Loading...
HomeMy WebLinkAboutRES2003-03298 113 HARTFORD DR BUILDING PERMIT�sw3aq?f Off- 39qlalremp Ag mg 0) OEM PREPARED 2/25/04, 7:47:29 INSPECTION TICKET PAGE 7 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/25/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 113 HARTFORD DR SUBDIV: EDELWEISS GARTENS PH 2 CONTRACTOR BENCHMARK HOMES PHONE (979) 690-7117 OWNER EDELWEISS GARTEN VENTURE PHONE PARCEL 244030-0205-0170 APPL NUMBER: 03-00003298 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 11/24/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 11/24/03 AP 11/24/2003 07:21 AM GCARRILLO V. SETBACKS PER STRINGS. SLAB GROUND @ RIGHT BACK. BO 01 12/12/03 DS BLDG, FRAMING TIME: 17:00 12/17/03 AP 12/11/2003 03:43 PM GCARRILLO B125 01 2//25/0/4 BI BLDG, FINAL TIME: 17:00 Wd7l 11 02/24/2004 03:34 PM SSTANLEY -=------------------------------------ COMMENTS AND NOTES -------------------------- 1 i t i I i City of College Station WORK QUEST PAGE 1 REQ/JOB: WF0472069 /,lll01 PROJECT: REQUEST DATE: 11/07/03 PRINT DATE: 11/07/03 CREW: PRINT TIME: 16:31:03 SCHEDULE LOCATION: 113 HARTFORD DR STTART:DATES 11/07/03 77845 COMPLETION: 11/07/03 GEN. LOC: COLLEGE STATION LOC ID: 197502 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: BENCHMARK HOMES ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE 3/4"WTR, 411SWR 3/4"WTR, 4"SWR Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE City of Colle e Station OROEQUEST PAGE 1 REQ/JOB: WF0474909 /�^001 PROJECTI ,W REQUEST DATE: 11/21/03 PRINT DATE: 11/21/0' CREW: PRINT TIME: 8:30:21 LOCATION: 113 HARTFORD DR SCHEDULE START:DATES ll/21/03 77845 COMPLETION: 11/21/03 GEN. LOC: COLLEGE STATION LOC ID: 197502 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: BENCHMARK HOMES ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE BUILDING -PERMIT AM �4 1101 TEXAS AVE ' 6 COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003298 Date 11/07/03 Property Address . . . . . . 113 HARTFORD DR Property ID 244030-0205-0170 R # . . . . . . R114653 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . EDELWEISS GARTENS PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 94116 Owner Contractor ------------------------ EDELWEISS GARTEN VENTURE ------------------------ BENCHMARK HOMES 311 CECILIA LOOP GLENN THOMAS COLLEGE STATION TX 778456310 1110 12TH MAN COURT COLLEGE STATION TX 77845 (979) 690-7117 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 1426.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . MR Permit Fee . . . . 440.00 Plan Check Fee .00 Issue Date . . . . 11/07/03 Valuation . . . . 94116 Expiration Date . . 5/06/04 Qty Unit Charge Per Extension BASE FEE 260.00 45.00 4.0000 THOU BLDG, VAL 50001-100000 180.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ------ BUILDING DEPT RE,,RAESEN'yATIq APPLICANT: -CAA BUILDING PERMIT CITY OF COLLEGE STATION . 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003298 Page 2 Date 11/07/03 Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED BUILDING DEPT%1EPRE APPLICANT: AM--------------------------- BUILDING PERMIT CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003298 Date 11/07/03 ---------------------------------------------------------------------------- Special Notes and Comments SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES if gas dryer than it needs to be on 18" base ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 440.00 440.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1190.00 1190.00 .00 .00 w i\ A i / ------------------- BUILDING DE APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . Property Address . . . . Property ID R. # . . . . . . . . . . . Tenant nbr, name . . . . Application description . Subdivision Name . . . . Property Use . . . . . . Property Zoning . . . . . Application valuation . . 03-00003297 Date 11/07/03 113 HARTFORD DR 244030-0205-0170 . R114653 TEMP POLE TEMP POLE EDELWEISS GARTENS PH 2 . RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ EDELWEISS GARTEN VENTURE ------------------------ BENCHMARK HOMES 311 CECILIA LOOP GLENN THOMAS COLLEGE STATION TX 778456310 1110 12TH MAN COURT COLLEGE STATION TX 77845 (979) 690-7117 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . MR Permit Fee . . . . 20.00 Issue Date . . . . 11/07/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - - - - - - - - - - - - - - - - - - - BUILDING DEPT REPRI T IVE: APPLICANT: { ~ - - - - - - - - - - - - - - - - - - - - - - - - - tO APPLICATION FOR BUILDING PERMIT oA _ 0 VOF COLLEGE STATION • APPUM M s 1 TEXXAS AVENUE COLLEGE STATION. TX 77840 TEW POLE R (979) 764-3570 (979) 764-3496 FAX ADDRESS/LOCATION: 1 % ? d LOT _ i "7 BOCK SUBDIVISION L'��cL) t55 - •�4,r /�T$ BUSINESS/OWNER NAME: '� p�,n s = :-PHONE: I-oqQ •-71 17 CONTRACTOR/HOMEOWNEF;L ` ` i w� PHONE: Z— 517 CONTRACTOR ADDRESS: Z- ., ' Alf— i ELECTRICIAN: PLUMBER: HVAC: GOOD CENTS tReslden6ai CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY �- DUPLEX (Landscape Plans Req) REMODEL/RENOVATION L SWIMMING POOL DESCRIPTION OF WORK: _ STRUCTURE USE: ti u y C — ,... HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ TOTAL AREA:-1,�Z HEATED AREA: (Cost of tab r and Materials) ER r"VBUC SEWER 1 11 NUMBER OF BEDROOMS: 3 ❑ S l` � �.Y - EPTIQ I REATMENT SYSTEM ED-sEWERTAP: t ri TAQ: SIZEWATER 3 t l ❑ OTHER TAP: SIZE SIZE QYPEMP POLE GARAGE TYPE: SINGLE ❑ ATTACHED SIGNATURE OF APPLICANT. - NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALLTYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE _ _ [g) TRIPLE Z D 0/lrclal Use Only - YE or NO O Plans In, Zoning Mchd 6A M14 • • Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating V� 1• ,1 C� F i U ( I' ■ I ( 5� 1 I It. 113 �ar�'�ed 4► 0 ti A �J Al flay/27'�L� V a- *4ak� T REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release la Data filename: C:\Program Files\Check\REScheck\REScheck docs\253BM.rck TITLE: Benchmark Homes Jobpq MS CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 11 /01 /03 DATE OF PLANS: November 3, 2003 PROJECT INFORMATION: Benchmark Homes #252 113 Hartford Drove College Station, TX 77845 COMPANY INFORMATION: Benchmark Homes 1110 12th Man Court College Station, Tx 77845 NOTES: Like Home at 122 Karten, 3752 Essen Loop COMPLIANCE: Passes Maximum UA = 602 Your Home UA = 450 25.2% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.34 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.34 Door l: Solid Door 2: Glass SHGC: 0.34 Floor 1: Slab-On-Grade:Unheated Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 13 SEER Furnace 1: Forced Hot Air, 80 AFUE Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1426 30.0 0.0 50 1503 13.0 3.4 90 180 0.650 117 21 0.350 7 19 0.650 12 167 0.0 174 REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.5 Release la DATE: 11 /01 /03 TITLE: Benchmark Homes Job 252 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above -Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-3.4 continuous insulation Comments: Windows: [ ) ( 1. Window l: Metal Frame:Double Pane with Low-E, U-factor: 0.650 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door 1: Solid, U-factor: 0.350 Comments: [ ] 2. Door 2: Glass, U-factor: 0.650 Comments: Floors: [ ] 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: [ ] 1. Air Conditioner 1: Electric Central Air, 13 SEER or higher Make and Model Number [ ] 2. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 'F must be insulated to the I levels in Table 2. COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release la (formerly MECchec4 and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer Date Y Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)