Loading...
HomeMy WebLinkAboutRES2003-03164 1081 WINDMEADOWS DR BUILDING PERMITTemp '0:!5-06" II WSW t a D3.3i�g �Giri 3 -3 0 City of Collegge St tion WORQUEST PAGE 1 REQ/JO B: WF0468067 (i01 �PROJECT:Y / -" 'REQUEST DATE: �PRQINT 10 20 03 DATE: 10/20/03 CREW: PRINT TIME: 15:39:50 SCHEDULE DATES LOCATION: 1081 WINDMEADOWS DR 03 77845 COMPLETION: 10/20/03 GEN. LOC: COLLEGE STATION LOC ID: 195806 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE SEWER 4" WATER 3/4" SEWER 4" WATER 3/4" Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE PREPARED 2/13/04, 12:00:43 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/13/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 1081 WINDMEADOWS DR SUBDIV: WESTFIELD VILLAGE PH 1 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER BCS DEVELOPMENT CO PHONE PARCEL 650730-0101-0330 APPL NUMBER: 03-00003164 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 10/31/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 10/31/03 AP 10/30/2003 02:43 PM MALFORD slab ground back right side B115 01 12/11/03 DS BLDG, FRAMING TIME: 17:00 12/11/03 AP 12/10/2003 03:21 PM MALFORD B130.01 12/15/03 OC BLDG, INSULATION TIME: 17:00 12/15/03 AP 12/15/2003 08:13 AM SSTANLEY B125 01 2/13/ 4 4,Ip BLDG, FINAL TIME: 17:00 dt� r d C- 02/13/2004 10:58 AM GCARRILLO -------------------------------------- COMMENTS AND NOTES-------------------------------------- City of Colle e Station ORK REQUEST PAGE 1 REQ/JOB: WF0469194 / 001 PROJECT: REQUEST DATE: 0/24/03 PRINT DATE: + Kj 24/03 CREW: PRINT TIME: 12:06:32 SCHEDULE DATES LOCATION: 1081 WINDMEADOWS DR START: 10/24/03 77845 COMPLETION: 10/24/03 GEN. LOC: COLLEGE STATION LOC ID: 195806 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE TEMP POLE ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE r BUILDING PERMIT �• CITY OF COLLEGE STATION COLLEGE STATION, TX 77840 PHONE: (979')'764.-3570 FAX: (979) 764-3496 --------------------------------------------- ---------------------------- Application Number . . . . . 03-00003164 Date 10/20/03 Property Address . . . . . . 1081 WINDMEADOWS DR Property ID 650730-0101-0330 R # R113314 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 75834 Owner Contractor ------------------------ ------------- ---------- BCS DEVELOPMENT CO STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1149.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc GC Permit Fee . . . . 364.00 Plan Check Fee .00 Issue Date . . . . 10/20/03 Valuation . . . . 75834 Expiration Date . . 4/18/04 Qty Unit Charge Per Extension BASE FEE 260.00 26.00 4.0000 THOU BLDG, VAL 50001-100000 104.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) --------------------------------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: ���� BUILDING PERMIT CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Application Number 03-00003164 Page 2 Date 10/20/03 Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES watch brace spans with number 3 lumber for rafters --------------- -_--------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 -------- ---- -------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00003164 Date 10/20/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged ---------- Paid ---------- Credited -------------------- Due ----------------- Permit Fee Total 364.00 364.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1114.00 1114.00 .00 .00 ----------------------- - - '1 - --------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003165 Date 10/20/03 Property Address . . . . . . 1081 WINDMEADOWS DR Property ID . . 650730-0101-0330 R # . . . . . . . . . . . . . R113314 Application description . . . TEMP POLE Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . GC Permit Fee . . . . 20.00 Issue Date . . . . 10/20/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - • APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE a4i Z& 96 j�. (� COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX Fa Ofte Use Only DATE: t o _/ s O 3 APPLICATION # 03 — 3 1 (04 TEMP POLE # L9J- 3 ) b Sv WWW.CI.COLLEGE-STATION.TX.US G� DDRESS/LOCATION: �� v• old M c �±d�n. S IiII I ' O LOT 3-3BLOCK 1 SUBDIVISION VV e r1 � V a �� In C: PHASE BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass P.lumbin HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Single Familv Residence HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: t TEXAS ACCESSIBILITY HEATED AREA: �� STANDARD V4Iz(TAS) PRO TOTAL AREA: � �JII'V ECN#RJ VALUATION: $ .00 Liq (Cost of Labor and Materials) D PUBLIC SEWER NUMBER OF BEDROOMS: 1� SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: d XX SEWER TAP: 4" INTERIOR WALL TYPE: Sheet Rock SIZE WATER TAP: 3/a" EXTERIOR WALL TYPE: Siding and/Or Masonry SIZE OTHER TAP: FOUNDATION TYPE: Slab On Grade SIZE ❑X TEMP POLE ROOF TYPE: Composition GARAGE TYPE: SINGLE F__] DOUBLE F_X(j TRIPLE ATTACHED [X DETACHED F-1 CARPORT SIGNATURE OF APPLICANT: �/`'`'L For Stylecraft ��11i'11 1.t1 1b��t��o3 Official Use Only YES r NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls 11 % Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork A/C SEER rating R6 12 REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release la Data filename: S:\ACAD\REScheck\l153-1149 1081 Windmeadows.cck TITLE: Plan # 1153-1149 Front Porch CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 10/09/03 DATE OF PLANS: 10/10/03 PROJECT INFORMATION: SPEC 1081 Windmeadows College Station, Texas COMPANY INFORMATION: Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 COMPLIANCE: Passes, Maximum UA = 521 Your Home UA = 440 15.5% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E SHGC: 0.40 Door 1: Solid Door 2: Glass SHGC: 0.40 Floor 1: Slab-On-Grade:Unheated Insulation depth: 0.0' Air Conditioner 2: Electric Central Air, 12 SEER Furnace 2: Forced Hot Air, 80 AFUE Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 845 30.0 0.0 30 294 19.0 0.0 15 1186 13.0 0.0 81 132 0.650 86 38 0.500 19 33 0.580 19 182 0.0 190 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, • and other calculations submitted with the permit application. • The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release la (formerly MECchec� and to comply with the mandatory requirements listed in the REScheckInspection Checklist. Builder/Designer �_ Date } • REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.5 Release la DATE: 10/09/03 TITLE: Plan # 1153-1149 Front Porch Bldg. Dept. Use I Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.650 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 1: Solid, U-factor: 0.500 Comments: 2. Door 2: Glass, U-factor: 0.580 1 Comments: Floors: 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Air Conditioner 2: Electric Central Air, 12 SEER or higher Make and Model Number 2. Furnace 2: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVACPipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: IMM mw�i Assembly Type Comments/ Description Window Area Total: 132.00 10/09/0315:20:12 1 /1 L-.Ij i Area Calculator: IMM Assembly Type Comments/ Description Opaque door solid masonite Door Area Total: 71.11 10/09/03 15:20:12 1 /1 I* O Area Calculator: Assembly Comments/Description Ceiling Area Total: 1139.00 10/09/03 15:20:13 1 /1 a s Area Calculator: Assembly Type Comments/Description m■�■�� Exterior Wall Area Total: 1186.67 10/09/03 15:20:14 1 /1 0 s Area Calculator: Assembly Comments/Description Floor Area Total: 0.00 10/09/03 15:20:14 1 /1 s