Loading...
HomeMy WebLinkAboutADDN2005-037410 1 I=nspeeaion 'Inquiry Cisty,'of _Co`lleg,e St,atiorn,F; Nip Herne i Now Winder.,I Support Inspection Inquiry"'sl' i i Help Property ID: ProperrV Information 497906-0043-0110 Property address: 5120 BELLERIVE BEND DR Application,.structure number. Application I Permit Information .05 00003741 .000 000 Permit type, sequence number. BLDG 00 BUILDING PERMIT Inspection type, sequence number Inspection Information B125 0001 BLDG, FINAL Inspection status, date: INSPECTION COMPLETED 4121/06 Requested date, time, by. - 4/21106 17:00 KW Override date, time, by: User ID to request, result: KWOLFE JGM Phone Interface number. 8941.39 Inspector assigned: JGM JOHN MALDONADO Results status, date: APPROVED 4121106 Final Inspection flag: Y Penalty amount: Mo !April 21;:; 2006 2;e;25.08; IPM 'kwo'lfe. _ City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F C O M P L E T I O N P E R M A N E N T Issue Date . . . . . . Parcel Number . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning 3mMI: 497900-0043-0110 5120 BELLERIVE BEND DR COLLEGE STATION TX 77845 PEBBLE CREEK PEBBLE CREEK VA, BLOCK 43, LO T 11 SINGLE FAMILY RESIDENTIAL Owner . . . . . . . . . BIZON, JENNIFER L & BARRY Contractor . . . . . . INTERIORS BY JOAN 979 567-9371 Application number 05-00003741 000 000 Description of Work RESIDENTIAL, ADDITION Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . Approved . I -Al ding fficial VOID UNLESS SIGNED BY BUILDING OFFICIAL BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX.77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 05-00003741 Date 10/20/05 Property Address . . . . . . 5120 BELLERIVE BEND DR Property ID: 497900-0043-0110 R #: R105264 Application type description RESIDENTIAL, ADDITION Subdivision Name . . . . . . PEBBLE CREEK Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 98000 Owner Contractor ------------------------ ------------------------ BIZON, JENNIFER L & BARRY INTERIORS BY JOAN SETLOW JOAN ROCKETT 5120 BELLERIVE BEND DR P.O. BOX 388 COLLEGE STATION TX 778454477 CALDWELL TX 77836 (979) 567-9371 --- Structure Information 000 000 ADDITION Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE ' BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 278.00 INTERIOR WALL TYPE SHEETROCK SEWER TYPE PUBLIC TAZ 411.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit Fee . . . . 452.00 Plan Check Fee .00 Issue Date . . . . 10/20/05 Valuation . . . . 98000 Expiration Date . . 4/18/06 Qty Unit Charge Per Extension BASE FEE 260.00 48.00 4.0000 THOU BLDG, VAL 50001-100000 192.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS --------------------- - --- - ---- -------------------------- BUILDING DEPT REPRESENTATI/vE. APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 05-00003741 Date 10/20/05 ---------------------------------------------------------------------------- Special Notes and Comments MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Assure proper plug spacing ---------------------------------------------------------------------------- Fee summary ----------------- Permit Fee Total Plan Check Total Grand Total Charged Paid Credited Due ---------------------------------------- 452.00 452.00 .00 .00 .00 .00 .00 .00 452.00 452.00 .00 .00 ---------------------------------- -n----11-/f-- a ------------------------- BUILDING DEPT aE,PRESENTA APPLICANT: BUILDING, PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . 05-00003741 ----------------------------------- BUILDING DEPTiRE.PRESENTATI)� APPLICANT: Page 3 Date 10/20/05 W"" CITY OF COLLEGE STATION Planning d• Developmenr'Servica APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764.3570 (979) 764.3496 FAX WVWV.CSTX.GOV ADDRESSILOCATION: / -C) I LOT I BLOCK -SUBDIVISION BUSINESS/OWNER NAME: .' v CONTRACTOR/HOMEOWNER: CONTRACTOR ADDRESS: _ ELECTRICIAN: HVAC: Fw O/fice U my DATEQ REG 41 APPLICATION # 1 TEMP POLE V SEC/PH PHONE: r 2-0 3( PHONE: PLUMBER: _ GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION . RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTIONSLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING POOL Required) DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ L TOTAL AREA: S-3 HEATED AREA: Ustof Labor and Materials) -� "t-o n PUBLIC SEWER NUMBER OF BEfIiS: .......... 'm .❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: r SEWER TAP: INTERIOR WALLTYPE: ,5/� SIZE a WATER TAP: EXTERIOR WALL TYPE: SIZE n OTHER TAP: FOUNDATION TYPE: ;S r/ � SIZE TEMP POLE ROOF TYPE: S� GARAGE TYPE: SINGLE DOUBLE' a TRIPLE ATTACHED a ETACHED � C PORT a SIGNATURE OF APPLICANT: *If proposed work involves new commercial onstruction or facade improvements/renovations to an existing commercial property, building elevations ar required. Offic/al Use Only - Plans Examiner or NO Zoning Official dyp /S0.. (:_01414, Q.✓f l . —��v5 Sfk..tiY� Energy Code Compliance Information % Glazing of exterior walls (� Insulation R value of exterior walls J3 Insulation R value of ceiling 1 (flat areas) a Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC • Div Glazing U-Factor R value of ductwork A/C SEER Rating �' PLAN REVIEW ONE and TWO FAMILY CITY OF COLi.EGE STATION OCCUPANCY REQUIREMENTS Amninl d Dsvelopmw Sorvica PLAN REVIEW/PERMIT NUMBER# BUILDING ADDRESS: DATE: /o / � 20 t4e11 ' I. Foundation Requirements A. Concrete minimum Pc of 3000 PSI IV B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier la out shown 1. Footin s/beams are continuous over the length and width of foundation 2. Dimensions i 3. Footings 30" exterior, 24" interior unless over 60' lang then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum re uirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fire lace foundation reinforcement F. Wood foundation details indicated II. Framin : Floor Wall, Ceiling and Roof Requirements A. Girder or sill dimensions grade & species A/ K B. Floor 'oist size s acing, grade & direction of span indicted on plans C. Treated sill Plate or bottom plate D. Narrow Wall Bracin Methods indicated on tans E. Header sizes indicated on plans F. Emer, jency bedroom egress 1. Exit direct to outside 2. O erable window a. Twen 20 inch clear width b twen -four 24 inch clear hei ht b. Maximum sill height of to -four 44 inches above finished floor G. O erable bathroom window re quired when mechanical ventilation is not provided H. Stud rade and acin I. Exterior wall details 1. Exterior wall coverin indicated on plans 2. Sheathin indicated on Ians 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling'joist size s acin rade and direction of span indicated on Plans L. Attic access location and size indicated on plans A. If located in aaram it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered 11 N. Rafters sizes s acin rade slo a and urlins if required. 1 17, � PLAN REVIEW ONE and TWO FAMILY CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS Planning d Devilopmtnt savltn II. Framing: Floor, Wall, Ceiling and Root Requirements (cont O. Roof Covering 1. Roof Decking indicated on plans 2. Moisture barrier indicated on plan.4 P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes III. StairwaY, Re ulrements A. Stairway Details 1. Maximum riser hei ht 7-3/4 inches 2. Minimum tread width 10 inches 3. S&--*- vay risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. ei ht B. Winder details 1. Treads a minimum of six 6) inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow ed e C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches Z. Treads a minimum of seven and one=half (7-1/2) inches at a distance of twelve (12) inches from the narrow ednP 3. 4. less than twenty-six in( i not less than six ft six 5. Rn treads must be identical D. Guards/handrail details 1. Guards required when a porch, above grade or finished floor 2. Handrails are required on stain 3. Handrails must be thirty-four to leading edge of the tread deck, balcony or landing is thirty (30") inches lays located four or. more risers above floor/grade thirty-eight (34-38) inches when measured from the Handrails must not project more than four & one-half (4-1/2") inches into width of a stnirwnv 5. Guards must be a mini 6. Guards & handrails alc railing or uprights that . Fireplace Requirements (to be Ind 1. Fireplace opening < 6 2. Fireplace opening > 6 B. Masonry f Q. Chimneys least two m of thirty-six (36) inches above finished floor open -sides) of stairway must have intermediate went the passage of a four (4) inch sphere led on Dlansl :8"&16" 12" side Eiace requires 2" clearance from all combustible materials must extend at least three (3) feet higher than the highest point of roof & at 2) feet higher than any portion of the building within ten 00) feet horizontal 0 A A PLAN REVIE W ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION Planning 6- Dt k?mmt &n1ca V. Electrical Service Requirements A. Electrical elan to inrii itio• 1. wectrical fixtures & switches indicated 2. Smoke detector locations) indicated as required I GFI circuits indicated where required 4. Are fault protectlon for bedroom circuits S. Panel and Meter location 'I. Plumbing Requirements A Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage Ill. Mechanical Requirements Av All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside (excludes ductless units) B. Attic installed HN.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vlll. Energy Requirements A. Compliance software worksheet (REScheck) submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 8 Permitted use for district size Setbacks On zero lot side 18" max. overhang allowed Street Ordinance Requirements Maximum drive width for residence is 28' (combined Minimum 20 feet from driveway to side (intersectind Subdivision Regulations — Ordinance 690 at ;Dgulaxlons — Ordinance 1301 not block any water course or divert any flow tion certificate I reauired CITY OF COLLEGE STATION Planntnd d Dnvlopmm► Snvlra nts: PLANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS /o —2,0 -og— DATE CITY OA COLLEGE STATION P/anniq d' DtwJopmmt &,V1,, rm Water Discharge P Texas Pollution Discharge Elimination System General Permit NO TXR 150000, The State of Texas assumed regulatory authority over storm water discharges associated with construction activities, effective March 5, 2003. The regulatory requirements under the general .permit are based upon the area of land disturbed and are classified Into two categories: Large Construction Activity: 5 or more acres of disturbed land or part of a com no development that will disturb 5 or more acres. lamer n plan of 1. Obtain a copy of TPDES GP No. TXR 1b0000 2. Develop and Implement a Storm Water Pollution Prevention Plan 3. Two days prior to the start of construction, submit a Notice of Intent to TCEQ 4. Provide a copy of the Notice of Intent to the City 5. Submit a Notice of Termination to TCEQ once the site has reached final stabilization Small Construction Activity: at least 1 but less than 5 acres, or is part of a larger common plan of development that will disturb at least 1 but less than 5 acres. 1. Obtain a copy of TPDES GP No. TXR 150000 2. Develop and implement a Storm Water Pollution Prevention Plan 3. Prior to starting construction, post a Construction Site Notice as in Part II.D.2 at the site 4. Provide a copy of the Construction Site Notice to the City Additional information can be obtained from: TCEQ Website: www.inrcc.state.tx.us/permitting/ itererm/ww erm/construct.html#additional This website provides all associated documents and explanations including NOI, GP, etc. Compliance assistance can be obtained from: Donnie Willis Drainage Inspector . City of College Station 979-764-6375 dwillis@cstx.gov L_ steer Common Plan of Development — A construction activity is part of a larger common plan of development if it is completed construction activities in separate stages, separate phases, or in combination with'other Example 1: A subdivision Is being built. You are grading 0.75 acres, another company is clearing 4 different acres, and a contractor is excavating another 0.5 acres. In this case, the total area that would be disturbed Is 5.25 acres, so each contractor would fall under the requirements associated with disturbing 5 or more acres. Example 2: At first, your project calls for you to grade, clear, or excavate a total of 0.93 acre. But after your project begins, you learn that you must disturb another 0.15 acre. Because this project has grown to disturb a total of 1.08 acres, you must obtain coverage under the requirements for disturbing 1 to less than 5 acres.