Loading...
HomeMy WebLinkAboutCorrespondences (:4- 3t LU- 1 "04 q 5A- 2551 Texas Ave. South, Ste. A, College Station, TX 77840 V 1)12-- ` ' ' Ofc: 979.693.5359 Fax: 979.693.4243 Email: mdgcstx @yahoo.com Web: lkitl J � OQ www.mdgcs.com 7 June 2004 Spencer Thompson City of College Station Development Services 1101 Texas Avenue South College Station, Texas 77842 Re: Williamsgate Subdivision Water Line Design Approaches Mr. Thompson: At this time we request variance from the BCS Unified Water Line Guidelines. Enclosed is a Fire Flow Analysis, which demonstrates that that the schematic preliminary design depicted on preliminary plat provides appropriate fire flows within the standards of good design practice. Please contact Lenwood Adams, P.E., or me if you need to discuss this matter. Sincerely, MUNICIPAL DEVELOPMENT GROUP `, l c,S71---- Gr- : •ry K aggart R.P.L.S i . agin?, 'rincipal 000886- c.04(3736) 2551 Texas Ave. South Ste. A. College I C, a Station TX 77840 ,QP `C Ofc: 979.693.5359 Fax_ 919.693.4243 Email: mdgcstx yahoo.cont fr t ,.. 1 � S) O June 15, 2004 Attn: Spencer Thompson City of College Station Development Services 1101 Texas Ave., South College Station, Texas 77842 RE: Williamsgate Subdivision Sanitary Sewer Report Dear Mr. Thompson: In reference to the Williamsgate Subdivision Sanitary Sewer Report city review comments dated June 9, 2004, comment #1 stated, "Sewer report in insufficient for approval. Refer to BCS Unified Design Manual. Demonstrate downstream impact. The sewer line shown as the discharge point was designed as a Sewer Impact Fee line. Demonstrate how the proposed system affects the impact fee line ?" After reviewing the report, we have found nothing in the BCS Unified Design Manual specifying errors in calculations (calculations were made using method 2). We believe we have sufficiently demonstrated the impact the proposed line will have on the existing system at the tie in location, and, therefore need more elaboration in order to resolve your questions of our report. If you could please contact and expand on the review comment, it would be appreciated. Very sincerely yours, Municipal Development Group r l - Lenwood . Adams, P.E. Principal CC: Tom Adair — Development Manager Ed WdES : 20 tOOE ST 'unf 217E17- 269 -6Lb : '0N Xtid dlOHO 1N9Wd019( G ldd I O I NlW : woad 4 1 4 , 2551 Texas Ave. South, Ste. A, College Station, TX 77840 V P* Ofc: 979.693.5359 Fax: 979.693.4243 Email: mdgcstx @yahoo.com I June 16, 2004 Spencer Thompson City of College Station Development Services 1101 Texas Ave., South College Station, Texas 77842 RE: Williamsgate Subdivision Water and Fire Flow Report Dear Mr. Thompson: Attached is the revised water and fire flow report for Williamsgate Subdivision. Water line sizes have been changed on the plat and are now in compliance with City standards. Water analysis for the system was performed under the assumption that if the system sufficiently supports the fire hydrants and is in compliance with the fire flow requirements, it will be more than adequate for supplying domestic water. If you have any questions, please call. Very sincerely yours, Municipal Development Group �� OF ® sw eekv �E r � ' ; Lenwood S. Adams, P.E. F LENWOOD S. ADAMS Principal Es 1 1,, 63351