Loading...
HomeMy WebLinkAboutSLAB2005-03726WF0712461 / 001 City of College Station PAGE ' 1 REQ. DATE: 10/28/05 10/28/05 13:15:41 LOCATION: 4331 SPRING GARDEN DR LOC ID: 202064 REQUESTOR: MAIN STREET HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 10/28/05 SCHED COMPLETION: 10/28/05- JOB ORDER RESULT CONIlKEIQTS '} BUILDING PERMIT CITY'bF--00LLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . Property Address . . . . . Property ID: R #. Application type description Subdivision Name . . . . . Property Use . . . . . . . Property Zoning . . . . . . Application valuation . . . Owner 05-00003726 Date 10/24/05 4331 SPRING GARDEN DR 582881-0101-0160 R**** SLAB ONLY RES. (SF) SPRING CREEK GARDENS PH 1 RESIDENTIAL PLANNED DEVL HOUSING 7270 Contractor --7 --------------------- MAIN STREET HOMES PETER L DAVIS 7447 BEE CAVE ROAD #150 AUSTIN TX 78746 (979) ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc KW Permit Fee 50.00 Issue Date . . . 10/24/05 Expiration Date . . 4/22/06 Qty Unit Charge Per Plan Check Fee . . .00 Valuation . . . . 7270 BASE FEE 7.00 5.0000 THOU BLDG, VAL 1001-50000 Extension 15.00 35.00 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES Per section R106.3.3, 2003 IRC and section 106.3.3 2003 IBC, proceed with foundation work at own risk without assurance that further permits will be issued. MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE BUILDING DEPT -1—REPRESEN7A-�IVE: APPLICANT: `L BUILDING PERMIT CITT OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 2 Application Number . . . . . .05-00003726 Date 10/24/05 ---------------------------------------------------------------------------- Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL: FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 50.00 50.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 50.00 50.00 .00 .00 BUILDING DEPT R3-RESENTA.T-�VE : APPLICANT: CITY OF COLLEGE STATION Planning & Deutbpment Servita ADDRESSILOCATION: LOT Ito✓BLOCK APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764.3570 (979) 764-3496 FAX WWW.CSTX.GOV Pot Ofte use only DATE: I he]N�cQREG 07 APPLICATION # V� TEMP POLE .# Sprinecreek Gardens SEC/PH_ �T BUSINESS/OWNER NAME: PHONE: ' CONTRACTOR/HOMEOWNER: Main Street, Ltd. PHONE:512-327-8620 CONTRACTOR ADDRESS: 7447 Bee Caves Rd. Austin, TX 78746 ELECTRICIAN: _ Hillco .Electric PLUMBER: Bass Plumbing HVAC: Barkers HVAC GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL Required) DESCRIPTION OF WORK: Construct Single Family Residence .STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY �AS) PROJECT REGISTRATION# EABPRJ 2-VALUATION: $ '/ � TOTAL AREA: _k6nj. HEATED AREA: i,� (Cost of Labor and Materials) D PUBLIC SEWER .0 SEPTIC/TREATMENT SYSTEM a SEWER TAP: M WATER TAP: n OTHER TAP: TEMP POLE GARAGE TYPE: 4" SIZE 3/4" SIZE SIZE SINGLE ATTACHED NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL'TYPE: Wood/Sheetrock EXTERIOR WALL TYPE: Wood/ •Masonary FOUNDATION TYPE: ROOF TYPE: DOUBLE' DETACHE n a Post Tension on Grade Asphalt Shingles TRIPLE CARPORT 0 SIGNATURE OF APPLICANT: U . *If proposed work involves new commercial construction or facade 'rltIprovementdkebovations to an existing commercial property, building elevations are required. -+444......... ....... ...........................��i�..�� Official Use Only ents: Mr NO Plans Examiner Zoning Official �s 14 eA111 . {• Energy Code Compliance Information % Glazing of exterior walls , b Insulation R value of exterior walls - Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) 2� - Glazing SHGC c 3� Glazing U-Factor IV R value of ductwork lO A/C SEER Rating 1 Z R I REScheck Compliance Certificate 2000 IECC . . REScheckSoftware Version 3.5 Release la Data filename: F:\Root\Mainstreet\Share\Construction\MECcheck\1102.cck TITLE: 1102 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 10/ 14/05 COMPANY INFORMATION: Main Street Homes, Ltd. COMPLIANCE: Passes Maximum UA = 1567 Your Home UA = 1415 9.7% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.36 Gross Area or Cavity Perimeter R-Value Permit Number Checked By/Date Glazing Cont. or Door R-Value U-Factor UA Ceiling 2: Flat Ceiling or Scissor Truss 1102 0.0 30.0 34 Wall 1: Wood Frame, 16" o.c. 1680 13.0 0.0 123 Window 1: Metal Frame, Double Pane 143 0.640 92 SHGC: 0.36 Door 1: Solid 20 0.450 9 Door 2: Solid 19 0.450 9 Floor 1: Slab-On-Grade:Unheated 1102 0.0 1148 Insulation depth: 0.0' Furnace 1: Forced Hot Air, 80 AFUE Air Conditioner 4: Electric Central Air, 10 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release la (formerly MECchecl and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Al Builder/Designer Date REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.5 Release la DATE: 10/ 14/05 TITLE: 1102 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 2: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation Comments: Above -Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: [ ) 1. Window 1: Metal Frame, Double Pane, U-factor: 0.640 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door 1: Solid, U-factor: 0.450 Comments: [ ] 2. Door 2: Solid, U-factor: 0.450 Comments: Floors: [ J 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number 2. Air Conditioner 4: Electric Central Air, 10 SEER or higher Make and Model Number Solar Heat Gain Coefficient: The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system. [ ] I The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. I Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] I Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: [ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F). Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)