HomeMy WebLinkAboutRES2003-03239 3707 MEADOW VIEW DR BUILDING PERMITW]
PREPARED 2/24/04, 7:35:25 INSPECTION TICKET PAGE 7
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/24/04
------------------------------------------------------------------------------------------------
ADDRESS . : 3707 MEADOW VIEW DR SUBDIV: WESTFIELD ADDITION PH 2
CONTRACTOR MAIN STREET HOMES PHONE (979)
OWNER MAIN STREET HOMES CS LTD PHONE
PARCEL 650700-0211-0040
APPL NUMBER: 03-00003239 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/08/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00
12/08/03 AP 12/08/2003 08:11 AM GCARRILLO
Bi 01 1/16/04 DS BLDG, FRAMING TIME: 17:00
1/16/04 AE O1/15/2004 02:39 PM SSTANLEY
Sheetrock Fireplace Chase, Firestopping
B130 01 1/20/04 DS BLDG, INSULATION TIME: 17:00
1/20/04 DP O1/20/2004 07:44 AM MALFORD
Did Not Fix Notes From Previous Inspections
B130 02 1/21/04 DP BLDG, INSULATION TIME: 17:00
1/21/04 AP O1/20/2004 03:57 PM SSTANLEY
B125 01 2/24/04 BI BLDG, FINAL TIME: 17:00
02/23/2004 03:43 PM GCARRILLO
----'---------------------------------- COMMENTS AND NOTES --------------------------------------
12/09/2003 10:12 FAX 9797752873 CARLOMAGNO SURVEYING
[a 002
' WESTFIELD PHASE
RECORDED IN V. 5080,
S 44 37'41- E „ 55.00'
Cr �/ �10' PUBLIC UTILITY
N O EASEMENT(PLAr)
25' BUILDING LINE(PLAT, ORD.)
tz
z Of I �
A
LOT 3 a i LOT 4 i s
n.
BLOCK 1 2 I BLOCK 1 Iz
z: I �
of to
Q LI Don
rl I�
I I17�
— J
b 25' BUILD NG
LINE(PLAT, ORD.)
mti by
ti6 `Y°
10' PUBLIC UTILITY T
CONCRETE PAD EASEMENT(P-AT)
N 44 37'41 " W 55.00'
MEADOW VIEW DRIVE
50' R.O. W.
RESTRICTIONS RECORDED
IN VOL. 5550, PAGE 205
PER PLAT
File name: BLOCK I—LoT04.OWG
Plot date: 11/11/2005
Form: 12/08/2003
42
Ty
A
u!
N
N
m
ZE
LOT 5
BLOCK 1
LEGEND
O P1?0PER7Y CORNER
20 0 20 40 60 Feet
I p 2m,"A i c�� ma Rwiv
The bearing basis of thi. survey is the NORTHEAST line of
No, FOUR(4) BLOCK No.: ONE 1
the previous survey as retarded in Volume 5550. Page 205,
LOT ,
of the Official Public Records of Brazos County, :aid bearing
ADDITION OR SUDOM51ON: WESTFIELD ADDITION, PHASE 213,
being S 44'37'41" E
VOL 5550, PAGE 205
Said lot is not under the 100 year flood plain, as identified
by the Federol Emergency Management Agency on
SURVEYED FOR: MAIN STREET HOMES
Community Panel No. 48041CO182 C. Dated; July 2. 1992
STREET ADDRESS: 3707 MEADOW VIEW DRIVE
.°°
CITY, COLLEGE STATION COUNTY: SWOS
.
I. DANTE CARLOMAGNO. A REGISTERED PROFESSIONAL SURVEYOR, No.
° Q oe
1562. DO H£REDY CERTIFY THAT 1'HE ABOVE SURF IS A TRUE AND
°
ACCURATE REPRESENTATION OF AN ACTUAL ON THE GROUND SURVEY
MADE UNDER MY SUPERVISION AN) THERE ARE NO ENCROACHMENTS
DAN ARLOMAGN ANTC
D°°C ° LO.....
OR OVERLAPS UNLESS OTHERWISE SHOWN. All corners arc represented by
0 and are°° ° fOo
5/8- iron rods found unless othemise
WALLACE
notes.
aFESCj'Q�yO4
DRAWN BY: A.
GF1f 00034752
(S,�+R��(�,1�(�1'C�
`urI;PLJiYi J +1rtr_ 9tio°°°
77801
JDeq D37ot
2714 nfeather Road, Bryon, Texas
PHONE: (979)775-2873 FAX: (979)775-4787
www.CorlomagnoSurveying.com
12/09/2003 10:11 FAX 9797752873 CARLONAGNO SURVEYING
• •
J—CARLOMAGNO SunctiinM, inc.
Dante C.:arlon"alm" o
President
Z 001
2714 Finfeather Bryan, TX 77801 Email - CS@CartomagnoSU veying.com
Phone (979) 775 -2973 www.CarlomagaoSurveying.com
Fax (979) 775-4787
Date:
December 9, 2003 Time: 1 9:1.0 AM
Number of pages: 2 (Including this page)
TO: City of College Station - 764-3496
FROM: Adam
NOTES: Main Street Homes form survey — 3707 Meadow View Drive
:} City
of Collegqe Station
WORIWQUEST
PAGE
1
REQ/JOB:
WF0466378 / 001 PROJECT:
REQUEST DATE:
10/09/PRINT 03
CREW:
PRINT TIME:
11:10:03
SCHEDULE
DATES
LOCATION:
3707 MEADOW VIEW DR
03
77845
COMPLETION:
10/09/03
GEN. LOC:
COLLEGE STATION LOC
ID: 198298
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION
PRIORITY:
NORMAL
REQUESTOR:
MAIN STREET HOMES
ORIGIN:
CUSTOMER -WALK
IN
USER ID:
GCARRILLO AUTH: GCARRILLO
WORK TYPE:
ROUTINE
TEMP POLE PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
City of College St J'on �
WORK UEST
REQ/JOB: WF0470063 / 001 PROJECT:
CREW:
PAGE 1
PRQINTST DATE: DATTE: 10/29/03
03
PRINT TIME: 13:29:02
SCHEDULE DATES
LOCATION: 3707 MEADOW VIEW DR 03
77845 COMPLETION: 10/29/03
GEN. LOC: COLLEGE STATION LOC ID: 198298
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: MAIN STREET HOMES ORIGIN: CUSTOMER -WALK IN
USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE
3/4" WATER AND 4" SEWER
3/4" WATER AND 4" SEWER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
rrm TEMPOAQ.RY POLE PERMIT ..
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00003051 Date 10/01/03
Property Address . . . . . . 3707 MEADOW VIEW DR
Property ID . . 650700-2201-0040
Application description . . . TEMP POLE
Subdivision Name . . . . . . WESTFIELD ADDITION PH 2B
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
MAIN STREET HOMES CS LTD MAIN STREET HOMES
% MSH-CS INC RICK JENKINS PETER L DAVIS
7447 BEE CAVES RD STE 150 7447 BEE CAVE ROAD #150
AUSTIN TX 787464130 AUSTIN TX 78746
(979)
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . SS
Permit Fee . . . . 20.00
Issue Date . . . . 10/01/03 Valuation . . . . 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00
Fee summary Charged
Permit Fee Total 20.00
Other Fee Total 45.00
Grand Total 65.00
Paid
20.00
45.00
65.00
Credited Due
--------------------
.00 .00
.00 .00
.00 .00
---------- I ------------------------------------------ - --------------------
BUILDING DEPT REP T TIVE:
APPLICANT: �� /
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00003239 Date 10/29/03
Property Address . . . . . . 3707 MEADOW VIEW DR
Property ID . . . . . . . . . 650700-2201-0040
R# . . . . . . . . . . . . . R*****
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . WESTFIELD ADDITION PH 2B
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 91278
Owner Contractor
-
------------------------
-----------------------
MAIN STREET HOMES CS LTD MAIN STREET HOMES
% MSH-CS INC RICK JENKINS PETER L DAVIS
7447 BEE CAVES RD STE 150 7447 BEE CAVE ROAD #150
AUSTIN TX 787464130 AUSTIN TX 78746
(979)
------ Structure Information SINGLE FAMILY -----
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE CONCRETE
NUMBER OF GARAGE BAYS 2.00
HEATED AREA 1383.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
SERIAL ZONES 248.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . MA
Permit Fee . . . . 428.00 Plan Check Fee .00
Issue Date . . . . 10/29/03 Valuation . . . . 91278
Expiration Date . . 4/27/04
Qty Unit Charge Per Extension
BASE FEE 260.00
42.00 4.0000 THOU BLDG, VAL 50001-100000 168.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS WITHIN 20 FEET O ECHANICAL EQUIPMENT
--------------------------------------- -- �- -- --------------------
BUILDING DEPT REPR NTATIVE:
APPLICANT:
BUILDING PERMIT .
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 03-00003239 Date 10/29/03
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
------------------------------------------ - -------------------------------
Other Fees . . . . . . . . . SEWE T ' C INSTALL 350.00
-------------------------- i�i�
BUILDING DEPT RF� N
APPLICANT:
BUILDING PERMIT .
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
3
Application Number
. . . . .
03-00003239
Date
10/29/03
----------------------------------------------------------------------------
Other Fees . . .
. . . .
WATER TAP 3/4"
CITY INSTL
400.00
Fee summary
Charged
Paid
----------
Credited
--------------------
Due
-----------------
Permit Fee Total
----------
428.00
428.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1178.00
1178.00
.00
.00
BUILDING DEPT F. E E:
APPLICANT:/ -�
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEG E-STATION.TX. US
ADDRESS/LOCAT,ION: E1�}
LOT �1_ BLOCK SUBDIVISION
BUSINESS/OWNER NAME:
Westfield
PHONE:
CONTRACTOR/HOMEOWNER: Main Street Homes PHONE: (512) 327-8620
CONTRACTOR ADDRESS: 7447 Bee Cave Rd., Austin, TX 78746
ELECTRICIAN: Hillco Electric PLUMBER: CP Plumbing
HVAC: Barkers HVAC GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL
DESCRIPTION OF WORK: Construct Single Family Residence
`STRUCTURE USE: .51t-3(iLC rAwi l c
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ �N- TOTAL AREA:JSt(o HEATED AREA: /383
(Cost of Cabor and Materials)
PUBLIC SEWER - l fj/ P_ -7(4!5 NUMBER OF BEDROOMS: 3
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: — ;z—
X I SEWER TAP: 4" INTERIOR WALL TYPE: Wood / Sheetrock
SIZE
X� WATER TAP: 3/4" EXTERIOR WALL TYPE: Wood/ Masonry
SIZE q
OTHER TAP: FOUNDATION TYPE: Post Tension on Grade
SIZE
TEMP POLE ROOF TYPE: Asphalt Shingles
GARAGE TYPE: SINGLE a DOUBLE ® TRIPLE a
ATTACHED ® DETACHED a CARPORT
SIGNATURE OF APPLICANT:
Official Use Only
Pxw
ents:
CN io .141o3 YES r NO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
OCT-24-2003 FRI 12:09 PM,, jN STREET HOMES FAX NO. *75138
P. 02
Energy Code Compliance Inj'ormatfon
% Glazing of exterior walls 9
Insulation R value of exterior wall 3 -IE✓
Insulation R value of ceiling I (fla ; areas) 301
Insulation R value of ceiling 2 (va ilted areas/no.aitic) 2_ /
Glazing SHGC •3(p /
Glazing U-Factor
R value of ductwork (p
A/C SEER rating 1 2—i