Loading...
HomeMy WebLinkAboutRES2003-03148 3704 MEADOW VIEW DR BUIDING PERMIT03.31ut p3_ 3 W CUANIP) 0 0 M, 01 i r PREPARED 1/28/04, 7:31:55 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 1/28/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 3704 MEADOW VIEW DR SUBDIV: WESTFIELD ADDITION PH 3 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER BCS DEVELOPMENT CO PHONE PARCEL 650700-0308-0040 APPL NUMBER: 03-00003148 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 10/31/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 10/31/03 AP 10/30/2003 08:02 AM MALFORD a slab ground back right side B 01 12/02/03 DS BLDG, FRAMING TIME: 17:00 12/02/03 DP 12/02/2003 09:02 AM SSTANLEY ' 12/03/2003 06:56 AM MALFORD r needs to sheetrock top of fireplace and needs to finish band going into master bedroom and past master bath B115 02 12/03/03 CH BLDG, FRAMING TIME: 17:00 12/03/03 AP 12/03/2003 09:37 AM SSTANLEY B130 01 12/08/03 OC BLDG, INSULATION TIME: 17:00 12/08/03 AP 12/05/2003 08:40 AM SSTANLEY MORNING B125 01 1/26/04 TB BLDG, FINAL TIME: 17:00 1/26/04 DP O1/26/2004 10:27 AM GCARRILLO Lawn Irrigation System Not Installed House Locked B125 02 1/28/04 BI BLDG, FINAL TIME: 17:00 O1/27/2004 03:46 PM GCARRILLO 0 ---------------------------------- COMMENTS AND NOTES 100 City of College Station WORK WUEST PAGE 1 REQ/JOB: WF0467512 / 001 PROJECT: REQUEST DPRINT ATE: 10/15/03 CREW: PRINT TIME: 16:21:58 SCHEDULE DATES LOCATION: 3704 MEADOW VIEW DR 03 77845 COMPLETION: 10/15/03 GEN. LOC: COLLEGE STATION LOC ID: 193398 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE 4" SEWER ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- TAP AND 3/4" WATER TAP 4" SEWER TAP AND 3/4" WATER TAP Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release la Data filename: S:\ACAD\REScheck\1545-3704 Meadow View.cck TITLE: Plan # 1545 WF CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 10/09/03 DATE OF PLANS: 10/10/03 PROJECT INFORMATION: Hernandez 3704 Meadow View College Station, TX 77845 COMPANY INFORMATION: Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 COMPLIANCE: Passes Maximum UA = 611 Your Home UA = 526 13.9% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E SHGC: 0.40 Door 1: Solid Door 2: Glass SHGC: 0.40 Floor 1: Unheated Insulation depth: 0.0' Air Conditioner 2: Electric Central Air, 12 SEER Furnace 2: Forced Hot Air, 80 AFUE Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1067 30.0 0.0 37 466 19.0 0.0 24 1455 13.0 0.0 98 201 0.670 135 38 0.500 19 18 0.580 10 195 0.0 203 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release la (formerly MECchecl and to comply with the mandatory requirements listed in the RES checkInspection Checklist. / Builder/Designer Date (� (0 0 3 REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.5 Release la DATE: 10/09/03 TITLE: Plan # 1545 WF Bldg. Dept. Use Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 1: Solid, U-factor: 0.500 Comments: 2. Door 2: Glass, U-factor: 0.580 Comments: Floors: 1. Floor 1: Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Air Conditioner 2: Electric Central Air, 12 SEER or higher Make and Model Number 2. Furnace 2: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 1 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 T must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: Assembly Type Comments/ Description Window Area Total: 200.84 10/09/03 15:36:01 1 /1 Area Calculator: w, mm Assembly Type Comments/ Description Opaque door solid Door Area Total: 55.56 10/09/03 15:36:01 1 /1 Area Calculator: Assembly Ceiling Area Total: 1533.00 10/09/03 15:36:02 1 /1 Area Calculator: 0 Assembly Type Comments/Description Exterior Wall Area Total: 1455.33 10/09/03 15:36:02 1 /1 Area Calculator: Assembly Type©tea MComments/Description Floor Area Total: 0.00 10/09/03 15:36:03 1 /1 -� LTILI,I�TGz FERMZT •:'O,LEE ",STATION 1101 TEXAS AVE - COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003148 Date 10/15/03 Property Address . . . . . . 3704 MEADOW VIEW DR Property ID . . 650700-0308-0040 R# . . . . . . . . . . . . . R***** Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD ADDITION PH 3 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 102366 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4112 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1551.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . MA Permit Fee . . . . 469.00 Plan Check Fee .00 Issue Date . . . . 10/15/03 Valuation . . . . 102366 Expiration Date . . 4/13/04 Qty Unit Charge Per Extension BASE FEE 460.00 3.00 3.0000 THOU BLDG, VAL 100001-500000 9.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) ----- ----------------- ---- BUILDING DEPT REPRESENTATIVE- --:--�� ----------------------- ' APPLICANT: ��' BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00003148 Date 10/15/03 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited Due ------------------------------ --------------------------- Permit Fee Total 469.00 469.00 .00 .00 Plan Check Total .00 .00 .00 .00 --------------------------------------- - --------------------------- BUILDING DEPT R PRES`ENNTATIVE: APPLICANT: C/ C/ BUILDING PERMIT • CITY OF COLLEGE STATION • 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 03-00003148 Date 10/15/03 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1219.00 1219.00 .00 .00 --------------------- -------------------------- BUILDING DEPT REPRESENTATIVE: --��`A APPLICANT: "/� C/C/ TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003149 Date 10/15/03 Property Address . . . . . . 3704 MEADOW VIEW DR Property ID 650700-0308-0040 R # R***** Application description . . . TEMP POLE Subdivision Name . . . . . . WESTFIELD ADDITION PH 3 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4112 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . MA Permit Fee . . . . 20.00 Issue Date . . . . 10/15/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------------ - -------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: I APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1 1101 TEXAS AVENUE/ COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US F- 0f.. U- O.,y DATE: ' m" n4-o-3 t�.Q APPLICATION # 3 J 1 V TEMP POLE #y 3 - 2v' 4-9 VDRESCATION:S/LO7 U MP �i c� �/wV �'P w T I /BLOCK O SUBDIVISION �P S'f T P I PHASE tPL BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 1 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbinq HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Single Familv Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: f TEXAS ACCESSJ131LITY STANDARD (TAS) PROJECT REGISTRATION# EABPR VALUATION: 71 Q7. 3 TOTAL AREA: 5 HEATED AREA: (Co a or and Materials) OX PUBLIC SEWER 100L (- l" NUMBER OF BEDROOMS. SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: or, �X SEWER TAP: 4" INTERIOR WALL TYPE: Sheet Rock SIZE �X WATER TAP: 3/a" EXTERIOR WALL TYPE: Skiing and/or Masonry SIZE OTHER TAP: FOUNDATION TYPE: Slab on Grade SIZE TEMP POLE ROOF TYPE: Composition GARAGE TYPE: SINGLE DOUBLE � TRIPLE ATTACHED FT] DETACHED F__] CARPORT SIGNATURE OF APPLICANT: For Stvlecraft Official Use Only t'1 10 CL3 NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls 4 % Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork R6 A/C SEER rating 12