HomeMy WebLinkAboutRMDL2003-03093 1031 ROSE CIR BUILDING PERMITBUILDING PERMIT
v C ICI W STAT I ON"
. EXAAVE'
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00003093 Date 10/09/03
Property Address . . . . . . 1031 ROSE CIR
Property ID . . . . . . . . . 592000-0002-0010
R ## R44839
Application description . . . RESIDENTIAL, REMODEL & RENOVATION
Subdivision Name . . . . . . SWEET BRIAR
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 25000
Owner Contractor
------------------------ ------------------------
CARLSON, DAVID L & SHAWN B D & L CONSTRUCTION
1031 ROSE CIR 1027 ROSE CIRCLE
COLLEGE STATION TX 778402327 COLLEGE STATION TX 77840
( 97) 694-1522 (979) 693-0146
-------------------------- Structure Information -------------------------
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . IMPACT/PRORATA FEES PAID NA
HEATED AREA 357.00
INTERIOR WALL TYPE SHHETROCK
SEWER TYPE PUBLIC
SERIAL ZONES 184.00
----------------------------------------------------------------------------
Permit BUILDING PERMIT
Additional desc MA
Permit Fee . . . . 135.00 Plan Check Fee .00
Issue Date . . . . 10/09/03 Valuation . . . . 25000
Expiration Date . . 4/07/04
Qty Unit Charge Per Extension
BASE FEE 15.00
24.00 5.0000 THOU BLDG, VAL 1001-50000 120.00
----------------------------------------------------------------------------
Special Notes and Comments
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
POST PERMIT CARD ON JOB SITE
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
BUILDING`` PT REPRESENTATIVE: C'
APPLICANT: �� Q
BUILDING PERMIT
CITY OF COLLEGE STATION •
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 03-00003093 Date 10/09/03
----------------------------------------------------------------------------
Special Notes and Comments
of 12 or more.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
need exhaust fan or operable window in toilet area
need R-13 insulation in the wall and R-30 in the ceiling
Fee summary Charged Paid Credited Due
------------------------------------------------------
Permit Fee Total 135.00 135.00
Plan Check Total .00 .00
Grand Total 135.00 135.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
.00 .00
.00 .00
.00 .00
U
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
E3 1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
ADDRESS/LOCATION: / 031 ?�Ms-e C"rC\ P
1For Office U_ l
DATE: � / I , N
APPLICATION # lV W
TEMP POLE #
t
�dh
LOT BLOCK SUBDIVISION SEC/PH
BUSINESS/OWNER NAME: \) L L �t% 4—TN`` PHONE: �T 3 -o 4
CONTRACTOR/HOMEOWNER: 51o. ���a�:�. 150 PHONE:
CONTRACTOR ADDRESS: / a Zrl C 4L— (ii rG1Q
ELECTRICIAN: 2CPLUMBER: &V-Yp jfAt vkr'&4
HVAC: GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans MODEURENOVATION SWIMMING POOL ;.
Req)
DESCRIPTION OF WORK: vt Q— h Zo Q_
STRUCTURE USE: "'r (' kleolt"at I
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCE BILITY STANDARD (TAS) PjtOJECT REGISTRATION# EABPRJ
VALUATION �iJ D C1 U " o' '� TOTAL AREA: % HEATED AREA:
(Cost dLabor and Materials)
PUBLIC SEWER NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
SEWER TAP: INTERIOR WALL TYPE: s w �;(� Q uJ d. Its
SIZE
WATER TAP: EXTERIOR WALL TYPE:
SIZE
❑ OTHER TAP:
TEMP POLE
GARAGE TYPE:
FOUNDATION TYPE:
ROOF TYPE:
SINGLE a DOUBLE a
ATTACHED a DETACHED a
SIGNATURE OF APPLICANT:
TRIPLE a
CARPORT
Official Use Only
Gewjnents:
YES r NO
Plans Examiner Zoning Official
s
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
0
0
Y
a
4 5ft
A