Loading...
HomeMy WebLinkAboutRES2003-03239 3707 MEADOW VIEW DR BUILDING PERMITW] PREPARED 2/24/04, 7:35:25 INSPECTION TICKET PAGE 7 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/24/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 3707 MEADOW VIEW DR SUBDIV: WESTFIELD ADDITION PH 2 CONTRACTOR MAIN STREET HOMES PHONE (979) OWNER MAIN STREET HOMES CS LTD PHONE PARCEL 650700-0211-0040 APPL NUMBER: 03-00003239 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 12/08/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 12/08/03 AP 12/08/2003 08:11 AM GCARRILLO Bi 01 1/16/04 DS BLDG, FRAMING TIME: 17:00 1/16/04 AE O1/15/2004 02:39 PM SSTANLEY Sheetrock Fireplace Chase, Firestopping B130 01 1/20/04 DS BLDG, INSULATION TIME: 17:00 1/20/04 DP O1/20/2004 07:44 AM MALFORD Did Not Fix Notes From Previous Inspections B130 02 1/21/04 DP BLDG, INSULATION TIME: 17:00 1/21/04 AP O1/20/2004 03:57 PM SSTANLEY B125 01 2/24/04 BI BLDG, FINAL TIME: 17:00 02/23/2004 03:43 PM GCARRILLO ----'---------------------------------- COMMENTS AND NOTES -------------------------------------- 12/09/2003 10:12 FAX 9797752873 CARLOMAGNO SURVEYING [a 002 ' WESTFIELD PHASE RECORDED IN V. 5080, S 44 37'41- E „ 55.00' Cr �/ �10' PUBLIC UTILITY N O EASEMENT(PLAr) 25' BUILDING LINE(PLAT, ORD.) tz z Of I � A LOT 3 a i LOT 4 i s n. BLOCK 1 2 I BLOCK 1 Iz z: I � of to Q LI Don rl I� I I17� — J b 25' BUILD NG LINE(PLAT, ORD.) mti by ti6 `Y° 10' PUBLIC UTILITY T CONCRETE PAD EASEMENT(P-AT) N 44 37'41 " W 55.00' MEADOW VIEW DRIVE 50' R.O. W. RESTRICTIONS RECORDED IN VOL. 5550, PAGE 205 PER PLAT File name: BLOCK I—LoT04.OWG Plot date: 11/11/2005 Form: 12/08/2003 42 Ty A u! N N m ZE LOT 5 BLOCK 1 LEGEND O P1?0PER7Y CORNER 20 0 20 40 60 Feet I p 2m,"A i c�� ma Rwiv The bearing basis of thi. survey is the NORTHEAST line of No, FOUR(4) BLOCK No.: ONE 1 the previous survey as retarded in Volume 5550. Page 205, LOT , of the Official Public Records of Brazos County, :aid bearing ADDITION OR SUDOM51ON: WESTFIELD ADDITION, PHASE 213, being S 44'37'41" E VOL 5550, PAGE 205 Said lot is not under the 100 year flood plain, as identified by the Federol Emergency Management Agency on SURVEYED FOR: MAIN STREET HOMES Community Panel No. 48041CO182 C. Dated; July 2. 1992 STREET ADDRESS: 3707 MEADOW VIEW DRIVE .°° CITY, COLLEGE STATION COUNTY: SWOS . I. DANTE CARLOMAGNO. A REGISTERED PROFESSIONAL SURVEYOR, No. ° Q oe 1562. DO H£REDY CERTIFY THAT 1'HE ABOVE SURF IS A TRUE AND ° ACCURATE REPRESENTATION OF AN ACTUAL ON THE GROUND SURVEY MADE UNDER MY SUPERVISION AN) THERE ARE NO ENCROACHMENTS DAN ARLOMAGN ANTC D°°C ° LO..... OR OVERLAPS UNLESS OTHERWISE SHOWN. All corners arc represented by 0 and are°° ° fOo 5/8- iron rods found unless othemise WALLACE notes. aFESCj'Q�yO4 DRAWN BY: A. GF1f 00034752 (S,�+R��(�,1�(�1'C� `urI;PLJiYi J +1rtr_ 9tio°°° 77801 JDeq D37ot 2714 nfeather Road, Bryon, Texas PHONE: (979)775-2873 FAX: (979)775-4787 www.CorlomagnoSurveying.com 12/09/2003 10:11 FAX 9797752873 CARLONAGNO SURVEYING • • J—CARLOMAGNO SunctiinM, inc. Dante C.:arlon"alm" o President Z 001 2714 Finfeather Bryan, TX 77801 Email - CS@CartomagnoSU veying.com Phone (979) 775 -2973 www.CarlomagaoSurveying.com Fax (979) 775-4787 Date: December 9, 2003 Time: 1 9:1.0 AM Number of pages: 2 (Including this page) TO: City of College Station - 764-3496 FROM: Adam NOTES: Main Street Homes form survey — 3707 Meadow View Drive :} City of Collegqe Station WORIWQUEST PAGE 1 REQ/JOB: WF0466378 / 001 PROJECT: REQUEST DATE: 10/09/PRINT 03 CREW: PRINT TIME: 11:10:03 SCHEDULE DATES LOCATION: 3707 MEADOW VIEW DR 03 77845 COMPLETION: 10/09/03 GEN. LOC: COLLEGE STATION LOC ID: 198298 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: MAIN STREET HOMES ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE City of College St J'on � WORK UEST REQ/JOB: WF0470063 / 001 PROJECT: CREW: PAGE 1 PRQINTST DATE: DATTE: 10/29/03 03 PRINT TIME: 13:29:02 SCHEDULE DATES LOCATION: 3707 MEADOW VIEW DR 03 77845 COMPLETION: 10/29/03 GEN. LOC: COLLEGE STATION LOC ID: 198298 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: MAIN STREET HOMES ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE 3/4" WATER AND 4" SEWER 3/4" WATER AND 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE rrm TEMPOAQ.RY POLE PERMIT .. COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003051 Date 10/01/03 Property Address . . . . . . 3707 MEADOW VIEW DR Property ID . . 650700-2201-0040 Application description . . . TEMP POLE Subdivision Name . . . . . . WESTFIELD ADDITION PH 2B Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ MAIN STREET HOMES CS LTD MAIN STREET HOMES % MSH-CS INC RICK JENKINS PETER L DAVIS 7447 BEE CAVES RD STE 150 7447 BEE CAVE ROAD #150 AUSTIN TX 787464130 AUSTIN TX 78746 (979) ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . SS Permit Fee . . . . 20.00 Issue Date . . . . 10/01/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged Permit Fee Total 20.00 Other Fee Total 45.00 Grand Total 65.00 Paid 20.00 45.00 65.00 Credited Due -------------------- .00 .00 .00 .00 .00 .00 ---------- I ------------------------------------------ - -------------------- BUILDING DEPT REP T TIVE: APPLICANT: �� / BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003239 Date 10/29/03 Property Address . . . . . . 3707 MEADOW VIEW DR Property ID . . . . . . . . . 650700-2201-0040 R# . . . . . . . . . . . . . R***** Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD ADDITION PH 2B Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 91278 Owner Contractor - ------------------------ ----------------------- MAIN STREET HOMES CS LTD MAIN STREET HOMES % MSH-CS INC RICK JENKINS PETER L DAVIS 7447 BEE CAVES RD STE 150 7447 BEE CAVE ROAD #150 AUSTIN TX 787464130 AUSTIN TX 78746 (979) ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 1383.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . MA Permit Fee . . . . 428.00 Plan Check Fee .00 Issue Date . . . . 10/29/03 Valuation . . . . 91278 Expiration Date . . 4/27/04 Qty Unit Charge Per Extension BASE FEE 260.00 42.00 4.0000 THOU BLDG, VAL 50001-100000 168.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET O ECHANICAL EQUIPMENT --------------------------------------- -- �- -- -------------------- BUILDING DEPT REPR NTATIVE: APPLICANT: BUILDING PERMIT . CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00003239 Date 10/29/03 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ------------------------------------------ - ------------------------------- Other Fees . . . . . . . . . SEWE T ' C INSTALL 350.00 -------------------------- i�i� BUILDING DEPT RF� N APPLICANT: BUILDING PERMIT . CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003239 Date 10/29/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid ---------- Credited -------------------- Due ----------------- Permit Fee Total ---------- 428.00 428.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1178.00 1178.00 .00 .00 BUILDING DEPT F. E E: APPLICANT:/ -� APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEG E-STATION.TX. US ADDRESS/LOCAT,ION: E1�} LOT �1_ BLOCK SUBDIVISION BUSINESS/OWNER NAME: Westfield PHONE: CONTRACTOR/HOMEOWNER: Main Street Homes PHONE: (512) 327-8620 CONTRACTOR ADDRESS: 7447 Bee Cave Rd., Austin, TX 78746 ELECTRICIAN: Hillco Electric PLUMBER: CP Plumbing HVAC: Barkers HVAC GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL DESCRIPTION OF WORK: Construct Single Family Residence `STRUCTURE USE: .51t-3(iLC rAwi l c HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ �N- TOTAL AREA:JSt(o HEATED AREA: /383 (Cost of Cabor and Materials) PUBLIC SEWER - l fj/ P_ -7(4!5 NUMBER OF BEDROOMS: 3 SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: — ;z— X I SEWER TAP: 4" INTERIOR WALL TYPE: Wood / Sheetrock SIZE X� WATER TAP: 3/4" EXTERIOR WALL TYPE: Wood/ Masonry SIZE q OTHER TAP: FOUNDATION TYPE: Post Tension on Grade SIZE TEMP POLE ROOF TYPE: Asphalt Shingles GARAGE TYPE: SINGLE a DOUBLE ® TRIPLE a ATTACHED ® DETACHED a CARPORT SIGNATURE OF APPLICANT: Official Use Only Pxw ents: CN io .141o3 YES r NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating OCT-24-2003 FRI 12:09 PM,, jN STREET HOMES FAX NO. *75138 P. 02 Energy Code Compliance Inj'ormatfon % Glazing of exterior walls 9 Insulation R value of exterior wall 3 -IE✓ Insulation R value of ceiling I (fla ; areas) 301 Insulation R value of ceiling 2 (va ilted areas/no.aitic) 2_ / Glazing SHGC •3(p / Glazing U-Factor R value of ductwork (p A/C SEER rating 1 2—i