HomeMy WebLinkAboutWater Report I Water System Report for Meadow Creek Subdivision, Phase 4B College Station, Texas November, 2011 Prepared By: Schultz Engineering, LLC TBPE Firm Registration No. 12327 2730 Longmire, Suite A College Station, Texas 77845 979.764.3900 5t* °F its N \\**. JOSEPH P. SCHULTZ 6588*. I / / ''` "'' °" C1.14,11 F -12327 SCHULTZ ENGINEERING, LLC. General Information Location: Meadowcreek Subdivision, Phase 4B is located in southern Brazos County, just off Koppe Bridge Road near Wellborn. It is immediately adjacent to Phase 4A of the subdivision. General Note: There are 38 lots in Phase 4B. Land Use: Single Family Residential Design Criteria /Analysis Primary Water Supply: Existing 12" line along Koppe Bridge Road. It is connected to Phase 1 by an 8" line. The supply for Phase 4B will connect to 2 — 8" lines constructed with Phase 4A. Existing System Pressure Tests: Flow Hydrant - See Exhibit B Flowrate: 1,088 gpm Static Pressure: 80 psi Residual Pressure: 65 psi Exhibits: Exhibit A — Location Map Exhibit B — Hydrant Flow Test Results Exhibit C — Pipe and Junction Analysis — Domestic Demand Exhibit D — Pipe and Junction Analysis — Fire Flow Demand @ FH 1 Exhibit E — Pipe and Junction Analysis — Fire Flow Demand @ FH 2 Fire Flow: 1,000 gpm for Single Family Residential Domestic Use 1.5 gpm per lot for Single Family Residential The proposed 8" water lines are in accordance with the BCS Water Design Guidelines. This report provides the results of the water system analysis under the fire flow and domestic demand requirements, (1,128 gpm) which produced the lowest pressure in the system. The lowest residual pressure with the fire flow and domestic demand occurs with the fire flow at Fire Hydrant 1 and is computed to be 56.2 psi. With the domestic demand only, the residual pressure is computed to be 75.1 psi. Each of these pressures exceed the 20 psi and 35 psi minimum pressure requirements, respectively. The maximum velocity in all pipes is less than 12 fps for all scenarios. Conclusion The proposed water system for Meadowcreek Subdivision, Phase 4B meets or exceeds all of the design criteria for the City of College Station. It will provide adequate water pressure and flow for both domestic and fire demands. Exhibit C WaterCAD Analysis Summary Pipe Analysis - Domestic Flow Hazen - Pipe Pipe William C- Pipe Flow Velocity Number Length (ft) Size (in) Material Value (GPM) (ft /s) P -1 220 8 PVC 150 43 0.27 P -2 459 8 PVC 150 17 0.11 P -3 259 8 PVC 150 2 0.02 P -4 250 8 PVC 150 -10 0.06 P -5 135 8 PVC 150 0 0 P -8 653 6 PVC 150 -43 0.48 P -9 308 6 PVC 150 61 0.69 P -10 181 8 PVC 150 0 0 P -RES 16 8 PVC 150 -126 0.8 P -6 29 8 PVC 150 -20 0.13 P -7 271 8 PVC 150 -20 0.13 Exhibit C WaterCAD Analysis Summary Junction Analysis - Domestic Flow Analysis 1 Elevation ' Demand Pressure Junction (ft) (GPM) (PSI) J -1 322 18 75.2 J -2 320 26 76.1 FH 1 312 15 79.5 J -4 309.5 12 80.6 J -5 307 11 81.7 J -6 306 0 82.1 J -7 308.5 23 81 Existing FH 317.5 23 77.2 J -9 308 0 81.2 FH 2 307.15 0 81.6 Exhibit D WaterCAD Analysis Summary Pipe Analysis - Fire Flow @ FH 1 Hazen - Pipe Pipe William C- Pipe Flow Velocity Number Length (ft) Size (in) Material Value (GPM) (ft /s) P -1 220 8 PVC 150 621 3.96 P -2 459 8 PVC 150 595 3.8 P -3 259 8 PVC 150 -420 2.68 P -4 250 8 PVC 150 -432 2.76 P -5 135 8 PVC 150 0 0 P -8 653 6 PVC 150 -465 5.27 P -9 308 6 PVC 150 639 7.25 P -10 181 8 PVC 150 0 0 P -RES 16 8 PVC 150 -1126 7.19 P -6 29 8 PVC 150 -442 2.82 P -7 271 8 PVC 150 -442 2.82 Exhibit D WaterCAD Analysis Summary Junction Analysis - Fire Flow Analysis @ FH 1 Elevation I Demand ' Pressure Junction (ft) (GPM) (PSI) J -1 322 18 56.2 J -2 320 26 56.5 FH -1 312 1,015 58.9 1 -4 3 12 60.3 J -5 307 11 61.7 J -6 306 0 62.1 J -7 308.5 23 61.4 Existing FH 317.5 23 61.4 1 -9 308 0 60.9 FH -2 307.15 0 61.6 Exhibit E WaterCAD Analysis Summary Pipe Analysis - Fire Flow @ FH 2 Hazen - Pipe Pipe William C- Pipe Flow Velocity Number Length (ft) Size (in) Material Value (GPM) (ft /s) P -1 220 8 PVC 150 569 3.63 P -2 459 8 PVC 150 544 3.47 P -3 259 8 PVC 150 _ 529 3.37 P -4 250 8 PVC 150 517 3.3 P -5 135 8 PVC 150 0 0 P -8 653 6 PVC 150 -516 5.86 P -9 308 6 _ PVC 150 587 6.66 P -10 181 8 PVC 150 0 0 P -RES 16 8 PVC 150 -1126 7.19 P -6 29 8 PVC 150 506 3.23 P -7 271 8 PVC 150 -494 3.15 Exhibit E WaterCAD Analysis Summary Junction Analysis - Fire Flow Analysis @ FH 2 Elevation Demand ; Pressure Junction (ft) (GPM) 1 (PSI) J -1 322 18 56.6 J -2 320 26 57 FH -1 312 15 59.6 J -4 309.5 12 60.2 J -5 307 11 60.8 J -6 306 0 61.3 J -7 308.5 23 60.6 Existing FH 317.5 23 61.4 J -9 308 0 60.8 FH -2 307.15 1000 60.7 Ll / I co . t . . . 1 r., c �3 II 11 I 1 W 8 ` Cloud Lane LL 1 ! L -----i----- –d .1 1 � fr 9 - . 3 'a' 64 O lk ) I Arrowcrest Drive I W -8 O ' OT -d a op o-A 3 4:1 4 3 M � 0 a.V o o `—'3 II w 04 , Z rn 3 L„ 2 L... i Z I 1 .fl I— ao — 3 (4 3 . n I t Q \ X o O= • ca al 0 2-10 o 1 Ia J 1 3 d� ON W l a_ - III — Lo 1 (2 al I . i")j) 0 1 -W -B ti_ 0 s 0 3 1