HomeMy WebLinkAboutRES2003-03184 5113 WHISTLING STRAITS DR BUILDING PERMITC1 FA L PREPARED 3/29/04, 7:39:33 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/29/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 5113 WHISTLING STRAITS DR SUBDIV: PEBBLE CREEK CONTRACTOR MARIOTT HOMES INC PHONE (979) 696-1787 OWNER PEBBLE CREEK DEVELOPMENT CO PHONE PARCEL 497900-0044-0040 APPL NUMBER: 03-00003184 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 11/04/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00 11/04/03 AP 11/03/2003 03:03 PM MALFORD slab ground back rt. corner. strings on setbacks,ok. B115 01 12/11/03 TB BLDG, FRAMING TIME: 17:00 12/12/03 AP 12/11/2003 11:52 AM GCARRILLO B130 01 12/15/03 TB BLDG, INSULATION TIME: 17:00 12/15/03 AP 12/15/2003 07:26 AM SSTANLEY B125 01 3 29 04 BI BLDG, FINAL TIME: 17:00 aq bo,q 03/25/2004 08:06 AM SSTANLEY -------------------------------------- COMMENTS AND NOTES -------------------------------------- A�ic_'. City of Collegge Station., F1ORK REQUEST PAGE 1 REQ/JOB: WF0471351----/ 001 PROJECT: •, REQUEST DATE: 11/05/03 PRINT DATE: 11/05/03 CREW: w.- M -° PRINT TIME: 12 : 18 : 3 9 SCHEDULE DATES ,, LOCATION: 5113 WHISTLING STRAITS DR START: Ti/ 03 77845 COMPLETION: 11%05,03 GEN. LOC: COLLEGE STATION LOC ID: 196580 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: MARIOTT HOMES,INC ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE N BUIILIMDING PERMIT COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003184 Date 10/20/03 Property Address . . . . . . 5113 WHISTLING STRAITS DR Property ID . . 497900-0044-0040 R # . . • . • . . . . . . . . R114244 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . ... . PEBBLE CREEK Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 215016 Owner Contractor ------------------------ ------------------------ PEBBLE CREEK DEVELOPMENT CO MARIOTT HOMES INC % DAVIS YOUNG LARRY MARIOTT 4500 PEBBLE CREEK PKWY 209 ROCK PRAIRIE RD COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 696-1787 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 3.00 HEATED AREA 3162.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 252.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 808.00 Plan Check Fee .00 Issue Date . . . . 10/20/03 Valuation . . . . 215016 Expiration Date . . 4/18/04 Qty Unit Charge Per Extension BASE FEE 460.00 116.00 3.0000 THOU BLDG, VAL 100001-500000 348.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ------------------- BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 0 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00003184 Date 10/20/03 ---------------------------------------------------------------------------- Special Notes and Comments ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 ----Fee -summary------ -Charged Paid Credited Due ------------------- --- ---—'-------------------- BUILDING DEPT REPREaENTAT APPLICANT: BUILDING PERMIT • CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Permit Fee Total 808.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1558.00 03-00003184 808.00 .00 .00 .00 750.00 .00 1558.00 .00 ------------------------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: Page 3 Date 10/20/03 .00 .00 .00 .00 TEMPORARY POLE PERMIT CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003185 Date 10/20/03 Property Address . . . . . . 5113 WHISTLING STRAITS DR Property ID . . . . . . . . . 497900-0044-0040 Application description . . . TEMP POLE Subdivision Name . . . . . . PEBBLE CREEK Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ PEBBLE CREEK DEVELOPMENT CO ------------------------ MARIOTT HOMES INC % DAVIS YOUNG LARRY MARIOTT 4500 PEBBLE CREEK PKWY 209 ROCK PRAIRIE RD COLLEGE STATION TX 77845 COLLEGE STATION TX 77845 (979) 696-1787 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc SS Permit Fee . . . . 20.00 Issue Date . . . . 10/20/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ----------------------------------------- ---- --- ---------------------- BUILDING DEPT REPRIpSENTAT�YE APPLICANT: City of Colle e Station �ORK&QUEST REQ/JOB: WF0468235 / 001 PROJECT: CREW: PAGE 1 • REQUEST DATE: 10/21/03 PRINT DATE: 10/21/03 PRINT TIME: 8:12:45 SCHEDULE DATES LOCATION: 5113 WHISTLING STRAITS DR 03 77845 COMPLETION: 10%21%03 GEN. LOC: COLLEGE STATION LOC ID: 196580 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: MARIOTT HOMES,INC ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 4" sewer 3/4" water 4" sewer 3/4" water Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE For Office Use Ony APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATI, ADDRESS/Lq,CATIO%_XI0 YVIJ LOT BLOCK SUBDIVISION BUSINESS/OWNER NAME: CONTRACTOR/HOMEOWNER: CONTRACTOR ELECTRICIAN: HVAC: e, CLASS OF WORK DATE: APPLICATION # D TEMP POLE # --big y31 SEC/PH�/ PHONE: PHONE: 3 ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION VING SHELL ONLY DEMOLITION (Asbestos Survey) V NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL Req) DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS ROJECT REGISTRATION# EABPRJ VALUATION: $ I Lj, �L h ✓ TOTAL AREA: U,9? j HEATED AREA: 3L I&2 (Cost of La r and Materials) // PUBLIC SEWER NUMBER OF BEDROOMS: 3 7 S ER TAP: SIZE All WATER TAP: 'SIZE HER TAP: Srze EMP POLE S TIC/TREATMENT SYSTEM NUMBER OF BATHROOMS l� S WER TAP: INTERIOR WALL TYPE: SIZE ATER AP: EXTERIOR WALL TYPE: HER TAP: FOUNDATION TYPE SIZE TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE a-'DETAICHED UBLE ATTACHED SIGNATURE OF APPLICANT: TRIPLE a CAR��ORT a Official Use Only Ca Iolao 63 Plans Examiner Zoning Official ents. YES r NO 11 Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating a -4 m z Effi-ol c U3 o oR� Cl3 -u-Jp DrD�Z OmmUl t- Nm-,m p U) 03 fzD m �O z x MH-03-246 �,m �• UP20 SQ FT 4,330.6 SQ FT W-61A Front/ s4a-C�s SITE MARIOTT HOMES, INC. PLAN ©��l�0 xa�mmv,U,woiaamaAL