HomeMy WebLinkAboutSLAB2005-03726WF0712461 / 001 City of College Station
PAGE ' 1
REQ. DATE:
10/28/05
10/28/05
13:15:41
LOCATION:
4331 SPRING GARDEN DR
LOC ID:
202064
REQUESTOR:
MAIN STREET HOMES ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
10/28/05 SCHED COMPLETION:
10/28/05-
JOB ORDER RESULT CONIlKEIQTS
'} BUILDING PERMIT
CITY'bF--00LLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . .
Property Address . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . .
Property Use . . . . . . .
Property Zoning . . . . . .
Application valuation . . .
Owner
05-00003726 Date 10/24/05
4331 SPRING GARDEN DR
582881-0101-0160
R****
SLAB ONLY RES. (SF)
SPRING CREEK GARDENS PH 1
RESIDENTIAL
PLANNED DEVL HOUSING
7270
Contractor
--7 ---------------------
MAIN STREET HOMES
PETER L DAVIS
7447 BEE CAVE ROAD #150
AUSTIN TX 78746
(979)
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc KW
Permit Fee 50.00
Issue Date . . . 10/24/05
Expiration Date . . 4/22/06
Qty Unit Charge Per
Plan Check Fee . . .00
Valuation . . . . 7270
BASE FEE
7.00 5.0000 THOU BLDG, VAL 1001-50000
Extension
15.00
35.00
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
Per section R106.3.3, 2003 IRC and section 106.3.3 2003
IBC, proceed with foundation work at own risk without
assurance that further permits will be issued.
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
BUILDING DEPT -1—REPRESEN7A-�IVE:
APPLICANT:
`L BUILDING PERMIT
CITT OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . .05-00003726 Date 10/24/05
----------------------------------------------------------------------------
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL: FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 50.00 50.00 .00 .00
Plan Check Total .00 .00 .00 .00
Grand Total 50.00 50.00 .00 .00
BUILDING DEPT R3-RESENTA.T-�VE :
APPLICANT:
CITY OF COLLEGE STATION
Planning & Deutbpment Servita
ADDRESSILOCATION:
LOT Ito✓BLOCK
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764.3570 (979) 764-3496 FAX
WWW.CSTX.GOV
Pot Ofte use only
DATE: I he]N�cQREG
07
APPLICATION # V�
TEMP POLE .#
Sprinecreek Gardens SEC/PH_ �T
BUSINESS/OWNER NAME: PHONE: '
CONTRACTOR/HOMEOWNER: Main Street, Ltd. PHONE:512-327-8620
CONTRACTOR ADDRESS: 7447 Bee Caves Rd. Austin, TX 78746
ELECTRICIAN: _ Hillco .Electric PLUMBER: Bass Plumbing
HVAC: Barkers HVAC GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL
Required)
DESCRIPTION OF WORK: Construct Single Family Residence
.STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY �AS) PROJECT REGISTRATION# EABPRJ
2-VALUATION: $ '/ � TOTAL AREA: _k6nj. HEATED AREA: i,�
(Cost of Labor and Materials)
D PUBLIC SEWER
.0 SEPTIC/TREATMENT SYSTEM
a SEWER TAP:
M WATER TAP:
n OTHER TAP:
TEMP POLE
GARAGE TYPE:
4"
SIZE
3/4"
SIZE
SIZE
SINGLE
ATTACHED
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL'TYPE:
Wood/Sheetrock
EXTERIOR WALL TYPE: Wood/ •Masonary
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE'
DETACHE n a
Post Tension on Grade
Asphalt Shingles
TRIPLE
CARPORT 0
SIGNATURE OF APPLICANT: U .
*If proposed work involves new commercial construction or facade 'rltIprovementdkebovations to an existing
commercial property, building elevations are required.
-+444......... ....... ...........................��i�..��
Official Use Only ents:
Mr NO
Plans Examiner Zoning Official
�s 14 eA111 .
{•
Energy Code Compliance Information
% Glazing of exterior walls , b
Insulation R value of exterior walls -
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic) 2� -
Glazing SHGC c 3�
Glazing U-Factor IV
R value of ductwork lO
A/C SEER Rating 1 Z
R
I
REScheck Compliance Certificate
2000 IECC . .
REScheckSoftware Version 3.5 Release la
Data filename: F:\Root\Mainstreet\Share\Construction\MECcheck\1102.cck
TITLE: 1102
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 10/ 14/05
COMPANY INFORMATION:
Main Street Homes, Ltd.
COMPLIANCE: Passes
Maximum UA = 1567
Your Home UA = 1415
9.7% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.36
Gross
Area or Cavity
Perimeter R-Value
Permit Number
Checked By/Date
Glazing
Cont. or Door
R-Value U-Factor UA
Ceiling 2: Flat Ceiling or Scissor Truss
1102
0.0 30.0 34
Wall 1: Wood Frame, 16" o.c.
1680
13.0 0.0 123
Window 1: Metal Frame, Double Pane
143
0.640 92
SHGC: 0.36
Door 1: Solid
20
0.450 9
Door 2: Solid
19
0.450 9
Floor 1: Slab-On-Grade:Unheated
1102
0.0 1148
Insulation depth: 0.0'
Furnace 1: Forced Hot Air, 80 AFUE
Air Conditioner 4: Electric Central Air, 10 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release la (formerly MECchecl and to comply with the mandatory requirements listed in
the RES checkInspection Checklist. Al
Builder/Designer Date
REScheck Inspection Checklist
2000 IECC
REScheckSoftware Version 3.5 Release la
DATE: 10/ 14/05
TITLE: 1102
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 2: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation
Comments:
Above -Grade Walls:
[ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
[ ) 1. Window 1: Metal Frame, Double Pane, U-factor: 0.640
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
[ ] 1. Door 1: Solid, U-factor: 0.450
Comments:
[ ] 2. Door 2: Solid, U-factor: 0.450
Comments:
Floors:
[ J 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
1. Furnace 1: Forced Hot Air, 80 AFUE or higher
Make and Model Number
2. Air Conditioner 4: Electric Central Air, 10 SEER or higher
Make and Model Number
Solar Heat Gain Coefficient:
The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
[ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
[ ] Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] I Air filters are required in the return air system.
[ ] I The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
I
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
Swimming Pools:
[ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in
Inches by Pipe Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature ( F).
Up to 1„
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Piping System Types
Range F
2" Runouts
1" and Less
1.25"
to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)