Loading...
HomeMy WebLinkAboutRES2003-03253 2053 RAVENSTONE LOOP BUILDING PERMIT93- 3a�V.C�xn,pJ is I W\ 10 Cityof College St � ��n WORK RJEST REQ/JOB: WF0470359-;�-001-- CREW: �` LOCATION: 2053 RAVENSTONE LOOP 03 10/30/03 11:42:02 DATES 3003 10/30/03 GEN. LOC: COLLEGE STATION LOC ID: 193356 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: T C CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE 4" SEWER AND 3/4" WATER PROJECT 77845 4" SEWER AND 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE PAGE RtQUEST DATE: PRINT DATE: PRINT TIME: SCHEDULE START: COMPLETION: PREPARED 7/28/04, 12:01:59 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/28/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 2053 RAVENSTONE LOOP SUBDIV: CASTLEGATE SEC 1 PH 2 CONTRACTOR T C CUSTOM HOMES PHONE (979) 774-1110 OWNER GREENS PRAIRIE INVESTORS LTD PHONE PARCEL 184200-2102-0200 APPL NUMBER: 03-00003253 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 11/14/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00 11/17/03 AP 11/13/2003 04:48 PM GCARRILLO afternoon SETBACKS STRINGS PULLED SLAB GROUND FRONT LEFT B115 01 12/16/03 TB BLDG, FRAMING TIME: 17:00 12/17/03 AP 12/16/2003 11:22 AM MALFORD B125 01 7/ 8/ 4 nnBI BLDG, FINAL TIME: 17:00 L 07/28/2004 12:01 PM MALFORD -------------------------------------- COMMENTS AND NOTES ----------------------- -/ w + BUILD ENG WRMIT �Y.-Oia� COL��'G�r �TA•TI4N,..:.� • 4 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003253 Date 10/30/03 Property Address . . . . . . 2053 RAVENSTONE LOOP Property ID . . . . . . . . . 184200-2102-0200 R ## R111197 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE SEC 1 PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 218400 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS ------------------------ LTD T C CUSTOM HOMES 4490 CASTLEGATE DR TODD CARNES COLLEGE STATION TX 778453388 230 SOUTHWEST PARKWY E COLLEGE STATION TX 77840 (979) 774-1110 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 2318.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 249.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc MA Permit Fee . . . . 817.00 Plan Check Fee .00 Issue Date . . . . 10/30/03 Valuation . . . . 218400 Expiration Date . . 4/28/04 Qty Unit Charge Per Extension BASE FEE 460.00 119.00 3.0000 THOU BLDG, VAL 100001-500000 357.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT -------------------------------------------- -- - -- ---------------------- BUILDING DEAT REPaE)$ENTATIVE : APPLICANT: BUILDING PERMIT • WITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003253 Page 2 Date 10/30/03 Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO -PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-314 (2000 IRC) OR SECTION 1003.3.3 (2000 IBC) AS APPROPRIATE WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES add smoke detector upstairs BUILDING DE REnP/R�E �NTATVIVE:d/,�APPLICANT• //A I ! k/J9 BUILDING PERMIT WITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003253 Date 10/30/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged ---------- Paid ---------- Credited -------------------- Due ----------------- Permit Fee Total 817.00 817.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1567.00 1567.00 .00 .00 -------------------- BUILDING DEP APPLICANT: REPRES�TATIVE �TEMPORARY POLE PERMIT • ITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . Property Address . . . . Property ID R# . . . . . . . . . . . Application description . Subdivision Name . . . . Property Use . . . . . . Property Zoning . . . . . Application valuation . . 03-00003264 . 2053 RAVENSTONE LOOP 184200-2102-0200 R111197 TEMP POLE . CASTLEGATE SEC 1 PH 2 . RESIDENTIAL . PLANNED DEVL HOUSING 0 Date 10/30/03 Owner Contractor ------------------------ ------------------------ GREENS PRAIRIE INVESTORS LTD T C CUSTOM HOMES 4490 CASTLEGATE DR TODD CARNES COLLEGE STATION TX 778453388 230 SOUTHWEST PARKWY E COLLEGE STATION TX 77840 (979) 774-1110 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc MA Permit Fee . . . . 20.00 Issue Date . . . . 10/30/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Permit Fee Total Other Fee Total Grand Total Charged Paid -------------------- 20.00 20.00 45.00 45.00 65.00 65.00 Credited Due -------------------- .00 .00 .00 .00 .00 .00 -------------------------------------------- ---- --- -------------------- BUILDING DEI� REPR NTATIVE: — APPLICANT! ` .. 1. For oA'ct U_ 0,* 'APPLICATION FOR BUILDING kRMIT _ 69Q�. CITY OF COLLEGE STATION., APPLICATION # �. 3a I lul,TEXAS AVENUE _ ' COLLEGE STATION, TX 77840' TEMP POLE, tt' (679)764-3570 (979).764-3496 FAX - "' WWW.CI.COL:LEGE-STATION TX US• -''' ADDRESS/LOCATION: LOT Z.O BLOCK / SU_ ,301 %ISIONI% .BUSINESS/OWNER NAME: lio dd CONTRACTOR/HOMEOWNE(: CONTRACTOR ADDRESS: 1-2, ELECTRICIAN: ' 20 HVAC: Mown t�l I f� y� ACCESSORY/STORA E ADDITION I l DEMOLITION (Asbestos Survey) n, `PP DUPLEX (LandsCap� �ans Req) 1 ESCRIPTION OF WOR : I PHONE: > PHONE: tp I -2,> j PLU huVU UtN 15 (Residential only): yC`> CLASS OF WORK LOCATION RE -ROOF (Total/Partial) MOVING SHELL ONLY �1,4EW SLAB ONLY REIVIODEL/RENOVATION SWIMMING POOL .It ,STRUCTURE USE: / HOMEOWNER ASSOCIATION/ARCHIITTE+CTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD OJECT REGISTRATION# EABPRJ VALUATION: $ TOTAL AREA: A HEATED AREA: (Cost of L.a and Materials) . KPUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATM.. PYSTEM. NUMBER "O BATHROOMS: Z j) I/ SEWER TAP: It'%INTERIOR WALL YPE: SIZE \� WATER TAP:3Td-// EXTERIOR WALL WALL TYPE..-,.., t OTHER TAP:. • FOUNDATION TYPE: SIZE TEMP POLE ROOF TYPE: Loma . GARAGE TYPE:' SINGLE Q DOUBLE TRIPLE a ATTACHED , DETACHED ED CARPORT a 1 SIGNATURE OF APPLICANT: 1 I Official Use Only rt iR _Cwmernts: YES r NO Plans, Examiner Zoning Official Energy`Code. Compliance.Information % Glazing of ekterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value -of ceiling 2 (vaulted areas/no attic) Glazing SHGC C Glazing U-Factor , (� R value of ductwork A/C SEER rating Z. • • REScheck Compliance Certificate 2000 IECC REScheckSoflware Version 3.5 Release lb Data filename: R:\RAI MECcheck\T.C\2064-2318.rck TITLE: Plan #2064-2318 CITY: College Station STATE: Texas ^ HDD:1788 �+.. CONSTRUCTION TYPE: Single Family DATE: 10/27/03 DATE OF PLANS: 10-27-03 COMPANY INFORMATION: T.C. Homes (979)693-7895 NOTES: This REScheck report was generated by R.A.I.: John Rhodes (979) 764-7150 COMPLIANCE_ Passes °. r Maximum UA = 1154 Your Home UA = 843 26.9% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Wall 1: Wood Frame, 16" o.c. Window l: Metal Frame:Double Pane with Low-E SHGC: 0.40 Door 1: Solid Door 2: Glass SHGC: 0.40 Floor 1: Slab-On-Grade:Unheated Insulation depth: 0.0' Floor 2: All -Wood Joist/Truss:Over Unconditioned Space Furnace 1: Forced Hot Air, 80 AFUE Air Conditioner 1: Electric Central Air, 12 SEER Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1961 30.0 0.0 69 137 19.0 0.0 7 3582 13.0 0.0 259 359 0.650 233 42 0.440 18 18 0.550 10 231 0.0 241 107 14.0 0.0 6 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, • • and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lb (formerly MECchec4 and to comply with the mandatory requirements listed in the RE5 checkInspection Ch lclist. Builder/Designer Date/ 7- Q3 Area Calculator: Assembly Type MMI 10/27/03 09:49:53 Floor Area Total: 107.00 1 /1 Area Calculator: Assembly Type Comments/Description Exterior Wall Area Total: 3582.00 10/27/03 09:49:52 1/1 Area Calculator: m ■�■■■■■�■■■ Ceiling Area Total: 2127.00 10/27/03 09:49:52 1!1 E 0 Area Calculator: Assembly Type ==IMIMMM=M Comments/ Description M�MIMMMM MA 'mom ��■�■������ 10/27/03 09:49:62 Door Area Total: 323.56 1/1 E • Area Calculator: Add to Library Window Name Assembly Type Quantity Width x Height Unit Area Total Area U-Factor SHGC Comments/ Description 1 8064 Fixed Metal Frame, Do 2 8'-0" 6'-4" 50.67 101.34 ft2 0.650 0.400 2 2850 Metal Frame, Do 1 2'-8" 5'-0" 13.33 13.33 ft2 0.650 0.400 3 4008 Metal Frame, Do 1 4'-0" 0'-8" 2.67 2.67 ft2 0.650 0.400 4 4050 Metal Frame, Do 1 4'-0" 5'-0" 20.00 20.00 ft2 0.6501 0.400 5 4060 Metal Frame, Do 2 4'-0" 6'-0" 24.00 48.00 ft2 0.650 0.400 6 3060 Metal Frame, Do 3 T-0" 6'-0" 18.00 54.00 ft2 0.650 0.400 7 4040 Metal Frame, Do 1 4'-0" 4'-0" 16.00 16.00 ft2 0.650 0.400 8 2030 Metal Frame, Do 1 2'-0" 3'.0" 6.00 6.00 ft2 0.650 0.400 9 2060 Metal Frame, Do 1 2'-0" 6'-0" 12.00 12.00 ft2 0.650 0.400 10 3050 Metal Frame, Do 2 T-0" 5'-0" 15.00 30.00 ft2 0.650 0.400 11 2050 Metal Frame, Do 4 2'-0" 5'-0" 10.00 40.00 ft2 0.650 0.400 12 5026 Arch Metal Frame, Do 1 D = 5'-0" 9.82 9.82 1 ft2 0.650 0.400 13 40 arch Metal Frame, Do 1 D = 4'-0" 6.28 6.28 ft2 0.650 0.400 14 15 16 17 18 19 20 21 22 23 24 Window Area Total: 359.44 10/27/03 09:49:51 1/1 0 0 LMandi Alford - Insulation request inspection result, 2053 Ravenstone #03 3253 _ s� Page 1 From: Brian Henry To: Carrillo, Gina; Stanley, Susan Date: 12/19/2003 9:06:10 AM Subject: Insulation request inspection result, 2053 Ravenstone, #03-3253 Print for File Inspected insulation, 2053 Ravenstone, #03-3253, TC Custom Homes 12-19-03 Inspection result: Inspected OK for Good Cents CC: Alford, Mandi Gina Carrillo Insulation request inspection result 2053 Ravenstone #03 3253 Page 1 From: Brian Henry To: Carrillo, Gina; Stanley, Susan Date: 12/19/2003 9:06:10 AM Subject: Insulation request inspection result, 2053 Ravenstone, #03-3253 Print for File Inspected insulation, 2053 Ravenstone, #03-3253, TC Custom Homes 12-19-03 Inspection result: Inspected OK for Good Cents CC: Alford, Mandi