HomeMy WebLinkAboutRES2003-03138 2313 NORHAM DR BUILDING PERMITrc)o
0
0
0
uu� �k�;ncs
mom•;
4.
0
City of College St ion
WORK UEST_--
REQ/JOB: WF0467095 / 001 PROJECT:
CREW: '�
}
PAGE 1
REQUEST DATE: 10/14/03
PRINT DATE: 10/14/03
PRINT TIME: 9:36:55
SCHEDULE DATES
LOCATION:
2313 NORHAM
DR
START:
77845 COMPLETION: 10/14/03
GEN. LOC:
COLLEGE STATION
LOC ID: 197924
REF NBR: ;
REQ DEPT:
DE -BUILDING
INSPECTION
PRIORITY: NORMAL
REQUESTOR:
TDT HOMES
ORIGIN: CUSTOMER -WALK IN
USER ID:
MALFORD
AUTH: MALFORD
WORK TYPE: ROUTINE
4" SEWER
TAP AND 3/4'
WATER TAP
4" SEWER TAP AND 3/4' WATER TAP
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
"I
PREPARED 2/04/04, 7:37:45 INSPECTION TICKET PAGE 6
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/04/04
------------------------------------------------------------------------------------------------
ADDRESS . : 2313 NORHAM DR SUBDIV: CASTLEGATE SEC 10,11,12,13
CONTRACTOR T D T HOMES PHONE (979) 690-7117
OWNER GREENS PRAIRIE INVESTORS LTD PHONE
PARCEL 184200-0104-0020
APPL NUMBER: 03-00003138 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 10/23/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00
10/23/03 AP 10/22/2003 03:44 PM MALFORD
afternoon please on 10/23/03
10/24/2003 06:50 AM MALFORD
slab ground front left corner in garage strings on set
backs ok
i B115 01 11/19/03 OC BLDG, FRAMING TIME: 17:00
11/20/03 AP 11/19/2003 11:44 AM MALFORD 1v,
jB125 01 ,,2/'04�/0�� BLDG, FINAL TIME: 17:00
_ 02/03/2004 04:50 PM MALFORD
----------------------------------- CONTINUED ONTO NEXT PAGE -----------------------------------
I 't
City of College Station
WORK REQUEST
REQ/JOB: WF0465964 / 001
CREW:
PAGE 1
PROJECT: PRINT DATE: T DATE: 10/08/03
PRINT TIME: 8:09:27
LOCATION: 2313 NORHAM DR SCHEDULE
STTART:DATES 10/08/03
77845 COMPLETION: 10/08/03
GEN. LOC: COLLEGE STATION LOC ID: 197924
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: T D T HOMES ORIGIN: CUSTOMER -WALK IN
USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE
TEMP POLE PASSED
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
BUILDING PERMIT
COLLEGE STAT,T.Ofq
1 T'�XAS AV� t
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
-----------------------------------------------------------------------------
Application Number . . . . . 03-00003138 Date 10/14/03
Property Address . . . . . . 2313 NORHAM DR
Property ID . . . . . . . . . 184200-1004-0020
R 4 . . . . . . . . . . . . . R*****
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . CASTLEGATE SEC 10
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 101376
Owner Contractor
------------------------ ------------------------
GREENS PRAIRIE INVESTORS LTD T D T HOMES
4490 CASTLEGATE DR GLENN THOMAS
COLLEGE STATION TX 778453388 1110 12TH MAN
COLLEGE STATION TX 77845
(979) 690-7117
------ Structure Information SINGLE FAMILY -----
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID N
FOUNDATION TYPE CONCRETE
NUMBER OF GARAGE BAYS 2.00
HEATED AREA 1536.00
INTERIOR WALL TYPE S/R
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
SERIAL ZONES 249.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . MA
Permit Fee . . . . 466.00 Plan Check Fee .00
Issue Date . . . . 10/14/03 Valuation . . . . 101376
Expiration Date . . 4/12/04
Qty Unit Charge Per Extension
BASE FEE 460.00
2.00 3.0000 THOU BLDG, VAL 100001-500000 6.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
----------------------------- -------- - f--------------------------
BUILDING DEPT (V TATI� C�A
APPLICANT':
s
BUILDING PERMIT
• CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 03-00003138 Date 10/14/03
----------------------------------------------------------------------------
Special Notes and Comments
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Fee summary
BUILDING L
APPLICANT;
Charged Paid Credited Due
BUILDING PERMIT
• CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Permit Fee Total 466.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1216.00
-------------------
BUILDING DE
APPLICANT:
03-00003138
466.00
.00
750.00
1216.00
.00
.00
.00
.00
Page 3
Date 10/14/03
.00
.00
.00
.00
jE3AP�PLLIFCATION FOR BUILDING PI:RW
CCOI.I.EGE STATION
11VrTEXAS AVENUE
COLLEGE STATION. TX 77840
(979) 76"570 (979) 764-3496 FAX
Www-CLC0I I EGE-STATKMTXAM
ADDRESS/LOCATION: �75 1.3 'HAM
LOT z BLOCK —__ SUBDMSION & -C- 4
BUSINESS/OWNER NAME: _yinIg S PHONE: to 9 U
CONTRACTOR/HOMEOWNER: --L-D 1 ' 5 PHONE:
CONTRACTOR ADDRESS: 5 SS: (t'), t �- �?�77��-
ELECTRICIAN: tt-: PLUMBER:
/Z e
HVAC: Ct z +r- S GOOD CENTS (Residential Gray): L —
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) K NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING_ POOL
DESCRIPTION OF WORK: IJc-Ck)
STRUCTURE USE:
HOMEOWNER ASSOCIATIOWARCHTTECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBItqY STANDARD (fAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ mV TOTAL AREA-.Zf) t;(. HEATED AREA:
(Costorl and Materials)
LAdPUBLIC SEWER I J� NUMBER OF BEDROOMS:
❑� SEPTIC/TREATMENT SYSTTEM
SEWER TAP: t`
S¢E
N WATER TAQ: 3 ! 14
❑ OTHER TAP:
saE
❑ TEMP POLE (J��
GARAGE TYPE: SINGLE ❑
ATTACHED
SIGNATURE OF APPLICANT:
NUMBER OF BATHROOMS:
INTERIOR WALLTYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
� • rwvo�
TRIPLE ❑
ART ca
Otfidal Use Only
C� 1b�131o3 ts:
O
Plans Examiner , , Zoning Official
0
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
raj
Insulation R value of ceiling 1 (flat areas)��
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
' 3
Glazing U-Factor
t
R value of ductwork
A/C SEER rating
L o� I
giv-'c'A
<<wf, Io
UJ0
1
'
O
1
IA-
'
00
p53tQt
i
�.._
LOT "I-
—
3
T
block 4
2313
—r'D " i" ti � W il}
d! lU t2—
T'DT Hann&S 1103
Lo4 3
`3 to rA 1-1
t1ok. ! D
i
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# DATE:
03-3139 1 0 I i 310
BUILDING ADDRESS:
„13i� IVol�am 1)�w�
I. Foundation Requirements
NA/OK
A. Concrete minimum f'c of 3000 PSI
OK
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' Ion
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/OK
A. Girder or sill dimensions, grade & species
NA
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
1. One -hour rated extending to roof deck
E. Header sizes indicated on plans
bK
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
•
•
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
NA/OK
M. Span exceeding code tables must be engineered
®j�
N. Rafter size, spacing, grade, roof slope & bracing (if required to reduce span) indicated
on plans
O. Roof covering
1. Roof decking.indicated on plans
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs not allowed on zero lot line construction
S. Protected openings on walls < three feet from property line
AA
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements (to be indicated on plans)
NA/OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
0
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
•
•
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of
the building within ten 10 feet horizontal
V. Electrical Service Requirements
NAtOK
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
NA/OK
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/OK
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
N
OK
A. Compliance software worksheet MECcheck submitted, or
Q
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/OK
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Overhangs not allowed on zero lot line construction
20' triangle clear at corner
Required parking
Street Ordinance Requirements
N
OK
Maximum drive width for residence is 28'
Minimum 30 feet from driveway to side(intersecting) street
--
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
Subdivision Regulations — Ordinance 690 NA/OK
Approved subdivision OK
Plat filed
Flood lain Regulations — Ordinance 1301 OK
Does not block any water course
Need elevation certificate
ZONING OFFICIAL
DATE
(f N jq i *3
PLANS EXAMINER DATE
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release la
Data filename: C:\Program Files\Check\REScheck\REScheck docs\163TDT.rck
TITLE: TDT Job 163
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 10/ 10/03
DATE OF PLANS: October 10, 2003
PROJECT INFORMATION:
TDT 163
2313 Norham Drive
College Station, Texas 77845
COMPANY INFORMATION:
TDT Homes
1110 12th Man Court
College station, Texas 77845
NOTES:
Like Home at 108 Hartford
COMPLIANCE: Passes
Maximum UA = 653
Your Home UA = 473
27.6% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.34
Ceiling l: Flat Ceiling or Scissor Truss
Ceiling 2: Cathedral Ceiling (no attic)
Wall 1: Wood Frame, 16" o.c.
Window 1:
Metal Frame with Thermal Break:Double Pane with Low-E
SHGC: 0.34
Door l: Solid
Door 2: Glass
SHGC: 0.34
Floor 1: Slab-On-Grade:Unheated
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor
UA
1512
30.0
0.0
53
24
19.0
0.0
1
1728
13.0
3.4
105
187
0.650
122
21
0.400
8
21
0.650
14
163
0.0
170
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
Furnace 1: Forced Hot Air, 80 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in RES checkVersion 3.5 Release I a (formerly MECchecl and to comply with the mandatory requirements listed in
the REScheckInspection Checklist.
Builder/Designer Date �� ��
REScheck Inspection Checklist
2000 IECC
REScheckSoftware Version 3.5 Release la
DATE: 10/ 10/03
TITLE: TDT Job 163
Bldg.
Dept.
Use I
Ceilings:
1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments:
Above -Grade Walls:
1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-3.4 continuous insulation
Comments:
Windows:
1. Window 1: Metal Frame with Thermal Break:Double Pane with Low-E, U-factor: 0.650
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
1. Door 1: Solid, U-factor: 0.400
Comments:
2. Door 2: Glass, U-factor: 0.650
Comments:
Floors:
1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
1. Air Conditioner 1: Electric Central Air, 13 SEER or higher
Make and Model Number
2. Furnace 1: Forced Hot Air, 80 AFUE or higher
Make and Model Number
Solar Heat Gain Coefficient:
The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly
marked on the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] ( Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
00. 0 0
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in
Inches by Pipe Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature ( F)
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Piping System Types
Range F
2" Runouts
1" and Less
1.25"
to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)