570 FAX: (979) 764-3496 Application Number . . . . . Property Address . . . . . . Property ID: R #• Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner 05-00003755 1118 WESTOVER ST 183500-0010-0100 R21117 ACCESSORY/STORAGE CARTER'S GROVE RESIDENTIAL UNKNOWN 15600 Contractor Date 10/21/05 PATE, FRANCIS M, JR ROCKIN H CONSTRUCTION 1118 WESTOVER ST BARRI C,HOMEYER COLLEGE STATION TX 778402615 PO BOX 382 --- Structure Information 000 000 Construction Type . . . . . Occupancy Type . . . . Other struct info . . . . . CALVERT (979) 364-2930 ACCESORY WORK SHOP COMBUSTIBLE (UNPROTECTED) UTILITY AND MISCELLANEOUS TAZ TX 77837 226.00 ---------------------------------------------------------------------------- Permit . . . . . . ACCESSORY/STORAGE PERMIT Additional desc . . KW Permit Fee . . . . 90.00 Plan Check Fee .00 Issue Date . . . . 10/21/05 Valuation . . . . 15600 Expiration Date . . 4/19/06 Qty Unit Charge Per Extension BASE FEE 15.00 15.00 5.0000 THOU BLDG, VAL 1001-50000 75.00 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code.& LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - BUILDING DEPT. REPRESENTATIVE: - - - -� - r - APPLICANT: ACCESSORY/STORAGE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 PHONE:(979) 764-3570 FAX: (979) 764-3496 Page 2 Application Number . . . . . 05-00003755 Date 10/21/05 ---------------------------------------------------------------------------- Special Notes and Comments ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Fee summary Charged ----------------- ---------- Permit Fee Total 90.00 Plan Check Total .00 Grand Total 90.00 Paid Credited Due 90.00 .00 .00 .00 .00 .00 90.00 .00 .00 -��4 ------------------------- BUILDING DEPT. REPRESENTATIVE: APPLICANT : vo" CITY OF COLLEGE STATION Planning d Development'Serviat ADDRESS/LOCATION: APPLICATION IFOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WVWV.CSTX.GOV vrr . Fa ptryc Use ONy GATE: � G APPLICATION # TEMP POLE .# i eo n LOT BLOCK SUBDIVISION SEC/PH BUSINESS/OWNER NAME: .. 4c-.k n �,. (5 �, . PHONE: .R?1 -71 638 CONTRACTOR/HOMEOWNER: AQz" NoPHONE:'17y 36y-(51�34? CONTRACTOR ADDRESS: kve-4 7 r -71 `k31 ELECTRICIAN: PLUMBER: HVAC: GOOD CENTS (Residential only): CLASS OF WORK c ACCESSORY/STORAGE LOCATION. RE -ROOF ADDITION MOVING SHELL ONLY %(,q .07 3 0 DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL 111 Required) DESCRIPTION OF WORK: .STRUCTURE USE: e f HOMEOWNER ASSOCIATION/ARCHIT CTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 15 (100:° a TOTAL AREA: (,00 S1 HEATED AREA: (Cost o Lat,or and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: ❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: SEWER TAP: INTERIOR WALL TYPE: SIZE a WATER TAP: EXTERIOR WALL TYPE: SIZE OTHER TAP: FOUNDATION TYPE: SIZE TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE DOUBLEa TRIPLE' a ATTACHED DETACHED a CARPORT a SIGNATURE OF APPLICANT: I2Q,,.,;��y,r,,�,,�,� *If proposed work involves new commercial constructidfi or facade Improvements/renovations to an existing commercial property, building elevations are required. ' Official Use Onlyr 06c- -� ' 10 1I�IIDS DID 'DQ/ 7- YESmeNO Plans Examiner. Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of. ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating Ox P.O. BOX 382 1108 PIN OAK STREET CALVERT, TEXAS 77837 ROCKIN H CONSTRUCTION OFFICE: (979) 364-2930 MOBILE: (979) 777-9638 FAX: (979) 364-2658 FRANCES PATE OCT 18, 2005 1118 WESTOVER COLLEGE STATION, TX 77840 CONCERNING FOUNDATION: 20X30 SLAB -4" W / # 3@ 14"O/C EXTERIOR BEAM 14"X 30" W / # 6 STIRUPS 4' O/C INTERIOR BEAM 14" X 24" W / # 6 STIRUPS 4' O/C FRAMING: ➢ WILL BE FRAME WITH 2X4 WALLS 16" O/C WITH DOUBLE TOP PLATE ➢ BOTTOM PLATE WILL BE TREDED AND ANKERED WITH J BOLTS ➢ TRUSSES ON 24" O/C AND 2X4 LATHES ON 40" O/C ➢ GAVALUME METAL ROOF WITH LIGHT STONE WALLS AND TRIM (26 GUAGE METAL) ➢ BUILDING WILL HAVE ONE WALK DOOR AND A 16' GARAGE DOOR (2"X12" HEADER),ub� — La %Ai ng L 30p '40` M, U VL.(hfiiack Ggvra�c, 6toor hAr,5 O�e� 31L 410 WI' \)(H [• -�enC-(-- J� 2-® X 3 P"ew ev"%\6 ;n5 �c �O's ►�� 0 16 10-0-0 tae o 20-0.0 sa-0 5-4-0- a-e-a a-e-o sw� _ 3.00 12 4gs = 92t4 = tc4 = �+ g gg 13.2 10 20-" LOAWHG(pst] SPACING 2-0" 1 20.0 P18tm trtwue 1.15 TCa 10.0 lun bt ktr GM 1.15 BCLL 0.0 Rap S6eB9 kw YES BCOL. 10.0 C009 MC20ONW120M uA1eBER TOP CHORD 2 X 4 SYP He.2 SOT CHORD 2X4 SYP Hot WEBS 2X 4 SYP No.B REACnOH8 Qdeta) 478BI0-38. E=78810" MaX HWzA,420bad Use 3) max up9A=190ow cm Sh E-19008d was 9) CSI OEFL In (10c) 1►daR Lid PLATES GRIP YC 0.28 ve1(LL) om F-H a999 3W Wo 2441VA BC nw vergna .0.33 F-H >711 180 WS 021 Harz(TL) om E rda ft Now WafOttt 78 lb FORCES (b) - Ite9ldtntan O-F-dmd►tma —T—r - TOPCHC:FB=-2a791589.B'C5'2t151465•C-Os21t51S6s.D£�Z77915�3 OOTCHOFW WEBS 84$=,07/z75. C44--t09B021 C.F=1/0l802 DF-75 BWW. TOP CHORD SburdtM YY00d rttW9i09 4i+ecqY nppw ar al" oc pu m. SOT CHORD Rfl{d� d 9pPtad or B at2 oc 0ratfit9 NOTM 1) UnboWwad mot Eva wads love bean carsd&W for ots deEltyt. 0 C; enol0eed a1WFRS yabte wm tie: cmop erlelt and lipid 2) We,& Af# 7� 9QMk- =491t TCM,42P9t BCOL BDPA Cv"mY OOL=C e Gag_ :end vwe:t MR and right mmosed: L-79 t DOtj=1.3S pieta grip 2) 7tss hss bm damWad a 10A pet OaRa- dmM two toad nwwwcwted-M MW odte Cne 09 wmr Wit is � r QWu Oftt pet dte Tooth Carol bhoW Vahan *65 Nee tB cft0sa� for que9pr assur9rn to • o1 lh190 lb 6)) T b "M is d tW d �• Via 2M to �tBukWV Cade aec!°" 2M.1tW ��rowedd sbvd•M AANSVVTPI t.at)alnt E. LOAD CASEM Stattdatd ., ► 8ER K El-E Y STREET 44.1 to lod d Jt� E=c cnt t.: 6 7 Ts 7 sIr -ox76' WESTOVER STREET ------�2 E � �� . ►. .r.__ - - 10 r 1 t 12 13 14 15 1910.0o FIRST INSTALUIZNT OF ( REVISED) SUBDIVISION TR.F -CITY. .ni.-