Loading...
HomeMy WebLinkAboutRES2003-03246 5101 SYCAMORE HILLS DR BUILDING PERMIT03- 32U(o r: �www�A�yfw y;f�iu Mramw. a i r l i 9 0 9F 4 PREPARED 6/02/04, 7:43:26 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/02/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 5101 SYCAMORE HILLS DR SUBDIV: PEBBLE CREEK CONTRACTOR LAM BUILDERS INC PHONE (979) 778-7818 OWNER PEBBLE CREEK DEVELOPMENT CO PHONE PARCEL 497900-0033-0010 APPL NUMBER: 03-00003246 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 11/05/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00 11/05/03 AP 11/04/2003 02:41 PM GCARRILLO SLAB GROUND MIDDLE RT. SIDE. STRINGS ON SETBACKS, OK. B101 12/04/03 CH BLDG, FRAMING TIME: 17:00 12/04/03 AP 12/04/2003 04:41 PM MALFORD NEED TO DOUBLE JOISTS IN GARAGE WHERE HEADERED OFF B130 01 12/05/03 CH BLDG, INSULATION TIME: 17:00 12/05/03 AP 12/05/2003 10:33 AM GCARRILLO B125 01 6/02/04 131 BLDG, FINAL TIME: 17:00 06(0)(tt( 6%0 pe 06/01/2004 03:40 PM GCARRILLO -------------------------------------- COMMENTS AND NOTES -------------------------------- City of Collegge Station AORK QUEST • PAGE 1 REQ/JOB: WF0471587 / 01 PROJECT: REQUEST DATE: 11/06/03 PRINT DATE: 11/06/03 CREW: PRINT TIME: 10:09:45 SCHEDULE DATES LOCATION: 5101 SYCAMORE HILLS DR 03 77845 COMPLETION: 11/06/03 GEN. LOC: COLLEGE STATION LOC ID: 151780 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: LAM BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE TEMP POLE ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE City of Collegge Station RORK&QUEST • PAGE 1 REQ/JOB: WF0472768 / 001 PROJECT: REQUEST DATE: 11/12/PRINT 03 CREW: PRINT TIME: 7:11:18 SCHEDULE DATES LOCATION: 2053 RAVENSTONE LOOP 03 77845 COMPLETION: 11/12/03 GEN. LOC: COLLEGE STATION LOC ID: 193356 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: T C CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE CITY OF COLLEGE STATION WORK QUEST • PAGE 1 REQ/JOB: WF0509657 / 001 PROJECT: REQUEST DATE: 4/21/PRINT 04 CREW: PRINT TIME: 16:16:33 SCHEDULE DATES LOCATION: 5101 SYCAMORE HILLS DR 04 77845 COMPLETION: 4/21/04 GEN. LOC: COLLEGE STATION LOC ID: 151780 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: B A CATHEY ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE City of College St *�'on; WORK UEST 4; PAGE 1 REQ/JOB: WF0470312 /�•001 PROJECT: REQUEST DATE: PRINT DATE: 10/30/03 CREW: PRINT TIME: 10:00:34 SCHEDULE DATES LOCATION: 5101 SYCAMORE HILLS DR 03 77845 COMPLETION: 10/30/03 GEN. LOC: COLLEGE STATION LOC ID: 151780 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: LAM BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE 4" SEWER AND 3/4" WATER 4" SEWER AND 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE r I BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003246 Date 10/30/03 Property Address . . . . . . 5101 SYCAMORE HILLS DR Property ID . . . . . . . . . 497900-0033-0010 R # . • . . . • . • • R103428 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . PEBBLE CREEK Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 192000 Owner Contractor ------------------------ PEBBLE CREEK DEVELOPMENT ------------------------ CO LAM BUILDERS INC % DAVIS YOUNG LOUIS MORELLA 4500 PEBBLE CREEK PKWY P O BOX 5052 COLLEGE STATION TX 77845 BRYAN TX 77805 (979) 778-7818 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2405.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 252.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . MA Permit Fee . . . . 736.00 Plan Check Fee .00 Issue Date . . . . 10/30/03 Valuation . . . . 192000 Expiration Date . . 4/28/04 Qty Unit Charge Per Extension BASE FEE 460.00 92.00 3.0000 THOU BLDG, VAL 100001-500000 276.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) --------------- ---- --- -------------------- - BUILDING DEPT- - -- P ESENT7J/TIVE• �--� /� /__.-- A� APPLICANT: BUILDING PERMIT . CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003246 Page 2 Date 10/30/03 Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-314 (2000 IRC) OR SECTION 1003.3.3 (2000 IBC) AS APPROPRIATE WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003246 Date 10/30/03 ---------------------------------------------------------------------------- Special Notes and Comments GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Permit Fee Total 736.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1486.00 Paid Credited Due ------------------------------ 736.00 .00 .00 .00 .00 .00 750.00 .00 .00 1486.00 .00 .00 -------------------------------------------- BUILDING DEPT PXDRESENTAWVE : / APPLICANT: --------------------- - - - - - - TEMPORARY POLE PERMIT • CITY OF COLLEGE STATION i 1101 TEXAS AVE COLLEGE STATION, TX 77840- PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003247 Date 10/30/03 Property Address . . . . . . 5101 SYCAMORE HILLS DR Property ID . . 497900-0033-0010 R # . . . . . • • • • • . . . R103428 Application description . . . TEMP POLE Subdivision Name . . . . . . PEBBLE CREEK Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ PEBBLE CREEK DEVELOPMENT CO LAM BUILDERS INC DAVIS YOUNG LOUIS MORELLA 4500 PEBBLE CREEK PKWY P 0 BOX 5052 COLLEGE STATION TX 77845 BRYAN TX 77805 (979) 778-7818 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . MA Permit Fee . . . . 20.00 Issue Date . . . . 10/30/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Permit Fee Total Other Fee Total Grand Total ------------------- BUILDING DE APPLICANT: Charged Paid -------------------- 20.00 20.00 45.00 45.00 65.00 65.00 Credited Due -------------------- .00 .00 .00 .00 .00 .00 PT P ESENTA VE: G� "p k" � L-1 APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: s- 1 S rFa Ofte Use Only DATE: D 7_0 3 APPLICATION # 0 3 ., 1--4 TEMP POLE # 3 - 3g 1 / LOT BLOCK SUBDIVISION -e b h L, C SEC/PHA, BUSINESS/OWNER NAME: i—g(��-SID S- PHONE: -7 CONTRACTOR/HOMEOWNER: Si W1 4!�4- PHONE: u J I — S�3 d� Z CONTRACTOR ADDRESS: l �{�J2) Ott GA w/> by A! ��% ELECTRICIAN: PLUMBER: _/�✓5� HVAC: P_"! M CA-l� GOOD CENTS(Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION ADDITION 1-1 MOVING DEMOLITION (Asbestos Survey) CONSTRUCTION` DUPLEX (Landscape Plans REMODEL/RENOVATIO Req) I I z DESCRIPTION OF WORK: 4psr STRUCTURE USE: HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN R TEXAS ACCESSIBILITY STANDARD (TAS) P JECT REGIST RE -ROOF (Total/Partial) SHELL ONLY SLAB ONLY SWIMMING POOL 'IEW COMMITTEE APPROVAL: �S F� ,TION# EABPRJ 1 VALUATION: $����4�✓ TOTAL AREA:3G 14 HEATED AREA: O S� (CostofLabor d Materials) PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMEI' SEWER TAP: 'WATER TAP: OTHER TAP: Ep-TrMIP POLE GARAGE TYPE ,. 51ZE SINGLE ATTACHED SIGNATURE OF APPLICANT: NUMBER OF BATHROOMS: INTERIOR WALL TYPE q- d % EXTERIOR WALL TYPE: I� R ) CJC V10A.'" V/ N'o FOUNDATION TYPE: G' If " PA/�r SC 14 IS ROOF TYPE: �„ ✓m ✓1 nS r�'[ G•� DOUBLE TRIPLE IE ACHED a CARPORT Official Use Only C N �o�a81o3 Plans Examiner Zoning Official ments. or NO Energy Code Compliance Information % Glazin/ g of exterior walls � Insulation R value of exterior walls /3 Insulation R value of ceiling 1 (flat areas) ,3 V Insulation R value of ceiling 2 ( vaulted areas/no attic 2 2 ✓ ) Glazing SHGC Glazing U-Factor✓ R value of ductwork A/C SEER rating 1