HomeMy WebLinkAboutRES2003-03150 3702 MEADOW VIEW DR BUILDING PERMIT03 315b
03- 3�St C�
MCI,.
2)
0
PREPARED 2/10/04, 8:06:18 INSPECTION TICKET PAGE 2
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/10/04
------------------------------------------------------------------------------------------------
ADDRESS 3702 MEADOW VIEW DR SUBDIV: WESTFIELD ADDITION PH 3
CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER BCS DEVELOPMENT CO PHONE
PARCEL 650700-0308-0030
APPL NUMBER: 03-00003150 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 11/04/03 CW BLDG, FOUNDATION -SLAB TIME: 17:00
11/05/03 AP 11/04/2003 08:51 AM GCARRILLO
t.. SLAB GROUND LEFT SIDE 4' FROM WALL (REAR) STRINGS OK
01 12/10/03 DS BLDG, FRAMING TIME: 17:00
12/10/03 AP 12/09/2003 02:09 PM GCARRILLO
B130 01 12/11/03 CH BLDG, INSULATION TIME: 17:00
12/12/03 AP 12/11/2003 01:31 PM SSTANLEY
NEED FIREBLOCKING ABOVE FIREPLACE
B125 01 2 0/04 BI, BLDG, FINAL TIME: 17:00
02/09/2004 10:35 AM SSTANLEY
------------ �- 0 ----- COMMENTS AND NOTES
�0 jrf y*1 'oti-
V
City
of Colle e S ation
�OREQUEST
PAGE
'].
REQ/JOB:
WF0468702 / 001 PROJECT:
REQUEST DATE:
10/222PRINT 2/03
CREW:
PRINT TIME:
11:19:18
SCHEDULE
DATES
LOCATION:
3702 MEADOW VIEW DR
03
77845
COMPLETION:
10/22/03
GEN. LOC:
COLLEGE STATION
LOC ID: 193396
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION
PRIORITY:
NORMAL
REQUESTOR:
STYLECRAFT BUILDERS
ORIGIN:
CUSTOMER -WALK
IN
USER ID:
MALFORD AUTH: MALFORD
WORK TYPE:
ROUTINE
TEMP POLE PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
REScheckSoftware Version 3.5 Release la
Data filename: S:\ACAD\REScheck\1226-1215—Meadow View.cck
TITLE: PLAN # 1226-1215
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 10/09/03
DATE OF PLANS: 10/10/03
PROJECT INFORMATION:
Spec
3702 Meadow View
College Station, Texas
COMPANY INFORMATION:
Stylecraft Builders, Inc.
4090 St. Hwy. 6 S.
College Station, Texas 77845
COMPLIANCE: Passes
Maximum UA = 544
Your Home UA = 442
18.8% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.40
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter R-Value
R-Value
U-Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
830
30.0
0.0
29
Ceiling 2: Cathedral Ceiling (no attic)
385
19.0
0.0
20
Wall 2: Wood Frame, 16" o.c.
1353
13.0
0.0
95
Window 4: Metal Frame, Double Pane with Low-E
142
0.670
95
SHGC: 0.40
Door 3: Solid
38
0.500
19
Door 5: Glass
18
0.440
8
SHGC: 0.40
Floor 1: Unheated
169
0.0
176
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 12 SEER
Furnace 1: Forced Hot Air, 80 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release la (formerly MECchecl and to comply with the mandatory requirements listed in
the REScheckInspectio 9,ehecklist.
Builder/Designer `- Date (U D
r t � •
REScheck Inspection Checklist
2000 IECC
REScheckSoftware Version 3.5 Release la
DATE: 10/09/03
TITLE: PLAN #1226-1215
Bldg.
Dept.
Use
[ ]
[ ]
[ ]
[ ]
[ )
[ )
[ ]
[ ]
[ ]
Ceilings:
1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments:
Above -Grade Walls:
1. Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
1. Window 4: Metal Frame, Double Pane with Low-E, U-factor: 0.670
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
1. Door 3: Solid, U-factor: 0.500
Comments:
2. Door 5: Glass, U-factor: 0.440
Comments:
Floors:
1. Floor 1: Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
1. Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
2. Furnace 1: Forced Hot Air, 80 AFUE or higher
Make and Model Number
Solar Heat Gain Coefficient:
[ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ) Materials and equipment must be identified so that compliance can be determined.
0
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly
marked on the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
Cooling ducts with exterior insulation must be covered with a vapor retarder.
Air filters are required in the return air system.
The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 T must be insulated to the
levels in Table 2.
•
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature ( F)
Up to 1„
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Piping System Types
Range F
2" Runouts
1" and Less
1.25"
to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
Area Calculator:
Add to
Library
Window
Name
Assembly Type
Quantity
Width
x Height
Unit
Area
Total
Area
U-Factor
SHGC
Comments/
Description
1
3050 Twin
Metal Frame, Do
1
6'-0"
5'-0"
30.00
30.00
ft2
0.670
2
1450
Metal Frame, Do
2
1'-4"
5'-0"
6.67
13.34
ft2
0.670
3
0850
Metal Frame, Do
1
0'-8"
5'-01,
3.33
3.33
ft2
0.670
4
3050
Metal Frame, Do
1
T-0"
5'-0"
15.00
15.00
ft2
0.670
5
4040
Metal Frame, Do
1
4'-0"
4'-0"
16.00
16.00
ft2
0.670
6
2850 Twin
Metal Frame, Do
1
5'-4"
5'-0"
26.67
26.67
ft2
0.670
7
2850
Metal Frame, Do
2
2'-8"
5'-0"
13.33
26.66
ft2
0.670
8
4008
Metal Frame, Do
1
4'-0"
0'-8"
2.67
2.67
ft2
0.670
9
2814
Metal Frame, Do
1
2'-8"
1'-4"
3.56
3.56
ft2
0.670
101
130 RT
Metal Frame, Do
1
T-0"
1'-6"
4.50
4.50
ft2
0.670
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Window Area Total: 141.73
10/09/03 15:38:10 1 /1
0
•
Area Calculator:
100�,
Assembly Type
Comments/
Description
Opaque door solid
'mom
��■�■�����
Door Area Total: 55.56
10/09/03 15:38:11 1 /1
I*
40
Area Calculator:
Assembly Type-
Comments/Description
Ceiling Area Total: 1215.00
10/09/03 15:38:11 1 /1
i
Area Calculator:
IN
----AssemblyType
Comments/Description
m
■�■�=
Exterior Wall Area Total: 1353.33
10/09/03 15:38:12 1 /1
Area Calculator:
Assembly
Comments/Description
MINTIMIMMIRTMIM..■�■
•• ��
Floor Area Total: 0.00
10/09/0315:38:13 1/1
City of College St -pion
WORKUEST
REQ/JOB: WF0467514 / 001 PROJECT:
CREW:
PAGE 1
03
PRINT DATE: T DATE: 10/15/ INT03
PRINT TIME: 16:23:15
SCHEDULE DATES
LOCATION: 3702 MEADOW VIEW DR 03
77845 COMPLETION: 10/15/03
GEN. LOC: COLLEGE STATION LOC ID: 193396
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN
USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE
4" SEWER TAP AND 3/4" WATER TAP
4" SEWER TAP AND 3/4" WATER TAP
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
a B.UZLD_TN.G. PERMIT ._
�i CI.T.Y�QF_.CQ
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
. . . 03-00003150 Date 10/15/03
Property Address . . .
. . . 3702 MEADOW VIEW DR
Property ID
. . 650700-0308-0030
R # . . . . . . . . . .
. . . R*****
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . .
. . . WESTFIELD ADDITION PH 3
Property Use . . . . .
. . . RESIDENTIAL
Property Zoning . . . .
. . . SINGLE FAMILY RESIDENTIAL
Application valuation .
. . . 80190
Owner
Contractor
------------------------
BCS DEVELOPMENT CO
------------------------
STYLECRAFT BUILDERS
4112 SH-6 S
RANDY FRENCH
COLLEGE STATION TX
77845 4090 SH 6 SOUTH
COLLEGE STATION TX 77845
(979) 690-1222
------ Structure Information
SINGLE FAMILY -----
Construction Type . . .
. . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . .
. . RESIDENTIAL-SFR/DUPLEX
Other struct info . . .
. . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1215.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
SERIAL ZONES 248.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING
PERMIT
Additional desc . . MA
Permit Fee . . . .
384.00 Plan Check Fee .00
Issue Date . . . . 10/15/03
Valuation . . . . 80190
Expiration Date . .
4/13/04
Qty Unit Charge Per
Extension
BASE FEE 260.00
31.00 4.0000 THOU
BLDG, VAL 50001-100000 124.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT
SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE
PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
---------------------- ----------------------------
BUILDING DEPT�REPRESENTATIVE:
APPLICANT: L" v)
BUILDING PERMIT
CITY OF COLLEGE STATION •
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00003150
Page 2
Date 10/15/03
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR,
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Other Fees . . .
Fee summary
. . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Charged Paid Credited Due
---------------------- A ---------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: 44,�_ ��
BUILDING PERMIT
• CITY OF COLLEGE STATION •
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Permit Fee Total 384.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1134.00
03-00003150
384.00
.00
75Q.00
1134.00
.00
.00
.00
.00
Page 3
Date 10/15/03
.00
.00
.00
.00
----- -------------------11 - --------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: l/L✓
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00003151 Date 10/15/03
Property Address . . . . . . 3702 MEADOW VIEW DR
Property ID . . 650700-0308-0030
R # . . . . . . . . . . . . . R*****
Application description . . . TEMP POLE
Subdivision Name . . . . . . WESTFIELD ADDITION PH 3
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
BCS DEVELOPMENT CO STYLECRAFT BUILDERS
4112 SH-6 S RANDY FRENCH
COLLEGE STATION TX 77845 4090 SH 6 SOUTH
COLLEGE STATION TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . MA
Permit Fee . . . . 20.00
Issue Date . . . . 10/15/03 Valuation . . . . 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00
Fee summary
-----------------
Permit Fee Total
Other Fee Total
Grand Total
Charged Paid
--------------------
20.00 20.00
45.00 45.00
65.00 65.00
Credited Due
--------------------
.00 .00
.00 .00
.00 .00
----------------------- - - h ---------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
0
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
E3 1101 TEXAS AVENUE Q�
..��.� 0 COLLEGE STATION, TX 77840
110
(979) 764-3570 (979) 764-3496 FAX
I ('✓ ` !1 WWW.CI.COLLEGE-STATION.TX.US
;Klr"
�`AJDDRESS/L CATION
3 � Q
LOT BLOCK u
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20
�Oa AAetij0vy View
DATE:
Fa Office Use Only
/P-r 4-o 3
APPLICATION #
TEMP POLE #
SUBDIVISION We S f ' 1'P 4 PHASE 3
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20
CONTRACTOR ADDRESS: 4090 State Highway 6 South
ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing
HVAC: Control Temp GOOD CENTS (Residential only): No
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL
DESCRIPTION OF WORK: Conventional Framing
STRUCTURE USE: Sinale Family Residence
HOMEOWNER ASSOC IATI ON/ARC H ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: f
TEXAS ACCESSIBILITY STANDARD (TAS) PR ECT REGISTRATION# EABPRJ N/A
VALUATION: $ �► I d a . 00 TOTAL AREA: 171 b HEATED AREA: ) 215
(Cost of Labor and Materials)
❑X PUBLIC SEWER NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
�X SEWER TAP:
4"
INTERIOR WALL TYPE:
Sheet Rock
SIZE
�X WATER TAP:
3/a"
EXTERIOR WALL TYPE:
Siding and/or Masonry
SIZE
OTHER TAP:
FOUNDATION TYPE:
Slab on Grade
SIZE
❑X TEMP POLE
ROOF TYPE:
Composition
GARAGE TYPE:
SINGLE F—]
DOUBLE FX TRIPLE
ATTACHED XJ
DETACH1ED�� CARPORT
e"7SIGNATURE
OF APPLICANT: 7
-
For Stylecraft
i
Official Use Only
o
YES NONO
Plans Examiner
Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls ()
Insulation R value of exterior walls R13
Insulation R value of ceiling I (flat areas) R30
Insulation R value of ceiling 2 (vaulted areas/no attic) R19
Glazing SHGC .40
Glazing U-Factor .65
R value of ductwork R6
A/C SEER rating 12