Loading...
HomeMy WebLinkAboutRES2003-03270 4305 VELENCIA CT BUILDING PERMITD's 4m -S&I 0 OS- S?.l I (AU*Ao City of CollegORSta�troE W Q.T ,._ _.�.�........- I PAGE 1 REQ/JOB: WF0471356 /_ 01 PROJECT: REQUEST DATE.:-, 11/05/03 PRINT DATE:`. 11/05/03 CREW: PRINT TIME--"— 12:28:27 SCHEDULE,DATES LOCATION: 4305 VELENCIA CT START=: 11/05/03 77845 COMPLETION: 11/05/03 GEN. LOC: COLLEGE STATION LOC ID: 196292 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: D P L CONSTRUCTION ORIGIN: CUSTOMER -WALK IN USER,ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE r 4" SEWER TAP AND 3/4" WATER TAP 4" SEWER TAP AND'3/4" WATER TAP Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE 77 ; : --...� 04/06/2006 15:26 FAX 9796901041 CASTLEGATE 1001/001 DPL Contractors 4490 Castlegate Drive College Station, TX 77845 Phone: (979) 690-7250 Fax: (979) 690-7250 April 6, 2006 Chris Haver Building Official 1101 Texas Avenue College Station, TX 77840 RE: Permit Extension Dear Mr. Haver, ,�? (c)."(O— This letter is to request an extension on permit # 033270 issued at 4305 Velencia Court. This house has not sold. However, I'd like to have the gas turned on at this time for various reasons. I thank you In advance for your consideration and if you have any questions please feel free to contact our office. Sincerely, X--,Ja&,� Wallace Phillips DPL Contractors tie Muk. A Aj Mandi Alford -Insulation request inspection result, 4305 Velencia From: Brian Henry To: Carrillo, Gina; Stanley, Susan Date: 2/12/2004 9:17:10 AM Subject: Insulation request inspection result, 4305 Velencia #03-3270 Print for File Inspected insulation, 4305 Velencia #03-3270, D.P.Construction, 2-12-04 Inspection result: Inspected OK for Good Cents Notes: Seal exterior wall base plate, upstairs & downstairs. Seal all "T & corner beams, upstairs & downstairs. Duct & damper missing from upstairs bath exhaust fan. CC: Alford, Mandi City r of College Station WORK REQUEST PAGE 1 REQ/JOB: WF0473972 / 001 PROJECT: REQUEST DATE: PRINT DATE: 11/18/03 CREW: PRINT TIME: 12:14:30 SCHEDULE LOCATION: 4305 VELENCIA CT STTART:DATES 11/18/03 77845 COMPLETION: 11/18/03 GEN. LOC: COLLEGE STATION LOC ID: 196292 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: DPL CONTRACTORS ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE _ BUILDING PERMIT �O-nLE=_ S TAT I ON , T01 TEXAS AVE COLLEGE STATION, TX 77840- PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003270 Date 11/05/03 Property Address . . . . . . 4305 VELENCIA CT Property ID 184200-0801-0170 R # . . . . . . R113903 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE SEC 8 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 220000 Owner Contractor ------------------------ ------------------------ GREENS PRAIRIE INVESTORS LTD D P L CONTRACTORS. 4490 CASTLEGATE DR WALLACE PHILLIPS COLLEGE STATION TX 778453388 4490 CASTLEGATE DRIVE COLLEGE STATION TX 77845 (979) 690-7250 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID N FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 3048.00 INTERIOR WALL TYPE SR NUMBER OF BATHROOMS 4.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 249.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . MA Permit Fee . . . . 820.00 Plan Check Fee .00 Issue Date . . . . 11/05/03 Valuation . . . . 220000 Expiration Date . . 5/04/04 Qty Unit Charge Per Extension BASE FEE 460.00 120.00 3.0000 THOU BLDG, VAL 100001-500000 360.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ----- -----SENT------ -i / ,- I U�' - -------SEES-- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT • CITY OF COLLEGE STATION , 1101 TEXAS AVE COLLEGE STATION, TX 77840- PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003270 Page 2 Date 11/05/03 Special Notes and Comments PROVIDE COMBUSTION AIR -FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-314 (2000 IRC) OR SECTION 1003.3.3 (2000 IBC) AS APPROPRIATE WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN ---------------- -- -----� ,---.--------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840- PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003270 Date 11/05/03 ---------------------------------------------------------------------------- Special Notes and Comments PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total Charged Paid 820.00 820.00 .00 .00 750.00 750.00 1570.00 1570.00 Credited Due .00 .00 .00 .00 .00 .00 .00 .00 --------------------- - -------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: �f TEMPORARY POLE PERMIT CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840- PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003271 Date 11/05/03 Property Address . . . . . . 4305 VELENCIA CT Property ID . . . . . . . . . 184200-0801-0170 Application description . . . TEMP POLE Subdivision Name . . . . . . CASTLEGATE SEC 8 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS LTD ------------------------ D P L CONTRACTORS 4490 CASTLEGATE DR WALLACE PHILLIPS COLLEGE STATION TX 778453388 4490 CASTLEGATE DRIVE COLLEGE STATION TX 77845 (979) 690-7250 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . MA Permit Fee . . . . 20.00 Issue Date . . . . 11/05/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 APPLICANT: Fw Office Use ONy 0 APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US DATE: '& 30 03 APPLICATION # 0 '3�`�(� L� TEMP POLE # w- 32- ADDRESS/LOCATION: i` '_o 1 LOT /7 BLOCK —� SUBDIVISION SEC/&r--J>—_ BUSINESS/OWNER NAME: ,411% PHONE: CONTRACTOR/HOMEOWNER: 4910111.07z. CQ.✓)/7i4G7y/lI PHONE: try' O-/.?J00 CONTRACTOR ADDRESS: YWO C,e_S' IeedA_M " ,ee ELECTRICIAN: Gdti PLUMBER: HVAC: e52 GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION OVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL Req) ^, DESCRIPTION OF WORK: STRUCTURE USE: '11c2eo.%e HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: lz. TEXAS ACCESSIBILITY STANDARD (TAS) OJECT REGISTRATION# EABPPR VALUATION: $ ziZI/i Oct? TOTAL AREA:, 3 �d (Cost of Lab r and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: SEWER TAP: INTERIOR WALL TYPE: SIZE WATER TAP: EXTERIOR WALL TYPE: ZE OTHER TAP: FOUNDATION TYPE: SIZE VTEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE DOUBLE TRIPLE ATTACHED DETACHED a C PORT dr SIGNATURE OF APPLICANT: Official Use Only �I o Plans Examiner Zoning Official J HEATED AREA: y Ll ments. YES r NO Energy Code Compliance Information S % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating 0 u Elul ���' COIDE &F CIFICATIOMS y .G GROSS WALL SQ. FT.: 2,137.0113 PERCENTAGE OF FENESTRATION FENESTRATION SQ. FT.: 371.210 TO WALL RATIO: 17.3% IN ACCORDANCE WITH CHAPTER 5 OF THE INTERNATIONAL ENERGY CONSERVATION CODE, AND BASED ON THE PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS FOR THE BRYAN/COLLEGE STATION AREA, THE FOLLOWING SPECIFICATIONS WILL APPLY: TABLE 502.2.4(4), MAX IB% RATIO MAXIMUM GLAZING U FACTOR: 0.65 MINIMUM EXTERIOR WALL R-VALUE: R-13 MINIMUM I CEILING R-VALUE: R-30 MINIMUM HVAC SEER VALUE: 10 SEER ENERGY CODE SPECS CALCULATED FOR: D.P.L. CONTRACTORS, LLC. SPEC 2 / PLAN 3122 DATED: 12/05/02 OR HOME APPLICATION PROJECT ADDRESS - C/3 Y,4L,4 ka DATE % 3a BUILDER 19. P, `.: PHONE # elzz-740, MAILING ADDRESS MOBILE #`',Z.�,�'.y/�i PAGER # WINDOW TYPE (Aluminu' ouble Panet Ting, Etc.) SOLAR SCREENS yes no SOLAR FILM OR TINTED yes --.----,,no TYPE OF SKYLIGHTS `� SIZE• 'TINTED, yes . no' .r -EXTERIOR DOOR TYPES front rear G other. EXTERIOR WALL INSULATION R-VALUE_, 'SHEATHING 4-/t••inc 'es -IS SHEATHING.'ON ENTIRE EXTERIOR includin 'over bracing)? "yes no 'CEILING INSULATION' (please'list values for rooms that are different)• R- ..3 a. CEILING HEIGHTS IN FEET LIVING AREA iz •DINING _/Z 'BATHS /O BEDROOMS # i 10 #2 10 #3' /Q #4 . OTHER TYPE OF WATER HEATING::gas ti heat pump_ AFUE or COP TYPEOFHEATING: gas 1heat pump AFU.E or. COP. AIR CONDITIONING SEER if SEER is' I2 or over, you are 4ell.pble for an Energy Back II Rebate, did/will you apply for one? yes_no r FIREPLACE .yesno IF YES, FRESH AIR INTAKE- yes no ATTIC VENTILATION ROOF'S OVERHANG DISTANCE inches Building plans must include structure orientation on the plot and the direction.it faces. There is a^Godd'Cents"New Construction- Rebate available to the first'home buyer of a,Good Cents home upon, certification. If a Good Cents home is built as a speculative home and is not sold within one year after its certification, the rebate,will be withdrawn., • • 1. (QfC1TY O.F C-OLLEGE STATION,