Loading...
HomeMy WebLinkAboutADDN2005-037430� 3-�43 PREPARED 4/28/06, 7:56:35 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/27/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 2905 CORONADO DR SUBDIV: SOUTHWOOD FOREST ##1 CONTRACTOR NEW VISION CUSTOM HOMES, INC PHONE (979) 694-6886 OWNER VESTAL, TOM A & SUSAN S PHONE PARCEL 582500-0680-0030 APPL NUMBER: 05-00003743 RESIDENTIAL, ADDITION ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PBRMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 11/29/05 OC BLDG, FOUNDATION -SLAB TIME: 17:00 11/29/05 AP November 29, 2005 9:24:49 AM kwolfe early afternoon November 29, 2005 4:21:35 PM kwolfe strings on setback slab ground installed B115 01 1/18/06 JGM BLDG, FRAMING TIME: 17:00 1/18/06 AP January 18, 2006 8:14:58 AM kwolfe January 18, 2006 4:47:41 PM kwolfe 13130 01 2/02/06 RH BLDG, INSULATION TIME: 17:00 2/02/06 AP February 1, 2006 1:18:05 PM bkorthauer CALL 220-2325 BEFORE GOING OUT HOUSE IS OCCUPIED AFTERNOON Bt25 01 4/27/06 BI BLDG, FINAL TIME: 17:00 April 27, 2006 4:58:50 PM kwolfe 11 -------------------------------------- COMMENTS AND NOTES-------------------------------------- Date: 4/28/2006 Inspection Comments for Finals Permit Year: 5 Permit Number: 3743 Address: 2905 CORONADO DR Insp. inspection Type code Description Status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC November 29, 2005 4:21:35 PM kwolfe B100 BLDG, FOUNDATION -SLAB IC strings on setback B100 BLDG, FOUNDATION -SLAB IC slab ground installed B115 BLDG, FRAMING IC January 18, 2006 4:47:41 PM kwolfe Ell ELEC, ROUGH IN IC January 18, 2006 4:47:48 PM kwolfe M100 MECH, ROUGH IN IC January 18, 2006 4:47:34 PM kwolfe P105 PLBG, TOP OUT IC January 18, 2006 4:47:56 PM kwolfe P125 PLBG, FINAL IC April 20, 2006 1:09:02 PM kwolfe P125 PLBG, FINAL IC JR CALLED TO CANCEL Pagel WF0711972 / 001 Ci,,ty of College Station PAGE 1 REQ. DATE: 10/27/05 _ 10/27/05 9:25:00 LOCATION: 2905 CORONADO DR LOC ID: 139304 REQUESTOR: NEW VISION CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT SWR 4" WTR 3/411 ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/27/05 SCHED COMPLETION: 10/27/05 ******************************************************************************** JOB ORDER RESULT COMMENTS City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning 4/28/06 582500-0680-0030 2905 CORONADO DR COLLEGE STATION TX 778457718 SOUTHWOOD FOREST #1 SOUTHWOOD FOREST #1, BLOCK 68, LOT 3 SINGLE FAMILY RESIDENTIAL Owner . . . . . . . . . VESTAL, TOM A & SUSAN S Contractor . . . . . NEW VISION CUSTOM HOMES, INC 979 694-6886 Application number 05-00003743 000 000 Description of Work RESIDENTIAL, ADDITION Construction type . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . Approved 7BuiWing Official VOID UNLESS SIGNED BY BUILDING OFFICIAL G. BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS.. AVE COLLEGE STATIQN, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 05-00003743 Date 10/27/05 Property Address . . . . . 2905 CORONADO DR Property ID . . . . . . . . . 582500-0680-0030 R # . . . . . . . . . . . . . R83081 Application type description RESIDENTIAL, ADDITION Subdivision Name . . . . . . SOUTHWOOD FOREST #1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 85000 Owner Contractor ------------------------ VESTAL, TOM A & SUSAN ------------------------ S NEW VISION CUSTOM HOMES, INC 2905 CORONADO DR GUILLERMO TORRES JR COLLEGE STATION TX 778457718 P 0 BOX 86 WELLBORN TX 77881 (979) 694-6886 --- Structure Information 000 000 ADDITION Construction Type . . . . . COMBUSTIBLE (UNPROTECTED.) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) NONE HEATED AREA 1241.00 INTERIOR WALL TYPE SHEETROCK .NUMBER OF BATHROOMS 1.00 NUMBER OF BEDROOMS 1.00 SEWER TYPE PUBLIC TAZ 390.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit Fee . . . . 400.00` Plan Check Fee .00 Issue Date . . . . 10/27/05 Valuation . . . . 85000 Expiration Date 4/25/06 Qty Unit Charge Per Extension BASE FEE 260.00 35.00 4.0000 THOU BLDG, VAL 50001-100000 140.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS BUILDING DEPT REPRESENTATIVE: L�eJ APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS . AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 05-00003743 Page 2 Date 10/27/05 Special Notes and Comments METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS c BUILDING DEPT REPRESENTATIVE: APPLICANT: C2 z BUILDING PERMIT ° CITY OF COLLEGE STATION 1101 TEXAS-AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 05-00003743 Date 10/27/05 ---------------------------------------------------------------------------- Special Notes and Comments TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Narrow wall bracing fully sheathed with interior wall anchoring and bracing Move smoke detector out of bathroom area and into hallway ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged --------------------------- Paid Credited ------------------------------ Due Permit Fee Total 400.00 400.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1150.00 1150.00 .00 .00 BUILDING DEPT REPRESENTATIVE: — APPLICANT: �. A.PPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE ` COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764.3496 FAX Planning 6 Development'Servicer VVWW.CSTX.GOV ADDRESSILOCATION:���� rJGC�© /For Office Use Only DATE: APPLICATION # �� C4 3 TEMP POLE .# LOT .9 v BLOCK (ptJ ✓ SUBDIVISION SEC/PH . .� BUSINESS/OWNER NAME: . ' /U6 PHONE:��—��/Q CONTRACTOR/HOMEOWNER:dtS/Oyl����'PHONE: CONTRACTOR ADDRESS: orZZ7 7?��, . ELECTRICIAN: 63y �4 PLUMBER: X-6. HVAC: ,I` - GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION. RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ '14 �, �� TOTAL AREA: HEATED AREA:/AV/_ (Cost of Lab6r and Materials) 4,4 10�PUBLIC SEWER .❑ SEPTIC/TREATMENT SYSTEM ✓SEWER TAP: WATER TAP: S E � OTHER TAP: SIZE TEMP POLE SIZE GARAGE TYPE: SINGLE ATTACHED NUMBER OF BEDROOMS: NUMBER OF BATHROOMS INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: TRIPLE a p CARPORT r� / SIGNATURE OF APPLICANT: Ale *If proposed work involves new commVelal construction or facade improvements/renovations to an existing commercial property, building elevations are required. Official Use Onlv / /-�, - /4-Zo—aS- Plans Examiner 5'6 DOUBLE a IETACjKnD a Zoning Official ents:. Sjor NO 14.v Energy Code Compliance Information % Glazing of exterior walls (� Insulation R value of exterior walls 13 Insulation R value of ceiling I (flat areas) Insulation R value of. ceiling 2 (vaulted area attic) _ Glazing SHGC I Glazing U-Factor R value of ductwork Gj A/C SEER Rating IV 1 100 BUILDING SETBACK LINE 1 I I I I I 1 I I 1 I I I 1 I i I 1 I I i I 1 I I 1 1 wl I 1 YI wl zi I w. 01 { I QI ql wI: I o1 ze5 4 � I Lot I � k I 0, B .ILDING SETBACKr krfrE 1 61 TE FLAN R MENOG NONE SCAM I a&-'ol ,NORTH LOT: OB BLOCK: GB SUBDIVISION: SOUTHNOOI5 FORE5T PHASE 3-A COLLEGE STATION, TX BRAZOS COUNTY 44 PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Asnninj d Dwelopmint Sarvieu PLAN REVIEW/PERMIT NUMBER# 0S - BUILDING ADDRESS:3 , DATE: . ,? os CmO6( 1. Foundation Re uirements A. Concrete m{nimum f c of 3000 PSI Na B. Minimum four 4 inch slab thickness C. Va or barrier 1. 6 mil Poly D. Slab/beam or ier layout shown 1. Footin s/beams are continuous over the len th and width of foundation 2. Dimensions 3. r-- - i- ig s 30" exterior, 24" interior unless over 60' long then 30" 4. 82acing of beams does not exceed 15' E. Reinforcement details tome minimum re uirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement ------------------- 4. Mason fire lace foundation reinforcement F. Wood foundation details indicated II. Framin . Floor Wall, Ceilin and Roof to uirements N A. Girder or sill dimensions grade & species NA B. Floor 'oist sizespacing, grade & direction of spa n indicted on plans C. Treated sill Plate or bottom plate D. Narrow Wall Brac-Inc I Methods { ndicated on lans E. Header sizes indicated on laps F. Emer'llency bedroom egress 1. Exit direct to outside 2. Ooerabla wina u a i wen ty (20) inch clear width by twenty-four (24) inch clear heigh b. Maximum sill heigiht of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not arovid H. Stud grade and spacing I Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathin indicated on plans 3. Moisture barrier indicated on plans J. Roof framing plan or elevation shown K. Ceiling foist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in ara a it is not to exceed 30" x 54" M. Span exceeding' code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. i4N CITY OF COLLEGE STATION Planning d Divtlopmtntsavltn II. Framing: Floor, Wall, Ceiling and O. Roof Covering 1 R fD PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS of Requirements (continued) oo ecking indicatea on Diana, 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roc location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected opernngs on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes Stairway Requirements A. Stairway Details — 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft ei ht 6'-8" B. Winder details must have the size, grade & 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1 Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of se d 3. St 4. HE 5. AI D. Guards/h I. G at 2. H 3. H le 4. H $l 5. C 6. C r IV. Fireplace Reg, A. Hearth e 1. F yen an one-half (7-1/2) inches at a distance of twelve (12) :hes from the narrow edge iirway width not less thantwenty-six inches adroom required not less than six ft six (6'-6") inches treads must be identical indrail details required when a porch, deck, balcony or landing is thirty (30") inch( Trade or finished floor ils are required on stairways located four or more risers above floors ils must be thirty-four to thirty-eight (34-38) inches when measured edge of the tread Hs must not project more than four & one-half (4-1/2") inches into wi must be a minimum of thirty-six (36) inches above finished floor & handrails along open -sides) of stairway must have intermediate or uprights that prevent the passage of a four (4) inch sphere ants (to be indicated on plans) i✓. ynimneys must e least two (2) feet of a nmg < 6 sq, ft, (extensions• 8" & 16, forward) nine 6 sq. ft. (extensions 12" side & 20" forward) Wires 2" clearance from all combustible materials nd at least three (3) feet higher than the highest point f- roof & at her than any portion of the building within ten (10) feet horizontal PLAN REVIEW ONE and TWO FAMILY CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS Planning 6- D*wkpmmr Sawlca V. Electrical Service Re uirements A. Electrical Ian to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated Where -required 4. Are fault Drotection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed HN.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Ener y Requirements A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zonin Ordinance Requirements — Ordinance 850 Permitted use for district Density requirements Minimum lot size Setbacks Easements Re uired pamnes On zero lot side 18" max. overhang allowed Street Ordinance Requirements Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side intersectin street Subdivision Re ulations — Ordinance 690 A roved subdivision Plat filed Flood lain Re ulations — Ordinance 1301 Does not block any water course or divert any flow Elevation certificate if reauired CITY OF COLLEGE STATION Planning d Dnvlopmen► Sm ica Comments: PLANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS 2-o_o7. DATE r CM OF COLLEGE STATION P14HPI/ a d+Daa/apmMf &Pvka Storm Water Discharqe P Texas Pollution Discharge Elimination System General Permit NO TXR 150000, The State of Texas assumed regulatory authority over storm water discharges associated with construction activities, effective March 5, 2003. The regulatory requirements under the general .permit are based upon the area of land disturbed and are classified into two categories: Large Construction Activity: 5 or more acres of disturbed land or part of a larger common a development that will disturb 5 or more acres.,--g pl n of 1. Obtain a copy of TPDES GP No. TXR 150000 2. Develop and Implement a Storm Water Pollution Prevention Plan 3. Two days prior to the start of construction, submit a Notice of Intent to TCEQ 4. Provide a copy of the Notice of Intent to the City 5. Submit a Notice of Termination to TCEQ once the site has reached final stabilization Small Construction Activity: at least 1 but less than 5 acres, or is part of a larger common development that will disturb at least 1 but less than 5 acres. plan of 1. Obtain a copy of TPDES GP No. TXR 150000 2. Develop and implement a Storm Water Pollution Prevention Plan 3. Prior to starting construction, post a Construction Site Notice as in Part II.D.2 at the site 4. Provide a copy of the Construction Site Notice to the City Additional information can be obtained from: TCEQ Website: www.tnrcc.state.t cus/ ermittin /water erm/ww erm/construct.htmI#additional This website provides all associated documents and explanations including NOI, GP, etc. Compliance assistance can be obtained from: Donnie Willis Drainage Inspector . City of College Station 979-764-6375 dwillis@cstx.gov larger Common Plan of Development — A construction activity is part of a larger common plan of development If it. is completed in separate stages, separate phases, or in combination with other construction activities Example 1: A subdivision is being built. You are grading 0.75 acres, another company is clearing 4 different acres, and a contractor is excavating another 0.5 acres. In this case, the total area that would be disturbed is 5.25 acres, so each contractor would fall under the requirements associated with disturbing 5 or more acres. Example 2: At first, your project calls for you to grade, clear, or excavate a total of 0.93 acre. But after your project begins, you learn that you must disturb another 0.15 acre. Because this project has grown to disturb a total of 1.08 acres, you must obtain coverage under the requirements for disturbing 1 to less than 5 acres.