HomeMy WebLinkAboutRES2003-03300 210 KARTEN LN BUILDING PERMITCS Goo 33cso
03 -330►
1•
10
I*
I.i
PREPARED
3/24/04, 11:59:16
INSPECTION TICKET PAGE 8
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE 3/24/04
------------------------------------------------------------------------------------------------
ADDRESS
. : 210 KARTEN LN
SUBDIV: EDELWEISS GARTENS PH 2
CONTRACTOR B A CATHEY LTD
PHONE (979) 255-7064
OWNER
EDELWEISS GARTEN VENTURE PHONE
PARCEL
244030-0203-0010
APPL NUMBER: 03-00003300 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
11/14/03 OC
BLDG, FOUNDATION -SLAB TIME: 17:00
11/17/03 AP
11/14/2003 11:21 AM SSTANLEY
setbacks per strings slab -ground @ right side
B01
12/10/03 DS
BLDG, FRAMING TIME: 17:00
:#
12/10/03 DP
12/10/2003 09:55 AM MALFORD
z
12/11/2003 08:42 AM MALFORD
house built on setbacks not approved - all penetrations on
sidewall need to be removed
B115 02
12/12/03 DS
BLDG, FRAMING TIME: 17:00
12/12/03 AE
12/12/2003 09:49 AM GCARRILLO
B130 01
12/15/03 DS
BLDG, INSULATION TIME: 17:00
12/15/03 AP
12/15/2003 07:28 AM SSTANLEY
B125 01
3/24/04 BI
BLDG, FINAL TIME: 17:00
03/24/2004 08:32 AM MALFORD
----------------------------------- CONTINUED ONTO NEXT PAGE -----------------------------------
i�
City of College Station
WORK REQUEST PAGE 1
REQ/,TOB:,,r
WF0472770 /
001 PROJECT:
REQUEST
DPRINT ATE:
11%12%03
CREW:
PRINT TIME:
7:13:23
SCHEDULE
LOCATION:
210 KARTEN
LN
STTART:DATES
11/12/03
77845
COMPLETION:
11/12/03
GEN. LOC:
COLLEGE STATION LOC ID: 197440
REF NBR:
REQ DEPT:
DE -BUILDING
INSPECTION PRIORITY:
NORMAL
REQUESTOR:
B A CATHEY
LTD ORIGIN:
CUSTOMER -WALK
IN
USER ID:
MALFORD
AUTH: MALFORD WORK TYPE:
ROUTINE
TEMP POLE
PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
Description of Materials
•
U.S. Department of Housing
and Urban Development
Department of Veterans Affairs
Farmers Home Administrtation
HUD's• Approval No. 2502-0192 (exp. 04/30/2004)
and 2502-0313 (exp. 8/31/2001)
Public reporting burden for this collection of information is estimated to average 30 minutes per response, including the time for reviewing instructions, searching
existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. This agency may not collect
this information, and you are not required to complete this form, unless it displays a currently valid OMB control number.
The National Housing Act (12 USC 1703) authorizes insuring financial institutions against default losses on single family mortgages. HUD must evaluate the
acceptability and value of properties to be insured. The information collected here will be used to determine if proposed construction meets regulatory
requirements and if the property is suitable for mortgage insurance. Response to this information collection is mandatory. No assurance of confidentiality
Ox Proposed Construction Under Construction No
P ert address (Include City and State)
(To be inserted by HUD, VA or FmHA)
rop y
PNAse I, Fl_K I, f_oT5 II 1 )Z. 1✓QF_Lweiss G�arz S, co"-C--G6 41A,l TV -
Name and address of Mortgagor or Sponsor
McAfee Mortgage
311 Arguello Drive
College Station, Texas
Instructions
1. For additional information on how this form is to be submitted, number of
copies, etc., see the instructions applicable to the HUD Application for
Mortgage Insurance, VA Request for Determination of Reasonable Value,
or FmHA Property Information and Appraisal Report, as the case may be.
2. Describe all materials and equipment to be used, whether or not shown on
the drawings, by marking an X in each appropriate check -box and entering
the information called for each space. If space is inadequate, enter "See
misc." and describe under item 27 or on an attached sheet. The use of
paint containing more than the percentage of lead by weight
permitted by law is prohibited.
1. Excavation
Bearing soil, type
2. Foundations
Footings concrete mix 5 sack transit mix
Foundation wall material n/a
Interior foundation wall material.
Columns material and sizes n/a
Girders material and sizes -_n/a
Name and address of Contractor or Builder
B.A. Cathey, LTD
P.O. Box 9517
College Station, Texas 77842
3. Work not specifically described or shown will not be considered unless
required, then the minimum acceptable will be assumed. Work exceeding
minimum requirements cannot be considered unless specifically described.
4. Include no alternates, "or equal" phrases, or contradictory items. (Consid-
eration of a request for acceptance of substitute materials or equipment is
not thereby precluded.)
5. Include signatures required at the end of this form.
6. The construction shall be completed in compliance with the related drawings
and specifications, as amended during processing. The specifications include
this Description of Materials and the applicable Minimum Property Standards.
strength psi 3_0_OQ_psi __-- Reinforcing 3/8" rebar (a). 12 inch O.C.
Reinforcing n/a
_ Party foundation wall
Piers material and reinforcing n/a
Sills material
Basement entrance areaway n/a ---_—__—__—__—__—___ Window areawaysn/a __—_--_
Waterproofing 6 milpolyethelene Footing drains n/a
Termite protection Dursban TC __—___—__—_--__—_—__—__—__—__—__—__—_—___-----------------------
Basementless space ground cover n/ainsulation n/a _— _—_—__—__ foundation vents n/a—_—__--_—_
Special foundations _See foundation drawi___—_--__—__—_—
Additional information none
3. Chimneys
Material n/a
4.
Prefabricated (make and size) _n/a
Flue lining material _n/a _—__—__—_— Heater flue size n/a—__—__-- Fireplace flue size n/a_—__—__— --- —__
Vents (material and size) gas or oil heater n/a __--__—___—__—_—__—__— water heater n/a
Additional information none
Fireplaces
Type solid fuel gas-buming n circulator make and size
Fireplace facing _n/a lining _ n/ahearth n/a
Additional information none
Ash dump and clean-out_n/a _—
mantel _n/a
ref. HUD Handbook 4145.1 8 4950.1 form HUD-92005 (10/84)
Retain this record for three years Page 1 of 6 VA Form 26-1852 and form FmHA 424-2
•
5.
6.
Exterior Walls
Wood frame wood grade, and species 2x4 16" o_C. YP #2 Comer bracing Building paper or felt Felt
Sheathing Celotex or equal _ thickness 1/2" width 4 x 8 � solid F spaced __ O.C. � diagonal___
Siding none_`____ grade _n/a type n/a size exposure Na _� fastening n/a____
Shingles none_ ___ grade n/a _ type n/a size n/a __ exposure n/a__ fastening n/a
Stucco _none thickness _n/a ___ Lath weight _n/a _ lb.
Masonry veneer Brick Sills BrickLintels 3x3x1/4" steel _ Base flashing
Masonry ❑ solid 0 faced stuccoed total wall thickness 9 inches _ facing thickness 3 inches facing material Brick
Backup material none __thickness n/a _ bonding n/a
Door sills Aluminum `_ Window sills Wood __ Lintels steel Base flashing Galvanized Steel
Interior surfaces dampproofing, n/a
Additional information
coats of n/a
Exterior painting material Exterior_ Latex_
Gable wall construction a same as main walls nother
Floor Framing
furring n/a
number of coats
Joists wood, grade, and species n/a ______ other n/a _ bridging n/a anchors n/a _____
Concrete slab ❑ basement floor x❑ first floor F1 ground supported self-supporting mix n/a—_—___—_ thickness 5 inches__
reinforcing 3 8" rebar 1_ 2" o.c.Lee dwgSL_ insulation none _ __� membrane
Fill under slab material select fill _ thickness
Additional information See foundation drawings
7. Subflooring (Describe underflooring for special floors under Item 21)
Material grade and species _n/a __— ___ size n/a
Laid first floor nsecond floor ❑x attic 64.0 sq. ft. diagonal Ex right angles
Additional information
8. Finish Flooring (Wood only. Describe other finish flooring under Item 21)
type n/a
Location
Rooms
Grade
Species
Thickness
Width
Bldg. Paper
Finish
First floor
none
n/a
n/a
n/a
n/a
n/a
n/a
Second floor
none
n/a
n/a
n/a
n/a
n/a
n/a
Attic floor
none sq. ft.
n/a
n/a
n/a
n/a
n/a
n/a _
Additional information
9. Partition Framing
Studs wood, grade, and species 2x4 FJYP #2
Additional information
10. Ceiling Framing
Joists wood, grade, and species 2x6 #2 YP
Additional information
11. Roof Framing
Rafters wood, grade, and species 2x6 #2 YP
Additional information
size and spacing 2x4 stud walls at 16 o_c__ Other n/a _---_--_—.
Other 2x8 #2 YP Bridging 2x4 #2 YP
12. Roofing
Sheathing wood, grade, and species 7/16" OSB
Roofing Compostion/Shingle _ grade Class A
Underlay 30 Ib felt _____________,__ _
Built-up roofing n/a
Flashing material Galvanized sheet metal___
Additional information 25 year warranty
Roof trusses (see detail) grade and species none
solid El spaced n/a _ o.c.
size 36 inches type 3-tab fber. Ig ass
weight or thickness n/a size n/a__ fastening nailed
number of plies n/a—_ surfacing material n/a
gage or weight 27 gravel stops 0 snow guards
ref. HUD Handbook 4145.1 & 4950.1 form HUD-92005 (10/84)
Retain this record for three years Page 2 of 6 VA Form 26-1852 and form FmHA 424-2
13. Gutters and Downspouts
Gutters material none gage or weight n/a size n/a _ shape
Downspouts material _none gage or weight n/a ___ size n/a _ shape n/a number n/a __
Downspouts connected to ❑ Storm sewer sanitary sewer 0 dry -well Splash blocks material and size n/a
—--_--
Additional information
Rain gutters not provided
14. Lath and Plaster
Lath n walls n ceilings material n/a __ weight or thickness n/a Plaster coats n/a—finish _n/a--
Dry -wall ❑x walls � ceilings material gypsum board thickness 1/2 in finish _textured and paint__
Joint treatment tape and float
15. Decorating (Paint, wallpaper, etc.)
Rooms
Wall Finish Material and Application
Ceiling Finish Material and Application
Kitchen
textured and paint (beige with flat finish
textured and paint (off-white with flat finish)
Bath
same as above
same as above
Other(all other room:
same as above
same as above
Additional information none
16. Interior Doors and Trim
Doors type Pre hulk _____ material _masonite_________ thickness _1 3/8 inch _
Door trim type Finger Joint material _oneBase type FJ ___ material Pine size 3 inch _
Finish doors _Interior white latex paint semi gloss trim interior white latex with semi gloss finish__
Other trim (item, type and location) Interior white latex with semi gloss finish _____--__—_—__—_--_— —
Additional information none
17. Windows
Windows type Single hung _ make Alenco or equal material _Aluminum sash thickness n/a
Glass grade n/a sash weights nbalances, type _n/a head flashing n/a
Trim type Aluminummaterial Aluminum Paint 1DChit� _---� number coats iactory --
Weatherstripping type Plastic material _n/a Storm sash, number n/a
Screens R full a half type standard number all ___ screen cloth material synthetic
Basement windows type none ____` material n/a__screens, number n/a Storm sash, number n/a
Special windows none ---------_--__—_---_
Additional information none
18. Entrances and Exterior Detail
Main entrance door material Metal or Fiberglass _ width 36 in _ thickness 1.75 in Frame material Wood thickness _ 4.62_`.
Other entrance doors material Metal width _36 in _ thickness 1_75 in Frame material Wood thickness 4.625
Head flashing n/a ___�____ Weatherstripping type n/a ___ saddles n/a
Screen doors thickness n/a _ number _o/g_ screen cloth material n/a_ _ Storm doors thickness n/a__ number _n/a
Combination storm and screen doors thickness Na_ number n/a screen cloth material _n/a _
Shutters ❑ hinged F7 fixed Railings n/a Attic louvers (see drawings)
Exterior millwork grade and species_Paint none
Additional information none
number coats none
19. Cabinets and Interior Detail
Kitchen cabinets, wall units material Oak YeOeeL---__--_-------- lineal feet of shelves n/a __ shelf width n/a
Base units material Oak veneer counter top Plastic laminate edging _Plastic laminate
Back and end splash Plastic Yeaegr ___ Finish of cabinets Laguer ______ number coats 2
Medicine cabinets make
Other cabinets and built-in furniture
Additional information none
model
ref. HUD Handbook 4145.1 & 4950.1 form HUD-92005 (10/84)
Retain this record for three years Page 3 of 6 VA Form 26-1852 and form FmHA 424-2
•
•
20. Stairs
Treads
Risers
Strings
Handrail
Balusters
Stair
Material
Thickness
Material
Thickness
Material
Size
Material
Size
Material
Size
Basement
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Main
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Attic
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Disappearing make and model number Standard lumber yard inventory foldinq attic stair_____
Additional information none
21. Special Flo
- ta._k.... a m— Al— r--nnf — na#f 4 In CarriFarl Prnducfs nlrectorvl
Threshold
Wall Base
Underfloor
Location
Material, Color, Border, Sizes, Gage, Etc.
Material
Material
Material
o
Kitchen
CI,ILA M Ie— 1 t Wasn/a
n/a
n/a
k
Bath
CCX X �+ l G '► I if,
n/a
n/a
n/a
Breakfast
L� -t t7_&_
n
n
Family & BF
Carpet with 6 lb rebond pad
n/a
n/a
n/a
11__�
Heiy,c in shcx s
Location
Material, Color, Border, Cap. Sizes, Gage, Etc.
Height
Over Tub
(From Floor)
o
0
in
Bath
none
n/a
n/a
n/a
Additional information
22. Plumbing
Fixture
Number
Location
Make
MFR's Fixture Identification No.
Size
Color
Sink
1
Kitchen
Polar or equal
No. 4-33 stainless
6 inch deep
stainless
Lavatory
3
Bathrooms
Delta orequal MbRELE—
No. 2522
19 inch round
white
Water closet
2
Bathrooms
Crane orequal
No. 3-662
Standard
white
Bathtub
MBafih
MarZSL4
—
5EC 1>iV41
Shower over tub
Bathrooms
M 42f3 LE
60 x 32 x 72
white
Stall shower
t-4Arz-131.4:
W
Laundry trays
none
Bathroom accessories Recessed material n/a __ number n/a __ Attached material n/a number _n/a
Additional information Builder to provide kitchen garbage disposal, dishwasher, and water supply for refddgerator icemaker. Builder will
not supply curtain rods for showers.
Curtain rod Door FIShower pan material n/a Show and describe individual sjstem in complete detail in separate
drawings and spec cations according to requirements.)
Water supply � public 1-1community system � individual (private) system`
Sewage disposal a public F1 community system ❑ individual (private) system'
House drain (inside) 0 cast iron the other n/a _ House sewer (outside)EI cast iron ❑ the ❑ other n/a___
Water piping galvanized steel 0 copper tubing other n/a ________ _ Sill cocks, number _ see dwg_
Domestic water heater type _ 50_gallon____ make and model standard inventory Supply heating capacity gph. 100' rise.
Storage tank material capacity 5O ___ gallons
Gas service utility company ❑ liq. pet. gas D other none
Footing drains connected to storm sewer sanitary sewer
capacity Na discharges into
Additional information none
____ ❑ Gas piping ❑ cooking
❑ dry well F Sump pump make and model n/a
house heating
ref. HUD Handbook 4145.1 & 4950.1 form HUD-92005 (10/84)
Retain this record for three years Page 4 of 6 VA Form 26-1852 and form FmHA 424-2
0
23. Heating
Hot water Steam Vapor One -pipe system 0 Two -pipe system
Radiators Convectors n Baseboard radiation Make and model n/a
Radiant panel F1 floor wall ❑ ceiling Panel coil material n/a
1-1 Circulator ❑ Return pumpMake and model n/a --
Boiler make and model n/a ---- --
Additional information none
_-- — capacity _n/a gpm.
Output n/a --- Btuh. net rating _n/a -- Btuh.
Warm air nGravity a Forced Type of system Central air —_----------------
Duct material supply Flex duct — return Duct board -- Insulation R-6 _ thickness 1-5 finch Outside air intake
Furnace: make and model Make and model to be determined ------ Input TBD--- Btuh. output TBD --_ Btuh.
Additional information 10 SEER air conditioning -make and model to be determined
Space heater floor furnace wall heaterinput n/a Btuh. output n/a —_--_ Btuh. number units n/a
Make, model n/a
Additional information none
Controls make and types Make and model to be determined
Additional information none
Fuel: Coal ❑ oil gas ❑ liq. pet, gas o electric other n/a------__—_ storage capacity �La _---
Additional information
none
Firing equipment furnished separately RGas burner, conversion type RStoker hopper feed bin feed
Oil burner Opressure atomizing Rvaporizing n/a----_----- ---------_----_------
Make and model n/a ---------___------__-------_------- —
Control _ n/a
Additional information none
Electric heating system type to be determined
Additional information none
Input TBD —_ watts @ TBD volts output TBD --- Btuh.
Ventilating equipment attic fan, make and model _none -- _ --____---_ capacity n/a _—_ cfm.
0 kitchen exhaust fan, make and model vent fan included with overhead cooktgp microwave -----
Other heating, ventilating, or cooling equipment roof ridge vents�sof lit vents, ceilinq fans, and bathroom exhaust fans — --_
Additional information none
24. Electric Wiring
Service x❑ overhead Funderground Panel ❑ fuse box circuit -breaker make not available— AMP's not avail No. circuits n/a
Wiring ❑ conduit armored cable a nonmetallic cable knob and tube nother n/a
Special outlets F�] range 0 water heater 0 other 220 volt j i of it)Lio infoL-clothp-sS1LYer-----
�x Doorbell n Chimes 0 Push-button locations front door only —--__--`_----------_
Additional information none
25.1.ighting Fixtures
Total number of fixtures see dwgsl—_ Total allowance for fixtures, typical installation, $
Nontypical installation none
Additional information none
n/a
ref. HUD Handbook 4145.1 & 4950.1 form HUD-92005 (10/84)
Retain this record for three years Page 5 of 6 VA Form 26-1852 and form FmHA 424-2
26. Insulation
Location
Thickness
Material, Type, and Method of Installation
Vapor Barrier
Roof
n/a
n/a
n/a
Ceiling
10 inches
R-30 blown
n/a
Wall
3.5 inches
n/a
Floor
none
none
n/a _
Ext Walls
1 1/2 inch
R-2.6 4x8 Tuff-R celotex sheathing nailed and taped at all ioints _
foil taoe
27. Miscellaneous: (Describe any main dwelling materials, equipment, or construction items not shown elsewhere; or use to provide additional information
where the space provided was inadequate. Always reference by item number to correspond to numbering used on this form.)
'lowel bar, towel ring, and toilet paper holder to be installed in each bathroom
Hardware (make, material, and finish.)
Saturn or equal - basic architectural grade with bright brass finish
Special Equipment (State material or make, model and quantity. Include only equipment and appliances which are acceptable by local law, custom and
applicable FHA standards. Do not include items which, by established custom, are supplied by occupant and removed when he vacates premises or chattles
prohibited by law from becoming realty.)
none
Porches
7 feet deep
Terraces
none
Garages
none
Walks and Driveways
Driveway width __ base material
Front walk width 4 feet material concrete
Steps material _none
__ thickness ____ surfacing material _n/a
thickness n/a
thickness 4 inch Service walk width 4 feet material concrete thickness 4 inch
treads n/a risers n/a Cheek walls n/a
Other Onsite Improvements
(Specify all exterior onsite improvements not described elsewhere, including items such as unusual grading, drainage structures, retaining walls, fence,
railings, and accessory structures.)
6 foot high cedar backyard privacy fence
Landscaping, Planting, and Finish Grading
Topsoil 2 inch_ thick 0 front yard a
side yards
n rear yard to
_ 10 feet behind main building
Lawns (seeded, sodded, or sprigged) ❑x front yard _
sod
❑x side yards __ sod. -_ 0 rear yard __ sod
Planting Fx] as specified and shown on drawings Flas
follows:
n/a Shade trees deciduous n/a —caliper
n/a _Evergreen trees n/a _— to n/a _ B & B
_ n/a__ Low flowering trees deciduous
_ n/a
to n/a _
_n/a -Evergreen shrubs n/a _ to n/a B & B
n/a-- High -growing shrubs deciduous
_ n/a
_ to n/a _
_n/a _ Vines, 2-year n/a
_ n/a _ Medium -growing shrubs deciduous
__n/a
to _`n/a
Other see approved drawings
n/a__ Low -growing shrubs deciduous
n/a
to _n/a__
Identification —This exhibit shall be identified by the signature of the builder, or sponsor, and/or the proposed mortgagor if the latter is known at the time
of application.
Date (mm/dd/yyyy)____ _ Signature
Signature
ref. HUD Handbook 4145.1 & 4950.1 form HUD-92005 (10/84)
Retain this record for three years Page 6 of 6 VA Form 26-1852 and form FmHA 424-2
•
Permit Number
MECcheck Compliance Report Checked By/Date
1995 MEC
MECcheckSoftware Version 3.4 Release la
Data filename: CAProgram Files\Check\MECcheck\1624 Plan.cck
TITLE: 1624
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 10/31/03
DATE OF PLANS: 10/31/03
PROJECT INFORMATION:
1624 Garden Home
Edelweiss Gartens
College station, Texas
COMPANY INFORMATION:
B. A. Cathey, Inc.
Box 9517
College Station, Texas
COMPLIANCE: Passes
Maximum UA = 2239
Your Home = 2030
9.3% Better Than Code
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
Ceiling 1: Flat Ceiling or Scissor Truss
1624
30.0
0.0
57
Exterior Wall 1: Wood Frame, 16" o.c.
1682
13.0
0.0
117
Door 1: Solid
80
0.610 49
Window 1: Metal Frame:Double Pane with Low-E
180
0.640 115
Floor 1: Slab-On-Grade:Unheated, 0.0' insul.
1624
0.0
1692
Air Conditioner 1: Electric Central Air, 12 SEER
Furnace 1: Forced Hot Air, 78 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 1995 MEC
requirements in MECcheckV Sion 3.4 Release l7�j'
to comply with the mandatory requirements listed in the MEC check
Inspection Checklist. , . / i
Builder/Designer I v /�I 2i Date
MECcheck Inspection Checklist
1995 MEC
MECcheckSoftware Version 3.4 Release la
DATE: 10/31/03
TITLE: 1624
Bldg.
Dept.
Use
Ceilings:
[ ] I 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
I
Above -Grade Walls:
[ J I 1. Exterior Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
I
Doors:
[ ] I 1. Door 1: Solid, U-factor: 0.610
Comments:
I
Floors:
[ ] I 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
I
Heating and Cooling Equipment:
[ ] I 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
[ ] I 2. Furnace 1: Forced Hot Air, 78 AFUE or higher
Make and Model Number
I
Air Leakage:
[ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] I Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
I with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
I
Materials Identification:
[ ] I Materials and equipment must be identified so that compliance can be determined.
[ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating
I equipment must be provided.
[ ] I Insulation R-values, glazing U-factors, and cooling equipment efficiency must be clearly marked on
the building plans or specifications.
I
Duct Insulation:
[ ] I Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
I
Duct Construction:
. [ ] I All ducts must be sealed with mastic and fibrous backing tape. Pressure -sensitive tape may be used
for fibrous ducts. Duct tape is not permitted.
[ J I The HVAC system must provide a means for balancing air and water systems.
0
0
Temperature Controls:
Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Circulating Hot Water Systems:
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
HVAC piping conveying fluids above 120 'F or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Table l: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in
Inches by Pipe Sizes
Heated Water
Non -Circulating
Runouts
Circulating Mains and Runouts
Temperature ( F)
Up to 1"
Up to 1.25"
1.5" to 2.0" Over 2"
170-180
0.5
1.0
1.5 2.0
140-160
0.5
0.5
1.0 1.5
100-130
0.5
0.5
0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Piping System Types
Range F
2" Runouts
1" and Less
1.25"
to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
City
of Collegge S on
FTORKUEST "�"'` ``''
PAGE
1
krv"
REQ/JOB:
WF0471730 /^�!`001 PROJEC.7;-�, a«.»
REQUEST DATE:
ffl06�03
PRINT DATE:
0603
CREW:
PRINT TIME:
13:26:08
SCHEDULE
LOCATION:
210 KARTEN LN
STTART:DATES
11/06/03
77845
COMPLETION:
11/06/03
GEN. LOC:
COLLEGE STATION LOC ID:
197440
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
B A CATHEY ORIGIN:
CUSTOMER -WALK
IN
USER ID:
MALFORD AUTH: MALFORD WORK
TYPE:
ROUTINE
4" SEWER AND 3/4" WATER
4" SEWER
AND 3/4" WATER
Category
code CS -CUSTOMER SERVICES
CSCS
Task code:
SET UP NEW UTILITY ACCT
SET
Facility
ID .
Assigned Department: OT-CUSTOMER SERVICE
BUILDING PERMIT_
F_ CITY OF COLLEGE STATION
:� • 1101 TEXAS AVE * — _ ' #_
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . 03-00003300 Date 11/06/03
Property Address . . . . . 210 KARTEN LN
Property ID . . 244030-0203-0010
R ## . . . . . . . . . . . . R114606
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . EDELWEISS GARTENS PH 2
Property Use .. . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 107184
Owner Contractor
------------------------ ------------------------
EDELWEISS GARTEN VENTURE B A CATHEY LTD
311 CECILIA LOOP BLAKE CATHEY
COLLEGE STATION TX 778456310 P O BOX 9517
COLLEGE STATION TX 77842
(979) 255-7064
------ Structure Information SINGLE FAMILY -----
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE CONCRETE
NUMBER OF GARAGE BAYS 2.00
HEATED AREA 1624.00
INTERIOR WALL TYPE GYPSUM .
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
SERIAL ZONES 244.00
-----------------------------------------------------------------------------
Permit . . . BUILDING PERMIT
Additional desc . . MA
Permit Fee . . . . 484.00 Plan Check Fee .00
Issue Date . . . . 11/06/03 Valuation . . . . 107184
Expiration Date . . 5/05/04
Qty Unit Charge Per Extension
BASE FEE 460.00
8.00 3.0000 THOU BLDG, VAL 100001-500000 24.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
-----------------
BUILDING DEPT RESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number
03-00003300
Page 2
Date 11/06/03
Special Notes and Comments
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR (S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
---------------- ---- --- -------------------
BUILDING DEPT RESENTATIVE:
APPLICANT: / " '" —
BUILDING PERMIT
• CITY OF COLLEGE STATION •
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
3
Application Number
. . . . .
03-00003300
Date
11/06/03
----------------------------------------------------------------------------
Other Fees . . . .
. . .
WATER TAP 3/4"
CITY INSTL
400.00
Fee summary
Charged
----------
Paid
----------
Credited
--------------------
Due
-----------------
Permit Fee Total
484.00
484.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1234.00
1234.00
.00
.00
--------------------------- ---- -- -------------------
BUILDING DEPT REPRWENTATIVE:
APPLICANT: 16v(.4�7�-
TEMPORARY POLE PERMIT
• CITY OF COLLEGE STATION i
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
03-00003301 Date
11/06/03
Property Address . . . . . .
210 KARTEN LN
Property ID . . . . . . . . .
244030-0203-0010
Application description . . .
TEMP POLE
Subdivision Name . . . . . .
EDELWEISS GARTENS PH 2
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
------------------------
EDELWEISS GARTEN VENTURE
B A CATHEY LTD
311 CECILIA LOOP
BLAKE CATHEY
COLLEGE STATION TX 778456310
P O BOX 9517
COLLEGE STATION
TX 77842
(979) 255-7064
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . MA
Permit Fee . . . . 20.00
Issue Date . . . . 11/06/03
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary Charged
Paid Credited
------------------------------
Due
---------------------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
------------------
BUILDING D
APPLICANT:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGESTATION.TX.US
// Fd o�lU� Owy 2
DATE: l (0 �` _ ( S �^
APPLICATION # 03 � - �( i )
TEMP POLE #
ADDRESS/LOCATION:_Iq
LOT I BLOCK SUBDIVISION �I l�� IwJF_ f S C�4-.e7v
BUSINESS/OWNER NAME: �t4tr_- 1...+`� PHONE: Z5S--'7t,( 5F
CONTRACTOR/HOMEOWNER: �B)/'k (: CA-H6� � PHONE: ZS S-7oG f
CONTRACTOR ADDRESS:
ELECTRICIAN: k QwS �'1L CI12c PLUMBER: C l"A...10w�
HVAC: GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITKCTUAL OR DESIGN RENEW COMMITTEE APPROVAL:
TEXAS ACCESSIBIILII' STANDARD PROJECT REGISTRATION# EABPRJ
VALUATION: $ Z1 9 TOTAL AREA: Z 16q HEATED AREA:
Labor and Materials)
PUBLIC SEWER
SEPTICITREATMENT SYSTEMEj/
,//
SEWER TAP: `�
S
WATER TAP: 3
SIZE
OTHER TAP:
SIZE
Q EMP POLE
GARAGE TYPE: SINGLE Q
ATTACHED
SIGNATURE OF APPLICANT:
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE Er
DETACHED a
3
C� LjLr
TRIPLE a
CARPORT a
Official Use Only
16 1.5,�03
ents:
Sr NO
Plans Examiner Zoning Official YE
h2
�J
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling I (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
i
0
O
p
O
O
R=25' \ — [ t
/k37.66'
KARTEN LANE
CAT7�HEY LOT: BLOCK: SUBDIVISION: Fil>C-LF,.J'E!5
HOMES ADDRESS: SCALE: I" a 20'