HomeMy WebLinkAboutRES2003-03214 3701 SPRINGFIELD DR BUILDING PERMITQ3 -- 3a i
s
1 '.
0
PREPARED 3/05/04, 7:42:08 INSPECTION TICKET PAGE 3
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/05/04
------------------------------------------------------------------------------------------------
ADDRESS . : 3701 SPRINGFIELD DR SUBDIV: WESTFIELD ADDITION PH 2
CONTRACTOR MAIN STREET HOMES PHONE (979)
OWNER MAIN STREET HOMES CS LTD PHONE
PARCEL 650700-0201-0010
APPL NUMBER: 03-00003214 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
RE MIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 12/03/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00
12/03/03 AP 12/02/2003 03:42 PM SSTANLEY
12/03/2003 12:04 PM MALFORD
slab ground right side of home
B115 01 1/30/04 DS BLDG, FRAMING TIME: 17:00
1/30/04 DP O1/29/2004 01:53 PM MALFORD
Loose Or Missing Anchor Bolt Nuts
Sheetrock Fireplace Chase, Firestopping
B115 02 2/03/04 DS BLDG, FRAMING TIME: 17:00
2/03/04 AP 02/02/2004 09:43 AM GCARRILLO
afternoon
B130 01 2/04/04 DS BLDG, INSULATION TIME: 17:00
2/04/04 AP 02/03/2004 11:16 AM SSTANLEY
afternoon
B125:01' 3/05/04 BI BLDG, FINAL TIME: 17:00
t.
03/04/2004 03:54 PM GCARRILLO
COMMENTS AND NOTES ------------------- �--- 0'-
60
BUILLD4NG PERMIT
t CITY OF CFSLLEGE STATW.ION
.. +nly.....r-w�• .•A '�tiA.vJ�JM+s. WYr+ww-�i'. . .
110 -'TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00003214 Date 11/10/03
Property Address . . . . . . 3701 SPRINGFIELD DR
Property ID . . . . . . . . . 650700-0201-0010
R # R114097
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . WESTFIELD ADDITION PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . UNKNOWN
Application valuation . . . . 70000
Owner Contractor
------------------------ ------------------------
MAIN STREET HOMES CS LTD MAIN STREET HOMES
% MSH-CS INC RICK JENKINS PETER L DAVIS
7447 BEE CAVES RD STE 150 7447 BEE CAVE ROAD #150
AUSTIN TX 787464130 AUSTIN TX 78746
(979)
------ Structure Information SINGLE FAMILY -----
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1016.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
SERIAL ZONES 248.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . SS
Permit Fee . . . . 340.00 Plan Check Fee .00
Issue Date . . . . 11/10/03 Valuation . . . . 70000
Expiration Date . . 5/09/04
Qty Unit Charge Per Extension
BASE FEE 260.00
20.00 4.0000 THOU BLDG, VAL 50001-100000 80.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
--------------------------------------� ---------------------------
BUILDING DEPT ��� TATIVE:
APPLICANT
BUILDING PERMIT
• CITY OF COLLEGE STATION .
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number
03-00003214
Page 2
Date 11/10/03
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
BUILDING DEPT
APPLICANT:
-------- r � 9 - ---------------------------
BUILDING PERMIT
0 CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
Fee summary
-----------------
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
-------------------
BUILDING DE
APPLICANT:
. . . . 03-00003214
Charged Paid
340.00 340.00
.00 .00
750.00 750.00
1090.00 1090.00
Credited
.00
.00
.00
.00
Page 3
Date 11/10/03
Due
.00
.00
.00
.00
0 •
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE , 4l-
COLLEGE STATION, TX 77840 IY'
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEG E-STATION.TX.US
6t,,,,
)OADDRESS/LOCATION: D Pe
�LOT �_✓ BLOCK SUBDIVISION
ESS WNEF2 NAME: �LJ Main Street Homes
CONTRACTOR/HOMEOWNER:
BUSIN /O
Westfield
Fa Ofte Um Only
DATE:�&2
AP CATION#
EMP POLE #
PHONE:
PHONE: (512) 327-8620
1
CONTRACTOR ADDRESS: 7447 Bee Cave Rd., Austin, TX 78746
ELECTRICIAN: Hillco Electric PLUMBER: CP Plumbing
HVAC: Barkers HVAC '_,GOOD CENTS (Residential only):
CLASS OF WORK (f 5
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION.
.(Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL
DESCRIPTION OF WORK: Construct Single Family Residence
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (T%) PROJECT REGISTRATION# EABPRJ
VALUATION: $ �/ TOTAL AREA: (ybS HEATED AREA: 161(y
(Cost o Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
X❑ SEWER TAP: 4"
SIZE
X j WATER TAP: 3 / 4"
SIZE
OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE a
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE ® TRIPLE
ATTACHED 1 a 1 DETACHED I _1 CARPORT
SIGNATURE OF APPLICANT:
3
a
Wood / Sheetrock
Wood/ Masonry
Post Tension on Grade
Asphalt Shingles
a
0
Official Use Only
YES?) NO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls 1,5-
Insulation R value of ceiling 1 (flat areas)30
Insulation R value of ceiling 2 (vaulted areas/no attic)_
Glazing SHGC 34
Glazing U-Factor . (gq
R value of ductwork
A/C SEER rating 1
City of College Station
WORKWQUEST
REQ/JOB: WF0472182 / 001 PROJECT:
CREW:
LOCATION: 3701 SPRINGFIELD DR
77845
PAGE
1
111003
11/10/03
11:46:02
DATES
1003
11/10/03
GEN. LOC: COLLEGE STATION LOC ID: 196348
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: MAIN STREET HOMES ORIGIN: CUSTOMER -WALK IN
USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE
3/4" WATER 4" SEWER
3/4" WATER 4" SEWER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
REQUEST DATE:
PRINT DATE:
PRINT TIME:
SCHEDULE
START
COMPLETION