HomeMy WebLinkAboutApplicationFOR OFFICE USE ONLY
P&Z CASE NO.: ai ` � ,
DATE SUBMITTED
SITE PLAN APPLICATION
MINIMUM SUBMITTAL REQUIREMENTS
x Site plan application completed in full.
x $200.00 Application Fee.
_x $200.00 Development Permit Application Fee.
NA $600.00 Public Infrastructure Inspection Fee if applicable. (This fee is payable if construction of a public
waterline, sewerline, sidewalk, street or drainage facilities is involved.)
X Eleven (11) folded copies of site plan
* One (1) folded copy of the landscape plan.
_NA Two (2) copies of public infrastructure plans associated with this site plan (if applicable).
X One (1) copy of building elevation required for buildings with a footprint of 20,000 sq. ft. or greater
X A list of building materials for all facades that are visible from the public right -of -way.
X A copy of the attached site plan checklist with all items checked off or a brief explanation as to why they are
not checked off.
NA Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
* a-7ner's consultant under Separate cover.
Date of Preapplication Conference: 26 April 2004
NAME OF PROJECT State Bank - Wellborn Road Branch
ADDRESS
12995 EM 2154
LEGAL DESCRIPTION Edelweiss Business Center, Block 1, Lot 8, Robert Stevenson, A -54 Sur
APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name Rob ert A. Williamson
Street Address 2900 South Texas Avenue City Bryan
State Texas Zip Code 77801 E -Mail Address bobber -will i amsen@sta e-hanktx_
Phone Number 979 - 779 -2900 Fax Number 979 - 779 -1539
PROPERTY OWNER'S INFORMATION:
Nam State Bank
Street Address
State Texas
Phone Number
202 West Colorado
_ Zip Code 78945
(979) 968 -7280
ARCHITECT OR ENGINEER'S INFORMATION:
Nam Patters Architects
Street Address
701 S. Texas Avenue
State Texas Zip Code 77803
Phone Number (979) 775 -6036
6/13/03
E -Mail Address
City LaGrange
Fax Number (979) 968 -9781
Cit Bryan
E -Mail Address design@patarch. ccm
Fax Number (979) 779 -0727
1of6
OTHER CONTACTS (Please specify type of contact, i.e. project manager, potential buyer, local contact, etc.)
Name N/A
Street Address City
State
Phone Number
E -Mail Address
Fax Number
CURRENT ZONING C -1
PRESENT USE OF PROPERTY undeveloped
PROPOSED USE OF PROPERTY drive through bank bran
VARIANCE(S) REQUESTED AND REASON(S) None
# OF PARKING SPACES REQUIRED 4
# OF PARKING SPACES PROVIDED 17
MULTI - FAMILY RESIDENTIAL
Total Acreage N/ A
Floodplain Acreage
Housing Units
# of 1 Bedroom Units
# of 2 Bedroom Units
# of 3 Bedroom Units
# of 4 Bedroom Units
FOR 2 BEDROOM UNITS ONLY
# Bedrooms = 132 sq. ft.
# Bedrooms < 132 sq. ft.
PARKLAND DEDICATION
# of Multi - Family Dwelling Units
X $452 = $ N/A
# of acres in floodplain
# of acres in detention
# of acres in greenways
date dedication approved by Parks Board
COMMERCIAL
Total Acreage 1.9744
Building Square Feet 864
Floodplain Acreage -0-
NOTE: Paridand Dedication fee Is due prior to the issuance or a ounun19 -
The applicant has prepared this application and certifies that the facts stated herein and exhibits attached
hereto are true and correct.
Signature of Owner, Agent or Applicant
4 August 2004
Date
gas
6/13/03
SUBMIT APPUCATION AND THIS
LIST CHECKED OFF WITH 10
k _ (NCI UiLIC -0 FOLDED COPIES OF SITE PLAN FOR REVIEW
4t-- = Ntrf APPLA CA5L-e
SITE PLAN MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
1. Sheet size - 24" x 36" (minimum).
✓ 2. A key map (not necessarily to scale).
3. Title block to include:
Af Name, address, location, and legal description
Name, address, and telephone number of applicant
Name, address, and telephone number of developer /owner (if differs from applicant)
Name, address, and telephone number of architect/engineer (if differs from applicant)
Date of submittal
Total site area
j� ✓ 4. North arrow.
fSt ✓ 5. Scale should be largest standard engineering scale possible on sheet.
6. Ownership and current zoning of parcel and all abutting parcels.
f 7. Existing locations of the following on or adjacent to the subject site:
J ,1St Streets and sidewalks (R.O.W.).
Driveways (opposite and adjacent per Section 7.3 of the Unified Development Ordinance).
Buildings.
Water courses.
Show all easements clearly designating as existing and type (utility, access, etc.).
✓g 100 yr. floodplain and floodway (if applicable) on or adjacent to the proposed project site, note if
there is none on the site.
—( Utilities (noting size and designate as existing) within or adjacent to the proposed site, including
building transformer locations, above ground and underground service connections to buildings,
J and drainage inlets.
Meter locations.
J AR , Topography (2' max or spot elevations) and other pertinent drainage information. (If plan has too
much information, show drainage on separate sheet.)
8. Proposed location, type and dimensions of the following.:
Phasing. Each phase must be able to stand alone to meet ordinance requirements.
The gross square footage of all buildings and structures and the proposed use of each. If
different uses are to be located in a single building, show the location and size of the uses within
the building. Building separation is a minimum of 15 feet w/o additional fire protection.
t� Setbacks. Show building setbacks as outlined in the Unified Development Ordinance,
Article 5.
f Off - Street parking areas with parking spaces drawn, tabulated, and dimensioned. Minimum
parking space is 9'x 20', or on a perimeter row 9'x 18' with a 2' overhang. Designate number of
parking spaces required by ordinance and provided by proposal.
Handicap parking spaces.
y
®
Parking Islands. Raised landscape islands, (6" raised curb) a minimum of 180 sq. ft. are
required at both ends of every parking row (greenspace area contiguous to the end island maybe
applied toward the required 180 sq. ft.). Additionally, 180 sq. ft. of landscaping for every 15
interior parking spaces must be provided. All required islands must be landscaped or set with
decorative pavers, or stamped dyed concrete or other decorative materials as approved.
—®
Drives. Minimum drive aisle width.
IS
Curb cuts. For each proposed curb cut (including driveways, streets, alleys, etc.) locate existing
curb cuts on the same opposite side of the street to determine separation distances between
existing and proposed curb cuts. Indicate driveway throat length as measured in the Unified
Development Ordinance, Section 7.3 Access Management and Circulation.
Security gates (show swing path and design specs with colors).
Sidewalks (both public and private). Sidewalks are required at time of development if property
has frontage on a street shown on the Sidewalk Master Plan or if the review staff determines the
necessity.
I
Medians. Show any and all traffic medians to be constructed on site.
S
A fifteen foot parking setback from R.O.W. to curb of parking lot is required. Pavement may
encroach into this 15' setback by up to 7 contiguous parking spaces. A double parking island
(360 square feet) must be provided between each group of seven spaces. In no case may the
J
pavement be less than 6' from the property line.
Common open spaces sites
✓
Loading docks
Detention ponds
Guardrails
Q9
Retaining walls
Sites for solid waste containers with screening. Locations of dumpsters are accessible but not
visible from streets or residential areas. Gates are discouraged and visual screening is required.
(Minimum 12 x 12 pad required.)
�. _cd
Show all easements clearly designating as proposed and type (utility, access, etc.). If dedicated
by separate instrument list by volume and page.
�t
Utilities (noting size and designate as proposed) within or adjacent to the proposed site, including
building transformer locations, above ground and underground service connections to buildings.
Meter locations (must be located in public R.O.W. or public utility easement.).
0`
Proposed grading (1' max for proposed or spot elevations) and other pertinent drainage
information. (If plan has too much information, show drainage on separate sheet.)
,/Off
Show proposed and existing fire hydrants. Fire hydrants must be located on the same side of a
major street as a project, and shall be in a location approved by the City Engineer. Any structure
in any zoning district other than R -1, R -1A, or R -2 must be within 300 feet of a fire hydrant as
J�
measured along a public street, highway or designated fire lane.
Show fire department connections. FDC's should be within 150' of the fire hydrant. In no case
shall they be any further than 300' apart, and they shall be accessible from the parking lot without
being blocked by parked cars or a structure.
Show fire lanes. Fire lanes a minimum of 20 feet in width with a minimum height clearance of 14
feet must be established if any portion of the proposed structure is more than 150 feet from the
curb line or pavement edge of a public street or highway.
NOTE: Fire hydrants must be operable and accepted by the City, and drives must have an all
weather
surface as defined in the Zoning Ordinance Section 9 before a building permit can be issued.
*–/ 9- Will building be sprinkled? Yes ❑ No )4
If the decision to sprinkle is made after the site plan has been approved, then the plan must be
resubmitted.
-� 10. Wheelstops may be required when cars overhang onto property not owned by the applicant or
where there may be conflict with handicap accessible routes or above ground utilities, signs or
other conflicts.
i i . 5now curb and pavement detain. A b" raised curb is required around all edges of an parts of all
paved areas without exception. (To include island, planting areas, access ways, dumpster
locations, utility pads, etc.) No exception will be made for areas designated as "reserved for
future parking ".
44 12. Landscape plans as required in Section 7.5 of the Unified Development Ordinance. The
landscaping plan can be shown on a separate sheet if too much information is on the original
site plan. If requesting protected tree points, then those trees need to be shown appropriately
barricaded on the landscape plan. Attempt to reduce or eliminate plantings in easements.
Include information on the plans such as:
required point calculations
VS additional streetscape points required. Streetscape compliance is required on all streets.
CJ` calculations for # of street trees required and proposed (proposed street tree points will accrue
toward total landscaping points.)
proposed new plantings with points eamed
proposed locations of new plantings
iV screening of parking lots, 50 % of all shrubs used for screening shall be evergreen.
screening of dumpsters, concrete retaining walls, off street loading areas, utility connection
points, or other areas potentially visually offensive.
existing landscaping to remain
u show existing trees to be barricaded and barricade plan. Protected points will only be awarded
`/ if barricades are up before the first development permit is issued.
U, Buffer as required in Section 7.6 of the Unified Development Ordinance.
13. Show irrigation system plan. (or provide note on how irrigation system requirement will be met
prior to issuance of C.O.) All plans must include irrigation systems for landscaping. Irrigation
meters are separate from the regular water systems for buildings and will be sized by city
according to irrigation demand submitted by applicant and must include backflow prevention
protection.
14. Is there any landscaping in TxDOT R.O.W.? Yes ❑ No
If yes, then TxDOT permit must be submitted.
15. Will there be any utilities in TxDOT R.O.W.? Yes ❑ No E,
If yes, then TxDOT permit must be submitted.
_-® 16. Will there be access from a TxDOT R.O.W.? Yes No ❑
If yes, then TxDOT permit must be submitted.
IP'v 17. The total number of multi - family buildings and units to be constructed on the proposed project
site.
-� 18. The density of dwelling units per acre of the proposed project.
181 ✓ 19. Provide a water and sanitary sewer legend to include water demands (minimum, maximum and
average demands in gallons per minute) and sewer loadings (maximum demands in gallons per
day).
9/ 2 Are there impact fees associated with this development? Yes ❑ No ❑
NOTE: Signs are to be permitted separately.