Loading...
HomeMy WebLinkAboutRES2003-03282 3700 MEADOW VIEW DR BUILDING PERMITPREPARED 3/01/04, 12:07:34 INSPECTION TICKET PAGE 5 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/01/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 3700 MEADOW VIEW DR SUBDIV: WESTFIELD ADDITION PH 3 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER BCS DEVELOPMENT CO PHONE PARCEL 650700-0308-0020 APPL NUMBER: 03-00003282 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 11/20/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 11/20/03 AP 11/19/2003 11:07 AM SSTANLEY setbacks perstrings-slab ground @ left back B115 01 12/15/03 DS BLDG, FRAMING TIME: 17:00 12/15/03 AP 12/12/2003 10:16 AM GCARRILLO Sheetrock Fireplace Chase, Firestopping B130 01 12/17/03 DS BLDG, INSULATION TIME: 17:00 12/17/03 DP 12/16/2003 09:31 AM SSTANLEY DID NOT FIX NOTES ON PREVIOUS INSPECTIONS. NEEDS TO SEAL HOLES IN TOP PLATE GARAGE AREA. B130 02 12/19/03 CH BLDG, INSULATION TIME: 17:00 12/19/03 AP 12/19/2003 08:04 AM SSTANLEY B125 01 2/23/04 DP BLDG, FINAL TIME: 17:00 2/23/04 DP 02/20/2004 04:12 PM GCARRILLO Need Proper Hardware On Doors dead bolts B125 02 3/, Ol/04 B LDG, FINAL TIME: 17:00 {'-/,,��� � Aeo3/01/2004 10:22 AM SSTANLEY ------------ IH ----------------------- COMMENTS AND NOTES -------------------------------------- /Vomay,}+­_ City of College Station WORK REQUEST o PAGE 1 REQ/J-CB: WF0473634 / 001 PROJECT: REQUEST DPRINT ATE: 11/17/03 CREW: PRINT TIME: 12:48:20 SCHEDULE LOCATION: 3700 MEADOW VIEW DR STTART:DATES 11/17/03 77845 COMPLETION: 11/17/03 GEN. LOC: COLLEGE STATION LOC ID: 193394 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: stylecraft builders ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE temp pole passed temp pole passed Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE N P R, M I T 4 &.�.. . 1101 -"TEXAS AVE' COLLEGE STATION, TX 77840 PHONE: ---------------------------------------------------------------------------- (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003282 Date 11/11/03 Property Address . . . . . . 3700 MEADOW VIEW DR Property ID 650700-0308-0020 R # R***** Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD ADDITION PH 3 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 83616 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4112 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 1.00 HEATED AREA 1248.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 396.00 Plan Check Fee .00 Issue Date . . . . 11/11/03 Valuation . . . . 83616 Expiration Date . . 5/10/04 Qty Unit Charge Per Extension BASE FEE 260.00 34.00 4.0000 THOU BLDG, VAL 50001-100000 136.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT BUILDING DEPT REPRESENTATIVE: APPLICANT: l�s^�i BUILDING PERMIT CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00003282 Date 11/11/03 ---------------------------------------------------------------------------- Special Notes and Comments ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR (S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-314 (2000 IRC) OR SECTION 1003.3.3 (2000 IBC) AS APPROPRIATE WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 396.00 396.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: •BUILDING PERMIT CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 03-00003282 Date 11/11/03 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1146.00 1146.00 .00 .00 --- -------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: � 7 TEMPORARY POLE PERMIT CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . Property Address . . . . Property ID R# . . . . . . . . . . . Tenant nbr, name . . . . Application description . Subdivision Name . . . . Property Use . . . . . . Property Zoning . . . . . Application valuation . . 03-00003283 Date 11/11/03 3700 MEADOW VIEW DR 650700-0308-0020 R***** TEMP POLE TEMP POLE WESTFIELD ADDITION PH 3 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4112 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . SS Permit Fee . . . . 20.00 Issue Date . . . . 11/11/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: f�� City of Collegge S tion WORKQUEST • PAGE 1 REQ/JOB: WF0472544 / 001 PROJECT: REQUEST DATE: 11/11/03 PRINT DATE: 11/11/03 CREW: PRINT TIME: 10:42:03 SCHEDULE DATES LOCATION: 3700 MEADOW VIEW DR 03 77845 COMPLETION: 11/11/03 GEN. LOC: COLLEGE STATION LOC ID: 193394 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 3/4" WATER 4" SEWER 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE I� LJ Fa Ojice Use Only APPLICATION FOR BUILDING PERMIT DATE: CITY OF COLLEGE STATION APPLICATION # Im's 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 TEMP POLE # (979) 764-3570 (979) 764-3496 FAX f' WWW.CI.COLLEGE-STATION.TX.US ADDRESS/ OCATION: ~ "I(x) OW view V�UU LOT C�BLOCK SUBDIVISION tst -cirl PHASE 22ext. BUSINESS/OWNER NAME: STYLECRAFT BUILDERS. INC. PHONE: 690-1 2 20 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR ADDRESS: 4090 State Highway 6 South j� ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): N CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Single Family Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS VALUATION: S$ ACCESSIBILITY STANDARD (TAS) PRC)JECT REGISTRATION# EABPRJ N/A �. (D LO 00 � TOTAL AREA:155-7 HEATED AREA: I Z (Cost of Labor and Materials) �X PUBLIC SEWER NUMBER OF BEDROOMS: ❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: Z XX SEWER TAP: QX WATER TAP: ❑ OTHER TAP: �X TEMP POLE GARAGE TYPE 4" SIZE 3/4e SIZE SIZE SINGLE ATTACHED FX SIGNATURE OF APPLICANT: Ck 01,5 1 1�3 Plans Examiner INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/or Masonry FOUNDATION TYPE: Slab on Grade ROOF TYPE: Composition DOUBLE DETACHED Official Use Only TRIPLE ED CARPORT Q IA J —I it I I Zoning Official ants: YES or NO Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork i R6 A/C SEER rating 12 REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release la Data filename: S:\ACAD\REScheck\1248—Porch.cck TITLE: PLAN #1248 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 10/31 /03 DATE OF PLANS: 10-31-03 PROJECT INFORMATION: SPEC 3700 Meadow View College Station, Texas COMPANY INFORMATION: Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 COMPLIANCE:' Pass Maximum UA = 452 Your Home UA = 435 3.8% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Single Pane SHGC: 0.40 Door 1: Solid Door 2: Solid Door 3: Glass SHGC: 0.40 Floor 1: Heated Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 12 SEER Furnace 1: Forced Hot Air, 80 AFUE Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1248 30.0 0.0 44 1132 13.0 0.0 75 166 0.670 111 18 0.500 9 20 0.500 10 18 0.580 10 169 0.0 176 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release la (formerly MECchecl and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer ( jt— " Date (� O f� REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.5 Release la DATE: 10/31 /03 TITLE: PLAN #1248 Bldg. Dept. Use Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: 1. Window 1: Metal Frame, Single Pane, U-factor: 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 1: Solid, U-factor: 0.500 Comments: 2. Door 2: Solid, U-factor: 0.500 Comments: 3. Door 3: Glass, U-factor: 0.580 Comments: Floors: 1. Floor 1: Heated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number 2. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. I Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 1 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. Cooling ducts with exterior insulation must be covered with a vapor retarder. Air filters are required in the return air system. The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the I levels in Table 2. C� J Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to V Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts V and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: Assembly Type JMJ�ffln=o Description COMM,.. off■ ■ : �� �� © . Emil- 14 Window Area Total: 174.34 10/31 /03 10:58:51 1 /1 • Area Calculator: I ME Asse - mblyType:MMIMIMMMMM Description Opaque door solid masonite m� ��■�■����� Door Area Total: 55.56 10/31 /0310:58:52 1 /1 0 Area Calculator: Assembly Type Comments/Description m■�■�� ®■�■�� m■�■�� ®■�■�� Ceiling Area Total: 0.00 10/31 /03 10:58:53 1 /1 0 i Area Calculator: Assembly Type Comments/Description Exterior Wall Area Total: 1132.00 10/31 /03 10:58:53 1 /1 u Area Calculator: Assembly Type Comments/Description Floor Area Total: 0.00 10/31 /0310:58:54 1 /1 i