HomeMy WebLinkAboutRES2003-03296 115 HARTFORD DR BUILDING PERMITOSV34dyep • 0 PREPARED 4/19/04, 7:46:16 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/19/04 __.L --------------------------------------------------------------------------------------------- ADDRESS . : 115 HARTFORD DR SUBDIV: EDELWEISS GARTENS PH 2 CONTRACTOR BENCHMARK HOMES PHONE (979) 690-7117 OWNER EDELWEISS GARTEN VENTURE PHONE I CEL 244030-0205-0180 API.NUMBER: 03-00003296 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/02/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 12/02/03 AP 12/02/2003 08:29 AM SSTANLEY r,x 12/03/2003 06:53 AM MALFORD ,r.., strings on setbacks - slab ground back left corner B115 01 1/02/04 DS BLDG, FRAMING TIME: 17:00 1/02/04 AP 12/31/2003 12:00 PM SSTANLEY B125 01 BLDG,4/1/m�}oq Ae � 04/16/2004L 04:32E PM7 GCARRILLO ----------------------------------- CONTINUED ONTO NEXT PAGE ----------------------------------- I ti. City of College ' Stion WOR QUEST REQ/JOB: WF0472070 / 01 '"� PROJECT: CREW: LOCATION: 115 HARTFORD DR 77845 �s PAGE 1 '�; REQUEST DATE: 11 07 03 PRINT DATE: 11%07%03 PRINT TIME: 16:32:10 SCHEDULE DATES START: 11/07/03 COMPLETION: 11/07/03 GEN. LOC: COLLEGE STATION LOC ID: 197504 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: BENCHMARK HOMES ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE 3/4"WTR, 4"SWR 3/4"WTR, 4"SWR Category code Task code: Facility ID Assigned Department: CS -CUSTOMER SERVICES CSCS SET UP NEW UTILITY ACCT SET OT-CUSTOMER SERVICE Mandi Alford - Inspections From: Jane Sayers To: Alford, Mandi; Stanley, Susan Date: 1 /7/2004 10:07:30 AM Subject: Inspections Please post insulation inspections for the Good Cents Program for: Herman Couch 304 Onyx Permit #03-3543 and Benchmark 115 Hartford' Perms 03-3296 for Dec ember 31, 2003. Thanks - BUILDING PERMIT nT;Y OF COL MI"PfATION COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003296 Date 11/07/03 Property Address . . . . . . 115 HARTFORD DR Property ID . . 244030-0205-0180 R # . . . . . . . . . . . . . R114654 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . EDELWEISS GARTENS PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 99924 Owner Contractor ------------------------ EDELWEISS GARTEN VENTURE ------------------------ BENCHMARK HOMES 311 CECILIA LOOP GLENN THOMAS COLLEGE STATION TX 778456310 1110 12TH MAN COURT COLLEGE STATION TX 77845 (979) 690-7117 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 1517.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . MR Permit Fee . . . . 460.00 Plan Check Fee .00 Issue Date . . . . 11/07/03 Valuation . . . . 99924 Expiration Date . . 5/06/04 Qty Unit Charge Per Extension BASE FEE 260.00 50.00 4.0000 THOU BLDG, VAL 50001-100000 200.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ------------------- BUILDING DE APPLICANT: BUILDING PERMIT • CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Application Number . . . . . 03-00003296 Page 2 Date 11/07/03 Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED --------------------------- -- ----- - -- -------------------------- BUILDING DEPTPRE ENMVE: APPLICANT: BUILDING PERMIT • CITY OF COLLEGE STATION• 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003296 Date 11/07/03 ---------------------------------------------------------------------------- Special Notes and Comments SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged ---------- Paid Credited Due ------------------------------ ----------------- Permit Fee Total 460.00 460.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1210.00 1210.00 .00 .00 ---------BUILDI-----N-G--DEPT------ �--------RESENTAT----- ---�AA� -------------------------- ��: APPLICANT: APPLICATION` FOR„BU1W1NG PF IT` 0WO01 F COLLE GE STATION N TEXAS AVENUE COLLEGE STATION. TX 77840 / (979) 7644570 (979) 764.3496 FAX WWW.CLC0LLEGE-STAT10iLTxUS , ADDRESS/LOCAT N: Wv r LOT BLOCK SUBDIVISION BUSINESS/OWNER NAME:p,n.� CONTRACTORIHOMEOWNER: CONTRACTOR ADDRESS: ti ID L IMA, l ' LATE _ �v�v� APPLICJIT(ON • TEMP POLE R r PHONE: "D r r l �r� PHONE: « / q —5/ / ELECTRICIAN: PLUMBER: -,fA HVAC: 01V,0iS GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL DESCRIPTION OF WORK: STRUCTURE USE: C HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ —50TOTAL AREA Z07 4_ HEATED AREA (`c7 1 (Cost of Labor and Materials) UBUC SEWER —L -1 "'l NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM SEWER TAP: J ©-WATER TAP: OTHER TAP: ,TEMP POLE 7=: GE TYPE: `t SME 1. S¢E SIZE SINGLE ED ATTACHED LEI SIGNATURE OF APPLICANT: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE [a TRIPLE Otfaar Me Only 1 1, Plans miner Zoning OBI Z S C k 0 0 ants: LYES NO 0 # P Energ y Code Compliance Information % Glazing of exterior walls V/ . Insulation R value of exterior walls Insulation R value of ceiling I (flit areas) Insulation R value of ceiling 2 (vaulted arm/no attic) 32) Glazing SHGC — -13 Glazing U-Fact6r R value of ductwork A/C SEER rating i f I • 9-611-el— 0 _ tpt'h x i LLri L-o-r 18 �31k 5 Et��.►-w�.xsS�ar��:�s :115 Efn oR�3 ,✓ Sty Tod ,Z.5144k i t t 551 T L0T t`'j VIkS C SS t h) i -,00p Permit Number MECcheck Compliance Report Checked By/Date 1995 MEC MECcheckSoflware Version 3.4 Release la Data filename: C:\Program Files\Check\MECcheck\MecCheck Docs\156TDT.cck TITLE: BM 254 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 11 /01 /03 DATE OF PLANS: 11/03/03 PROJECT INFORMATION: LOT 18 BLOCK 5 EDELWEISS GARTENS Phase II 115 Hartford Drive COLLEGE STATION, TEXAS 77845 COMPANY INFORMATION: Benchmark Homes 1110 12th Man Court College Station, TX 77845 NOTES: 1517 S/Ft Plan COMPLIANCE: Passes Maximum UA = 744 Your Home = 554 25.5% Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 1347 30.0 0.0 47 Ceiling 2: Cathedral Ceiling (no attic) 170 30.0 0.0 6 Wall 1: Wood Frame, 16" o.c. 478 13.0 3.4 33 Wall 2: Wood Frame, 16" o.c. 401 13.0 3.4 28 Wall 3: Wood Frame, 16" o.c. 422 13.0 3.4 30 Wall 4: Wood Frame, 16" o.c. 522 13.0 3.4 17 Window 1: Metal Frame, Double Pane 204 0.650 133 Window 2: Metal Frame, Double Pane 28 0.670 19 Door 1: Solid 26 0.130 3 Door 2: Glass 18 0.420 8 Floor 1: Unheated Slab -On -Grade, 0.0' insul. 221 0.0 230 Air Conditioner 1: Electric Central Air, 13 SEER Furnace 1: Forced Hot Air, 80 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 1995 MEC requirements in MECcheckVersion 3.4 Release la and to comply with the mandatory requirements listed in the MEC check Inspection Checklist. Builder/Designer Date • MECcheck Inspection Checklist 1995 MEC MECcheckSoftware Version 3.4 Release la DATE: 11 /01 /03 TITLE: BM 254 Bldg. Dept. Use I Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2. Ceiling 2: Cathedral Ceiling (no attic), R-30.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-3.4 continuous insulation Comments: 2. Wall 2: Wood Frame, 16" o.c., R-13.0 cavity + R-3.4 continuous insulation Comments: 3. Wall 3: Wood Frame, 16" o.c., R-13.0 cavity + R-3.4 continuous insulation Comments: 4. Wall 4: Wood Frame, 16" o.c., R-13.0 cavity + R-3.4 continuous insulation Comments: Doors: 1. Door 1: Solid, U-factor: 0.130 Comments: Floors: [ ] 1. Floor 1: Unheated Slab -On -Grade, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Air Conditioner 1: Electric Central Air, 13 SEER or higher Make and Model Number 2. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. • i Duct Insulation: Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] All ducts must be sealed with mastic and fibrous backing tape. Pressure -sensitive tape may be used for fibrous ducts. Duct tape is not permitted. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 120 T or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table I: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)