Loading...
HomeMy WebLinkAbout06-3088 City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date 8/13/07 Parcel Number 144500- 0002 -0010 Property Address . . 401 UNIVERSITY DR COLLEGE STATION TX 77840 Subdivision Name . . . Legal Description . . . BOYETT, BLOCK 2, LOT 1,2,3 & P ART OF 4 Property Zoning . . . GENERAL COMMERCIAL Owner SHELTON FAMILY PARTNERSHIP Contractor THE CORNER BAR 979 268 -1406 Application number . . 06- 00003088 000 000 Description of Work . . COMMERCIAL, AMUSEMENT /SOCIAL /RECREATION Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . ASSEMBLY (IBC) Flood Zone Approved C" Building fficial VOID UNLESS SIGNED BY BUILDING OFFICIAL C!� F -- Z W U O M M w to w w 0 i 0 0 0 - M06 LU ¢a P%d� 4 w �' F- .� S z 0 c tD H � z X N CU 0 s . cm) u F- z O cn Q N 00 cn co Od R cu I `� fl cc cno W cv 0 w CO o 0 rte- t� 0 M W t Z U0, p Q LLI u O Wd tnWCO Lu Lu v �fz UO ('3Wcr � CC 0_,�a�a C y ft m Z C ® 0) I- % UJ J ( U �a.. c v) 0PROJECT NO. 207.19 _ 0 c DRAWN RY: M /AH v •� CHECKED RY: acH 6.� Giy cc CONTRACTISSUE DATE: 05-29-08 REVISIONS 06-06-08 Holster A AIRDESIGN 0 Ig 7607 Eastmark Drive, Suite # 200 College Station, Texas 77840 979.693.3179 VICINITY MAP & PROJECT LOCATION_ SCALE: NT$ PROJECT INFORMATION & BASIC CODE OVERVIEW, CODE INFORMATION SUMMARY PROJECT MEETS THE REQUIREMENTS OF: American Disabilities Act Texas Accessibility Standards APPLICABLE CODES: International Building Code Life Safety Code International Plumbing Code National Electric Code International Energy Code State and Federal Codes BUILDING OCCUPANCY GROUP: CH 3 ccupancy roup - Tavem / Bar / Nightclub GENERAL BUILDING HEIGHT & AREAS: CH 5 ROOM NUMBER MARKS 13,160 SQ FT INDICATES ROOM NO 115 ELEVATION MARKS Gross Area per Floor: Existing Proposed - BUILDING ELEVATIONS Basement NA NA ENLARGED AREA First Floor 4610 SQ FT NA - ELECTRICAL LIGHTING PLAN Second Floor 4610 SQ FT NA SECTION MARKS Third Floor NA 3940 SQ FT - STAIR FRAMING PLAN Fourth Floor NA NA DOOR MARKS Addition of Rooftop Patio DOOR NUMBER 24 DOOR SCHEDULE Total Building Height (FT): 38'-2" at ROOF [3rd Floor Bar] Re: Total Building Stories: Three Story O =� FLOOD PLAIN: Service Sink: 1 Required Re: WINDOW SCHEDULE FEMA MAP # 48041C0144C A _ PANEL 144 of 150 = 2 ExitSr Req'd i = f DATED JULY 1992 AA 0 GRAPHIC SYMBOLS LEGEND ROOM NUMBER MARKS '� '� 5 INDICATES ROOM NO 115 ELEVATION MARKS 3/A3 REFERS TO ELEVATIONAL DETAIL NUMBER 3 ON SHEET A3 - BUILDING ELEVATIONS SHEET A3.1 - BUILDING SECTIONS ENLARGED AREA 2/A9 REFERS TO ENLARGED DETAIL - ELECTRICAL LIGHTING PLAN SHEET S1.1 NUMBER 2 ON SHEET A9 SECTION MARKS - ROOF FRAMING PLAN REFERS TO SECTION DETAIL - STAIR FRAMING PLAN 2/A4 NUMBER 2 ON SHEET A4 DOOR MARKS �'I LLLLLU - 11RIGID DOOR NUMBER 24 DOOR SCHEDULE ® Re: WINDOW MARKS O WINDOW TYPE A o Service Sink: 1 Required Re: WINDOW SCHEDULE GRID LINES A NOTES GRID LINE "A" fra r��'�ga 5:... �,.r skr•ir. = 2 ExitSr Req'd INDICATES WALL TYPE 1A WALL TYPES AA REFER TO WALL SECTIONS NOTE REFERENCES Minimum Egress Width Required [Total] HANDICAPPED PROVISIONS: FLOOR DRAIN SYMBOL ®F.D. NOTES FLOOR DRAIN LOCATIONS FLOOR SINK SYMBOL Iii NOTES FLOOR SINK LOCATIONS FIRE EXTINGUISHER FEC NOTES LOCATION OF FIRE CABINET SYMBOL E] EXTINGUISHERS Re: Specs Water Closets: 1 4 0` NOTES SPECIAL AREAS OF ADAITAS SYMBOL = 92;4" > minimum of 36" ADAITAS COMPLIANCE Lavatories: 2 2 0 Ramps: O Existing - 0 New Elevator: 0 Existing - 0 New REFERS TO NOTE #2 ON THE SHEET NOTE O NOTES TO SHEET Drinking' Fountains: 0 0 0 C!:) cn CU 06 Q x308 _� L H INDEX OF DRAWINGS SHEET AO.1 - GENERAL BUILDING INFORMATION SHEET Al.1 - 3RD FLOOR PLAN SHEET A1.2 - CEILING AND ROOF PLAN SHEET A2.1 - BUILDING ELEVATIONS SHEET A3.1 - BUILDING SECTIONS SHEET E1.1 - ELECTRICAL POWER PLAN SHEET E1.2 - ELECTRICAL LIGHTING PLAN SHEET S1.1 - ROOF DECK SHEET S1.2 - ROOF FRAMING PLAN SHEET S1.3 - STAIR FRAMING PLAN 551 -r 55. t - L16Wr GAU6f, VIZA&W6 DexA1L5 SHEET MP1.1- MECHANICAL AND PLUMBING H Z W U O D D W W Material Symbols CONCRETE' EXISTING FIXTURE COUNT: CH 29 OCCUPANCY LOAD: CH 10TOTAL FIXTURE COUNT: CH 29 Existing Occupant Loads CITY OF COLLEGE STATION INFO: maximum is nce Travel to Maximum Dead End Corridor: 20'-0" First Floor = 180 Occupants EARTH FILL REQUIRED: GYPSUM ;•,., Second Floor = 154 Occupants MALE: FEMALE: UNISEX: V) Total. Existing Load = 337 Occupants C1 Urinals: 0 0 0 Water Closets: 4 4 0 Proposed Addition Occupant Loads �'I LLLLLU - 11RIGID Lavatories: 2 2 0 Drinking Fountains: 0 0 1 Occupancy Group = A-2 Uj Water Will Be Provided at Bar Service Space Function Sq Ft Usage. o Service Sink: 1 Required Z METAL , Tables & Chairs = 1131 Sq Ft E.I.F.S. SYSTEM fra r��'�ga 5:... �,.r skr•ir. = 2 ExitSr Req'd 15 sq ft netper Occupant CONTINUOUS ee NON-CONTINOUS WOOD Area Occupant Load = 226 Occupants Minimum Egress Width Required [Total] HANDICAPPED PROVISIONS: PROVIDED NEW; MALE: FEMALE: UNISEX: Standing Space = 1178 Sq Ft 0 Toilet Stalls: 0 Existing - 3 New Lavatories: 0 Existing - 2 New Egress Width = .3" x Occupant LoadUrinals: 5 sq ft net per Occupant 5 0 0 Drinking Fountains: 0 Existing - 0 New High/Low Cl) Area Occu ant Load = 79 Occupants P p =.3" x 308 Water Cooler: 0 Existing - 0 New Water Closets: 1 4 0` Miscellaneous Spaces Parking Spaces: 2 Existing - 0 New = 92;4" > minimum of 36" Area Occupant Load = 3 Occupants Lavatories: 2 2 0 Ramps: O Existing - 0 New Elevator: 0 Existing - 0 New CL TOTAL 3rd Floor Occupant Load = ` 308 Occupants H Z W U O D D W W Material Symbols CONCRETE' EXISTING FIXTURE COUNT: CH 29 CONCRETE (SECTe EGRESSITOTAL OCCUPANT LOADS; CH 10 CITY OF COLLEGE STATION INFO: maximum is nce Travel to Maximum Dead End Corridor: 20'-0" MALE: FEMALE: UNISEX: EARTH FILL - Northgate Core GYPSUM ;•,., Minimum Corridor Width; 3'-0" Urinals: 0 0 0 ` V) S ecial Desi n District ` p g C1 Minimum Clear Opening of Exit Doors: 2'-8" Water Closets: 0 0 0 �'I LLLLLU - 11RIGID INSULATION Minimum Number of Exits: Uj Lavatories: 0 0 0 Drinking Fountains: 0 0 0 BRICK & MASONRY o Occupant load ;,,50 , Z METAL , oc.io�zo E.I.F.S. SYSTEM fra r��'�ga 5:... �,.r skr•ir. = 2 ExitSr Req'd CONTINUOUS ee NON-CONTINOUS WOOD Q Minimum Egress Width Required [Total] PROVIDED NEW; MALE: FEMALE: UNISEX: CO 0 0- Egress Width = .3" x Occupant LoadUrinals: o 5 0 0 Cn Cl) r =.3" x 308 Water Closets: 1 4 0` _o v = 92;4" > minimum of 36" <w Lavatories: 2 2 0 ti CL Stairway Width = .3" x Occupant Load Drinking' Fountains: 0 0 0 C!:) cn CU 06 Q x308 _� L H = 92A"> minimum of 36" TOTAL FIXTURE COUNT: Minimum Egress Width Provided [Total] MALE: FEMALE: UNISEX: ca _ O Existing Stairway Width = 48" Clear Width Provided Urinals: 5 0 0 Water Closets: 1 4 0 New Exterior Stair Width = 48" Clear Width Provided Lavatories: 2 2 0 V Total Egress Stair Width = 96" Clear Width of. Egress Drinking Fountains: 0 0 0 H Z W U O D D W W Material Symbols CONCRETE' o CONCRETE (SECTe STEEL BATT INSULATION E75 EARTH FILL GYPSUM ;•,., ACOUSTICAL CEILING TILEum�muum�u� V) BUILT UP ROOFING C1 eee •� CE MIC TILE �'I LLLLLU - 11RIGID INSULATION Uj STUCCO BRICK & MASONRY o CONCRETE BLOCK (CMU) Z METAL , oc.io�zo E.I.F.S. SYSTEM fra r��'�ga 5:... �,.r skr•ir. FACE BRICK CONTINUOUS ee NON-CONTINOUS WOOD Q BED OF APPLICANT: BARRY IVINS 401 UNIVERSITY DR. COLLEGE STATION, TX 77840 979.220.6966 OWNER: SHELTON FAMILY PARTNERSHIP 3501 GILLON AVE. DALLAS, TX 75205 F: 214.526.2366 ces o Cl) Z "gr RO E75 0' V) OM N C1 ,- ,;_ o LUCn � V- � � 0 Uj z o m�J Z oc.io�zo C z >t�0 0>m z J U Q 00 W CO 0 0- o _ ce Cn Cl) r z _o v d- � 00 <w 1- ti CL =:s � C!:) cn CU 06 Q _� L H C� E ca _ O C UJ CM c�fl► O V ces Cl) Z "gr RO t2 Y+ OM N -SRO 07 — — Z � V- � � 0 Uj LU CD LLj —1� m�J Z oc.io�zo co 0 >t�0 0>m Ll- W� V o>'> J z MO 00 W CO =W Cn o _ ce Cn 113 z `o z Q �o CL C0 48" WIDE STAIR EXIST "THE CORNER" BAR & GRILL SCALE: 1/4" = T-0" z w U 0 O NTRACT )OCUMENT! ,RRY IVINS 11 UNIVERSITY DI ILLEGE STATION, 77840 '9.220.6966 VNER: IELTON FAMILY ,RTNERSHIP 601 GILLONrAVE. ►LLAS, TX 75205 O 71 mnr\o DLuu - i nG vvnivcn Of Ijrxrn - H ROOM ROOM NAMEFIN FLOOR BASE NWALL E WALL S W. z LC NO O oZC cuz OPOSED ROOFTOP PATIO BAR30, Zai '- m z � W Q �.myyrrE -- PATIO AREA SR coNc NA -- -- -- -- 302 BAR SERVICE AREA CONC RES GBD PB -1 GBD PB -1 L GBD N 303 f00D PREP;KTTCHEN CONC >RES GBD PB -2 GBD PB -2 GBD I- 304 WOMENS RESTROOM SR CONC .CRTAGBBDD4Lt GBD CRT/P&_2 GBD 06 305 MENS RESTROOM SR CONC CRT GBD CRT PB -2 GBD 306 STORAGE AREA CONC RES GBD PB -2 ;GBD C13 E c G �..� 0 111 MATERIALS LEG �`.. FLOOR: BASE; WALLS: FINJ _ EL CRT= CERAMIC 11D MRB= 5 8 MOISTURE RESISTANT _ RES= RESIDENT GYPSUM BOARD , B-1=' SEMI GBD= °58 FC GYPSUM BOARD —2= SEMI-� — 'n MU= 'CONCRETE `MASONRY UNIT RT= CERAMIC L CONC= -SUP -RESISTANT CO = WALL. CA VWC= VIWL 'V z w U 0 O NTRACT )OCUMENT! ,RRY IVINS 11 UNIVERSITY DI ILLEGE STATION, 77840 '9.220.6966 VNER: IELTON FAMILY ,RTNERSHIP 601 GILLONrAVE. ►LLAS, TX 75205 .J O .00 to ri U-) W Of rn ♦/� !z W � N C z LC P. O oZC cuz Vo m Zai '- m z � W Q �.myyrrE 0 00 LLJ ui � CD N UJ a I- r � Q CJS c 06 O s fJ C13 E c G �..� 0 111 �`.. .J O c Z ca 1-- N s CO to 1-- � N C rno WcXL LC P. J!Gdcn- OUO0'W oZC n Vo m Zai '- m �o � W �5 �.myyrrE 00 LLJ CD m RAWING SHEET NUMBE 48" WIDE STAIR EXIST EXST GREASETRAP IST FLOOR LAY -IN CEILING SYSTEM -1 HOUR RATED "THE CORNER" BAR & GRILL - REF. CELING PLAN SCALE: 3/16" =1'-0" )E STAIR E F -----I "< 1" STUCCO FINISH OVER 1 /2" i y i DENSGLAS SHEATHING 'H I Re: 3/A1.2 L ----J LAY -IN CEILING SYSTEM -1 HOUR RATED — — — <� } -74 --- � SCALE: 3/16" =1'-0" METAL SHEET 6" BATT INSUALTION (IN PURLIN SP 3-s' METAL STUD 2' HAS T CHANNELS @ 16" O.C. T DENSGLAS SHEATHING 1"STUCCO FINISH W/ METAL LATH VENT TRIM BATT INSULATION THIN SET BRICK s' F.0 GYPSUM BOARD (PAI 3 "THE CORNER" BAR & GRILL - DETAIL SCALE: 3" =1'-0" STUCCO SOFFIT DETAIL T HVAC ALL WALLS IN OPEN ;EGRESS CORRIDOR AL2 HOUR FIRE WALL -------------I I mkvil 1 llll `L SCALE: 3" =1'-0" 3'-0" �--- 21.11 PROVIDE NEW INFILL w/ MATCHING FIRE RATING CV M SECOND FLOOR EXIT REDESIGN DEMO EXISTING WALL EXISTING W. NEW INFILL w/ OTCHING FIRE RATING UJI 0 w cn W w DRAWING TITLE RCP PLAN . & ROOF PLAN P5 2 UU") on w Uj �- J � O J 0 _ cnui H`— CONI-- O cm Q0� z WO N O IZ cz OC.aOwzO J z :> ■� z a '■L. owo = 0 LAY -IN CEILING SYSTEM -1 HOUR RATED — — — <� } -74 --- � SCALE: 3/16" =1'-0" METAL SHEET 6" BATT INSUALTION (IN PURLIN SP 3-s' METAL STUD 2' HAS T CHANNELS @ 16" O.C. T DENSGLAS SHEATHING 1"STUCCO FINISH W/ METAL LATH VENT TRIM BATT INSULATION THIN SET BRICK s' F.0 GYPSUM BOARD (PAI 3 "THE CORNER" BAR & GRILL - DETAIL SCALE: 3" =1'-0" STUCCO SOFFIT DETAIL T HVAC ALL WALLS IN OPEN ;EGRESS CORRIDOR AL2 HOUR FIRE WALL -------------I I mkvil 1 llll `L SCALE: 3" =1'-0" 3'-0" �--- 21.11 PROVIDE NEW INFILL w/ MATCHING FIRE RATING CV M SECOND FLOOR EXIT REDESIGN DEMO EXISTING WALL EXISTING W. NEW INFILL w/ OTCHING FIRE RATING UJI 0 w cn W w M OF u =-Aa7_u13 CONTRACT DOCUMENTS APPLICANT: BARRY IVINS 401 UNIVERSITY DR. COLLEGE STATION, TX 77640 979.220.6966 OWNER: SHELTON FAMILY PARTNERSHIP 3501 GILLON AVE. DALLAS, TX 75205 F: 21 4.526.2366 DRAWING TITLE RCP PLAN . & ROOF PLAN M OF u =-Aa7_u13 CONTRACT DOCUMENTS APPLICANT: BARRY IVINS 401 UNIVERSITY DR. COLLEGE STATION, TX 77640 979.220.6966 OWNER: SHELTON FAMILY PARTNERSHIP 3501 GILLON AVE. DALLAS, TX 75205 F: 21 4.526.2366 cn O � 0 C) . z C.D P5 2 UU") w Uj �- J � O J 0 _ cnui H`— CONI-- O cm Q0� z WO N O IZ cz OC.aOwzO J z :> ■� z a owo = 0 n � co m ��o (=l cn U) cn w >co �� co �� C-) cn C/:)ry D cu 06 Q :0. cu CD S� = ll� o caE �+ cc 0 �cn W N 1*- _ Oo � U cn U- CD o 0 a_ O M N J � O J 0 H`— CONI-- O cm Q0� �<1� V WO N C IZ OC.aOwzO J 0 :> o'" > J owo = w c � co m ��o U) uj m w >co �� >- �� m cn DRAWING SHEET NUMBER Al 2 1 SHEET 3 OF 8 EW METAL ROOFING • _ _'SET ------------------------ • ®. . s • -- ----------------- ----------------- ---------------- -- ____— _—---------------------------- _ Nj ___ CVIQTIAIP- OTAID T/WI= �1 "THE CORNER" BAR &GRILL - SCALE: 118" =1'-0" 1•t 2 "THE CORNER" BAR &GRILL -SECTION SCALE: 1/8" =1'-0" QTCCI DI IDI IAIQ Dn• QTDI IrTI IDAI AACTAI DnAMItl I AV_IAI r%Cll IAIf_' _ 4 4.ID DATM QVQTCRA 1" STUCCO SOFFIT Re: 31A1.2 OF 0 t- APPLICANT: r BARRY IVINS 401 UNIVERSITY DR. �+ COLLEGE STATION, co CO TX 77940 979.220.6966 OWNER: SHELTON FAMILY PARTNERSHIP 3BO1 GILLON AVE. DALLAS, TX 75205 F• 21 4.526.2366 F ti, r O ON O X 1� I- O (D cq Lu Ro OS C)N J ~ V- _ cLu QD z O V' NEW STEEL RE: STRUCTURAL cu z 0 LuN v CJS cn 06 <t cc 9' a< oF-- o ti� 0 0 1 1/2" SQUARE TUBE 3" X 3" METAL CAP WELDED IN PLACE U d'. 314" METAL PICKET @ 4.5" O.C. 2" SQUARE TUBE ;�® Z211 WELDED TO METAL PLATE BASEPLATE RE: STRUCTURAL � "THE CORNER" BAR &GRILL - RAIL DETAIL DRAWING SHEET NUMBER L_ ^� -1.2 - T CO WA\ \\V�V o ti� 0 0 1 1/2" SQUARE TUBE 3" X 3" METAL CAP WELDED IN PLACE U d'. 314" METAL PICKET @ 4.5" O.C. 2" SQUARE TUBE ;�® Z211 WELDED TO METAL PLATE BASEPLATE RE: STRUCTURAL � "THE CORNER" BAR &GRILL - RAIL DETAIL DRAWING SHEET NUMBER 48" WIDE STAIR EXIST "THE CORNER" BAR & GRILL - SCALE: 1/4" =1'-0" ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION FLOURESCENT TUBE DUPLEX RECEPTACLE GENERAL ELECTRICAL NOTES 1. ALL ELECTRICAL WORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE PREVAILING CODES. 2. ELECTRICAL CONTRACTOR SHALL FURNISH & INSTALL ALL WIRING; BOXES, CONDUITS, AND FIXTURES AS SHOWN ON THE PLANS. THIS INCLUDES ANY REQUIREII)TEMS`NOT SPECIFICALLY NOTED ON PLANS TO MAKE SYSTEMS OPERATIONAL AND MEET PREVAILING `CODES. 3. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR FOR HVAC UNIT REQUIREMENTS AND FOR ELECTRICAL REQUIREMENTS FOR RESTROOM.EXHAUST FANS. 4. THE ELECTRICAL CONTRACTOR SHALL VERIFY SIZES OF BREAKERS, FUSES, PANELS ETC. AND ADJUST IF REQUIRED TO MEET CODES OR TO PROVIDE ADEQUATE SERVICE, ELECTRICAL CONTRACTOR SHALL NOTIFY CONTRACTOR AND ARCHITECT OF ANY SUCH CHANGES. 5. ALL RESTROOM EXHAUST FANS SHALL BE SWITCHED WITH THE LIGHTS WHEN ACCEPTABLE TO CODES, 6. ELECTRICAL CONTRACTOR SHALL INSTALL PRIMARY CONDUIT FOR PHONE LINES AND DATA DROPS. CONDUITS SHALL BE SUPPLIED WITH PULL STRINGS FOR USE BY OTHERS. 7. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE ELECTRICAL SERVICE, DISCONNECT, SUB -FEED AND INTERIOR PANEL(S) AS REQUIRED. 8. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED PERMITS AND INSPECTIONS. 9. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL REQUIRED; EMERGENCY SIGNS WITH BATTERY BACK-UPS AS REQUIRED AND INDICATED ON PLANS. 10. ALL WIRING BE SIZED AS PER THE CURRENT VERSION OF THE NATIONAL ELECTRIC CODE REQUIREMENTS, 11. THE ELECTRICAL CONTRACTOR SHALL PROVIDE STANDARD INSTALLATION AND MANUFACTURER'S WARRANTY. 12. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL AND PLUMBING CONTRACTORS FOR PORTIONS' OF THE WORK AS REQUIRED. 13. ALL EQUIPMENT PROVIDED SHALL BE U.L. LISTED FOR FOR THE USE.INTENDED AND THE METHOD OF INSTALLATION, 14. ELECTRICAL CONTRACTOR SHALL FURNISH`REQUIRED INFORMATIOR SUCH AS LOAD SUMMARY, ONE LINES, OR RISER DIAGRAMS. THESE SHALL BE CALCULATED BY A MASTER ELECTRICIAN AND THEIR LICENSE NUMBER SHALL BE PROVIDED WITH SUCH CALCULATIONS AND INFORMATION. F, 05-29-08 CONTRACT DOCUMENTS APPLICANT: BARRY IVINS 401 UNIVERSITY DR. COLLEGE STATION, TX 77840 979.220.6966 OWNER: SHELTON FAMILY PARTNERSHIP 3501 GILLDN AVE. DALLAS, TX 75205 F: 214.526.2366 0 �orlLu ry LU co _o z r� M c' z 0 z z Q V♦ U -1 Lu 1 v � to CIOoes < >. 5� d ><cacn O co V5uu � � DUPLEX RECEPTACLE �f- ONS W/ GROUND FAULT INTERRUPTION STANDARD LIGHT FIXTURE DUPLEX - WEATHER PROOF SURFACE MOUNTED � 'QUAD RECEPTACLE ll -t�-- WALL MOUNTEDLIGHT _ � 220V ELECTRICAL OUTLET EDIT EXIT LIGHT TYPE DIRECTIONAL AS NOTED d) SINGLE 115V RECEPTACLE BRACKET MTD."FXT. TYPE Q SINGLE 115V RECEPTACLE UNSWITCHED FLORESCENT FXT 0 TELEPHONE/DATA OUTLET IN WALL " EMERGENCY FIXTURE TYPE ® TELEPHONE/DATA OUTLET IN FLOOR BOX PENDANT LIGHT FIXTURE a JUNCTION BOX [USE AS NOTED] RECESSED LIGHT FIXTURE Q SPEAKER [ 'LOCATED AS NOTED] SINGLE POLE SWITCH � VISUAL ALARM $'' THREE WAY SWITCH A'AUDIO VISUAL ALARM DIMMER SWITCH SMOKE DETECTOR am 120V PANEL THERMOSTAT am 480V PANEL CABLE OUTLET. FLOOD LIGHT FIXTURE _O A PHONE JACK L.� EXHAUST FAN ONLY 1 PHONE/DATA JACK(CAT 5 WIRING) ' ® COMBINATION LIGHT AND EXHAUST FAN CEILING FAN CEILING FAN W1 LIGHT KIT NOTE:: ALL `SYMBOLS MAY NOT BE USED ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION FLOURESCENT TUBE DUPLEX RECEPTACLE GENERAL ELECTRICAL NOTES 1. ALL ELECTRICAL WORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE PREVAILING CODES. 2. ELECTRICAL CONTRACTOR SHALL FURNISH & INSTALL ALL WIRING; BOXES, CONDUITS, AND FIXTURES AS SHOWN ON THE PLANS. THIS INCLUDES ANY REQUIREII)TEMS`NOT SPECIFICALLY NOTED ON PLANS TO MAKE SYSTEMS OPERATIONAL AND MEET PREVAILING `CODES. 3. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR FOR HVAC UNIT REQUIREMENTS AND FOR ELECTRICAL REQUIREMENTS FOR RESTROOM.EXHAUST FANS. 4. THE ELECTRICAL CONTRACTOR SHALL VERIFY SIZES OF BREAKERS, FUSES, PANELS ETC. AND ADJUST IF REQUIRED TO MEET CODES OR TO PROVIDE ADEQUATE SERVICE, ELECTRICAL CONTRACTOR SHALL NOTIFY CONTRACTOR AND ARCHITECT OF ANY SUCH CHANGES. 5. ALL RESTROOM EXHAUST FANS SHALL BE SWITCHED WITH THE LIGHTS WHEN ACCEPTABLE TO CODES, 6. ELECTRICAL CONTRACTOR SHALL INSTALL PRIMARY CONDUIT FOR PHONE LINES AND DATA DROPS. CONDUITS SHALL BE SUPPLIED WITH PULL STRINGS FOR USE BY OTHERS. 7. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE ELECTRICAL SERVICE, DISCONNECT, SUB -FEED AND INTERIOR PANEL(S) AS REQUIRED. 8. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED PERMITS AND INSPECTIONS. 9. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL REQUIRED; EMERGENCY SIGNS WITH BATTERY BACK-UPS AS REQUIRED AND INDICATED ON PLANS. 10. ALL WIRING BE SIZED AS PER THE CURRENT VERSION OF THE NATIONAL ELECTRIC CODE REQUIREMENTS, 11. THE ELECTRICAL CONTRACTOR SHALL PROVIDE STANDARD INSTALLATION AND MANUFACTURER'S WARRANTY. 12. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL AND PLUMBING CONTRACTORS FOR PORTIONS' OF THE WORK AS REQUIRED. 13. ALL EQUIPMENT PROVIDED SHALL BE U.L. LISTED FOR FOR THE USE.INTENDED AND THE METHOD OF INSTALLATION, 14. ELECTRICAL CONTRACTOR SHALL FURNISH`REQUIRED INFORMATIOR SUCH AS LOAD SUMMARY, ONE LINES, OR RISER DIAGRAMS. THESE SHALL BE CALCULATED BY A MASTER ELECTRICIAN AND THEIR LICENSE NUMBER SHALL BE PROVIDED WITH SUCH CALCULATIONS AND INFORMATION. F, 05-29-08 CONTRACT DOCUMENTS APPLICANT: BARRY IVINS 401 UNIVERSITY DR. COLLEGE STATION, TX 77840 979.220.6966 OWNER: SHELTON FAMILY PARTNERSHIP 3501 GILLDN AVE. DALLAS, TX 75205 F: 214.526.2366 0 �orlLu ry LU co _o z r� M c' z 0 z z Q V♦ U -1 Lu 1 v � to CIOoes < >. 5� d ><cacn O co V5uu O �f- ONS N Z Q OUOW ZO � w Q Oui m � �m Q O o Urc _O OOry ad C/) `r � �o -°a rn z U) Q J CC") nj CI fl% Uj Lu Cl Co O �f- ONS N Z Q OUOW ZO � w Q Oui m � �m Q O o Urc 70 O �f- ONS N Z Q OUOW ZO � w Q Oui m � �m Q �o DRAWING SHEET NUMBER SHEET 6 OF 48" WIDE STAIR EXIST "THE CORNER" BAR &GRILL - EL SCALE: 1/4" =1'-0" ELECTRICAL LEGEND SYMBOL .DESCRIPTION SYMBOL DESCRIPTION Z FLOURESCENT TUBE � DUPLEX RECEPTACLE � DUPLEX RECEPTACLE CD O\ J W/ GROUND FAULT INTERRUPTION STANDARD LIGHT FIXTURE � DUPLEX - WEATHER PROOF SURFACE MOUNTED � ` QUAD RECEPTACLE -(I}- - WALL MOUNTED LIGHT C 220V ELECTRICAL OUTLET SIT EXIT LIGHT TYPE z ■� DIRECTIONAL AS NOTED � SINGLE 115V RECEPTACLE BRACKET MTD: FXT. TYPE V SINGLE 115V RECEPTACLE UNSWITCHED `FLORESCENT FXT TELEPHONE/DATA OUTLET IN WALL �P EMERGENCY FIXTURE TYPE � TELEPHONE/DATA OUTLET IN FLOOR BOX PENDANT LIGHT FIXTURE a JUNCTION BOX [USE AS NOTED] RECESSED LIGHT FIXTURE a SPEAKER [ LOCATED AS NOTED] $ SINGLE POLE SWITCH � VISUAL ALARM $' THREE WAY SWITCH t� AUDIO VISUAL ALARM. DIMMER SWITCH ® SMOKE DETECTOR E c 120V PANEL � THERMOSTAT ■ o 480V PANEL a N CABLE OUTLET FLOOD LIGHT FIXTURE Z o a PHONE JACK - EXHAUST FAN"ONLY 1 PHONE/DATA JACK (CAT 5 WIRING) COMBINATION' LIGHT AND EXHAUST FAN ..CEILING -FAN CEILING FAN W/ LIGHT KIT NOTE: ALL SYMBOLS MAY NOT: BE USED 3ENERAL ELECTRICAL NOTES . A 125v singe phase 20 amp -rated receptacle outlet shall be installed at an accessible Dcation for the servicing of heating, air conditioning, and refrigeration equipment on all ooftops, attics, crawl spaces, and outside equipment locations. The receptacle outlet is - equired to be installed within 10!4' of the equipment to be serviced. The receptacle shall rot be connected to the load side of the equipment disconnecting means. ?. Conductor material for general wiring shall be copper. Aluminum conductors sized 1/ 0 or arger may be used outside of a building or structure. 3. Riser Diagrams and Electrical Load calculations shall be provided by the electrical �ntractor or owner prior to permitting. GENERAL ELECTRICAL NOTES 1. ALLELECTRICAL WORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE PREVAILING CODES, 2. ELECTRICAL CONTRACTOR SHALL FURNISH & INSTALL ALL WIRING, BOXES, CONDUITS, AND FIXTURES AS SHOWN ON THE PLANS, THIS INCLUDES ANY REQUIRED ITEMS NOT SPECIFICALLY NOTED ON PLANS TO MAKE SYSTEMS OPERATIONAL AND MEET PREVAILINUODES 3. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL: CONTRACTOR FOR HVAC UNIT REQUIREMENTS AND FOR ELECTRICAL REQUIREMENTS FOR RESTROOM EXHAUST FANS, 4. THE ELECTRICAL CONTRACTOR SHALL VERIFY SIZES OF BREAKERS, FUSES, PANELS ETC. AND ADJUST IF REQUIRED TO MEET CODES OR TO PROVIDE ADEQUATE SERVICE. ELECTRICAL CONTRACTOR SHALL NOTIFY CONTRACTOR AND ARCHITECT OF ANY SUCH CHANGES. 5. ALL RESTROOM EXHAUST FANS SHALL BE SWITCHED WITH THE LIGHTS WHEN ACCEPTABLE TO CODES. 6. ELECTRICAL CONTRACTOR SHALL INSTALL PRIMARY CONDUIT FOR PHONE LINES AND DATA DROPS. CONDUITS SHALL BE SUPPLIED WITH PULL STRINGS FOR USE BY OTHERS. 7. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE ELECTRICAL SERVICE, DISCONNECT, SUB -FEED AND INTERIOR PANEL(S) AS REQUIRED. I 8. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED PERMITS AND INSPECTIONS. 9. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL REQUIRED EMERGENCY SIGNS WITH BATTERY BACK-UPS AS REQUIRED AND INDICATED ON PLANS. 10. ALL WIRING SHALL BE SIZED AS PER THE CURRENT VERSION OF THE NATIONAL ELECTRIC CODE REQUIREMENTS. 11. THE ELECTRICAL CONTRACTOR SHALL PROVIDE STANDARD INSTALLATION AND MANUFACTURERS WARRANTY. 12. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL AND PLUMBING CONTRACTORS FOR PORTIONS OF THE WORK AS REQUIRED, 13. ALL EQUIPMENT PROVIDED SHALL BE U.L. LISTED FOR FOR THE USE INTENDED AND THE METHOD OF INSTALLATION, 14. ELECTRICAL CONTRACTOR SHALL FURNISH REQUIRED INFORMATION SUCH AS LOAD SUMMARY, ONE LINES, OR RISER DIAGRAMS. THESE SHALL BE CALCULATED BY A MASTER ELECTRICIAN AND THEIR LICENSE NUMBER SHALL BE PROVIDED WITH SUCH CALCULATIONS AND INFORMATION. 05-29-08 CONTRACT DOCUMENTS APPLICANT: BARRY IVINS 401 UNIVERSITY DR. COLLEGE STATION, TX 77840 979.220.6966 OWNER: SHELTON FAMILY PARTNERSHIP, 3501 GILLON AVE. DALLAS, TX 75205 F: 214.S26.2366 PROJECT TITLE & DESCRIPTION CJS `_ �o Z ti� '0 �. C OM JAZ z C1, o Q 0 WO ��C0 «s C!) _j ��CD W N LU z / V G u- Uj CI 0 U m 00 Uj M W co o ~__ cn v9 UjUj m �w z� z m Cl) PROJECT TITLE & DESCRIPTION DRAWING SHEET NUMBER E 1 ILL2` 'SHEET 7 OF S Z � ■ Z V� W ,0 0 Q ��LU CD O\ J IY Cn Z 0 C L9 z z ■� z V LLJti 06 0 0 .}.r E c cn C/? ■ o a N Z o a r--- U PROJECT TITLE & DESCRIPTION CJS `_ �o Z ti� '0 �. C OM JAZ z C1, o Q 0 WO ��C0 «s C!) _j ��CD W N LU z / V G u- Uj CI 0 U m 00 Uj M W co o ~__ cn v9 UjUj m �w z� z m Cl) PROJECT TITLE & DESCRIPTION DRAWING SHEET NUMBER E 1 ILL2` 'SHEET 7 OF S GENERAL NOTES FOR REINFORCEMENT THE FOLLOWING MINIMUM CONCRETE COVER SHALL I 1. THE STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE, 2003 EDITION (IBC). 2. THE DESIGN GRAVITY LOADS CAST IN-PLACE CONCRETE CONSTRUCTION: e-, _A p ARE AS FOLLOWS: DEAD LOADS INCLUDE MATERIAL WEIGHTS WITH A 4 PSF MECHANICAL SURCHARGE LOAD AND 20 PSF PARTITION PERMANENTLY EXPOSED To EARTH ...... .......... THOMAS E. C;ESSNER......................... LOAD LIVE. LOADS 0 90967 ROOF 10 PSF SPACE 100 PSF NO.'6 THRU NO. 18 BARS <"COMMERCIAL Ss/0NAL EAG 3. EXCEPT FOR LOADS EQUAL TO OR IN EXCESS OF 100 PSF, LIVE LOADS ARE REDUCED ACCORDING TO, SECTION 1607.9 1.5 INCHES AA OF THE IBC. 4. THE STRUCTURE �HAS BEEN DESIGNED TO WITH WIND PRESSURE BASED ON A 100 MILE PER HOUR WIND SPEED. WEATHER OR IN CONTACT WITH < WIND PRESSURES WERE - CALCULATED FROM ASCE 7, AS ALLOWED IN SECTION 1609.1.1 OF :5; SLABS, WALLS, JOISTS THE IBC. No. 14 1& NO. 18 BARS NO 11 EARS & SMALLER 1.5 INCHES S. STRUCTURAL DRAWINGS SHALL BE COORDINATED WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. VERIFY ALL DIMENSIONS WITH FOR CONSTRUCTI O ARCHITECTURAL DRAWINGS. 6. THIS DESIGN IS BASED ON THE PREPARED ARCHITECTURAL 113 6- I O..oa DRAWINGS, WHERE CONDITIONS OTHER THAN THOSE SHOWN ON ARCHITECTURAL D DRAWINGS EXIST, THE CONTRACTOR SHALL CONTACT GESSNER 1.5 INCHES ENGINEERING TO ADDRESS THOSE DIFFERENCES. BARS IN A LAYER SHALL BE T HE DIAMETER OF THE GENERAL FOUNDATION NOTES NOMINAL MAXIMUM SIZE OF COARSE AGGREGATE I. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF A. 1/5 THE NARROWEST DIMENSION BETWEEN SIDES 4000 PSI AT 28 DAYS AND SHALL HAVE AN APPROVED AIR B. 1/3 THE DEPTH OF SLABS, NOR ENTRAINMENT AGENT. FLY ASH MAY BE CONSIDERED AT THE INDIVIDUAL REINFORCING BARS. DISCRETION OF THE ENGINEER IF AMBIENT TEMPERATURE AT THE 979-680.8841 (Fax) vMw.gessnerengineedng.com TIME OF POUR ARE EXPECTED To bE IN EXCESS OF 70 DEGRESS A A TIE TO EXISTING FAHRENHEIT. C) FOR 2. ALL REINFORCEMENT SHALL B I E ASTM A-615, GRADE 60. THE CO ____-_DOWNSPOUT ROOF DRAINAGESLAB SHALL BE REINFORCED WITH #3 BARS @ 12- OCEW. 3. ALL SLAB REINFORCEMENT SHALL BE SUPPORTED WITH CHAIRS < OR MASONRY BRIQUETTES- AT NOT MORE THAN 6 FEET ON CENTER. 4. REINFORCING BARS WILL BESEbURED AT EVERY OTHER INTERSECTION. PROJECT TITLE &DESCRIPTION 7. LAPS AND SPLICES IN REINFORCING BARS WILL BE A MINIMUM OF S1.1 30 BAR. DIAMETERS. 0 8. STRUCTURAL DRAWINGS TO BE: COORDINATED W/ ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR Z ALL OPENINGS, INSERTS, AND RELATED ITEMS. SHEET 1 OF 4 9. ALL FOUNDATION PLAN DIMENSIONS ARE INTERPRETED FROM AND SHALL BE VERIFIED WITH THE FLOOR PLAN AND THE OWNER NOTIFEEDlF DISCREPANCIES EXIST. 10. ANY UNUSUAL CONDITIONS ENCOUNTERED AFFECTING THE FOUNDATION SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER AND THE ENGINEER PRIOR TO CONCRETE PLACEMENT. 11. BASED ON IBC 2000 PROVISIONS, SECTIONS 7.2 & 7.3, ALL BARS SHALL BE COLD BENT WITH XMINIMUM INTERNAL BEND RADIUS OF 6 BAR DIAMETERS EXCEPT STIRRUPS AND TIES, WHICH SHALL BE GREATER THAN 4 BAR DIAMETER'S IN REGARD U) TO INTERNAL BEND rnM RADII. BENDING SHALL NOT BE DONE IN FIELD U.N.O. < m cn F- F - 0 cu p CONCRETE PROTECTION FOR REINFORCEMENT THE FOLLOWING MINIMUM CONCRETE COVER SHALL I BE PROVIDED FOR REINFORCEMENT FOR CAST IN-PLACE CONCRETE CONSTRUCTION: CONCRETE CAST AGAINST AND C) PERMANENTLY EXPOSED To EARTH 3 INCHES CONCRETE EXPOSED TO EARTH OR WEATHER. cu NO.'6 THRU NO. 18 BARS 2 INCHES NO 5 BARS L & SMALLER 1.5 INCHES CONCRETE NOT EXPOSED TO W CU WEATHER OR IN CONTACT WITH < GROUND: :5; SLABS, WALLS, JOISTS No. 14 1& NO. 18 BARS NO 11 EARS & SMALLER 1.5 INCHES ������� 0.75 INCHES BEAM, COLUMNS: PRIMARY. REINFORCEMENT, TIES, D STIRRUPS, : SPIRALS 1.5 INCHES THE MONIMUM CLEAR SPACING BETWEEN PARALLEL , BARS IN A LAYER SHALL BE T HE DIAMETER OF THE BAR, BUT NOT LESS THAN ONE (1) INCH. NOMINAL MAXIMUM SIZE OF COARSE AGGREGATE SHALL NOT BE LARGER THAN: A. 1/5 THE NARROWEST DIMENSION BETWEEN SIDES OF FORMS, NOR B. 1/3 THE DEPTH OF SLABS, NOR C. 3/4 THE MINIMUM CLEAR SPACING BETWEEN INDIVIDUAL REINFORCING BARS. 0: U-: W co LII LO C) L0 00 cn cu 0 < (D W CU < :5; X cu ������� 'CL D C 0 Engineer ng. MEMO BY., CONTRACT ELI DATE: 06-10-08 E c U REVISIONS 1712 Southwest pky, Ste 105 College station, Texas 77840 A A C/) A 979-680.8841 (Fax) vMw.gessnerengineedng.com 0 --j A A C) A CO (D < DRAWING SHEET NUMBER PROJECT TITLE &DESCRIPTION S1.1 0 Z Z SHEET 1 OF 4 o- Q < m cn F- F - p 0: U-: W co LII L0 F- 0 0 < PROJECT TITL �&DESCP�J"ON PROJECT NO. 06-01 --Q6_35 ������� DRAWN BY: -TLC Engineer ng. MEMO BY., CONTRACT ELI DATE: 06-10-08 REVISIONS 1712 Southwest pky, Ste 105 College station, Texas 77840 A A P.O. Box 10763, 77842-0763 979-680.8840 (Phone) A 979-680.8841 (Fax) vMw.gessnerengineedng.com A A A DRAWING TITLE DRAWING SHEET NUMBER ROOF DECK S1.1 PLAN SHEET 1 OF 4 96 1 REF: 7�1 JIS 1. 1 o� to CD .'I FtS1.1 6 D/S1.1 2" 36'-I04' EXISTING L4x4xY4 DECK CLOSEOUT W 18x46 4" LIGHT WEIGHT CONCRETE DECKING 3/16 1.5C22 METAL DECK T STAIRWAY Eco (6)-/4" A307 RODS W/ 6" EMBED, USE SIMPSON SET EPDXY AC -4 REF: L5X -4" CL 00 G /E/S1.1 SIM 32LH 12 JOIST C ri U J\ - 2" GROUT BELOW BEAM @ 48 W10x2PROVIDE CONSISTENT '9 C14 S1.1 BEARING F --j "LIP STEEL TO CLIP STEEL TO F 711111I® mmmmp --Z-- Z /� Z - EXISTIN'3 COLUMNS, ROOF - TYP. ACCESS EXISTING ROOF STRUCTURE PANEL I 11- jLL WIN L THOMAS E. GESSNER 90967 /OMAI L2x2xY4 - 4" CLIP @ 2- C -C SPACING Y4" A307 RODS W/ 6" EMBED, USE SIMPSON SET EPDXY @ 48- C -C 1" GROUT. BELOW BEAM TO PROVIDE CONSISTENT BEARING L4x4x/V4 DECK CLOSEOUT Was 318" -1.5C22..METAL, DECK W I Ox22 %"A307 RODS W/6" EMBED, .USE SIMPSON SET EPDXY @ 48" C -C 32LH12 JOIST t--% A Oil W A307 RODS W/6". EMBED, USE SIMPSON ZET EPDXY @ 48' C -C t-1 AV moirte Fj F� F7 8 IT PLATE WELDED. TO EACH FACE -A 6"x6 � 36 PLATE 7 7 7 _7_7 7o L5x5x3/8 W/ 4 3/4 A307 BOLTS W 18x46 cr) 18x46 En 1w neering 1712 Southwest Pky, Ste 105 College Station, Texas 77840 P.O. Box 10763, 77842-0763.A 979.680.8840 (Phone) 979.680.8841 Fax www.gessnerengineedng.com CHECKED BY: TES CONTRACT ISSUE DATE. os -10 -Of REVISIONS A A DRAWING SHEET NUMBER S1,2 SHEET 2 OF 4 �E OF TF yqP �x9s *. 1.b THOMAS GESSNER q' 90967 '.. !PENSaC'`2�v A U 0 Z z 0 0 co _. cn cn cf)N 3a Ujz Q W p � CJ LL � W W czO J O U � 00 C ti toC, cn cc ._ GessnerCHECKED PROJECT NO. DRAWN BY: C= -> QD En 'neer'n BY. CONTRACT ISSUE DATE: ca os -10-o8 06 CL o 1712 Southwest Pky, Ste 105 College Station, Texas 77840 0' Q .L tUcu P.O. Box 10763, 77842-0763 979.680.8840 (Phone) Q Q W a 979.680.8841 (Fax) www.gessnerengineedng.com oCD L M O Q c U 0 Z z 0 0 _. cn m Ujz W p 'z LL O W W J O O PROJECT TITLE & DESCRIPTION GessnerCHECKED PROJECT NO. DRAWN BY: 06-0135 Tt_c En 'neer'n BY. CONTRACT ISSUE DATE: TEG os -10-o8 REVISIONS 1712 Southwest Pky, Ste 105 College Station, Texas 77840 0' Q P.O. Box 10763, 77842-0763 979.680.8840 (Phone) Q Q 979.680.8841 (Fax) www.gessnerengineedng.com Q DRAWING TITLE DRAWING SHEET NUMBER BUILDING FRAMING� S , 3 PLAN SHEET 3 OF 4 NG I I v/'11_ V V r"%L-I- f/ \I V GI- V V I I rl A WIND BRACING (SHEAR WALL NTS SOLID BLOCKING: _LOCATE BLOCKING AT EACH END OF WALL, ADJACENT TO OPENINGS, AND AS REQ'D. -FOR TRACK: WHERE BLOCKING MATERIAL THICKNESS ALLOWS, NOTCH AND BEND FLANGES 90 OR NCHOR TO VERTICALS W CLIP ANGLES. , 0 / 'FLAT STRAPS, NOTCHED CHANNEL, X -IDG BRIDG IN O BRR PROPRIETARY ING EACH SIDE IC LAP SP LIC � STRAPS MINIMUM M M 4 (102rnm). SCREWS AS REQ'D. (EACH SIDE) E WALL BRIDGING DETAIL NTs STRUCTURAL/MISCELANEOUS LIGHT GAUGE STEEL NOTES STEEL NOTES 1. THE COLD -FORMED STRUCTURAL FRAMING SHALL BE 1. ALL GROUT USED UNDER STEEL COLUMN BASE MANUFACTURED FROM STRUCTURAL QUALITY STEEL HAVING , PLATES SHALL'BE OF NON -SHRINKABLE TYPE AND MINIMUM YIELD STRENGTH OF 33 KSI (230 MPA) FOR ALL GAUGES *:: b•...':*.. C 8x1 1.5SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AND HAVE MINIMUM PROTECTION COATING EQUAL TO G-60 THOMAS E. GESSNER PURLINS' Ca? 4' OF 5000 PSI. GALVANIZED FINISH. THE STEEL SHALL CONFORM TO ONE OF THE :a :""""" " FOLLOW,� 90967 EF: G S5.1 C -C SPACING 2. ALL WELDING SHALL CONFORM TO THE 792 OR ASTM A 4 NG ASTM STANDARDS: ASTM A 653, ASTM A 875, ASTM A o,��s IiOEN?C�"- HSS 4x4xY8" STANDARDS OF CHAPTER J OF THE MANUAL OF S/ON L 6 C 8x1`1.5 B STEEL CONSTRUCTION OFTHE 2. STRUCTURAL FRAMING`SHALL BE PROPERLY SPACED, PLUMBED, A BEAM HE AMERICAN p, , LEVELED SQUARED, FIT U PROPERLY AGAINST ABUTTING MEMBERS 2 16 GA. FLA: _ P RL(N T INSTITUTE; OF STEEL CONSTRUCTION. SHORT AND HELD SECURELY IN PLA E C UNTIL PERMANENTLY F STRAP STABILITY FASTENED. V A ILITY CI _ RCUIT TRANSFER F ORT HE GAS METAL ARC TYING OF: WELDING PRO WIRE STRUCTURAL FRAMING COMPONENTS IS BRACING. CESS ISNOT PERMITTED. 00 - BRIDGING T125 54 PERMITTED. 400 T-125. 5 3. ELECTRODES FOR ALL FIELD AND 4 SHOP WELDING BRIDGING 3. FASTENING OF THE COLD -FORMED STRUCTURAL FRAMING SYSTEM SEE E S5.1 SHALL BE CLASSE7 OXX. SHALL BE.ACCO LI MP SHED BY SCREWING POWER ACTUATED „ SEE E '_S5.1 , FOR 3 4. ALL RECTANGULAR HSS F 46 KSI- SHAPES SHALL _lZ1x5 EMBED (Y / B i� FASTENERS, 4 ASTE ERS WELDING OR A COMBINATION 4 _ ON OF METHODS. THE EPDXIED SCREW STRAP TO CONFORM M TO ASTM A500 GRADE B. ALL OTHER CONSTRU GT for ANCHOR .TYPE :SIZE AND SPACING OF THE F T AS ENERS SHALL BE EACH _ CHS UD T SHAPES &PLATES A 3s. 06 � O o8 RE UIRED: BY THE CONTRACT D BOLTS' W! L4X4X Q DOCUMENTS OR APPROVED 5. ALL STRUCTURAL STEEL DETAILS -AND CONNECTION DETAILS: STIFFENER' AS 400S13Z-54 , CONNECTIONS H _ OSS ALL CONFORM TO STANDARDS 400S137 5 4 4. STRUCTURAL TRUC L FRAMINGTHAT HAS A PROTECTIVE COATI SHOWN _ ;, NG » STUD 6 1 OF THE RISC. REMOVED: BY WELDING SHA :STUD (91 G LL HAVE THE COATING REPAIRED AT 24 - 6. ALL MISCELLANEOUS C C SPACING US WELDS FIELD OR SHOP � _ ( ) THE WELDS BY PAINTING WITH A ZINC RICH PRIMER. _ C C SPACING R 400 T12 SHALL B 5 54 E MINIMUM SIZE FILLET ALL AROUND IN __ 5 - .400 ; - .COLD FORMED STRUCTURAL FRAMING MAY BE SHOP OR FIELD T125 54 ACCORDANCE W BOTTOM TRACK R NCE ITH RISC. WELDING OF FABRICATED INTO ASSEMBLIES PRIOR TO ERECTION OR STICK CONTINUOUS MEMBERS SHALL BEA MINIMUM OF .BUILT IN THE FIELD. 2 INCHES OF 3/161N CH FILLET STITCH`WEL SCREWS OR WELD..' WELDS AT 12 < 6. THE STRUCTURAL FRAMING D00 R OPENING S NG SHALL HAVE ENDS SQUARELY CUT BY INCHES 0: A S C STAGGERED EACH SIDE, ASR SHEARING OR SAWING BE INSTALLED PLUMB SQUARE,TRUE T EQ D WL O L FRAMI NG ELEVATION OT , HERWISE NOTED. COLUMN PLATES; CAP LINE AND SECURELY FASTENED PER THE CONTRACT D @)N-TSt OCUMENTS PLA AND ND STIFFENER PLATES SHALL BE' OR APPROVED CONNECTION DETAILS. TORCH' CUTTING IS NOT . WELDED ALL AROUND.„ PERMITTED. =Do OR HEADER ER FRAMIN AGON L G ELEVATION A BRACING DE G TAI L 7. PROVIDE ALL NECESSARY Y HOLES IN 7. FABRICATION, HANDLING, AND ERECTION OF THE STRUCTURAL S `'' -NTS MISCELLANEOUS STRUCTURAL STEEL MEMBERS FRAMING AND ASSEMBLIES SHALL BE DONE IN A MANNER TO FOR ATTACHMENT A CHM T OF NON-STRUCTURAL ITEMS PREVENT ANYbAMAGE'OR DISTORTION OF THE FRAMING. ( E.. HOLES FOR WINDOW HEAD ANCHORS 8. COLD FORMED TRACKS WHEN SET TO ADJACENT STRUCTURES, ,.: � _ 8. SPLICING STRUCTURAL STEEL MEMBERS SHALL HAVE WEB CONTACT WITH A UNIFORM AND LEVEL 'BEARING WHERE NOT DETAILED . IS PROHIBITED WITHOUT - SURFACE AND BE SECURELY ANCHORED WITH FASTENERS SIZED PRIOR APPROVAL O THE THE STRUCTURAL AND SPACED PER THE CONTRACT'DOCUMENTS OR APPROVED ENGINEER. CONNECTION DETAILS. 2.5x2.5XY A36 4 9. COORDINATE ALL STRUCTURAL DRAWINGS WITH.. 9. BRACING OF AXIAL LOADED STRUCTURAL FRAMING SHALL B _ E CAP PLATE ARCHITECTURAL DRAWINGS PR ACCOMPLISHED BY EITHER PRIOR TO , E COLD ROLLED CHANNEL, RUN CONSTRUCTION: HORIZONTALLY ■ .HSS 2.5x2,5xY THROUGH THE STUD AND ATTACHED- AT EACH STUD OR BY MINIMUM _ . U 2 WIDE STEEL STRAPS RUN HSS 1.5x1.5xY s HORIZONTALLY, ON BOTH SIDES OF THE STUDS, AND ATTACHED AT � .�. TOP TRACK 1�- EACH STUD. VERTICAL SPACING OF THE BRACING 1S LIMITED TO A , e-- MAXIMUM OF 4'-0", THROUGHOUT THE HEIGHT OF THE FRAMING 10. AXIAL LOADED STUDS ARE NOT PERMITTED TO HAVE ._ M SPLICES OR � I CUTOUTS. N THE FLANGES. AXIALLY OA M 3 3 LOADED STUDS SHA x _PICKET TY LL BE 550 S162 SECTION `OF TRACK -43 INSTALLED PLUMBED ALIGNED AND SECURED TO THE TOP AND V HEADER'BEAM' I BOTTOM TRACKS (WITHIN 1/16 OF THE TRACK WEB). en 11. .FRAMING OF WALL OPENINGS SHALL INCLUDE JACK STUDS, L � 0 HEADERS 'CRIPPLES SILL PLATES AND JAMB STUDS AS'PER THE O ti 3/16:CONTRACT DOCUMENTS OR APPROVED SHOP DRAWINGS. -s. C37 c _ SECTION OF STUD 12. FOR WALL FRAMING ASSEMBLIES THAT WILL FORM VOIDS WHICH ,� -Ir MSS 2x2`Iq' WILL NOT BE ACCESSIBLE TO THE INSULATION CONTRACTOR THE XY8 CRIPPLE STUD S FRAMING CONTRACTOR `Ot K M TRAC OR SHALL BE RESPONSIBLE FOR FILING V KICKER THE VOIDS, WITH SUITABLE INSULATION, PRIOR A HSS 2x2 ( , ASSEMBLY. O� XY SCREWS OR WELD13. SLIP CONNECTIONS ALLOWING FOR VERTICAL MOVEMENT OF -THE OR CTURE W � ST U ITHOUT IMPOSING VERTICAL -.LOAD ON THEHEAD TRACK AS REQ D c J Cu STRUCTURAL FRAMING SHALL'BE PER THE CONTRACTDOCUMENTS OR APPROVED. SHOP DRAWINGS. �.TEMPORARY BRACING OF TH CUNE STRUCTURA �L FRAMING S HALL BE „ PROVIDED AS REQUIRED AN Q D REMOVED ONLY 6x A36 2 fdx2.5 EA Y AFTER THE Zxa CON H DED FRAMING HAS BEEN SECURED WITH PERMANENT SUPPORT. - BASE PLATE CONCRETEANCHOR MULTIPLE MEMBERS 15. STRUCTURAL FRAMING SHEAR WALLS SHALL BE BUILT PER THE 06 ' SIDE VIEW AS REQUIRED C1'3 ., ELEVATION CONTRACT DOCUMENTS OR APPROVED SHOP DRAWINGS. 16. THE FLOOR OR ROOF FRAMING MEMBERS SHALL BE'LINED UP O DIRECTLY OVER VERTICAL SUPPORTS OR BELSUPPORTED BY •. -- X_ A S� BEAM HEADER AT OPENINGS LOAD DISTRIBUTION MEMBER PER THE CONTRACTDOC _. _ DOCUMENTS N E @PNT� WALL BRID OR APPROVED SHOPDRAWIN GING DETAIL GS. THE TOP. TRACK IS NOT F -NTS PERMITTED TO ACT AS A DISTRIBUTION MEMBER UNLESS C%) -Ir DESIGNED FOR THAT CONDITION. 17. COLD -FORMED V D D STRUCTURAL JOISTS SHALL BE SUPPORTED BY CLi J -I-+ FOUNDATION WALLS, JOIST HANGERS, LOAD DISTRIBUTION •- OO Q) MEMBERS, OR LINED UP, OVER VERTICAL SUPPORTS PER THE i _ CONTRACT DOCUMENTS O AP V O R PROVED SHOP DRAWINGS. M 18. COLD -FORMED STRUCTURAL JOISTS SHALL MINI - '' MUM 1 1/2 Q M U BEARING SUPPORT, A MINIMUM 10" OF UNPUNCHED WEB FROM AN END SUPPORT AND:MINIMU M 10 OF UNPUNCHED WEB ON SIDE OF AN INSIDE SUPPORT. PROJECT TITLE &DESCRIPTION 9. STRUCTURAL FRAMING WEB STIFFENERS SHALL BE LOCATED AND INSTALLED PER THE CONTRACT DOCUMENTSORAPPROVED SHOP DRAWINGS. 20. PROVIDE ADDITIONAL JOISTS .UNDER PARALLEL PARTITIONS WHERE THE PARTITION _ .TON LENGTH EXCEEDS ONE-HALF THE LENGTH OF THE JOIST SPAN. 21. PR .' DE OVI ADDITIONAL JOISTS AROUND OPENINGS WHICH : EXCEED THE NORMAL SP ACING OF THE JOISTS UNLESS OTHERWISE O NOTED. ■� 22. PROVIDE END BLOCKING WHERE JOIST ENDS ARE NOT RESTRAINED AGAINST _ NST ROTATION. 23. cn 3 STRUCTURAL FRAMING TRUSSES AND RAFTERS MAY BE � Q .SHOP OR FIELDAB FABRICATED INTO ASSEMBLIES' PRIOR m STICK BUILT IN THE FIELD. , _ TO ERECTION, OR w L H OW o z 1-- cn 0 cj)LL cn O w C'3 V Uj L1.1 J C) U� ` = V I- 0 O I PROJECT TITLE & DESCRIPTION PROJECT - N0. 06 0135 DRAWN BY: TLC erner , CHECKED BY. TES CONTRACT ISSUE DATE: - - . 06 10 08 Engineering REVISIONS 1712 Southwest P _ ky, Ste 105 College Station, Texas 77840 P.O. Box 10763 77842-0763 979.680.8840 (Phone) 979.680.8841.. (Fax) A www. essneren ineedn .Com 0 9 _9 g 0 DRAWING TITLE DRAWING SHEET NUMBER LIGHT GAUGE S5. 1 FRAM ING DETAILS 4 4 SHEET OF EXIST U) ��j j NEW HVAC UNIT 7 ON LOWER ROOF EQUI P M ENT SCHEDULE LU EXHAUST FANS @ 400 CFM �,�`' •':.► .•� J'�'•••..7 T£ ..... . Item o N m L w o No Qt Manufacturer Model` Number Equipment Cate o c2cn a o z ¢ > __ 1 1 Star Manufacturing 530M Fryer, Dee fat, Electric X 41.5 208 O _ _ 9 ry P_ 0 0 0 18 � 2 1 Star Manufacturing 530TD Fryer, _Deep Fat, Electric X 41.5 208 (� 3 1 Star Manufacturing ; 536CHSD Griddle, Electric X 43.9 208 = O 5 2'3 0 8 �I 4 CONTRACT Star Manufacturing 8136RC8 Broiler, Under. -Fired Gas 0.75. 120 4 i g /: UM'ENT D O C 5 1 Vulcan -Hart VG36 Range, Restaurant, Gas 0.75 120 , . X 5-15P 8.6 120 8 '' 1 True Food Service TSSU 48-12 - Refrigerator, Sandwich/Salad -Prep , Uj 5-15P ",4.2 11 p 7 1 Eagle Group/Metal Masters BW -2-120 Heat- Lamp/infrared Strip 120 19 5 8 1 APW Wyatt W -3V Wormer, Food, Electnc X 5-15P 10.0 120 ® a 0 - i ALD101D Oven ;Microwave X 5-15P' 13.2 120 ® 15 0 0 9 2 Amana ApPIlances` _ 5-15P 7.6 120 10 1 True Food Service T-23 Refrigerator, Reach in X 1s �§ _ , ~r HS -2 Sink, :Hand Wali Mount _ __ _: 11 1 Krawne Metal ■ 13 10 CF - 20 g„ CFM - 200 CFM 200 0 12 _ -In,X 5-15P 9.1 120 . • _355 0 12 1 True Food: Service T 49 Refrigerator; .:Reach . - .3' 120 208 13 1 ; True Food` Service T 49FG Display Case, Frozen 14-20P 12 / NA 14 1 Advance Taboo 4-3-54' Sink,; Economy 15 1 Scotsman G1030MR-32A Ice Maker w/o Sin X 15.8 208 APPLICANT: ® ® BARRY IVINS' • ® d 16 1 Scotsman 89485 Bin, Ice ■■ ■■■■■■ - .6 08 401 UNIVERSITY OF ■ 7 - 17 1 Scotsman ERC311 32A Icemaker Condenser. -Remote X 2 2 ® ® r u COLLEGE" STATION, - - !c 24400.0000 Iced Tea Brewer X 5-15P 15.0 120 r-�------------�------------ 18 1 Bunn 0 Mat TX 77840 1 10X AC UNIT 979.220.6966 --------------------------- - -- --- __, ,.___ _ _� 19 1 Captive lyre Exhaust Hood s -� O a --------------------- ------------------ ---- OWNER: SHELTON FAMILY PARTNERSHIP 3501 OILLQN AVE. DALLAS, TX 75205 F: 214.526.21366 EXHAUST HOOD RE: EQUIPMENT SCHEDULE SPLIT SYSTEM UNIT IN ATTIC .:..GENERAL HVAC NOTES n n ' p j 1. ALL HVAC WORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE PREVAILING CODES. MECHANICALLEGENDo �o z P5 THE CORNER MECHANICAL P �; C PLAN. 2. HVAC CONTRACTOR -SHALL FURNISH INSTALL ROOF TOP UNITS (RTU) AS SCHEDULED. SYMBOL DESCRIPTION - K, cn rn o, DIFFUSERS, GRILLS EQUIPMENT, 'AND:DEVICESASREQUIRED •� SCALE. 3/16"-1-0 3. HVAC CONTRACTOR SHALL FURNISH & IN ALL D SV w TIN SUPPLY AIR DIFFUSER CT FOR THE NEW SYSTEM PROPOSED ON THESE PLANS. THIS INCLUDES ANY REQUIRED ITEMS NOT SPECIFICALLY EXISTING E � NOTED ON PLANS 1 O IYIIIf�G S 1 S 1 GM OPERATIONAL., EXISTING RETURN AIR DIFFUSER aui i- Iv • K 4. HVAC CONTRACTOR SHALL FURNISH INSTALL R 8 RIGID FIBERGLASS DUCTWORK FOR ALL TRUNK _ D D 10 LU SQUARE TO ROUND DUCT TRANSITION NOTED. _ . BOARD ACCEPTABLE UNLESS O BOX LINES AS SHOWN C%.7 TIE TO EXISTING COLLECTION ''z 1 GREASE LINES TO DRAIN TO NEW GREASE - - NEW SUPPLY AIR DIFFUSER CONTRACTOR HALL FURNISH AND INSTALL GALV. SHEET METAL DROPS FROM RTU. DUCTS SHAL L BE N ENSURE 5. HVAC CONTRAC 0 S PROVIDE -AIR GAP,AND NS TRAP TRAP LOCATED ON FIRST FLOOR PRIOR TO AND DOWNSPOUT.o GREASETED W R INSULATION MINIMUM. 1EXTERNALLY INSULA l �•� OF SCUPPER R _ OPERATION . i CONTINUED_OP DIF ENEW RETURN AIR FUSER - ENTERING MA NSANITARY SEWER LINES. I z FLOOR _ 1 T L00 S DUCT W AN -B MINIMUM VALUE. LENGTH OF 1 � fl it 6. HVAC CONTRACTOR SHALL FURNISH & INSTALL ALL FLEXIBLE U WITH R � _ LO R OF LEVEL FOR WER 0 8 ROUND z L_ _______-___ � RUN SHALL NOT EXCEED 10.0 ,CONNECTIONS O F FLEX DUCT TO SHEET METAL SHALL E DONE USING RO � FLEX DUCT 0 Z INSERTS NYLON TIESTRAPS MADE' SPECIFICALLY FO R THAT PURPOSE. - a INE LOCKABLE DAMPER U -� 1116111 17 - TIE to � � 7. ALL BRANCH LINES SHALL BE FURNISHED WITH DAMPERS WITH LOCKING QUADRANTS. 8. HVAC CONTRACTOR SHALL SUPPORT ALL DUCTWORK FROM STRUCTURE. ALL HANGERS SHALL BE VERTICAL. NO O o LU o DUCTWORK SHALL LAY OR REST ON CEILINGS OR BE HUNG WITH WIRES. F� o FIRE DAMPER 8 ` T BACKS`OF ALL DIFFUSERS ARE INSULATED IN ACCORDANCE WITH F- N C � WH ` 9. HVAC SUBCONTRACTOR SHALL INSURE THA - vc I W H INTERNAL CLEAR DUCT DIMEN. Lu cu 4 PREVAILING CODES. / .�-• H h INCHES WIDTH(W)!.HEIGHT 10, WAC CONTRACTOR SHALL FURNISH AND INSTALL ONE EXHAUST FAN FOR EACH RESTROOM. 80cfrrr EXHAUST 4"� ' 112" � rJ � 2 X06 SHALL BE MINIMUM UNLESS NOTED. INSTALL AS PER MANR & PREVAILING CODE. FLAT R.D. " : �(" i • L HAVE ONE 7 DAY PROGRAMMABLE THERMOSTAT AS LOCATED PER PLANS OR AS BY NEW RECTANGULAR DUCT 06> 12 STRAINER 11. EACH HVAC UNIT SHALL O o � DECK LEVEL INSTALL a 11 p OWNER INSTRUCTIONS. ROUND DUCT INSIDE i DIAMETER AS SHOWN 1 fl 12. HVAC CONTRACTOR SHALL FURNISH & INSTALL ALL CONDENSATE PIPING PIPING SHALL BE ROUTED TO THE 12 19 1 5 Y PREVAILING ODE. INSULATE P -TRAP AND INITIAL 96 OF ._ 1 2 NEAREST TERMINATION POINT AS ALLOWED. B REV G C CAPPED DUCT CU -�. fl o 15 , � C 4 1 /o SLOPE O WITH PLUMBING CONTRACTOR, 4- f �,_____ � HORIZONTAL LINE. COORDINATE WORK -�-� " ® T „ C1 T THERMOSTAT C/� Ci 112 J �' 0 I � Q a A 13. HVAC CONTRACTOR SHALL ALL AND BALANCE SYSTEM PRIOR TO COMPLETION AND � � 16 p o F.D. F.D. W " 0 = n fl OCCUPANCY. TS REMOTE THERMOSTAT SENSOR C o !, 4 o fl p fl ®� „ zin. 1/2 14. HVAC CONTRACTOR SHALL PROVIDE STANDARD INSTALLATION AND MANUFACTURERS WARRANTY. _ 4 1% SLOPE ,_ 2 � fl 112 � �` A 6 c o f n n - �� O.5 ED WITH THE PLUMBING I AND ELECTRICAL NTRACTORS m J 112 112 15. HVAC CONTRACTOR SHALL COORDINATE AS REQUIRED U B NG CO s=suPPI Y TYPE CFM = �,. C r f�f�La�•r..LLL------------- --------•-•_•-•-•-•:.•-•-•-•�•-•- FORPORTIONS- OF THE WORK AS REQUIRED. E=EXHAUST q-......�., -�, R=RETURN ! __-- i_ f� �� / PRA.IFCT TITI F R nFRCRIPTIt1N