Loading...
HomeMy WebLinkAboutADDN2005-03739OS- 373y is 0 i Inspection Results Entry - City of College Station Inspection Results: Entry Application number, type: Structure, permit: Inspection type, sequence: Property address: Request date, time, by - Inspector ID: Results date: 05 00003739 RESIDENTIAL; ADDITION 000 000 BLDG 00 8125 cool BLDG, FINAL 6011 AUGUSTA CIR 1131/06 17:00 KW JGM 01/31/2006 �� Results status: Final Inspection flag: Y j► (x' Edit comments l'+ Display Inspection penalties Point value: f 1 Nome i Now Window Support Eusail 1 I Nnip City of College Station 1101 =XAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F C O M P L E T I O N P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning Owner . Contractor 1/31/06 497900-0018-0080 6011 AUGUSTA CIR COLLEGE STATION TX 77845 PEBBLE CREEK PEBBLE CREEK #2B, BLOCK 18, LO T 8 SINGLE FAMILY RESIDENTIAL JACKSON, THOMAS WILLIAM & RICKY ARCHER 979 774-7665 Application number 05-00003739 000 000 Description of Work RESIDENTIAL, ADDITION Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . Approved . . . . . . . ts�iaing uiziciai VOID UNLESS SIGNED BY BUILDING OFFICIAL BUILDING PERMIT CITY OP—C'(7ItLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Property Address . . . Property ID: R #: Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . Owner 05-00003739 Date 10/20/05 6011 AUGUSTA CIR 497900-0018-0080 R93874 RESIDENTIAL, ADDITION PEBBLE CREEK RESIDENTIAL SINGLE FAMILY RESIDENTIAL 25000 JACKSON, THOMAS WILLIAM & SUSAN KAY 6011 AUGUSTA CIR COLLEGE STATION TX 778458985 Contractor RICKY ARCHER 9383 WEEDON LOOP BRYAN TX 77808 (979) 774-7665 --- Structure Information 000 000 ADDITION Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 280.00 INTERIOR WALL TYPE SR NUMBER OF BATHROOMS 1.00 NUMBER OF BEDROOMS .10 SEWER TYPE PUBLIC TAZ 411.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit Fee . . . . 135.00 Plan Check Fee .00 Issue Date . . 10/20/05 Valuation . . . . 25000 Expiration Date . . 4/18/06 Qty Unit Charge Per Extension BASE FEE 15.00 24.00 5.0000 THOU BLDG, VAL 1001-50000' 120.00 ---------------------------------------------------------------------------- Special Notes and Comments ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S - --------------------------------------- - ---� --------------------------- BUILDING DEPT�REPRESEUTATIJE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 05-00003739 Date 10/20/05 ---------------------------------------------------------------------------- Special Notes and Comments ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY'LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Need to verify floor joists sizes are adequate to support new upstairs rooms Assure plug spacing meets code in new storage area leading to new craft room Fee summary Charged ----------------- ---------- Permit Fee Total 135.00 Plan Check Total .00 Paid Credited Due 135.00 .00 .00 .00 .00 .00 ----------------------------------------- - - ------ -------------------- BUILDING DEPTHREfESFKNTATI�E APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 05-00003739 Date 10/20/05 Grand Total 135.00 135.00 .00 .00 ------------------------------------------- - ---� ----------------------- BUILDING DEPT NEPRFSEkFATIV%: - APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764.3496 FAX Planning 66 Developmme'Servicer For Office Use ONy GATE: � G APPLICATION # TEMP POLE .# WVWV.GSTX.GOV ADDRESS/LOCATION: LOT :9 1 BLOCK ___LV- SUBDIVISION f� �)t ( •e, ro p .K SEC/PH,� BUSINESS/OWNER NAME: J�4 4 11 II- PHONE: ZO-3P CONTRACTOR/HOMEOWNER: Ki w py' PHONE:$zD- CONTRACTOR ADDRESS: 939 3; 11 1,0,0 Aa, 1 ,ten.^ )i'i. L N ti e-.* a, r ELECTRICIAN: —)�o c� r I L PLUMBER: / A HVAC: ;O)C GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION . RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION* SWIMMING POOL Required) 1 DESCRIPTION OF WORK:�>"ext }�Lc►0 to f STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (fAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ vZ,5, D n b }� (Cost 6f Labor and Materials) �J PUBLIC SEWER '(I [ F-] SEPTIC/TREATMENT SYSTEM SEWER TAP: SIZE a WATER TAP: SIZE OTHER TAP: SIZE TOTAL AREA:,?96 HEATED AREA: NUMBER OF BEDROOMS: NUMBER OF BATHROOMS INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: a TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE F-� DOUBLE' a ATTACHED a DETACHED Q S k&.,tc �n1 G(C A, r TRIPLE a CARPORT a 1-1 U3 SIGNATURE OF APPLICANT: *If proposed work involves new conimerc' I constru ion or facade improvements/renovations to an existing commercial property, building elevations are required. Ofclal Use Only �oS� Yents: ES o NO Plans Examiner Zoning Official J10Fg, T0CS-7y n Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of. ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating PLAN REVIEW ONE and TWO FAMILY CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS Afanninj d D'Vilopmrnt $mica PLAN REVIEW/PERMIT NUMBER# BUILDING ADDRES os- S. DATE: o Izo l�- o/IAv v I. Foundation Requirements A. Concrete minimum f'c of 3000 PSI NA/ B. Minimum four 4 inch slab thickness C. Va or barrier 1. 6 mil of D. Slab/beam or ier la out shown 1. Footin s/beams are continuous over the length and width of foundation 2. Dimensions i 3. Footin s 30" exterior, 24" interior unless over 60' long then 30" 4. R-1-ingi of beams does not exceed 15' E. Reinforcement details to meet minimum re uirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framin : Floor Wail, ,1 11 !j 11 1 11 ilIinq and Roof Re uirements A. Girder or sill dimensions rade 8s ecies N B. Floor joist spacingL.cingrade & direction of s an indicted on lans C. Treated sill late or bottom late D. Narrow Wall Bracin Methods indicated on tans E. Header sizes indicated on pians F. Emer pncy bedroom egress 1. Exit direct to outside able window a. Twen 20 inch clear width b twen -four 241 inch clear height b. Maximum sill hei ht of fo -four 44 inches above finished floor G. O erable bathroom window re wired when mechanical ventilation is H. Studgrade and s acing not rovided I. Exterior wall details 1. Exterior wall covering indicated on lans 2. Sheathilli i indicated on lans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling'oast -size, spacing,grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located In are a it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes s acingrade, slo a and pudins if required. .'A `7. � PLAN REVIEW ONE and TWO FAMILY CITY OF COLLEGE STATION OCCUPANCY REQUIREMENTS Plannlnj d Drvelopmrnt Srrviet$ -raming: Floor, Wall Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans, 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass re uired in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes Stairway Requirements A. Stairwav main le . iwaximum user hei it 7-3/4 inches 2. Minimum tread width 10 inches 3. 011-:-..-y risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six,(6) inches on narrow ed e 2. Treads a minimum of ten (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser hei ht less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one=half (7-1/2) inches at a distance R_ twelve (12) inches from the narrow ed e 3. StairwaY width not less than twen -six inches 4. Headroom required not less than six ft six 6'-6" inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above cirade or finished floor 2. Handrails are ramuired on stairwa s located four or. more risers above floor/ rade J. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than our & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thi -six 36 inches above finished floor 6. Guards & handrails along open -sides) of stairway must have intermediate railing or uprights that mevent the naqqnna of a four 4 inch s here IV. Fireplace Requirements (to be Indicated on plans) A Hearth 9Xtenainnc 1. Fireplace opening < 6 sq, ft, (extensions: 8" & 16" forward) Y. Fireplace opening > 6 sq. ft. (extensions 12" side & 20" forward) B. Masonry fireplace requires 2" clearance from all combustlble materials 0. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two (2) feet higher than any portion of the building within ten (10) feet horizontal A V4" CITY OF COLLEGE STATION Planning + Drwkpmmr Smica V. Electrical Service Real. PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS 1. Electrical fixtures & switches indicated 2. Smoke detector location(s) indicated as required 3. GFI cirCuitS indicated wham rani fired 4. Are fault Drotection for bedroom circuits S. Panel and Meter location VI. Plumbing Requirements A Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements A All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside (excludes ductless units) B. Attic installed HN.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equip ment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) VIII. Ener Requirements A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements Maximum drive width for residence is 28' (combined Minimum 20 feet from ddvewav to side (intersectinn, ubdiviston Regulations —Ordinance 690 lain Kegulations — Ordinance 13o Does not block any water course or Elevation certificate 9 reauired any flow PLAN REVIEW ONE and TWO FAMILY CITY OP COLLEGE STATION OCCUPANCY REQUIREMENTS A Hind d Dtwlopmmr &rvlea PLANS EXAMINER DATE J CITY OF COLLEGE STATION Planning d*Dvw1opmmr &rukrr rm Water Discharge Per Texas Pollution Discharge Elimination System General Permit NO TXR 150000, The State of Texas assumed regulatory authority over storm water discharges associated with construction activities, effective March 5, 2003. The regulatory requirements under the general .permit are based upon the area of land disturbed and are classified into two categories: Large Construction Activity: 5 or more acres of disturbed land or part of a common development that will disturb 5 or more acres. lamer plan of 1.Obtain a copy of TPDES GP No. TXR 150000 2. Develop and implement a Storm Water Pollution Prevention Plan 3. Two days prior to the start of construction, submit a Notice of Intent to TCEQ 4. Provide a copy of the Notice of Intent to the City S. Submit a Notice of Termination to TCEQ once the site has reached final stabilization Small Construction Activity: at least 1 but less than 5 acres, or is part of a larger common plan of development that will disturb at least 1 but less than 5 acres. 1.Obtain a copy of TPDES GP No. TXR 150000 2. Develop and implement a Storm Water Pollution Prevention Plan 3. Prior to starting construction, post a Construction Site Notice as in Part II.D.2 at the site 4. Provide a copy of the Construction Site Notice to the City Additional information can be obtained from: TCEQ Website: www.tnrcc.state.tx.us/-rmittin /water erm/ww erm/construct.html#additional This website provides all associated documents and explanations including NOI, GP, etc. Compliance assistance can be obtained from: Donnie Willis Drainage Inspector . City of College Station 979-764-6375 dwillis@cstx.gov Larger Common Plan of Development - A construction activity is part of a larger common plan of development if it. is completed in separate stages, separate phases, or in combination with 'other construction activities Example 1: A subdivision is being built. You are grading 0.75 acres, another company is clearing 4 different acres, and a contractor is excavating another 0.5 acres. In this case, the total area that would be disturbed Is 5.25 acres, so each contractor would fall under the requirements associated With disturbing 5 or more acres. Example 2: At first, your project calls for you to grade, clear, or excavate a total of 0.93 acre. But after your project begins, you learn that you must disturb another 0.15 acre. Because this project has grown to disturb a total of 1.08 acres, you must obtain coverage under the requirements for disturbing 1 to less tharl 5 acres.