Loading...
HomeMy WebLinkAboutRES2003-03166 1031 WINDMEADOWS DR BUILDING PERMIT7emP 1 • hi�.9�NJR{ aQc+a Any, xYe. d5-31ZO40 .: ��yp 03-3/(a6' • N s 0 REQ/JOB CREW: City of Collegqe St tion W0R E JIT9 ' WF0468068 /'801 PROJECT: LOCATION: 1031 WINDMEADOWS DR 77845 GEN. LOC: COLLEGE STATION LOC ID: PAGE 1 03 PRINT DATE: T DATE: 10/20/ INT03 PRINT TIME: 15:41:19 SCHEDULE DATES START: 10/20/03 COMPLETION: 10/20/03 195760 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE SEWER 4" WATER 3/4" SEWER 4" WATER 3/4" Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE PREPARED 4/27/04, 12:02:38 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/27/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 1031 WINDMEADOWS DR SUBDIV: WESTFIELD VILLAGE PH 1 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER BCS DEVELOPMENT CO PHONE PARCEL 650730-0101-0100 APPL NUMBER: 03-00003166 RESIDENTIAL, 1 UNIT DETACHED NEW - ----------------------------------------------------------------------------------------------- PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 11/05/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 11/06/03 AP 11/05/2003 08:01 AM SSTANLEY SETBACK PER STRINGS - SLAB GROUND @ RIGHT BACK B115 01 12/11/03 DS BLDG, FRAMING TIME: 17:00 12/11/03 AP 12/10/2003 03:21 PM MALFORD 01 12/15/03 OC BLDG, INSULATION TIME: 17:00 tt 12/15/03 AP 12/15/2003 08:13 AM SSTANLEY F 01 4/27/0 B BLDG, FINAL TIME: 17:00 92 04/27/2004 10:07 AM GCARRILLO Oq ' s P-------------------------- ------ COMMENTS AND NOTES -------------------------------------- f City of Colle e Station ORK REQUEST PAGE 1 REQ/JOB: WF0468707 / 001 PROJECT: REQUEST DATE: ­�10/22/03 PRINT DATE: 10/22/03 CREW: PRINT TIME: 11:22:01 SCHEDULE DATES LOCATION: 1031 WINDMEADOWS DR 03 77845 COMPLETION: 10/22/03 GEN. LOC: COLLEGE STATION LOC ID: 195760 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE Y _.,,_BUILDING PERMIT V 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003166 Date 10/20/03 Property Address . . . . . . 1031 WINDMEADOWS DR Property ID . . . . . . . . . 650730-0101-0100 R # . . . . . . . . . . . . . R113291 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 80388 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1218.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GC Permit Fee . . . . 384.00 Plan Check Fee .00 Issue Date . . . . 10/20/03 Valuation . . . . 80388 Expiration Date . . 4/18/04 Qty Unit Charge Per Extension BASE FEE 260.00 31.00 4.0000 THOU BLDG, VAL 50001-100000 124.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) BUILDING DEPT REPRESENTATIVE: - ---------------------------- ---C'-'h APPLICANT: L` BUILDING PERMIT CITY OF COLLEGE STATION10 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003166 Page 2 Date 10/20/03 Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited Due ------------- ---------- ----------- ---- - --------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT • CITY OF COLLEGE STATIOI0 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Permit Fee Total 384.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1134.00 03-00003166 384.00 .00 750.00 1134.00 .00 .00 .00 .00 Page 3 Date 10/20/03 .00 .00 .00 .00 ---------------------- ---� - --------------------------- BUILDING DEPT REPRESENTATIVE APPLICANT: APPLICANT: ( L,/"�-- TEMPORARY POLE PERMIT • CITY OF COLLEGE STATIOI* 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003165 Date 10/20/03 Property Address . . . . . . 1081 WINDMEADOWS DR Property ID . . 650730-0101-0330 R ## . . . . . . . . . . . . . R113 314 Application description . . . TEMP POLE Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GC Permit Fee . . . . 20.00 Issue Date . . . . 10/20/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ---------------------- - ---------------------------- --- BUILDING DEPT REPRESENTATIVE. r-111 APPLICANT: � /�/�' I Fa Office Use Only APPLICATION FOR BUILDING PERMIT DATE: ly -YS—Ul CITY OF COLLEGE STATION APPLICATION # a 3 3) W 1101 TEXAS AVENUE ,� COLLEGE STATION, TX 77840 (�(�w' — TEMP POLE # 03 -554, to E3 (979) 764-3570 (979) 764-3496 FAX �] WWW.CI.COLLEGE-STATION.TX.US [ D - OD ADDRESS/LOCATION: 10 -3 � W''I � mr1 coo w S DO BLOCK SUBDIVISION "V I "r 1J I / P PHASE DQUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 �1 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbin HVAC: Control Temp GOOD CENTS (Residential only): N CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Single Family Residence HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: Y TEXAS ACCESSIBILITY STANDARD (TAS) PRSYJECT REGISTRATION# EABPRJ N/A VALUATION: $ S• / TOTAL AREA: HEATED AREA: (Cost of tabor and Materials) XX PUBLIC SEWER NUMBER OF BEDROOMS: ❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: �X SEWER TAP: 4" INTERIOR WALL TYPE: Sheet Rock SIZE �X WATER TAP: 3/a" EXTERIOR WALL TYPE: Siding and/or Masonry SIZE OTHER TAP: FOUNDATION TYPE: Slab on Grade SIZE 0 TEMP POLE ROOF TYPE: Composition GARAGE TYPE: SINGLE F__] DOUBLE F_� TRIPLE ATTACHED X� DETACHED F-1 CARPORT SIGNATURE OF APPLICANT: 67 `�---- For Stylecraft t1 Official Use Only ents ES 0�. Plans Examiner Zoning Official 0 • f Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating 1 Rio R13 R30 R19 .40 .65 R6 12 0 0 REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release la Data filename: S:\ACAD\REScheck\1218-1031 Windmeadows.cck TITLE: PLAN #1218 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 10/09/03 DATE OF PLANS: 10-10-03 PROJECT INFORMATION: Spec 1031 Windmeadows College Station, Texas COMPANY INFORMATION: Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 COMPLIANCE:= Passes Maximum UA = 354 Your Home UA = 280 20.9% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling 1: Flat Ceiling or Scissor Truss Wall 2: Wood Frame, 16" o.c. Window 4: Metal Frame, Double Pane with Low-E SHGC: 0.40 Door 3: Glass SHGC: 0.40 Door 5: Solid Floor 1: Unheated Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 12 SEER Furnace 1: Forced Hot Air, 80 AFUE Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1161 30.0 0.0 41 1240 13.0 0.0 87 131 0.650 85 20 0.500 10 33 0.900 30 26 0.0 27 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC • • requirements in REScheckVersion 3.5 Release la (formerly MECchecl and to comply with the mandatory requirements listed in the REScheckInspection Checklist. Builder/Designer % /' Date Gv is it 3 REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.5 Release la DATE: 10/09/03 TITLE: PLAN # 1218 Bldg. Dept. Use I Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above -Grade Walls: [ ] 1. Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation I Comments: Windows: 1. Window 4: Metal Frame, Double Pane with Low-E, U-factor: 0.650 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 3: Glass, U-factor: 0.500 Comments: 2. Door 5: Solid, U-factor: 0.900 Comments: Floors: 1. Floor 1: Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number 2. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. Cooling ducts with exterior insulation must be covered with a vapor retarder. Air filters are required in the return air system. The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 T must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: Description ©� :., - off■ . , ■ „ „ © , . , � Window Area Total: 131.00 10/09/03 15:44:16 1 /1 Area Calculator: Assembly Type Comments/ Description Door Area Total: 53.33 10/09/03 15:44:16 ill U Area Calculator: Assembly Type_ MComments/Description Ceiling Area Total: 1161.00 10/09/03 15:44:17 1 /1 is Area Calculator: Assembly Type— Comments/Description Exterior Wall Area Total: 1240.00 10/09/0315:44:17 1 /1 0 Area Calculator: Assembly Type- Comments/Description Floor Area Total: 0.00 10/09/03 15:44:18 1 /1 is �i